MineralScan MillSlicer Polar Plot Toe Position (PMC AG Mill Data). 0 o. 0 o. Mill Rotation. Mill Rotation. Under-filled Mill. Full Mill. 90 o. 90 o. Toe = 136 o. Real-time Toe Angle. Toe = 149 o. 180 o. 180 o. - PowerPoint PPT PresentationTRANSCRIPT
www.digitalcontrollab.com3701 NW 40th Terrace, Suite 1Gainesville, Florida 32606 USA
MineralScan MillSlicer Polar Plot Toe Position (PMC AG Mill Data)
Real-time ToeAngle
Under-filled Mill
Toe = 149o
Full Mill
Toe = 136o
Note: As the mill fills, the load shifts up on the liner. Toe Angle 0 degrees = 4 mA, Toe 360 degrees = 20 mA
Mill Rotation
Mill Rotation
Bearing Pressure
Mill Power
Water
Outlet Fill Level (green)
Inlet Fill Level (blue)
Shell Fill Level (teal)
Feed (red)
Toe = 149o
Toe = 136o
0o
90o
180o
0o
90o
180o
MillSlicer Toe Position Automatic Control Strategy
Bearing Pressure
Mill Power (black)
Water (light blue)
Feed (red)
Fill Level Signals:Shell
(teal) Inlet (dark
blue)Outlet
(green)
Toe = 152o
Toe = 145o
Basic Automatic Control Strategy:1. Empty mill start-up set-point for Toe Angle = 145o. Enter this set point and start auto-feed control. 2. As the mill fills, observe how bearing pressure & power increase over time (see trends).3A. If power or bearing pressure begin to reach their maximum limits, increase the toe set point. i.e. change toe angle set point from 145o to 147o. This should now reduce the feed and empty the mill.3B. If power or bearing pressure are significantly below their maximum limits, decrease the toe set point. i.e. change toe angle set point from 145o to 143o. This should now increase the feed and fill the mill.
Note: Upon start-up, it is recommended that the operator run the mill in manual control to more quickly bring the mill up to the desired power/pressure operating point and then switch to auto-control.