dimensional drawing: et5551l...dimensional drawing: et5551l rev: b date: 09/14/2016 ms601862...
TRANSCRIPT
1267.5[49.90]
738.1[29.06]
1216[47.9]
BEZEL OPEN AREA
683.6[26.9]
BEZEL OPEN AREA
600[23.62]
600[23.62]
90.1[3.55]27.24
[1.07]
1209.6[47.62]
DISPLAY ACTIVE AREA
680.4[26.79]
DISPLAY ACTIVE AREA
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS [INCHES]
REMOTE OSD (1 INCLUDED WITH TOUCHMONITOR)P/N E483757
LIGHT SENSOR(IR MODEL)
VESA MOUNT PER MIS-F 600,600,6MM, MAX SCREW DEPTH = 10MM
CABLE SECURITY COVER
SEE DETAIL B
DETAIL BSCALE 0.500
AC POWER IN
REMOTE OSD
TOUCH USB
RS-232HDMI IN
DISPLAYPORT IN
HEADPHONE OUT
AUDIO LINE IN
COMPUTER MODULE (OPTIONAL)
CABLE SECURITY COVER (INCLUDED WITH COMPUTER MODULE KIT)
129[5.08]
25.5[1.0]
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS [INCHES]
MOUNTING INTERFACE FOR PERIPHERALSONE PER SIDE (FOUR TOTAL)
SEE DETAIL A
DETAIL ASCALE 1.000
PEEL OFF COVERS TO ACCESS PERIPHERAL MOUNTING SCREW HOLES AND POWER CABLE.
M3 THREADS, X2
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS
WALL MOUNTING
THERMAL RECOMMENDATIONSPORTRAIT AND LANDSCAPE ORIENTATION
MAINTAIN AMBIENT ROOM TEMPERATUREBELOW 40C
AIRFLOW DIRECTION
AIRFLOW DIRECTION
FLUSH MOUNTINGAIR BEHIND MONITOR MUST NEVER EXCEED40C DURING OPERATION. INSTALL VENTINGAND/OR FANSIN WALL STRUCTURE TO CIRCULATEAIR AND MAINTAIN SAFE OPERATING TEMPERATURE.
TOUCHMONITOR
WALL STRUCTURE
TOUCHMONITOR
WALL STRUCTURE
PRODUCT VENTING LOCATIONSDO NOT BLOCK DURING OPERATION
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS
THERMAL RECOMMENDATIONSTABLE-TOP ORIENTATION
WHEN MOUNTED IN TABLE-TOP ORIENTATION, DO NOT ALLOWAIR TEMPERATURE BELOW MONITOR TO EXCEED OPERATING TEMPERATURE SPECIFICATIONS.RECOMMENDATION: INSTALL AIR CIRCULATION DEVICES ABLE TO MONITOR AND CONTROLAIRSPACE TEMPERATURE UNDER THE TOUCHMONITOR SO IT WILL COMPLY WITHOPERATING TEMPERATURE SPECIFICATIONS
PRODUCT VENTING ALL AROUND MONITORMUST BE KEPT OPEN DURING OPERATION
TO MAINTAIN SAFE OPERATING TEMPERATURE
310.4[12.2]
310.4[12.2]
48.9[1.9]
54.7[2.2]
319.4[12.6]
45.7[1.8]
45.7[1.8]
313.9[12.4]
319.1[12.6]
54.7[2.2]
54.7[2.2]319.4
[12.6]
97.1[3.82]
DISTANCE OFF OF WALLAFTER MOUNTING
406.4[16.00]
609.6[24.00]
60[2.36]
50[1.97]
646[25.43]
628[24.72]
413.9[16.3]
413.9[16.3]
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS [INCHES]
OPTIONAL WALLMOUNT KITP/N E248743
MONITOR OUTLINELANDSCAPE ORIENTATION
MONITOR OUTLINEPORTRAIT ORIENTATION
7.9 [.3]DISTANCE ABOVE BEZEL
633.8[25.0]
RECOMMENDED PLACEMENT ON BOTTOM SIDE
DIMENSIONAL DRAWING: ET5551L
REV: BDATE: 09/14/2016
MS601862DIMENSIONS ARE IN MILLIMETERS
OPTIONAL RFID KIT P/N E031451
ANTENNA LOCATION