Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without noticeii | Digital Control Adapter Data Sheet
TABLE OF CONTENTS
1 Description and Key Features
2 Ordering Information
3 Mechanical Drawing and Wiring Specifications
4 Lutron® EcoSystem Protocol
5 DMX512-A-RDM Protocol
6 Wiring Diagrams
UL Recognized Component Dry or Damp Locations
Class 2 Input
Designed in California, USAAssembled in USA Designed in California, USA Assembled in USA
UL Recognized ComponentDry or Damp Locations Class 2 Input
UL Recognized Component Dry or Damp Locations
Class 2 Input
Lumenetix Inc. • 4742 Scotts Valley Dr. • Scotts Valley, CA 95066Lumenetix, araya5, Dynamic Dimming and SceneSet are registered trademarks of Lumenetix, Inc. © Lumenetix, Inc. 2019.
877.805.7284 • www.lumenetix.com • [email protected]
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice3 | Digital Control Adapter Data Sheet
DescriptionThe Digital Control Adapter (DCA) enables fixtures powered by araya
®5 LED modules to be controlled by standard lighting protocols.
The adapter converts standards-based lighting protocols to a digital link that connects to the araya5 modules.
The standards supported are:• EcoSystem by Lutron
®
• DMX512-A-RDM (including Bluetooth)
Key Features• 12V or 24V.
• Compatible with araya5 CTM1 color tuning modules, and DDM1 dynamic dimming modules.
• Enables Lutron EcoSystem and DMX512-A-RDM compatible product offerings.
• Each adapter is addressable.
• Controls continuous dimming from 100% - 1% in increments of 1%.
• Controls continuous color tuning from: – 1650-4000K — CTM1B, Bluetooth-integrated – 1650-8000K — CTM1C, Bluetooth-integrated
• Controls dimming from 3050K at full intensity to 1800K at 1% intensity: – DDM1B, Bluetooth-integrated – DDM1C, Bluetooth-integrated
• DMX adapter enables dimming, color tuning, hue and saturation features.
1 DESCRIPTION AND KEY FEATURES
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice4 | Digital Control Adapter Data Sheet
General Specifications and Ordering CodesPower
Connector Type 2 position Molex Pico-SPOX
Wire Size 24 AWG
Operating Voltage 12V DC to 24V DC
Absolute Maximum Voltage 28V DC
Power Consumption 0.25 W
Reverse Voltage Protection 40V DC
ESD protection Special handling not required
Environment
Operating Temperature 0° C to 65° C
Location Type Dry
Lutron® EcoSystem Input (DCA-1A)* (DISCONTINUED - NO LONGER AVAILABLE)
Connector Type Refer to “Wiring Specifications” Section
Wire Size 16 AWG solid wire (EcoSystem input); 24 AWG stranded wire (Lux output)
Wiring Class EcoSystem Input: Class 1 or Class 2; LX Output: Class 2
Line Voltage Miswire Protection 277V AC (EcoSystem Input)
Ordering Codes DDM0 / DDM1 (1800 - 3050K): 45.020.008.04 (EAECOS1; one channel)
CTM0 / CTM1: 45.020.008.05 (EAECOS2; two channel)
DMX Input (DCA-1B)* (DISCONTINUED - NO LONGER AVAILABLE)
Connector Type Refer to “Wiring Specifications” Section
Wire Size 24 AWG stranded wire (DMX input and Lux output)
Wiring Class DMX Input: Class 1 or Class 2; LX Output: Class 2
Ordering Codes DDM0 / DDM1 (1800 - 3050K); CTM0 / CTM1 (1650 - 4000K): 45.020.008.02 (EADDB-40-R)
CTM0 (2700 - 6000K): 45.020.008.03 (EADDB-60-R)
Lutron®
EcoSystem Input (DCA-2)**
Connector Type Refer to “Wiring Specifications” Section
Wire Size 24 AWG
Wiring Class EcoSystem Input: Class 1 or Class 2; DMX Output: Class 2
Line Voltage Miswire Protection 277V AC (EcoSystem Input)
Ordering Codes DDM1B and DDM1C (Bluetooth-integrated): 80.005.001.02 (EAECOS1-G2; one channel)
CTM1B and CTM1C (Bluetooth-integrated): 80.005.002.02 (EAECOS2-G2; two channel)
*LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE).
**DMX Output is used with CTM 1B, CTM1C and DDM 1C.
2 ORDERING INFORMATION
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice5 | Digital Control Adapter Data Sheet
Mechanical Drawing2X 4.83
.19
88.93.50
76.23.00
64.62.5
32.31.27
64.62.54
4.16
25.91.0
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFLUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN MILLIMETERSTOLERANCES:ANGULAR: MACH 0.5ONE PLACE DECIMAL 0.5TWO PLACE DECIMAL 0.15
INTERPRET GEOMETRICTOLERANCING PER: ASME Y14.5
MATERIAL
FINISH
SEE NOTES
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME LumenetixTITLE:
SIZE
BDWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
SHEET 1 OF 1
DO NOT SCALE DRAWING
2X 4.83.19
88.93.50
76.23.00
64.62.5
32.31.27
64.62.54
4.16
25.91.0
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFLUMENETIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUMENETIX IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY USED ON
APPLICATION
DIMENSIONS ARE IN MILLIMETERSTOLERANCES:ANGULAR: MACH 0.5ONE PLACE DECIMAL 0.5TWO PLACE DECIMAL 0.15
INTERPRET GEOMETRICTOLERANCING PER: ASME Y14.5
MATERIAL
FINISH
SEE NOTES
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATENAME LumenetixTITLE:
SIZE
BDWG. NO. REV
WEIGHT: SCALE: 1:1
UNLESS OTHERWISE SPECIFIED:
SHEET 1 OF 1
DO NOT SCALE DRAWING
Wiring Specifications
Pin Wire Color Pin Function Wiring Description
Lutron® EcoSystem
Interface(Input)
E1 VioletNon-polarized Bus Terminal
2 Position Terminal Block16 AWG solid wire
Lutron PN: C-CBL-216-GR-1E2 Violet / White
PowerP1 Red Power 12V DC or 24V DC (+) 2 Position Molex Pico-SPOX
Lumenetix PN: 28.002.001.01Length: 610 mm (24 inches)P2 Black Power Common (-)
Module Interface(LX or DMX Output)*
M1 N/A Reserved for future use
5 Position Molex Pico-SPOXLumenetix PN: 28.020.002.01Length: 610 mm (24 inches)
M2 N/A Reserved for future use
M3 Brown Digital Common
M4 Orange araya® Module Bus, Data -
M5Option-1: White with Orange Stripe
(Option-2: Green)araya® Module Bus, Data +
DMX Interface(Input)
D1 Option-1: Brown (Option-2: Black) Digital Common 3 Position Molex Pico-SPOX24 AWG stranded wire
Lumenetix PN Option-1: 28.020.001.02 (Lumenetix PN Option-2: 28.020.001.01)
Length: 610 mm (24 inches)
D2Option-1: White with Orange Stripe
(Option-2: Violet)DMX Data +
D3 Option-1: Orange (Option-2: Gray) DMX Data -
CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.
*LX Output is used with CTM Zero, CTM One, DDM Zero and DDM One (DISCONTINUED - NO LONGER AVAILABLE).
DMX Output is used with CTM 1B, CTM1C and DDM 1C.
EcoSystem Interface
E1 P1P2
M1M2
M3M4
M5E2
Module
Side view – araya®5 Digital Control Adapter
(Lutron® EcoSystem input)DCA-1A
Power
NOT USED
P1P2
M1M2
D2D3
M3M4
M5D1
ModulePower DMXNOT
USED
Side view – araya®5 Digital Control Adapter
(DMX input)DCA-1B
EcoSystem Interface
E1 P1P2
M1M2
M3M4
M5E2
ModulePower
NOT USED
Side view – araya®5 Digital Control Adapter
(Lutron® EcoSystem input)DCA-2
3 MECHANICAL DRAWING & WIRING SPECIFICATIONS
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice6 | Digital Control Adapter Data Sheet
4.1 Lutron® EcoSystem Protocol
4 WIRING DIAGRAMS LUTRON® ECOSYSTEM PROTOCOL
Lutron® EcoSystem Protocol
EcoSystem technology is a control method for LEDs that provides addressing of individual fi xtures and status feedback. This makes it easy to digitally assign one or many fi xtures without complicated wiring. This opens up an entire suite of energy-saving, system-monitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple.
The araya®5 modules attached to different interface boards can be controlled independently or assigned to a single group by the EcoSystem controller.
The EcoSystem control is responsible for saving any confi guration settings. Once an interface board is assigned a pair of addresses, assigned addresses are saved in NVRAM. During the EcoSystem discovery process, the user pairs the desired dimming control in the controller to the Dim channel address in the interface board. The same applies for the CCT channel.
• 1 pair 16AWG Eco Loop, 900 feet (fi eld wiring).
• Maximum of 64 addresses on each loop.
EcoSystem Control Systems (recommended list)*
Quantum System
HomeWorks QS
Grafi k Eye QS Control Unit with EcoSystem
EnergiSavr Node with EcoSystem
Power Module with EcoSystem
*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.
® Specif icat ion Submittal page
Job Name:
Job Number:
Model Numbers:
Power Module with EcoSystemR LQSE-2ECO-D EcoSystemR Controller
369611b 1 10.22.13
MU
X
CO
M
MU
X
QS ECO 1 ECO 2
Test PruebaTester
Ta > 65 ºC
L N
Patent: 7,391,297
500-
1553
7 R
ev. A
NEC® Class 2
NEC® Class 2IEC PELV
0,5 N•m (5 in-lbs) Ta ≤ 65 °C www.lutron.com
u
Z096
65/75 ºC Cu Al
Power Module with EcoSystem® | Módulo de Potencia con EcoSystem® | Module d’Alimentation avec EcoSystem®
LQSE-2ECO-D
243C IND.CONT.EQ.
8 mm
1.800.523.9466
+44.(0)20.7702.0657230 V~ 50/60 Hz 80 mA
120 V~ 50/60 Hz 120 mA
Power Module with EcoSystemR
The Power Module with EcoSystemR unit is a DIN-rail mounted EcoSystem® Loop controller for EcoSystemR ballasts, drivers and devices. It provides EcoSystemR Loop power and control for two independent EcoSystemR Loops with up to 64 ballasts or drivers each.
Features• Provides EcoSystemR Loop power for two loops
of EcoSystemR ballasts or drivers (up to 250 mA per loop).
• Power failure memory retains control unitprogramming in the event of a power loss.
• Includes QS Link for connection to aHomeWorksR QS system.
• Power Module with EcoSystemR unit can be used ina HomeWorksR QS system to control and managelight in an entire home or building.
Up to 64 devices on each loop for Eco-1, and up to 32 devices on each loop for Eco-2
QS Link
Eco Loop 1
Eco Loop 2Fixture*
Power Module
Power Module with EcoSystem®
HomeWorksR QS Processor
GRAFIK EyeR QS
QS Contact Closure Interface
HomeWorksR QS Wallstation
120 / 230 V~ Control Power Up to 100
total QS devices
QS Power Supply
SivoiaR QS Shade / Drapery
Lutron EcoSystem Example
Fixture*
Fixture* Fixture*
*Fixture refers to a luminaire with one Lumenetix module, and with one address (DDM) or two addresses (CTM).
1
Lutron EcoSystem Controller Example
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice7 | Digital Control Adapter Data Sheet
4 WIRING DIAGRAMS
4.1.1 Lutron® EcoSystem Field Wiring
LUTRON® ECOSYSTEM PROTOCOL
Lutron® EcoSystem Field Wiring
• EcoSystem Digital Loop can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring fl exibility..
• The Loop is polarity insensitive and can be wired in any topology..
• Consult all national and local electrical codes for separation requirements..
Wire Gauge Maximum EcoSystem-Compliant Loop Wire Length
4.0 mm2 (12 AWG) 671 m (2200 ft)
2.5 mm2 (14 AWG) 427 m (1400 ft)
1.5 mm2 (16 AWG) 275 m (900 ft)
1.0 mm2 (18 AWG) 175 m (570 ft)
Drain Wire ConnectionsDrain wire connections are required as follows.
Shielding
To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.
Method-1
A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.
Method-2
A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice8 | Digital Control Adapter Data Sheet
4 WIRING DIAGRAMS
4.2 DMX512-A Protocol
DMX512-A PROTOCOL
DMX512-A is an acronym for Digital Multiplex, a communication protocol used to remotely control lighting dimmers and intelligent fi xtures. It is designed to provide a common communications standard between these lighting devices regardless of the manufacturer. The 512-A after the DMX refers to the number of control channels used on one network segment (often called a ‘universe’) of devices. In a simple dimming system, one channel controls the intensity of the fi xture. A single intelligent fi xture such as the araya5 requires several channels to control its various parameters (one channel each for DIM,
CCT, SAT, HUE).
DMX512A Specifi cations:• DMX 512-A (Controller).
• A universe is 512 Channels.
• DMX value is between 0 and 255, where 0 is off and 255 is full on.
• The maximum number of devices in a daisy-chain wire run is 32, which include the controller and opto-splitter.
• The maximum network wire run is a distance of up to 1600 feet for non-RDM systems and up to 1000 feet for RDM systems.
• One device functions as the master (DMX controller) on a network, while the rest function as slaves (mergers, splitters, intelligent fi xtures, etc.).
• Only the controller (master) transmits over the network, and all fi xtures receive the same data.
• The fi nal device in the daisy-chain must be terminated with a 120 ohm resistor between DMX+ and DMX- pins.
• It is recommended that the terminator for the fi nal device be located in the control panel, if it falls within the recommended wiring distance.
• All wiring must be in a continuous run and daisy-chained.
• Star wiring is only allowed in conjunction with an opto-splitter.
• Do not run DMX control cable in close proximity to AC power lines. EM spikes from switching of high-current devices such as HVAC equipment or generators will induce noise into the DMX cable.
• The shield must be carried through between modules and properly grounded at one point only.
• Connections to DMX512-A-RDM accessory board: wire size to be 24AWG, and solid or stranded cables may be used. Stranded wire used must be tinned or installed with ferule connector.
RDM
DMX512-A control protocol that enables Remote Device Management for two-way communications for confi guration, monitoring and system setup. Allows two way communication between lighting controller and the fi xtures. Allows for remote setting of DMX start addressing. RDM signals are sent back the other way, but not constantly. Controller can ask one or more devices for query feedback. RDM packets are inserted in-between the existing DMX data packets being used to control the lighting. The DMX Control Console will broadcast up to 512 channels over one DMX cable (max. run of 1000 feet for RDM). Some of these channels may not be used, but will still be transmitted, as required by the protocol. It must be set to a desired channel (001, 002. 003. 004, etc.) to control the connected light fi xture. This is usually accomplished using RDM. This desired ‘channel’ is commonly known as the DMX address. When addressing fi xtures, it is not recommended to skip addresses.
When RDM is not available with the control system, it is permissible to use the Lumenetix commissioning tool (the araya5 Tunable Color 2.0 iOS App) to set
the address of the slots. The instructions to confi gure the DMX channels can be found in the separate araya5 Tunable Color Instruction Manual.
The DMX512-A interface follows the ANSI E1.11-2008 (R21013) standard. Four address slots are allocated to each interface board and control the Dim
level, CCT, Saturation and Hue of the araya5 modules connected to the board.
Default DMX512-A Slot Allocation:
Slot Function
1 Dim Level
2 CCT
3 Saturation Level
4 Hue
DMX512-A Protocol
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice9 | Digital Control Adapter Data Sheet
4.2.1 DMX512-A Electrical Specifications
4 WIRING DIAGRAMSDMX512-A PROTOCOL
DMX512-A Electrical Specifi cations
Parameter Range Remarks
ESD Protection ±15KV (air), ±8KV (conducted) Per IEC 61000-4-2
Termination Recommended The DMX512 bus termination rules apply
Directionality Receive only
Frequency stability ±20ppm
Load per port 1/256 1/8 of Nominal RS-485
Isolation 3KVrms
DMX512-A Control Systems (recommended list)Choreo
Cognito
Crestron Greenlight System
Entec
ETC Mosaic
ETC Paradigm
Fresco
Interactive Technologies
Lutron HomeWorks QS
Lutron Quantum
Nicolaudie
Pathway Connectivity
Pharos
Traxon Ecue
Vantage Controls
*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list.
DMX512-A Recommended Internal / Field Wiring
TMB Cable ProPlex DMXPC224T: 2-pair DMX512 cable, overall foil and braid shielding with drain wire. UV and fungus resistant. Fully rated for installations, yet easy
handling for light duty portable applications.
PC224TW: Same as above, with white jacket.
For use as DMX in/out under one jacket:
PC244T: Two individually shielded pairs and drain wires. UV resistant. Color coded foil shielding for easy reference.
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice10 | Digital Control Adapter Data Sheet
4 WIRING DIAGRAMS
4.2.2 DMX512-A Recommended Field Wiring
DMX512-A PROTOCOL
DMX512-A Recommended Field WiringLiberty 24-2P-485 (Non-Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (Wago, XLR and PHX connectors)Liberty 24-2P-P485 (Plenum), 24 AWG, 2 pair dual 120 ohm, 11.2 pf/ft low capacitance (XLR and PHX connectors)Belden #9842 (Non-Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors)Belden #89842 (Plenum), 24 AWG, 2 pair dual shielded 120 ohm, 12.8 pf/ft low capacitance (XLR and PHX connectors)
Please refer to wire manufacturer’s lighting catalog for and/equals as required by code.
Category Wire or EqualThe Entertainment Services and Technology Association (ESTA) does not defi ne a maximum run length for DMX over Cat5 since many factors will affect the maximum run length, such as number of devices, number of splices in the cable, the strength of the DMX transmitter(s), if Remote Device Management (RDM) is being used, and sources of interference. ESTA does state (again, in ANSI E1.21-2):
“A properly selected and installed DMX512 cable should provide acceptable signal strength for runs of 300m (1000ft). Please note that the technical requirements, such as run-length and topology for other networking technologies, such as Ethernet, should be considered if using the installed cable for another networking technology in the future is anticipated.”
Cat5 or equivalent is not preferred as a portable cable since it is not as rugged as other DMX cables. Male RJ45 connectors are especially prone to breakage over repeated re-connections.
LUMENETIX RECOMMENDATION:
CAT 5E -150 FEET
CRESTRON
DM-CBL-8G-NP
DM-CBL-8G-P
CAT 7- 330 FEET
CRESTRON
DM-CBL-ULTRA-NP
DM-CBL-ULTRA-P
DMX512-A Recommended Field Connectors (or Equal)WAGO 221
PHOENIX CONTACT
XLR NEUTRIK
CRESTRON
RJ45 DM -8G-CONN
RJ45 IDC DM-CONN
DMX512-A Wiring Connections
Signal Description Pin Colors (4-Pair Cable) Pin Colors (2-Pair Cable)3-pin XLR connector
5-Pin XLR connector
5-Pin PHX connector
Signal Common White/Brown and Brown White/Blue and Blue 1 1 1
Data (-) Primary Data Link Orange Orange 2 2 2
Data (+) Primary Data Link White/Orange White/Orange 3 3 3
Data2 (-), or not used Optional Secondary Data Link 4 4
Data2 (+), or not used Optional Secondary Data Link 5 5
RJ-45 Connector Pin-Out (T568B)XLR Connectors (5-Pin)
+-
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice11 | Digital Control Adapter Data Sheet
4 WIRING DIAGRAMS
4.2.3 DMX512-A Controller Example
DMX512-A PROTOCOL
DMX512-A Drain Wire Connections
Drain wire connections are required as follows.
Shielding
To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the fi eld. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate.
Method-1
A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the fi eld end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop.
Method-2
A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop.
DMX512-A Controller Example
Up to 30devices on each loop
Bus
DMX Loop 1
DMX Loop 2
Power Module
DMXController
Processor TouchPanel
Contact Closure Interface
Wallstation
120 / 230 V~
Control Power total devices
Power Supply
Shade / Drapery
DMX512A Example
RDM Merger / Splitter
*Fixture refers to a luminaire with one Lumenetix module, and with one address (DDM) or four addresses (CTM).
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice12 | Digital Control Adapter Data Sheet
4.3.1 Lutron® EcoSystem Input; DCA-1A (24V DC)
DDM0 (one channel); CTM0 (two channel)
4 WIRING DIAGRAMSLUTRON® ECOSYSTEM WIRING DIAGRAMS
Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM0 (one channel) / CTM0 (two channel) — 24V
CTM0DDM0
24V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
e
PN: 28.002.001.01 Digital Control Adapter
PN: 28.002.001.01
PN: 28.020.002.01
Line in Voltage(refer to power supply)
PN: 28.002.002.01
White/Blue and Gray/Violet0-10V wires are tied together
Whi
te /
Ora
nge
JUNCTION BOX
FIXTURE
The Constant Hot/Live must not be wired to a switching device. This may be put on a relay for maintenance.
NOT USED
E1Lutron EcoSystem Controller
E2
Viol
et
Whi
te /
Viol
et
Strip
es
Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.
Adapter is con�gured at OEM factory for EcoSystem inputs.
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
Notes:
1. 24V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for EcoSystem inputs.
4. DCA may be installed in the luminaire only.
5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.
6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.
7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.
8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K and 2700 - 6000K.
9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.
10. LX Output used with this system.
DCA-1A A
ND DCA-1
B DIS
CONTINUED
-
NO LONGER
AVAILABLE
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice13 | Digital Control Adapter Data Sheet
4.3.2 Lutron®
EcoSystem Input; DCA-1A (12V DC) DDM1 (one channel); CTM1 (two channel)
4 WIRING DIAGRAMSLUTRON® ECOSYSTEM WIRING DIAGRAMS
Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1 (one channel) / CTM1 (two channel) — 12V
12V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
eW
hite
/ O
rang
e
PN: 28.002.001.01
PN: 28.002.002.01
Digital Control Adapter
PN: 28.002.001.01
CTM1DDM1
Line in Voltage(refer to power supply) The Constant Hot/Live must not be
wired to a switching device. This may be put on a relay for maintenance.
White/Blue and Gray/Violet 0-10V wires are tied together
JUNCTION BOX
FIXTURE
NOT USED
E1Lutron EcoSystem Controller
E2
Viol
et
Whi
te /
Viol
et
Strip
es
Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.
Adapter is con�gured at OEM factory for EcoSystem inputs.
PN: 28.020.002.01
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
Notes:
1. 12V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for EcoSystem inputs.
4. DCA may be installed in the luminaire only.
5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.
6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.
7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.
8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K.
9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.
10. LX Output used with this system.
DCA-1A A
ND DCA-1
B DIS
CONTINUED
-
NO LONGER
AVAILABLE
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice14 | Digital Control Adapter Data Sheet
4.4.1 DMX Input; DCA-1B (24V DC) DDM0; CTM0
4 WIRING DIAGRAMS
DMX Input; Digital Control Adapter (DCA)DDM0 / CTM0 — 24V
DMX512-A WIRING DIAGRAMS
Notes:
1. 24V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs.
4. DCA may be installed in the luminaire only.
5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damagethe Digital Control Adapter unit.
6. LX Output used with this system.
CTM0DDM0
24V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
e
PN: 28.002.001.01 Digital Control Adapter
PN: 28.002.001.01
PN: 28.020.002.01
Line in Voltage(refer to power supply)
PN: 28.002.002.01
White/Blue and Gray/Violet0-10V wires are tied together
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
Whi
te /
Ora
nge
NOT USED
For DMX inputs:OPTION-1Brown is Digital Common.White with Orange Stripe is Data Positive.Orange is Data Negative.
DMX (incl. Bluetooth)
PN Option-1: 28.020.001.02PN Option-2:28.020.001.01
Brow
n
Ora
nge
JUNCTION BOX
Whi
te /
Ora
nge
FIXTURE
The Constant Hot/Live must not be wired to a switching device. This may be put on a relay for maintenance.
OPTION-2Black is Digital Common.Violet is Data Positive.Gray is Data Negative.
DCA-1A A
ND DCA-1
B DIS
CONTINUED
-
NO LONGER
AVAILABLE
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice15 | Digital Control Adapter Data Sheet
4.4.2 DMX Input; DCA-1B (12V DC) DDM1; CTM1
4 WIRING DIAGRAMS
DMX Input; Digital Control Adapter (DCA)DDM1 / CTM1 — 12V
DMX512-A WIRING DIAGRAMS
Notes:
1. 12V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for DMX (including Bluetooth) inputs.
4. DCA may be installed in the luminaire only.
5. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.
6. LX Output used with this system.
12V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
eW
hite
/ O
rang
e
PN: 28.002.001.01
PN: 28.002.002.01
Digital Control Adapter
PN: 28.002.001.01
CTM1DDM1
PN: 28.020.002.01
Line in Voltage(refer to power supply) The Constant Hot/Live must not be
wired to a switching device. This may be put on a relay for maintenance.
White/Blue and Gray/Violet 0-10V wires are tied together
DMX (incl. Bluetooth)
NOT USED
Brow
n
Ora
nge
JUNCTION BOX
FIXTURE
Whi
te /
Ora
nge
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
For DMX inputs:OPTION-1Brown is Digital Common.White with Orange Stripe is Data Positive.Orange is Data Negative.
PN Option-1: 28.020.001.02PN Option-2:28.020.001.01
OPTION-2Black is Digital Common.Violet is Data Positive.Gray is Data Negative.
DCA-1A A
ND DCA-1
B DIS
CONTINUED
-
NO LONGER
AVAILA
BLE
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice16 | Digital Control Adapter Data Sheet
4.5.1 Lutron®
EcoSystem Input; DCA-2 (24V DC) DDM1C, Bluetooth-integrated (one channel) CTM1C, Bluetooth-integrated (two channel)
4 WIRING DIAGRAMSLUTRON
® ECOSYSTEM WIRING DIAGRAMS
Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1C (one channel) / CTM1C (two channel) — 24V
24V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
eW
hite
/ O
rang
e
PN: 28.002.001.01
PN: 28.002.002.01
Digital Control Adapter
PN: 28.002.001.01
CTM1DDM1
Line in Voltage(refer to power supply) The Constant Hot/Live must not be
wired to a switching device. This may be put on a relay for maintenance.
JUNCTION BOX
FIXTURE
NOT USED
E1Lutron EcoSystem Controller
E2
Viol
et
Whi
te /
Viol
et
Strip
es
Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.
Adapter is con�gured at OEM factory for EcoSystem inputs.
PN: 28.020.002.01Minimum requirement is a DMX type wire.
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
White/Blue and Gray/Violet 0-10V wires can be tied together or left open.
Notes:
1. 24V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.
4. DCA may be installed in the luminaire only.
5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.
6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.
7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.
8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K.
9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.
10. DMX Output used with this system.
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice17 | Digital Control Adapter Data Sheet
4.5.2 Lutron®
EcoSystem Input; DCA-2 (12V DC) DDM1C, Bluetooth-integrated (one channel) CTM1C, Bluetooth-integrated (two channel)
4 WIRING DIAGRAMSLUTRON
® ECOSYSTEM WIRING DIAGRAMS
Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1C (one channel) / CTM1C (two channel) — 12V
12V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
eW
hite
/ O
rang
e
PN: 28.002.001.01
PN: 28.002.002.01
Digital Control Adapter
PN: 28.002.001.01
CTM1DDM1
Line in Voltage(refer to power supply) The Constant Hot/Live must not be
wired to a switching device. This may be put on a relay for maintenance.
White/Blue and Gray/Violet 0-10V wires can be tied together or left open.
JUNCTION BOX
FIXTURE
NOT USED
E1Lutron EcoSystem Controller
E2
Viol
et
Whi
te /
Viol
et
Strip
es
Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.
Adapter is con�gured at OEM factory for EcoSystem inputs.
PN: 28.020.002.01Minimum requirement is a DMX type wire.
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
Notes:
1. 12V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.
4. DCA may be installed in the luminaire only.
5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.
6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.
7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.
8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 8000K.
9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.
10. DMX Output used with this system.
Digital Control Adapter
Revised 10.22.19 | Specifications subject to change without notice18 | Digital Control Adapter Data Sheet
4.5.3 Lutron®
EcoSystem Input; DCA-2 (12V DC) DDM1B, Bluetooth-integrated (one channel) CTM1B, Bluetooth-integrated (two channel)
4 WIRING DIAGRAMSLUTRON
® ECOSYSTEM WIRING DIAGRAMS
Lutron EcoSystem Input; Digital Control Adapter (DCA)DDM1B (one channel) / CTM1B (two channel) — 12V
12V DC, Class 2 AC to DC Power Supply
+ –
Neutral Hot
Red
Blac
k
Blac
k
Whi
te
Brow
nO
rang
eW
hite
/ O
rang
e
PN: 28.002.001.01
PN: 28.002.002.01
Digital Control Adapter
PN: 28.002.001.01
CTM1DDM1
Line in Voltage(refer to power supply) The Constant Hot/Live must not be
wired to a switching device. This may be put on a relay for maintenance.
White/Blue and Gray/Violet 0-10V wires are tied together
JUNCTION BOX
FIXTURE
NOT USED
E1Lutron EcoSystem Controller
E2
Viol
et
Whi
te /
Viol
et
Strip
es
Fixture manufacturer to provide minimum 18 AWG ofLutron EcoSystem wire tail (labeled E1 and E2) to junction box.Consult Lutron for �eld wiring.
Adapter is con�gured at OEM factory for EcoSystem inputs.
PN: 28.020.002.01
Brown is Digital Common.Orange is Data Negative.White with Orange Stripe is Data Positive.NOTE: This wire may be shipped in GREEN color in some existing versions of this cable assembly.
Notes:
1. 12V power (red/black) is Class-2 rated.
2. Module Data +/- (white with orange stripe/orange) to araya®5 modules is Class-2 rated.
3. Adapter is confi gured at factory for EcoSystem inputs. The araya5 Tunable Color 2.0 iOS App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.
4. DCA may be installed in the luminaire only.
5. One EcoSystem address (1 channel for warm-dim) per DDM module/DCA kit.
6. Two EcoSystem addresses (1 channel for CCT control and 1 channel for dimming control) per CTM module/DCA kit.
7. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control.
8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 1650 - 4000K.
9. CAUTION: The power cable should ONLY be plugged into the 2-pin power receptacle provided. Insertion of the cable into any other slot will damage the Digital Control Adapter unit.
10. DMX Output used with this system.
Lumenetix Inc.4742 Scotts Valley DriveScotts Valley, CA 95066877.805.7284www.lumenetix.com