district centre

30
COMMUNITY CENTRE COMPILED BY – AISVARYA SINGH DEO A51204011039 BACHELOR OF ARCHITECTURE 7 TH SEMESTER ARCHITECTURAL DESIGN 1

Upload: vabs

Post on 22-Dec-2015

8 views

Category:

Documents


3 download

DESCRIPTION

dghgh

TRANSCRIPT

Page 1: District Centre

COMMUNITY CENTRE

COMPILED BY –AISVARYA SINGH DEO

A51204011039BACHELOR OF ARCHITECTURE

7TH SEMESTERARCHITECTURAL DESIGN

1

Page 2: District Centre

LOCATION MAP

2

Page 3: District Centre

LOCATION - CHANDRASHEKHARPUR,BHUBANESWAR

ChandrashekharpurChandrashekharpur is a well developed residential,commercial,educational hub in Bhubaneswar,Odisha. Lying north of National Highway 5 it was developed by Bhubaneswar Development Authority to house the growing population.

NeighbourThe neighbouring areas are Raghunathpur,Nayapalli, Jayadev Vihar, Sailashree Vihar,Patia

BHUBANESWAR PLAN3

Page 4: District Centre

As per provisional reports of Census India, population of Bhubaneswar in 2011 is 837,737; of which male and female are 445,233 and 392,504 respectively. Although Bhubaneswar city has population of 837,737; its urban / metropolitan population is 881,988 of which 468,302 are males and 413,686 are females.

BHUBANESWAR POPULATION 2011

BHUBANESWAR LITERACY

Bhubaneswar's literacy rate is 93.15 per cent—significantly higher than the national average of 74.04per cent. . In education section, total literates in Bhubaneswar city are 710,243 of which 388,164 are males while 322,079 are females. Average literacy rate of Bhubaneswar city is 93.15 percent of which male and female literacy was 95.69 and 90.26 percent.

Bhubaneswar population growth chart

POPULATION AND ECONOMIC STATUS

4

Page 5: District Centre

SITE ANALYSIS

• It is a commercial cum residential hub located in Chandrashekharpur,Bhubaneswar• Dense residential area around the site.• Access roads on two sides of the site.•The surroundings to the site is mostly residential,some of commercial,recreational and public areas

SITE

The site is well connected with roads which makes it easily accessible

The roads on two sides of the site are of sufficient width for the traffic generated.

Its primary location in the residential area makes it a focal point

5

Page 6: District Centre

LAND USE MAP OF BHUBANESWAR

6

Page 7: District Centre

CLIMATE ANALYSIS

N

WIND The wind direction to the site is North-West

Bhubaneswar is located on the coastal plains of Odisha (Orissa), south-west of the River Mahanadi. It experiences typical tropical weather conditions, and succumbs to the heat and cold waves that sweep in from north India.The summer months from March to May are hot and humid, and temperatures often shoot past 40° C in May.

The south west monsoon lashes Odisha (Orissa) in June, bringing relief to the parched environs of Bhubaneswar.

Pleasant weather conditions prevail during November in Bhubaneswar, but December and January face the chilly winds from the North North-east at average speeds of 7 miles/hour. Temperatures drop to approximately 15° C during these months.

7

Page 8: District Centre

Site SpecificationsSite Area - 4 hectares, 40,000 sqmF.A.R - 1.25Ground coverage - 25%Height - Not RestrictedProximity - Airport 9.7kms , Railway Station 11kmsVegetation - Tropical trees and shrub coverTopography - No contoursClimate - Warm and humid

Distance of Site from Railwat Stn. Distance of site from Airport8

Page 9: District Centre

Area CalculationF.A.R = Built Up Area Total AreaBuilt Up Area = F.A.R x Total Area = 1.25 x 40,000 SQ.M = 50,000 SQ.MTotal Ground Coverage = 25% = 25 x 40,000 = 10,000 SQ.MPermissible no. of floors = 50,000 = 5 nos. 10,000Set Backs :Front = 15 M Rear = 9 M Side 1 = 9M Side 2 = 9M

Site Dimensions – 210 M * 191 M = 40110 SQ.M = 4 hectares

SITE

210000

191

000

N

9

Page 10: District Centre

Parking Standards – 100 msq for 3 ECSTotal built up area = 50,000 sqmTotal Ground Coverage = 10,000 sqm = 3 x 50,000 = 1500 ECS 100

REQUIREMENTS

OFFICE- 59.4% HOTEL- 10% RETAIL SHOPS- 30% AUDITORIUM- 0.6% (300 SEATS) OPEN AIR THEATRE- 300 SEATS

CALCULATION- BUILT UP AREA

OFFICE-59.4% OF BUILT UP AREA = 59.4*50,000/100 = 29,700 SQ.M

HOTEL- 10% OF BUILT UP AREA =10*50,000/100 = 5000 SQ.M

10

Page 11: District Centre

RETAIL SHOPS- 30% OF BUILT UP AREA = 30*50,000/100 =1500 SQ.M

AUDITORIUM- 0.6% OF BUILT UP AREA = 0.6*50,000/100 = 300 SQ.M

OCCUPANT LOAD

OFFICE- CATEGORY-BUSINESS OCCUPANT LOAD PER 100 SQ.M OF COVERED AREA- 10 PEOPLE BUILT UP AREA- 29,700 SQ.M OCCUPANT LOAD- 10*29,700/100= 2970 OCCUPANTS

HOTEL- CATEGORY-RESIDENTIAL OCCUPANT LOAD PER 100 SQ.M OF COVERED AREA- 8 PEOPLE BUILT UP AREA- 5000 SQ.M OCCUPANT LOAD- 8*5000/100= 400 OCCUPANTS

RETAIL SHOPS- CATEGORY- MERCANTILE OCCUPANT LOAD PER 100 SQ.M OF COVERED AREA- 50 PEOPLE BUILT UP AREA- 15,000 SQ.M OCCUPANT LOAD- 50*15,000/100= 7500 OCCUPANTS

11

Page 12: District Centre

AUDITORIUM AND OPEN AIR THEATRE- OCCUPANT LOAD- 300 OCCUPANTS

WATER CALCULATION

OFFICE- CONSUMPTION PER HEAD PER DAY- 45LT. OCCUPANT LOAD- 2970 WATER CONSUMPTION PER DAY- 2970*45= 133650 LT.

STANDARD CALCULATION VOLUME UNIT NO. OF TANKS

VOLUME(PER TANK)

SIZE OF TANK

WATER TANK

1CUM/1000 LT. 133650/1000 133.65 CUM 2 66.8 6*4*2.8

STANDARD CALCULATION VOLUME UNIT NO. OF TANKS

SIZE OF TANK

FIRE TANK 0.2%* WATER TANK

0.2*133.6 26.73 CUM 1 2.5*4*2.7

12

Page 13: District Centre

HOTEL- CONSUMPTION PER BED PER DAY- 180 LT. OCCUPANT LOAD- 400 WATER CONSUMPTION PER BED PER DAY- 400*180 = 72000 LT.

STANDARD CALCULATION VOLUME UNIT

NO. OF TANKS

VOLUME (PER TANK)

SIZE OF TANK

WATER TANK

1CUM/1000 LT. 72000/1000 72 CUM 2 36 4*3*3

STANDARD CALCULATION VOLUME UNIT NO. OF TANKS

SIZE OF TANK

FIRE TANK 0.2*WATER TANK

0.2*72 14.4 CUM 1 2.4*2.4*3

13

Page 14: District Centre

RETAIL SHOPS- CONSUMPTION PER HEAD PER DAY- 45LT. OCCUPANT LOAD- 7500 WATER CONSUMPTION PER DAY- 7500*45= 337500LT.

STANDARD CALCULATION

VOLUME

UNIT NO. OF TANKS

VOLUME (PER TANK)

SIZE OF TANK

WATER TANK

1CUM/1000 LT. 337500/1000 337.5 CUM 6 56.25 5.6*5*2

STANDARD CALCULATION VOLUME UNIT NO. OF TANKS

VOLUME (PER TANK)

SIE OF TANK

FIRE TANK

0.2*WATER TANK

0.2*337.5 67.5 CUM 2 33.75 4.2*4*2

14

Page 15: District Centre

AUDITORIUM- CONSUMPTION PER SEAT PER DAY- 15 LT. OCCUPANT LOAD- 300 WATER CONSUMPTION PER DAY- 300*15= 4500LT.

STANDARD CALCULATION VOLUME UNIT NO. OF TANKS

VOLUME (PER TANK)

SIZE OF TANK

WATER TANK

1CUM/1000 LT.

4500/1000 4.5 CUM 1 4.5 2*2.5*1

STANDARD CALCULATION VOLUME UNIT NO. OF TANK

SIZE OF TANK

FIRE TANK 0.2*WATER TANK

0.2*4.5 0.9 CUM 1 0.9*1*1

15

Page 16: District Centre

SANITATION CALCULATION OFFICE- OCCUPANT LOAD- 2970 RATIO OF MALE AND FEMALE- 1:1 THUS, MALE- 1485, FEMALE- 1485

16

Page 17: District Centre

S.NO. SANITARY UNIT STANDARD (MALE)

QUANTITY (MALE)

STANDARD (FEMALE)

QUANTITY (FEMALE)

1. WATER CLOSET 1 FOR 25 PERSONS

59 1 FOR 15 PERSONS

99

2. ABLUTION TAPS 1 FOR EACH W.C.

59 1 FOR EACH W.C.

99

3. URINALS OVER 200 PERSONS ADD AT THE RATE OF 2.5%

60 - -

4. WASH BASINS 1 FOR 25 PERSONS

59 1 FOR 25 PERSONS

59

5. DRINKING WATER FOUNTAINS

1 FOR 100 PERSONS (MIN. 1 ON EACH FLOOR)

15 - -

7. CLEANER’S SINK 1 PER FLOOR MINIMUM

15 - -17

Page 18: District Centre

HOTEL- OCCUPANT LOAD- 400 RATIO OF MALE AND FEMALE- 1:1 THUS, MALE- 200, FEMALE- 200

18

Page 19: District Centre

S.NO. SANITARY UNIT STANDARD (MALE)

QUANTITY (MALE)

STANDARD (FEMALE)

QUANTITY (FEMALE)

1. WATER CLOSET 1 FOR 25 PERSONS

8 1 FOR 15 PERSONS

13

2. ABLUTION TAPS 1 FOR EACH W.C.

8 1 FOR EACH W.C.

13

3. URINALS FOR 101- 200 PERSONS ADD AT THE RATE OF 3%

8 - -

4. WASH BASINS 1 FOR 25 PERSONS

8 1 FOR 25 PERSONS

8

5. DRINKING WATER FOUNTAINS

1 FOR 100 PERSONS (MIN. 1 ON EACH FLOOR)

2 - -

7. CLEANER’S SINK 1 PER FLOOR MINIMUM

5 - -19

Page 20: District Centre

RETAIL SHOPS- OCCUPANT LOAD- 7500 RATIO OF MALE AND FEMALE- 1:1 THUS, MALE- 3750, FEMALE- 3750

20

Page 21: District Centre

S.NO. SANITARY UNIT STANDARD (MALE)

QUANTITY (MALE)

STANDARD (FEMALE)

QUANTITY (FEMALE)

1. WATER CLOSET 1 FOR 25 PERSONS

150 1 FOR 15 PERSONS

250

2. ABLUTION TAPS 1 FOR EACH W.C.

150 1 FOR EACH W.C.

250

3. URINALS OVER 200 PERSONS ADD AT THE RATE OF 2.5%

154 - -

4. WASH BASINS 1 FOR 25 PERSONS

150 1 FOR 25 PERSONS

150

5. DRINKING WATER FOUNTAINS

1 FOR 100 PERSONS (MIN. 1 ON EACH FLOOR)

38 - -

7. CLEANER’S SINK 1 PER FLOOR MINIMUM

5 - -21

Page 22: District Centre

AUDITORIUM- OCCUPANT LOAD- 300 RATIO OF MALE AND FEMALE- 1:1 THUS, MALE- 150, FEMALE- 150

22

Page 23: District Centre

S.NO. SANITARY UNIT STANDARD (MALE)

QUANTITY (MALE)

STANDARD (FEMALE)

QUANTITY (FEMALE)

1. WATER CLOSET 1 FOR 25 PERSONS

6 1 FOR 15 PERSONS

10

2. ABLUTION TAPS 1 FOR EACH W.C.

6 1 FOR EACH W.C.

10

3. URINALS FOR 101- 200 PERSONS ADD AT THE RATE OF 3%

6 - -

4. WASH BASINS 1 FOR 25 PERSONS

6 1 FOR 25 PERSONS

6

5. DRINKING WATER FOUNTAINS

1 FOR 100 PERSONS (MIN. 1 ON EACH FLOOR)

2 - -

7. CLEANER’S SINK 1 PER FLOOR MINIMUM

1 - -23

Page 24: District Centre

CONCEPT OF DESIGN

Office building 10 floors

Retail shops 3 floors Hotel 5 floors

• Concept of Offices, Shops and Hotel with a multi level garden• The concept is to disintegrate the mall into an arrangement of commercial blocks (with shopping areas below and office and other spaces on the upper floors

24

Page 25: District Centre

• Segregation of activities through levels, define uninterrupted user specific moment.

• Spaces like amphitheaters, food courts are in open spaces

Conceptual View

25

Page 26: District Centre

UNDERGROUND PARKINGGRID : 8.5M *6M

26

Page 27: District Centre

AREA FOR UNDERGROUND PARKING : 168 * 144.5 = 24276 SQ.M

FOR UNDERGROUND PARKINGIT IS 32 SQ.M FOR 1 ECSFOR 24276 SQ.M ECS = 24276/32 = 758 ECS

UNDERGROUND PARKING CALCULATIONS

GRID : 8.5 M * 6 M

COLUMN SIZE 1M * 1M

CAR SPACE 5 M* 2.5 M

8.5M

7.5M

6M

2.5M

5M

27

Page 28: District Centre

FLOOR PLATE

S1

S2

S3S4

S6

S5

RETAIL COMPLEX

28

Page 29: District Centre

HOTEL COMPLEX

FLOOR PLATE

29

Page 30: District Centre

THANK YOU

30