© Matthieu Masson 2000 • AES Laboratoire reserves the right to alter specifications without prior notice Save time and achieve total traceability by performing all 3 operations at once: weighing, dilution and recording. Performance The Dilumat ® 4 high performance system provides optimal dilution in strict compliance with international standard NF EN ISO 6887-1 and COFRAC specifications. Self-regulating weighing system featuring a drift alarm. Self-regulating dilution system featuring an anomaly warning message system. Self-regulating calibration, weighing test upon request, systematic performance validation test for all dilution operations. 20 customised weighing/dilution programmes with programmable security features (dilution factor, min/max weight, tolerance...). Optional barcode reader for sample, diluent and operator identification. Automatic selection of pump and diluent in accordance with the selected dilution programme. Dilution parameters instantly programmed on reading sample barcodes (optional). Sturdy one-piece cast aluminium frame for improved reading reliability. Sturdy, splash-proof, ergonomically-designed epoxy body-frame. Curved design for easy cleaning. Traceability Dilumat ® 4 provides total traceability for quality control purposes. Automatic sample, diluent and operator barcode identification (optional). Report tickets for total traceability (optional): date, time, date of last calibration setting, programme number and settings, diluent name and batch number, pump used, operator name, sample identification, sample weight, final weight, actual dilution factor. Data retrieval via PC connected to the RS232 outlet access (for use without Labmaster). LABMASTER Automatic piloting by PC for total traceability with optional network PCB and software. Dilumat ® 4 is designed to provide total traceability and productivity for industrial microbiology laboratories. Enjoy total security in compliance with your analysis proto- cols. Dilution duration for 250g: 10 to 15 seconds depending on the required accuracy (complete weighing, dilution and recording) Dilution factor: 1/2 to 1/50 Sample weighing accuracy: 0.1 g Programmable accuracy tolerance Min. sample weight: 1 g Max. weight: 1500 g Automatic calibration Self-regulated weighing Self-regulated dilution Automatic tare Operating temperature: 5 to 40° C Power: 110-240 V± 10% - 50/60 Hz - 100 W W x H x H: 500 x 500 x 500 mm Weight: 12 kg Ordering information: AESAP1056 Dilumat ® 4, gravimetric diluter complete with tubing set & bag holder Optional extras: AESDL0042A Star printer (labels) AESDL0106 built-in barcode reader AESDL0111 External barcode reader AESDL0108 Complete kit - second pump AESDL10045 Blender bowl support tray AESDL10098 125 mm height base AESDL10099 70 mm height base AESDL10002 80ml bag holder AESDL10107 Labmaster connection network PCB Disposables: AESDL0037 Tubing set AESD400/50G Sterile, irradiated bags, 50 x 50 pcs. AES400P/25G Sterile lateral filtering irradiated bags, 60 x 25 pcs. AESD100042C Star printer adhesive labels AESD100042B 114 mm-wide print-out paper Accessories: 3 to 19-litre capacity automated preparators (ideal for peptone buffered water, 1 / 2 Fraser, tryptone salt solution ) available on request. Route de Dol - BP 54 • 35270 Combourg - France Tel. : +33 (0)2 99 73 11 55 • Fax : +33 (0)2 99 73 15 89 e-mail : [email protected] http://www.aes-lab.com * Gravimetric diluter

Upload: innovation-diagnostics-inc

Post on 14-Mar-2016

214 views

Category:

Documents


0 download

DESCRIPTION

Ordering information: AESAP1056 Dilumat® 4, gravimetric diluter complete with tubing set & bag holder * Gravimetric diluter • Dilution duration for 250g: 10 to 15 seconds depending on the required accuracy (complete weighing, dilution and recording) © Matthieu Masson 2000 • AES Laboratoire reserves the right to alter specifications without prior notice

TRANSCRIPT

© M

atth

ieu

Mas

son

2000

• A

ES L

abor

atoi

re r

eser

ves

the

righ

t to

alte

r sp

ecifi

catio

ns w

ithou

t pri

or n

otic

e

Save time and achieve total traceability by performing all 3 operations at once:

weighing, dilution and recording.Performance• The Dilumat® 4 high performance system provides optimal

dilution in strict compliance with international standard NF EN ISO 6887-1 and COFRAC specifications.

• Self-regulating weighing system featuring a drift alarm.

• Self-regulating dilution system featuring an anomaly warning message system.

• Self-regulating calibration, weighing test upon request, systematic performance validation test for all dilution operations.

• 20 customised weighing/dilution programmes with programmable security features (dilution factor, min/max weight, tolerance...).

• Optional barcode reader for sample, diluent and operator identification.

• Automatic selection of pump and diluent in accordance with the selected dilution programme.

• Dilution parameters instantly programmed on reading sample barcodes (optional).

• Sturdy one-piece cast aluminium frame for improved reading reliability.

• Sturdy, splash-proof, ergonomically-designed epoxy body-frame. Curved design for easy cleaning.

Traceability• Dilumat® 4 provides total traceability

for quality control purposes.

• Automatic sample, diluent and operator barcode identification (optional).

• Report tickets for total traceability (optional): date, time, date of last calibration setting, programme number and settings, diluent name and batch number, pump used, operator name, sample identification, sample weight, final weight, actual dilution factor.

• Data retrieval via PC connected to the RS232 outlet access (for use without Labmaster).

• LABMASTERAutomatic piloting by PC for total traceability with optional network PCB and software.Dilumat® 4 is designed to provide total traceability and productivity for industrial microbiology laboratories.Enjoy total security in compliance with your analysis proto-cols.

• Dilution duration for 250g: 10 to 15 seconds depending on the required accuracy (complete weighing, dilution and recording)

• Dilution factor: 1/2 to 1/50• Sample weighing accuracy: 0.1 g• Programmable accuracy tolerance• Min. sample weight: 1 g• Max. weight: 1500 g• Automatic calibration• Self-regulated weighing• Self-regulated dilution• Automatic tare • Operating temperature: 5 to 40° C• Power: 110-240 V± 10% - 50/60 Hz - 100 W • W x H x H: 500 x 500 x 500 mm• Weight: 12 kg

Ordering information:AESAP1056 Dilumat® 4, gravimetric diluter complete with tubing set & bag holder

Optional extras:AESDL0042A Star printer (labels)AESDL0106 built-in barcode readerAESDL0111 External barcode readerAESDL0108 Complete kit - second pumpAESDL10045 Blender bowl support trayAESDL10098 125 mm height baseAESDL10099 70 mm height baseAESDL10002 80ml bag holderAESDL10107 Labmaster connection network PCB

Disposables:AESDL0037 Tubing set AESD400/50G Sterile, irradiated bags, 50 x 50 pcs.AES400P/25G Sterile lateral filtering irradiated bags, 60 x 25 pcs. AESD100042C Star printer adhesive labelsAESD100042B 114 mm-wide print-out paper

Accessories: 3 to 19-litre capacity automated preparators (ideal for peptone buffered water, 1 / 2 Fraser, tryptone salt solution ) available on request.

Route de Dol - BP 54 • 35270 Combourg - France

Tel. : +33 (0)2 99 73 11 55 • Fax : +33 (0)2 99 73 15 89

e-mail : [email protected]

http://www.aes-lab.com

* Gravimetric diluter

Total traceability: sample, diluent and operator for quality control purposes.

Alphanumeric operation report print out.

20 fully customisable programmes. Operation guide.

Solid, splash-proof and ergonomically-designed body: “both efficient and attractively designed”

Self-regulating automatic calibration system.

PC piloting and compatibility with

traceability software (optional).

Automatic, convenient

articulated arm. Particularly useful

for laminar flow cabinet.

Heavy-duty easy-loading peristaltic pump.

One piece cast aluminium frame for improved reading reliability.

Automatic pump selection.

Optional automatic barcode reader identification system: sample, diluent and operator.