dilation products - micromedical · dilation products cre ... achalasia balloon dilator •...

2
Dilation Products CRE FIXED WIRE BALLOON DILATOR Designed to produce three distinct diameters at three separate pressures during in vivo dilation. Rounded shoulders facilitate visualization of strictures while dilating. Proprietary manufacturing process using Pebax ® material. High pressure balloon is designed to produce little or no balloon waisting. Engineered for rapid deflation. MAXFORCE TTS SINGLE-USE BALLOON DILATOR Single-size balloon manufactured using PET material. Molded ball tip is designed to aid in navigation of tortuous anatomy. RIGIFLEX ® II SINGLE USE ACHALASIA BALLOON DILATOR Wireguided to facilitate access and help guide balloon through stricture. Radiopaque markers facilitate placement of the balloon. CRE WIREGUIDED BALLOON DILATOR Same features as a Fixed Wire Balloon plus a preloaded guidewire that is designed to: Facilitate placement within tight strictures and torturous anatomy. Reduce procedure time. 15mm 16.5mm 18mm

Upload: trinhkhue

Post on 06-May-2018

219 views

Category:

Documents


4 download

TRANSCRIPT

Dilation Products

CRE™ FIXED WIRE BALLOON DILATOR• Designed to produce three distinct diameters at three

separate pressures during in vivo dilation.• Rounded shoulders facilitate visualization of strictures

while dilating.• Proprietary manufacturing process using Pebax® material.• High pressure balloon is designed to produce little

or no balloon waisting.• Engineered for rapid deflation.

MAXFORCE TTS™ SINGLE-USEBALLOON DILATOR

• Single-size balloon manufactured using PET material.

• Molded ball tip is designed to aid innavigation of tortuous anatomy.

RIGIFLEX® II SINGLE USE ACHALASIA BALLOON DILATOR

• Wireguided to facilitate access and help guide balloon through stricture.

• Radiopaque markers facilitateplacement of the balloon.

CRE™ WIREGUIDED BALLOON DILATORSame features as a Fixed Wire Balloon plus a preloaded guidewire that is designed to:

• Facilitate placement within tight strictures and torturous anatomy.

• Reduce procedure time.

15mm

16.5mm

18mm

Indications, Contraindications, Warnings and Instructions for Use can be found in the product labeling supplied with each device.CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

Boston Scientific CorporationOne Boston Scientific PlaceNatick, MA 01760-1537www.bostonscientific.com

Ordering Information1.800.225.3226

© 2006 Boston Scientific Corporationor its affiliates. All rights reserved.

DVG1770 5M 5/06

Dilation Products

INFLATION SYSTEMSOrderNumber DescriptionM00550620 Alliance™ II Inflation HandleM00550601* Alliance II 60ml Single-Use Syringe/Gauge AssemblyM00553200 Achalasia Pneumatic Hand Pump and Monitor (not shown)

* Box 5

CRE™ SINGLE-USE FIXED WIRE BALLOON DILATORSOrder Inflated O.D. Balloon Inflation Minimum Working Catheter Working Number (mm) (Fr) Length (cm) Pressures (ATM) Channel (mm) Size (Fr) Length (cm)M00558330 6-7-8 18-21-24 8 3-6-10 2.8 6 180M00558340 8-9-10 24-27-30 8 3-5.5-9 2.8 6 180M00558350 10-11-12 30-33-36 8 3-5-8 2.8 6 180M00558360 12-13.5-15 36-40.5-45 8 3-4.5-8 2.8 6 180M00558370 15-16.5-18 45-49.5-54 8 3-4.5-7 2.8 6 180M00558380 18-19-20 54-57-60 8 3-4.5-6 2.8 6 180M00558361* 12-13.5-15 36-40.5-45 8 3-4.5-8 2.8 6 180M00558371* 15-16.5-18 45-49.5-54 8 3-4.5-7 2.8 6 180M00558381* 18-19-20 54-57-60 8 3-4.5-6 2.8 6 180

* Box 5

CRE SINGLE-USE WIREGUIDED ESOPHAGEAL/PYLORIC/COLONIC BALLOON DILATORSOrder Inflated O.D. Balloon Inflation Minimum Working Catheter Working Number (mm) (Fr) Length (cm) Pressures (ATM) Channel (mm) Size (Fr) Length (cm)Esophageal & PyloricM00558390 6-7-8 18-21-24 5.5 3-6-10 2.8 7.5 180M00558400 8-9-10 24-27-30 5.5 3-5.5-9 2.8 7.5 180M00558410 10-11-12 30-33-36 5.5 3-5-8 2.8 7.5 180M00558420 12-13.5-15 36-40.5-45 5.5 3-4.5-8 2.8 7.5 180M00558430 15-16.5-18 45-49.5-54 5.5 3-4.5-7 2.8/3.2* 7.5 180EsophagealM00558440 18-19-20 54-57-60 5.5 3-4.5-6 2.8/3.2* 7.5 180Esophageal, Pyloric & ColonicM00558450 6-7-8 18-21-24 5.5 3-6-10 2.8/3.2* 7.5 240M00558460 8-9-10 24-27-30 5.5 3-5.5-9 2.8/3.2* 7.5 240M00558470 10-11-12 30-33-36 5.5 3-5-8 2.8/3.2* 7.5 240M00558480 12-13.5-15 36-40.5-45 5.5 3-4.5-8 2.8/3.2* 7.5 240M00558490 15-16.5-18 45-49.5-54 5.5 3-4.5-7 2.8/3.2* 7.5 240Esophageal & ColonicM00558500 18-19-20 54-57-60 5.5 3-4.5-6 2.8/3.2* 7.5 240

* Requires a 2.8mm Olympus Brand Endoscope channel or a 3.2mm Pentax or Fujinon Brand Endoscope channel

MAX FORCE™ SINGLE-USE ESOPHAGEAL BALLOON DILATORS Order Inflated O.D. Balloon Inflation Minimum Working Catheter Size Working Number (mm) (Fr) Length (cm) Pressure (ATM) Channel (mm) (mm) (Fr) Length (cm)M00589060 6 18 6 10 2.8 2.0 6 180M00589080 8 24 6 10 2.8 2.0 6 180M00589100 10 30 6 7 2.8 2.0 6 180M00589120 12 36 6 7 2.8 2.0 6 180M00589140 14 42 6 7 2.8 2.0 6 180M00589150 15 45 6 5 2.8 2.0 6 180M00589160 16 48 6 5 2.8 2.0 6 180M00589180 18 54 6 5 2.8 2.0 6 180

RIGIFLEX® II SINGLE-USE ACHALASIA BALLOON DILATORS*Order Inflated O.D. Balloon Catheter Size Working Length RecommendedNumber (mm) (Fr) Length (cm) (mm) (Fr) (cm) Guidewire**M00554500 30 90 10 4.6 14 90 .038"M00554510 35 105 10 4.6 14 90 .038"M00554520 40 120 10 4.6 14 90 .038"

* Product shipped sterile. ** Guidewire included with Rigiflex II Balloon Dilation Catheter.