digital signal processing – chapter 7 sampling theory prof. yasser mostafa kadah
TRANSCRIPT
- Slide 1
- Slide 2
- Digital Signal Processing Chapter 7 Sampling Theory Prof. Yasser Mostafa Kadah
- Slide 3
- Textbook Luis Chapparo, Signals and Systems Using Matlab, Academic Press, 2011.
- Slide 4
- Sampling Motivation Many of the signals found in biomedical applications are analog If we wish to process these signals with a computer it is necessary to sample, quantize, and code them to obtain digital signals. Sampling in time + quantization in amplitude Sampling issues How to sample in time (sampling period) How to quantize in amplitude (number of bits)
- Slide 5
- Uniform Sampling Sampling function Periodic sequence of impulses of period T s Sampled signal:
- Slide 6
- Uniform Sampling Period = T s
- Slide 7
- Uniform Sampling Sampling in the frequency domain: Sampling
- Slide 8
- Sampling Rate Calculation Requirement: No Aliasing
- Slide 9
- Sampling Rate Calculation Nyquist criterion
- Slide 10
- Sampling Rate Calculation: Example
- Slide 11
- Reconstruction of the Original Continuous-Time Signal from Samples Assuming band-limited signal and sufficient sampling, original signal can be recovered by low-pass filtering
- Slide 12
- Sampling of Infinite Bandwidth Signals: Anti-Aliasing Filter Anti-aliasing filter: a low-pass filter applied to the input signal to make sure that the signal to be sampled has a limited bandwidth Applied in all practical analog-to-digital converters
- Slide 13
- Sampling of Modulated Signals Nyquist sampling rate condition applies to low-pass or baseband signal x(t) with maximum frequency max Consider a modulated signal x m (t)= x(t) exp(j c t) where x(t) is the baseband signal and exp(j c t) is the carrier with carrier frequency c >> max To avoid aliasing the shifting in frequency should be such that there is no overlapping of the shifted spectra: Independent of carrier frequency General case: s > B (Bandwidth of signal)
- Slide 14
- Sampling of Modulated Signals: Illustration 0 B X( ) 0 B s > B Xs()Xs() After Sampling
- Slide 15
- Sampling of Modulated Signals: Biomedical Examples Sampling in Magnetic Resonance Imaging (MRI) In 1.5T MRI, the signal frequency has a small bandwidth but carried on around 64 MHz Practical sampling rates used in many commercial systems is only 1 MHz. Sampling in pulsed-wave Doppler ultrasound (PWD) The ultrasound center frequency used is around 5-10 MHz and the Doppler shift around that center frequency is only a few kHz. Practical sampling in PWD is limited by physics to around 5-10 kSa/s and it is usually sufficient
- Slide 16
- Practical Aspects: Quantization and Coding Amplitude discretization of the sampled signal x s (t) is accomplished by a quantizer consisting of a number of fixed amplitude levels Quantization error Example: Doppler signal sampling Need at least 12-14 bits per sample Useful signal superimposed on large clutter can be lost if lower quantization resolution is used
- Slide 17
- Problem Assignments Problems: 7.1, 7.2, 7.5, 7.6, 7.7, 7.10, 7.11, Turn in problems marked in red as homework Partial Solutions available from the student section of the textbook web site