DIRECT LINK MODE
OPERATOR GUIDE
TAKING MEASUREMENTS USING SPC3D6 AND A PC
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page i SPC3d6.0
Copyright © 2011 Third Dimension
All rights reserved.
You must not reproduce or distribute any part of
this publication in any form or by any means,
electronic or mechanical, without prior permission
in writing from Third Dimension. This includes
photocopying, recording or any other information
storage or retrieval system.
This version produced on 1 August 2012
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page ii SPC3d6.0
CONTENTS 1 Screen ......................................................................................................................................................................................... 1
2 System Icons............................................................................................................................................................................... 2
2.1 Setting Local Time ............................................................................................................................................................. 2
2.2 Battery Test Report ........................................................................................................................................................... 2
2.3 Connectivity ....................................................................................................................................................................... 3
2.4 System Shortcuts ............................................................................................................................................................... 3
2.5 New Serial Number Shortcut ............................................................................................................................................. 4
2.6 Local Menus Shortcut ........................................................................................................................................................ 7
2.7 Status Report Shortcut ...................................................................................................................................................... 8
2.8 User Level Shortcut ........................................................................................................................................................... 9
2.9 Return to Main Menu ...................................................................................................................................................... 10
2.10 Additional Icon for USB ................................................................................................................................................... 10
3 Direct Link Tools ....................................................................................................................................................................... 11
4 Link To SPC3d6 ......................................................................................................................................................................... 12
4.1 Open SPC3d6 ................................................................................................................................................................... 12
4.2 SPC3d Toolkits ................................................................................................................................................................. 13
4.3 SPC3d Checkplans ............................................................................................................................................................ 14
4.4 SPC3d My Menus ............................................................................................................................................................. 18
5 Calibration Checkplans ............................................................................................................................................................. 21
6 Hex Artefact Measurement ...................................................................................................................................................... 22
6.1 The Hex Artefact .............................................................................................................................................................. 22
6.2 The Hex Artefact SCP3d6 Checkplan ............................................................................................................................... 23
6.3 Measuring the Hex Artefact ............................................................................................................................................ 25
7 Taking a Measurement Whilst Linked to SPC3d6 .................................................................................................................... 26
7.1 Measurement Diagnostics ............................................................................................................................................... 27
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page iii SPC3d6.0
8 Exporting and Importing Data .................................................................................................................................................. 28
9 Linking to SPC3d via LAN or Wi-Fi ............................................................................................................................................ 28
10 Contact Third Dimension.......................................................................................................................................................... 29
11 Notes ........................................................................................................................................................................................ 30
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 SPC3d6.0
Page left intentionally blank
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 1 SPC3d6.0
1 SCREEN
The screen on the GapGun MX+ is a touch screen and has the ability to scroll up/down using your finger. A dark menu bar on the
right hand side of the screen will tell you that there are more options below the bottom of the screen. Scroll down to see them.
TITLE BAR
Tap this area to go up one level in the GapGun MX+ menu.
USB
Tap this to gain access to USB functions, when a USB device is connected.
CONNECTIVITY
Signifies ethernet connection to SPC3d6 or no connection.
LINK TO SPC3D TOOLKITS
This links the operator to all the available toolkits stored in SPC3d6. Certain Virtual Tools that run through SPC3d6 cannot be run in Roaming Mode due to complex computing.
LINK TO SPC3D OPEN CHECKPLANS
This link will give you access to any checkplan that is open in SPC3d6.
For additional icons not covered her please refer to;
D11-603 ‘GapGun MX+ Roaming Mode Operator Guide’
D11-635 ‘GapGun MX+ Data Transfer Guide’
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 2 SPC3d6.0
2 SYSTEM ICONS
In the top right of the GapGun MX+ screen there is a small collection of icons which enable the operator to view and change
settings on the GapGun MX+.
There are four icons.
2.1 SETTING LOCAL TIME
SETTING TIME
Setting time is only available in Admin Mode.
For further help please see your administrator or contact
2.2 BATTERY TEST REPORT
BATTERY
By tapping battery icon you will get a display giving further
options regarding the battery.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 3 SPC3d6.0
2.3 CONNECTIVITY
COMMUNICATION INFORMATION
Tapping the PC screen icon in operator mode leads you to this screen. Please see your administrator for further help.
2.4 SYSTEM SHORTCUTS
SYSTEM MENU
By tapping the system shortcuts icon (scroll icon) you will
enter into the system menus.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 4 SPC3d6.0
2.5 NEW SERIAL NUMBER SHORTCUT
NEW SERIAL NUMBER MENU
Selecting this option to enter a new serial number.
ENTER SERIAL NUMBER
Here you have the option to enter a SN via the keypad or you
can tap on ‘Bar Code’, bottom left, to read a bra code.
The barcode function can scan barcodes up to ~50mm long, depending on the density of the barcode. Supports CODE128,
CODE39, Interleaved 2/5.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 5 SPC3d6.0
ENTER BARCODE MENU
There are three methods of entering a serial number.
1. Barcode Entry 2. Enter with Keypad 3. Keep Current Value
Tap this option to enter a barcode for your Measurement Cycle.
The barcode read by the GapGun MX+ will be used as the Serial Number that would have been inputted manual.
BARCODE READING HEADS
Only GapGun Heads marked U or M can be used to read barcodes. Please check your head is compatible.
Pull and hold the trigger to read a barcode.
READING BARCODE
To read a barcode pull the trigger and place the laser across the barcode.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 6 SPC3d6.0
Scan these barcodes for practice.
Code_128
Code_128
Code39
BARCODE S/N
Once you have scanned a bar code it will be used as the Serial Number for your measurement cycle. This screen is shown for reference only. Once the barcode is read the GapGun MX+ screen will return to the main menu.
When you enter a checkplan to perform measurements the scanned barcode will already be present as the SN.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 7 SPC3d6.0
2.6 LOCAL MENUS SHORTCUT
LOCAL MENUS
Tap this option to enter into the local my menus area.
MY MENUS
In this section the administrator has the ability to create local
menus specific to your GapGun MX+ handle. This area is
reserved for administrators.
This ‘Sample.ggm’ is a sample GapGun MX+ menu showing
power settings for the GapGun MX+ handle.
Your administrator may have setup a sequence of
measurements specific to you.
For further help please see your administrator or contact
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 8 SPC3d6.0
2.7 STATUS REPORT SHORTCUT
GAPGUN STATUS
Tap this option to view data on the GapGun MX+ Handle.
GAPGUN STATUS REPORT
This screen shows you information about your GapGun MX+
handle such as:
Software version
Handle serial number
Head serial number
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 9 SPC3d6.0
2.8 USER LEVEL SHORTCUT
USER LEVEL
Tap this to enter into the User level setup.
USER LEVEL SETUP
Here you can see the current user level and change the user level.
For other user levels please see your administrator or contact [email protected].
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 10 SPC3d6.0
2.9 RETURN TO MAIN MENU
RETURN TO MAIN MENU SHORTCUT
This option will return you to the main GapGun MX+ menu
screen.
2.10 ADDITIONAL ICON FOR USB
When you connect a USB device the system icon area will look like this:
The USB icon will give you access to USB functions.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 11 SPC3d6.0
3 DIRECT LINK TOOLS
It is important to understand the difference between Onboard and Direct Link Tools that will be use on your GapGun MX+.
TOOLKITS
The tool being used is not on the GapGun MX+ handle. The tool is being used from SPC3d6 in Direct Link Mode. With Roaming mode the tools are Onboard Tools.
Note: This document is for Direct Link Mode. The tools and checkplans you will use are being used from SPC3d6.
See D11-603 ‘GapGun MX+ Roaming Mode Operator Guide’ for Local Tools and settings.
RESULTS
The above image shows the ID of the measurement, the Serial Number of the measurement Cycle, the name of the Virtual Tool used, ‘GAPFLUSH\VCRAD’ and finally the results from the measurement, in this case Gap & Flush.
A basic profile display appears in the centre of the screen. A more detailed view is displayed in SPC3d.
In Roaming Mode the level of detail required on the handle is higher as you are not connected to SPC3d6.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 12 SPC3d6.0
4 LINK TO SPC3D6
4.1 OPEN SPC3D6
DOUBLE CLICK THE ICON
Use this icon on your desktop to open SPC3d6.
SPC3D6 WINDOW
Once the software opens this screen will appear. The small green circle in the bottom left signifies that your GapGun MX+ is connected to the software. The circle will be red to start with and connection can take a few moments. Once connected you will have full access to the toolkits and checkplans from SPC3d6 on your GapGun MX+ handle.
LINK TO SPC3D SOFTWARE
Once the connection between the GapGun MX+ and SPC3d6 is made these options will be available.
Tap this link for SPC3d6 toolkit options.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 13 SPC3d6.0
4.2 SPC3D TOOLKITS
TOOLKIT SELECTION
Here you will see all the toolkits stored on your PC that are available through SPC3d.
There will be the standard toolkits available plus any that have been created for your specific application. Toolkits and tools are created by an administrator.
For further help please see your administrator or contact [email protected].
Please see ‘GapGun MX+ Roaming Mode Operator Guide’ D11-603 for instructions on how to measure using the GapGun MX+.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 14 SPC3d6.0
4.3 SPC3D CHECKPLANS
SPC CHECKPLAN MENU
Tap this option to link to a checkplan that is open in SPC3d.
Note: A checkplan needs to be open in SPC3d in order for this menu option to see it.
OPENING A CHECKPLAN IN SCP3D
On the PC, click on the ‘Open’ icon to open a checkplan.
SELECTING CHECKPLAN
This window will appear and all the available checkplans will be listed. Checkplans for the GapGun MX+ can be either *.gg files or *.xls files. Either file option will work with the GapGun MX+.
Select the checkplan you wish to open.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 15 SPC3d6.0
CHECKPLAN OPEN IN SPC3D
Depending on the size and complexity of the checkplan it may take some time to open. Once opened the SPC3d window will look similar to this.
CHECKPLAN OPEN IN EXCEL
The same checkplan may have been created in Excel. The Excel checkplan will look similar to this.
Note: Both the GapGun and Excel checkplans are the same.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 16 SPC3d6.0
SELECT CHECKPLAN FROM GAPGUN MX+ HANDLE
Once a checkplan is open in SPC3d6 you will see the option to open it on your GapGun MX+ handle.
Tap on the checkplan you wish to open.
Note: At this moment the checkplan is only open in SPC3d6, it has not been loaded to the GapGun MX+ handle. The checkplan is not actually copied to the handle; it is being used from the PC via the GapGun MX+.
SELECTING A MASTER
Once the checkplan has been opened you will be presented with a list of available options from within that checkplan. Here you can see the available ‘Masters’ from the checkplan.
Note: Most checkplans will behave in the same way but may look different depending on their design.
Note: A ‘Master’ is an area of measurement from within your overall measurement plan. Each ‘Master will have measurement ‘Sections’.
For further help please see your administrator or contact [email protected].
ENTER A VIN NUMBER
Some checkplans will require you to enter a unique number to identify the measurement cycle. In this case you will need to enter a VIN number.
Enter the VIN number by scanning a barcode or using the keypad.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 17 SPC3d6.0
MEASURING WITH A CHECKPLAN
You are now in the checkplan. This is the first measurement section to be taken. The screen gives a graphical image of where to measure i.e. which section. The tool is automatically set by the checkplan. The operator has to measure this point and then the checkplan moves onto the next measurement point.
This checkplan is a learning aid (ideal if you actually have a Smart Car), designed to help take measurements and understand checkplans.
ACCEPT & EXIT
Once the ‘Master’ has been completed the operator can save the data. The data is saved to the PC using the VIN number entered earlier as a reference.
You will then be able to move onto the next ‘Master’ and continue measuring.
Note: Additional data may be generated and/or printed at this point depending on your administrators’ checkplan settings. This is unique to ‘Direct Link Mode’ and not available in ‘Roaming Mode’.
For further help please see your administrator or contact [email protected].
CANCEL
The operator also has the option to cancel the measurements.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 18 SPC3d6.0
4.4 SPC3D MY MENUS
MY MENUS
Tap this icon to enter into the ‘My Menus’ section of the GapGun MX+.
USER MENU CERDISP
This CERDISP option can be used to display the GapGun MX+ handle screen on a PC monitor.
Tap this to activate CERDISP.
GAPGUN MX+ SCREEN ON THE PC
Once you have tapped the CERDISP icon this screen will appear on the GapGun MX+ handle. The same screen will have also appeared on the PC.
Tap ‘Hide’ to exit the CE Remote Display screen.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 19 SPC3d6.0
CE REMOTE DISPLAY
Here you can see the GapGun MX+ handle screen on the PC monitor screen. This facility can be very useful for teaching, learning and demonstrating the GapGun MX+.
Note: Although very useful it is not normally used by operators.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 20 SPC3d6.0
USER MENU SOUNDS
Tap this icon to listen to the sounds made by the GapGun MX+.
SOUND MENU
Here are all the options for the GapGun MX+ sounds. Tapping any of these options will lead you to a screen enabling you to listen to and reset the sounds.
Tap ‘Return’ to exit back to the main menu.
VOLUME
Tapping on the volume icon allows the operator to change the volume settings. The default setting is 30%.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 21 SPC3d6.0
5 CALIBRATION CHECKPLANS
These checkplans are meant as a means to check that your GapGun MX+ is measuring correctly and within tolerance.
The results from the measurements should match those on your calibration artefact. Each calibration artefact is specific to a
GapGun MX+ head, so the results should match those on your artefact. If the results of your calibration artefact check do not
match those on the artefact please contact Third Dimension [email protected].
There are two different types of calibration artefact.
CALIBRATION PIN GAUGE
This is used to check the calibration of the FOV7 head.
CALIBRATION BLOCK
This is used to check the calibration of the FOV15, FOV40 and FOV80 heads.
For calibration checkplans for all heads please refer to Document ‘GapGun MX+ Roaming Mode Operator Guide’ D11-603.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 22 SPC3d6.0
6 HEX ARTEFACT MEASUREMENT
6.1 THE HEX ARTEFACT
The Hex Artefact is meant as a measurement aid. It is not a calibrated artefact. Please use the Hex to practice measuring features using different tools selected by the checkplan or yourself, from the mobile toolkit menu.
Please see ‘GapGun MX+ Roaming Mode Operator Guide’ D11-603 for instructions on how to measure the Hex Artefact using
the GapGun MX+ handle checkplan.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 23 SPC3d6.0
6.2 THE HEX ARTEFACT SCP3D6 CHECKPLAN
With SPC3d6 open, use the open icon to open the Hex checkplan in SPC3d. Please refer to ‘Opening a Checkplan in SPC3d’
page14.
LINK TO SPC3D
You must use this menu option to access the Hex checkplan that you have opened in SPC3d6.
Note: Make sure the Hex checkplan is open in SPC3d.
HEX CHECKPLAN IN SPC3D6
The Hex checkplan in SPC3d6 looks like this. Once this is open you can access it via the GapGun MX+ handle.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 24 SPC3d6.0
LINK TO SPC CHECKPLANS
Tap this icon to enter into the checkplans that are open in SPC3d.
SPC CHECKPLANS MENU
Any checkplan that is currently open in SPC3d will appear here. Only the Hex & GapGun checkplans are open at the moment and available for use.
Tap on the checkplan you wish to use.
Note: The GapGun checkplan may still be open in SPC3d6, as shown here. You can have multiple checkplans open in SPC3d6. You can only use one at a time.
SELECT MEASUREMENT HEAD
For the Hex checkplan you must select the type of head you have on your GapGun MX+. Please see ‘GapGun Measurement Heads’ page Error! Bookmark not defined..
Once you have selected the head you will enter into the checkplan and start measuring.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 25 SPC3d6.0
6.3 MEASURING THE HEX ARTEFACT
ANGLE1
Once you enter the checkplan the first image will appear showing you where to measure. The tool being used is part of the checkplan and selected automatically.
The image shows the direction of the measurement. The icon shows the left-to-right measurement.(Red Triangle / Green Circle)
Pull the trigger to continue.
The on-screen text gives information about the tool and the measurement being taken.
ANGLE1: Measures the angle between two components using PANELGF approach.
The Hex checkplan will allow you to measure all the features on the artefact. You will see the SPC3d6 screen change and display
the measured data in detail.
Each measurement will result in a different display of data from the GapGun MX+.
Please see ‘GapGun MX+ Roaming Mode Operator Guide’ D11-603 for instructions on how to measure the Hex Artefact using
the GapGun MX+.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 26 SPC3d6.0
7 TAKING A MEASUREMENT WHILST LINKED TO SPC3D6
SELECTING A TOOL
Because you are connected to SPC3d6 the graphical interface of tool selection is more detailed. Here you can see the same tools that are available in Roaming Mode, but each tool now has a small graphic to help visualize the tools actions.
DISPLAYED RESULT
The GapGun MX+ handle displays a basic summary of the measurement. Because you are connected to and using SPC3d6 you should refer to the PC screen image for more accurate measurement detail.
Please see ‘Introduction’ page Error! Bookmark not defined., for an explanation of the icons at the bottom of the GapGun MX+ screen.
SPC3D6 MEASUREMENT WINDOW
Here you can see the equivalent measurement data displayed in SPC3d6. The information available is more comprehensive.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 27 SPC3d6.0
7.1 MEASUREMENT DIAGNOSTICS
MEASUREMENT TAKEN
Once you have taken a measurement there is also a small icon at the bottom of the screen (calculator) that allows the operator to view the diagnostics of the measurement.
Tap the small calculator icon to view the diagnostic screen.
MEASUREMENT DIAGNOSTIC MENU
Here you can see a graphical image of the measurement taken.
This icon is used for reference.
SPC3D6 MEASUREMENT WINDOW
The equivalent measurement data displayed in SPC3d6. The benefits of being connected to SPC3d are clear. You can see the average results and the information about where the measurement was taken. From here you can adjust the tool.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 28 SPC3d6.0
8 EXPORTING AND IMPORTING DATA
The GapGun MX+ will be used in Direct Link Mode, to update checkplans, save measurement data, change or erase information
stored on the GapGun MX+ handle you will need to connect to SPC3d6.
When the GapGun MX+ is connected to a PC running SPC3d6 these options are made available. Any Checkplan created in
SPC3d6 and saved on the PC will be available to use from SPC3d6 via the GapGun MX+ handle. Once the checkplan has been
opened along with any specific tools associated with that checkplan, the GapGun MX+ will use SPC3d6 to measure and record
measurement data in Direct Link Mode.
Please see Document D11-635 ‘GapGun MX+ Data Transfer Operator Guide’ for further help with data transfer.
For further help please see your administrator or contact [email protected].
9 LINKING TO SPC3D VIA LAN OR WI-FI
LINK TO SPC3D
Tap this option to link directly to SPC3d6. This option uses toolkits and checkplans stored on your PC. It does not download and store them on the GapGun MX+ handle.
These icons and link options will only be available in Direct Link Mode as you are connecting to a PC running SPC3d6. In Roaming
Mode these options will not be available. When you connect to SPC3d6 the GapGun MX+ goes into Direct Link Mode as it will
sync with all the checkplans and tools open or available via SPC3d6.
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 29 SPC3d6.0
For support with your GapGun MX+ please contact
Third Dimension
Brabazon Office Park, Bristol, BS34 7PZ, UK
T: +44 (0)3333 44 3000
F: +44 (0)3333 44 0041
www.third.com E: [email protected]
10 CONTACT THIRD DIMENSION
GapGun MX+ Direct Link Mode Operator Guide
© Third Dimension Confidential Document D11-608 Page 30 SPC3d6.0