diagnostic tools - maryland metrics 'home page

20
URREA's line of diagnostic tools use state-of-the-art technology in order to offer devices to measure, verify, and perform diagnosis, with an excellent balance of accuracy, speed, and versatility. URREA's diagnostics line is classified in 5 product categories: • Digital Multimeters • Automotive Digital Multimeters • Clamp-on Digital Multimeters • Accessories • Infrared Thermometers Digital Multimeters perform standard electrical tests in DC and AC circuits –including frequency, cycle frequency and wave amplitude– and take digital readings of voltage, amperage, and resistance of systems, components, and conductors. They are simply better and easier to read, handle and adjust than Analog Multimeters. They are designed to help service A/C, heating and cooling systems, electric equipment, appliances, computer equipment, electric motors, electrical, and electronic devices, and computers in general. Automotive digital multimeters are very efficient tools used to diagnose most problems in today's sophisticated automotive electronic systems. Their solid construction allows them to be used in the rough and high-paced environments of auto shops. Great for diagnosis on all makes, models, and types of vehicles. View readings from RPM activity cycles, DC and AC volts, resistance, frequency, pulse duration, dwell and min-max endpoints in an easy to navigate system. Clamp-on Digital Multimeters are designed to allow the user to measure current in AC/DC and high power circuits, outputs and derivations in transformers, capacitors, rectifiers, transmission lines, substations conductors, etc., where a conventional device cannot be used. They also measure current, resistance, amperage, voltage, conductivity, power factor, AC frequency, among other things without interrupting the connections and energy in the circuit. Thanks to their resistant build they are sufficiently strong to endure the exacting requirements in the transmission and generation of electricity. URREA also offers various accessories for its multimeter line: interface cables, test probes, alligator clamps and temperature sensors. URREA's line of infrared thermometers are ideal for MRO applications, electrical maintenance, automotive repairs and maintenance, manufacturing processes, food processing, A/C maintenance and any other application requiring temperature monitoring. Their accuracy remains constant for a long time. They have various features like auto off to conserve energy, a large DS radius and the ability to obtain readings in Celsius or Fahrenheit. The information presented in this chapter is organized as follows: Quick reference tables. Detailed product specifications. Safety recommendations TOOLS DIAGNOSTIC Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

Upload: others

Post on 03-Feb-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

URREA's line of diagnostic tools use state-of-the-art technology in order to offer devices to measure, verify, and perform diagnosis, with an excellent balance of accuracy, speed, and versatility.

URREA's diagnostics line is classified in 5 product categories:

• Digital Multimeters

• Automotive Digital Multimeters

• Clamp-on Digital Multimeters

• Accessories

• Infrared Thermometers

Digital Multimeters perform standard electrical tests in DC and AC circuits –including frequency, cycle frequency and wave amplitude– and take digital readings of voltage, amperage, and resistance of systems, components, and conductors. They are simply better and easier to read, handle and adjust than Analog Multimeters. They are designed to help service A/C, heating and cooling systems, electric equipment, appliances, computer equipment, electric motors, electrical, and electronic devices, and computers in general.

Automotive digital multimeters are very efficient tools used to diagnose most problems in today's sophisticated automotive electronic systems. Their solid construction allows them to be used in the rough and high-paced environments of auto shops. Great for diagnosis on all makes, models, and types of vehicles. View readings from RPM activity cycles, DC and AC volts, resistance, frequency, pulse duration, dwell and min-max endpoints in an easy to navigate system.

Clamp-on Digital Multimeters are designed to allow the user to measure current in AC/DC and high power circuits, outputs and derivations in transformers, capacitors, rectifiers, transmission lines, substations conductors, etc., where a conventional device cannot be used. They also measure current, resistance, amperage, voltage, conductivity, power factor, AC frequency, among other things without interrupting the connections and energy in the circuit. Thanks to their resistant build they are sufficiently strong to endure the exacting requirements in the transmission and generation of electricity.

URREA also offers various accessories for its multimeter line: interface cables, test probes, alligator clamps and temperature sensors.

URREA's line of infrared thermometers are ideal for MRO applications, electrical maintenance, automotive repairs and maintenance, manufacturing processes, food processing, A/C maintenance and any other application requiring temperature monitoring. Their accuracy remains constant for a long time. They have various features like auto off to conserve energy, a large DS radius and the ability to obtain readings in Celsius or Fahrenheit.

The information presented in this chapter is organized as follows:

• Quickreferencetables.

• Detailedproductspecifications.

• Safetyrecommendations

TOOLSDIAGNOSTIC

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

598597

599599

AUTOMOTIVE DIGITAL MULTIMETERS

CLAMP-ON DIGITAL MULTIMETERS

ACCESSORIES INFRAREDTHERMOMETERS

595594

DIGITALMULTIMETERS

BOROSCOPE

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

590

pv=PURE VOLTAGE

FUNDAMENTAL 60 Hz

PURE SINE WAVE GRAPH

REAL SINUSOIDAL CURVE GRAPH

This measurement method does not detect distortions generated by voltage differences in a circuit.

1st. Harmonic 2nd. HarmonicSINE WAVE GRAPH SINE WAVE GRAPH

DISTORTION DISTORTION120 Hz 240 Hz

DIFFERENCE OR NON-LINEAR LOADS

RMS= ROOT MEDIUM SQUARE

INTRODUCTION DIFFERENCE BETWEEN RMS AND TRUE RMS

REPRESENTED ON SINUSOIDAL GRAPHSIs the ability to measure and detect alternating voltage.

Is the ability to measure and detect voltages composed of harmonics (distortions in the size of the sine wave). That is, it measures the amount of distortion in the sinusoidal AC line caused by non-linear (inductive or capacitive) loads connected to a circuit.

RMS

TRUE

RMS

Important diagnostic equipment measurement characteristic.

DIAGNOSTIC EQUIPMENTASSORTMENT

DIGITALMULTIMETERSDigital multimeters are devices used for taking readings of voltage, amps and impedance, among others.UDXX AND UD1XX

DIGITAL AUTOMOTIVEMULTIMETERSDesigned to view readings directly on activity cycles.UD8X

CLAMP-ONMULTIMETERS

DIAGNOSTIC EQUIPMENTACCESSORIES

INFRAREDTHERMOMETERS

Used for taking precise measurements of current, starting current, voltage, etc.UD3XX

Allow you to store information and protect your device.UDXXXX

Long-lasting reading accuracy.Laser view may be turned on or off.UDXX

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

591

EQUIPMENT

DIAGNOSTIC

15

DIAGNOSTIC EQUIPMENTQUICK SELECTION GUIDE

DIGITAL MULTIMETERS

CountsAutomatic and manual rangeBacklit DisplaySpecial FeaturesAnalog barFrecuency measurementRelative modeContinuity alarmData captureMaximum and minimum captureFuse-protected 10A rangeCapacitanceTrue RMS (Volts CA)Diode testTemperatureFunctionsVolts CDMaximum DC VoltageBasic accuracy %Maximum Resolution µVVolts ACMaximum AC VoltageBasic accuracy %Maximum resolution µACapacitanceTemperatureBandwidth, HzAmperage AC and DCMaximum Resolution µAMaximum AmperageResistance Maximum Resolution mMaximum resistance M

2000

4000

2000 4000 5000 4000 4000

UD12

600V1.5100

600V1.5100

200

10020

UD18

750V0.9100

750V1.9100

200

10020

UD77

1000V0.5100

750V0.81000

450

0.110

10032

UD85

1000V0.3100

750V0.751000

5K

0.110

10040

UD87

1000V0.110

1000V0.5100

50K

0.110

1050

UD112

1000V0.510

1000V0.75100

400

0.110

1040

UD179

1000V0.5100

1000V0.75100

20K

0.110

10040

0.01 nF to 9,999µF 0.01 nF to 100µF 0.001nF to 5mF 0.01 nF to 100µF-40°C to 1370°C -50°C to 1300°C -40°C to 1300°C

PRODUCT CODES

595PAGE

595PAGE

596PAGE

596PAGE

596PAGE

596PAGE

596PAGE

URREA tools are designed to offer

precision, quality, and endurance.

They are manufactured by highly-

qualified and skilled employees.

Our tools are marked with the

manufacturing country of origin,

following the strictest quality

standards.

THE BEST WARRANTY

www.urreaprofessionaltools.com

(800) 366-6911PNEUMATIC TOOLSHAND TOOLS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

592

DIAGNOSTIC EQUIPMENT QUICK SELECTION GUIDE

AUTOMOTIVE DIGITAL MULTIMETERS

CountsAutomatic and manual rangeBacklit screenSpecial featureAnalog barFrequency measurement Continuity alarmData captureMaximum and minimum captureFuse-protected 10A rangeCapacitanceTrue RMS (Volts AC)TemperatureRS-232C communicationAutomotive functionsDuty cycle range, %Pulse width, mSDirect Dwell reading RPM Measurement using inductive collectorRPM Measurement using test tipsAdjustable trigger for stable RPM readings IP RPMs (times)IG RPM (cylinders)FunctionsVolts CDMaximum DC voltageBasic accuracy, %Maximum resolution µVVolts ACMaximum AC VoltageBasic accuracy, %Maximum resolution, µVCapacitanceTemperatureBandwidth, HzAmperage AC and DCMaximum resolution, µAMaximum amperageResistance Maximum resolutión mMaximum resistance M

4000 4000 4000

UD84

••••

0 - 99.90.002 - 1999.9

0 - 356.4•

4 steps30 - 9000

600V0.5100

600V0.751000

50K

0.110

10040

UD86

••••

••

0 - 99.90.002 - 1999.9

0 - 356.4••

30 - 900060 - 12000

750V0.3100

750V1

1000

400

0.110

10040

UD88

••

••••••••••

0 - 99.90.002 - 1999.9

0 - 356.4••

7 pasos30 - 9000

60 - 12000

1000V0.3100

750V0.751000

20K

0.110

10040

0.001µF to 999µF-40 °C to 1370 °C-40 °C to 1370 °C-40 °C to 1370 °C

PRODUCTS CODE

597PAGE

597PAGE

597PAGE

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

593

EQUIPMENT

DIAGNOSTIC

15

DIAGNOSTIC EQUIPMENTQUICK SELECTION GUIDE

DIGITAL CLAMP-ON MULTIMETERS

Counts Automatic and manual range True RMSSpecial featuresAnalog barFrequency measurementContinuity alarmData captureMaximum and minimum captureDiode testPower-On-Self-TestReal power (KW)Apparent power (KVA)Reactive power (KVAR)Power factor (cos )Energy integratorFunctionsVolts DCMaximum voltage DCBasic accuracy, %Maximum resolution, VVolts ACMaximum voltage ACBasic accuracy, %Maximum resolution, VBandwidth, HzAmperage AC and DCAmps DCMaximum amperage DCBasic accuracy, %Maximum resolution, AAmps ACMaximum amperage ACBasic accuracy, %Maximum resolution, ABand width, HzResistance Maximum resolution mMaximum resistance M

2000 4000 4000 4000

UD333

••

600 V0.50.1400

600 A 1.50.1 400

100200

UD334

••

•••

600 V 0.50.1

600 V1

0.11000

1000 A 1.50.1

1000 A 2

0.11000

100400

UD337

••

•••

750 V 1

0.01

750 V 1

0.011000

700 A2

0.01

700 A 2

0.011000

1004K

UD370

••

•••••

750 V 1

0.11000

750 A 1.50.1450

PRODUCTS CODE

598PAGE

598PAGE

598PAGE

598PAGE

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

594

DIAGNOSTIC EQUIPMENT

BOROSCOPES The borescope is an accessory that is used in visual inspections which we do not have a physical space through which we see, which forces us to use an instrument that has a small footprint to access through the holes, and in some cases even allow rotation. They have a light source that works with fiber optics, which ensures the correct lighting to inspect the entire area even when there is a rotation or the head of the borescope. They are used mainly by security personnel, electricians, electrical and electronics mechanics, precision mechanics, auto mechanics or aviation.

BOROSCOPE REC

BOROSCOPE BASIC

UBORVI

UBORSI

BOROSCOPEREC

BOROSCOPEBASIC

POWERSUPPLY

POWERSUPPLY

4AA batteriesDC 5V or 12V

4AA batteries

DIMENSIONS

DIMENSIONS

mm225X102X66

mm209x93.5x57.5

Video cable, USB cord, micro sd 2Gb

Video cable,3 nibs

ACCESSORIES

ACCESSORIES

(with batteries)

(with batteries)

gm750

gm750

lb.1.65

lb.1.65

DETAILEDSPECIFICATIONS 600PAGE

DETAILEDSPECIFICATIONS 600PAGE

Diameter of probe 5mm

Cable probe camera driver

Cable probe camera driver

Diameter of probe 5mm

Screen pixeles resolution 720 x 480

pixels

Screen pixeles resolution 320 x 240

pixels

Inspection snap and recording boroscope

Image zoom5X

Image zoom1.5X

Needs 4AA batteriesnot included

Needs 4AA batteriesincluded

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS ACCESSORIES

DIGITAL MULTIMETERS

BOROSCOPE

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

595

EQUIPMENT

DIAGNOSTIC

15

DIAGNOSTIC EQUIPMENT

DIGITAL MULTIMETERS Digital Multimeters perform standard electrical tests in DC and AC circuits–including frequency cycles, wave amplitude–and take digital readings of voltage, amperage and resistance of systems, components and conductors. They are simply better and easier to read.

They are designed to help service A/C, heating and cooling systems, appliances, computer equipment, and electrical equipment in general.

Backlight LCD screen allows easy data

reading.

Iconography makes it easier to properly

use the device.

Comes with a shock-absorbing cover for

protection, featuring a flip out stand.

Hand dial.

UD12BASICMODEL,COMPACTDESIGN

VOLTAGE

Volts DC600

DIMENSIONS (with case)

mm54 x 80 x 154

Volts AC600

Max OHMS200Ω

Resolution100 mΩ

RESISTANCE

(with case)

gm380

lb.0.83

DETAILEDSPECIFICATIONS 601PAGE

UD18COMPACTDESIGN

VOLTAGE

Volts DC750

DIMENSIONS (with case)

mm54 x 80 x 154

Volts AC750

Max OHMS200MΩ

Resolution100 mΩ

RESISTANCE

(with case)

gm425

lb.0.93

DETAILEDSPECIFICATIONS 601PAGE

Continuity tone.

UD12UD18

COMPACT DIGITAL MULTIMETERS

All digital multimeters include a set of test probes and alligator clamp ends.

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS ACCESSORIES

DIGITAL MULTIMETERSBOROSCOPE DIGITAL

MULTIMETERS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

596

DIAGNOSTIC EQUIPMENT

UD85TRUERMSAUTORANGING

VOLTAGE

Volts DC

1000

DIMENSIONS (with case)

mm40 x 85 x 190

VoltsAC750

AmpsDC10A

AMPS

(with case)

gm380

lb.0.83

AmpsAC10A

Max OHMS40MΩ

RESISTANCE

DETAILEDSPECIFICATIONS 602PAGE

UD77MANUALRANGE,GENERALUSE

VOLTAGE

Volts DC

1000

DIMENSIONS (with case)

mm54x80x154

VoltsAC750

AmpsDC10A

AMPS

(with case)

gm655

lb.1.44

AmpsAC10A

Max OHMS20MΩ

RESISTANCE

DETAILEDSPECIFICATIONS 602PAGE DETAILEDSPECIFICATIONS 603PAGE

UD112LATESTGENERATION

Volts DC

1000mm

40.5x92x172

VoltsAC

1000

AmpsDC10A

gm386

lb.0.85

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

DETAILEDSPECIFICATIONS 604PAGE

UD87TRUERMS,LATESTGENERATION

Volts DC

1000mm

40 x 85 x 190

VoltsAC750

AmpsDC10A

gm380

lb.0.83

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

DETAILEDSPECIFICATIONS 603PAGE

UD179TRUERMS,LATESTGENERATION

Volts DC

1000mm

40.5x92x172

VoltsAC

1000

AmpsDC10A

gm386

lb.0.85

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

Model UD87 comes with interface cable RS-232C.

Models UD179 and UD87 include a temperature sensor. Model UD85 includes only the adapter.

UD87 comes with software CD.

GENERAL USE MULTIMETERS

DIGITAL MULTIMETERS, LATEST GENERATION

UD77

UD112

UD179

UD87

UD85

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS ACCESSORIES

DIGITAL MULTIMETERSBOROSCOPE DIGITAL

MULTIMETERS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

597

EQUIPMENT

DIAGNOSTIC

15

DIAGNOSTIC EQUIPMENT

AUTOMOTIVE DIGITAL MULTIMETERS Automotive digital multimeters are very efficient devices used to diagnose most problems in today's sophisticated automotive electronic systems.

Their solid construction allows them to be used in the rough and high-paced environments of auto shops. Great for diagnosis on all makes, models and types of vehicles. You can view readings from RPM activity cycles, DC and AC volts, resistance, frequency, pulse duration, dwell and min-max endpoints in an easy-to-navigate system.

DETAILEDSPECIFICATIONS 604PAGE

UD84AUTOMOTIVE,COMPACT

Volts DC600

mm168 x 85 x 50

VoltsAC600

AmpsDC10A

gm466

lb.1.02

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

DETAILEDSPECIFICATIONS 605PAGE

UD86AUTOMOTIVE,GENERALUSE

Volts DC750

mm47 x 10 x 203

VoltsAC750

AmpsDC10A

gm610

lb.1.34

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

DETAILEDSPECIFICATIONS 605PAGE

UD88PROFESSIONAL,AUTOMOTIVE

Volts DC

1000mm

54x103x208

VoltsAC750

AmpsDC10A

gm655

lb.1.44

AmpsAC10A

Max OHMS40MΩ

VOLTAGE DIMENSIONS (with case)

AMPS

(with case)

RESISTANCE

UD88 includes a convenient plastic case for easy transport.

Automotive digital multimeters include a set of probes and alligator clamp ends.

RPM inductive pickup in all automotive digital multimeters.

Backlight LCD screen.

Comes with a shock-absorbing case that

protects it from rough handling. The case

features a flip out stand.

Guiding iconography

makes it easier to properly use

the device.

Dial

UD88

UD84

UD86

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS ACCESSORIES

DIGITAL MULTIMETERSBOROSCOPE AUTOMOTIVE

DIGITAL MULTIMETERS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

598

CLAMP-ON DIGITAL MULTIMETERS

UD333UD334

Digital automotive multimeters

include a set of test probes, alligator clamp ends and

case

Digital automotive multimeters

include a set of test probes, alligator clamp ends and

case

Hand selection dial

Backlight LCD screen

Iconography makes it easier to

properly use the device.

Trigger opens clamp

Designed to extend the ability to measure current in AC/DC and high power circuits, outputs and derivations in transformers, capacitors, rectifiers, transmission lines, substation conductors, etc., where a conventional device cannot be used. They also measure current, resistance, voltage, conductivity tests, power factor, AC frequency, among others without interrupting the connections and energy in the circuit. Thanks to their resistant build they are sufficiently strong to endure the exacting requirements in the transmission and generation of electricity.

Special clamp design

This model features an AC / DC selector.

UD334TRUERMS

DIMENSIONS

mm34 x 85 x 208

Max OHMS400Ω

RESISTANCE CLAMP OPENING

mm32

AMPS

AC1000A

DC1000A

VOLTAGE

VOLTSAC

600V

VOLTSDC

600V

DETAILEDSPECIFICATIONS 606PAGE

UD333GENERALUSE

DIMENSIONS

mm34 x 85 x 208

VOLTAGE

VoltsAC

600Vgm380

lb.0.83

AMPS

AmpsAC

600AMax OHMS

200Ω

RESISTANCE CLAMP OPENING

mm32

DETAILEDSPECIFICATIONS 606PAGE

GENERAL USE CLAMP-ON DIGITAL MULTIMETERS

UD337 UD370

UD337PROFESSIONALTRUERMSMULTIMETER

DIMENSIONS

mm43.9 x 97.5 x 245

Max OHMS4KΩ

RESISTANCE CLAMP OPENING

mm52

AMPS

AC700A

DC700A

VOLTAGE

VAC

750V

VDC

750V

DETAILEDSPECIFICATIONS 607PAGE

UD370TRUERMSMULTIMETER

DIMENSIONSRESISTANCE CLAMP OPENING

AMPS VOLTAGE

mm43.9 x 97.5 x 245

VoltsAC

750V

AmpsAC

750Amm52

Max OHMS4KΩ

DETAILEDSPECIFICATIONS 607PAGE

Backlight LCD screen

Iconography makes it easier to

properly use the device.

Trigger opens clamp

Hand protecting

bump

Special clamp design

CLAMP-ON DIGITAL MULTIMETERS

DIAGNOSTIC EQUIPMENT

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS ACCESSORIES

DIGITAL MULTIMETERSBOROSCOPE CLAMP-ON DIGITAL

MULTIMETERS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

599

EQUIPMENT

DIAGNOSTIC

15

INTERFACECABLERS-232C(1.5MT)

CDCOMMUNICATIONSSOFTWARE

UD50RS

Allows connection to a computer using port RS-232C to download and store information, and also program the multimeter.

DESCRIPTION

INTERFACE CABLE RS-232C (1.5 MT)

CODE DESCRIPTION

UD85SW Cd software for UD85 UD88SW Cd software for UD88

TESTPROBESAND ALLIGATORENDS

UD71TLAC

0.313“ (8 mm) max jaw opening.Straight ends with protecting cover.

DESCRIPTION

SET OF TEST PROBES AND SILICON ALLIGATOR CLAMP ENDS

MULTIMETER ACCESSORIES

INFRARED THERMOMETERDistance-to-spot ratio

mm

inch

34@250

[email protected]@20

3.1@40

48@50078@1000

S

D

As distance (D) from the object increases, the diameter of the area being measured (S) gets larger.

UD20Basic model obtains temperature readings.

UD60Max/Min/Average/∆T.Auto measurement.Audible tones.

UD80Max/Min/Average/∆T.Auto measurement.Audible tones.Memory stores data.

INFRAREDTHERMOMETERS

UD20UD60UD80

CODE 10-POINT MEMORY

n/a••

gm380380380

lb.0.830.830.83

Q1 ˚C (Q1 ˚F)Q1 ˚C (Q1 ˚F)

1 ˚C (1 ˚F)

RESOLUTION DISTANCE-SPOT RATIO

12:112:112:1

TEMPERATURE RANGE

˚C-32 ~ 535-32 ~ 535-50 ~ 999

˚F-25 ~ 999-25 ~ 999

-58 ~ 1830

Auto off helps conserve energy.

Uses:

• Electrical maintenance.• Automotive repairs and maintenance.• Air conditioners.• Manufacturing processes.• Any location requiring temperature monitoring.

Accurate readings for a

long time.

Laser view can be turned on

and off.

Turn on trigger

LCD Screen

Wide DS radius. Readings in °C

and °F.

UD71TLACUD50RSUD85SW

DIAGNOSTIC EQUIPMENT

INFRARED THERMOMETERS

CLAMP-ON DIGITAL MULTIMETERS

AUTOMOTIVE DIGITAL MULTIMETERS

DIGITAL MULTIMETERSBOROSCOPE

ACCESSORIESINFRARED

THERMOMETERS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

600

UBORVISPECIALSPECIFICATIONS UBORSISPECIALSPECIFICATIONS

UBORVI UBORSI

BOROSCOPE SPECIFICATIONS

CAMERA

Camera head size Ø 5.5mm

Viewable Distance 20mm to 70mm

Field of view angle 60° (diagonal)

Resolution 720 x 480 effective pixels

LED 4 white LED

Working Temperature -0° to 60°

WATER RESISTANCE

Camera head and cable (when properly assembled)

CAMERA

Head size of the camera 5.5mm

Field of View 46°(horizontal field anglel),

34°(vertical field angle)

58°(diagonal field angle)

Distance visible 40mm-Infinity

Light Source 6 White LED

Shell length of the camera 35mm

Working Temperature 0° a 60°

WATER RESISTANCE

Insert tube water resistantDISPLAY

Resolution 320X(RGB)X240

Screen Size 3.5-inch TFT LCD

Operating Temperature -0° to 60°C

VIDEO OUTPUT

PAL / NTSC

PHOTO RESOLUTION

720x480(D1) and 360x240(CIF) JPEG Format.

VIDEO RESOLUTION

720x480(D1) and 30fps@360x240(CIF) Motion JPEG Video Recording 30fps AVI Playback

MEMORY

SD Card Slot (Micro SD / Micro SDHC) up to 16GB

COMPUTER INTERFACE

USB 2.0

CONDUIT CABLE

Conduit Cable Length 1000mm (3’)

Outer Conduit Cable Size Ø 5.5mm

POWER SUPPLY

4 AA Batteries (not supplied) DC Input 5V or 12V (not supplied)

ESTIMATED BATTERY LIFE

3 - 4 hours

DIMENSION

Weight 750 g (including batteries – not supplied)

Length 225 mm

Width 102 mm

Height 66 mm

ACCESSORIES

Video Cable , 45° lens adapter, USB Cord, Micro SD 2GB.

DISPLAY

Resolution 320x240

Screen Size 2.4"

Operating Temperature -0° a 30°

POWER SUPPLY

4 Alkaline AA 1.5-volt batteries

ESTIMATED BATTERY LIFE

8 Hrs

DIMENSION

Weight 750g (including batteries supplied)

Length 209mm

Width 93.5mm

Height 57.5mm

ACCESSORIES

Video Cable , 3 nibs.

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

EQUIPMENT

DIAGNOSTIC

601

15

Continuity tone.

Low battery indicator.

Manual range selector for AC/DC voltage.

CE Certificate.

UD12SPECIALCHARACTERISTICS

FUNCTION

DC Voltage

AC Voltage(45Hz to 450Hz)RESISTANCECONTINUITY

RANGE

20V200V600V200V600V200Ω

RESOLUTION

10mV100mV

1V100mV

1V0.1Ω

ACCURACY

±1.5%

±1.5%

±1.5%3V open circuit test voltageThreshold: Approx. < 50

Digital Screen:

Reading Rate:

Input Impedance:

Storage Temperature:

Operating Temperature:

Altitude:

Relative Humidity:

Battery Type:

Battery Life:

Dimensions:

Weight:

Accessories:

31/2 digits 2000 counts with automatic polarity indicator.

2-3 readings per minute.

10M.

-10°C to 50°C (14°F to 122°F).

0°C to 40°C (32°F to 104°F).

2000 mt (6562 feet).

0% to 80% (0°C to 35°C).

0% to 70% (35°C to 45°C).

9V NEDA 1604 or IEC 6LR61.

200 hours typical (Alkaline).

Without case: 36 x 70 x 140 mm

With case: 54 x 80 x 154 mm

Without case: 220 gm

With case: 380 gm

Set of test probes and alligator clamps, 9V battery, protective cover and

manual.

UD12SPECIALSPECIFICATIONS

UD12 UD18

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

3 3/4 digits 4000 counts with automatic polarity indicator

41-segment graphic bars

Digital: 5 times per second

Analog: 10 times per second

-20°C to 60°C (-4°F to 140°F)

0°C to 40°C (32°F to 104°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

9V NEDA 1604 or IEC 6LR61

200 hours typical (Alkaline)

Without case: 36 x 70 x 140 mm

With case: 54 x 80 x 154 mm

Without case: 252 gm

With case: 425 gm

Set of test probes and alligator clamps, 9V battery, protective cover and manual.

UD18SPECIALSPECIFICATIONS

FUNCTION

DC Voltage

AC Voltage(50Hz to 450Hz)

RESISTANCE

CAPACITANCE

FREQUENCY

DIODE TEST

CONTINUITYLOGIC TEST

RANGE

400mV4V

40V400V750V

4V40V

400V750V400Ω4KΩ40KΩ400KΩ4MΩ20MΩ

1µF10µF

100µF1000µF

10 000µF20KHz

200KHz

RESOLUTION

0.1mV0.001V0.01V0.1V1V

0.001V0.01V0.1V1V

0.1Ω0.001KΩ

0.01Ω0.1KΩ

0.001MΩ0.01MΩ0.001µF0.01µF0.1µF1µF1µF1Hz

10Hz

ACCURACY

±0.9%

±1.9%

±0.9%

±1.5%

±1.7%

“Approximately <100Ω IN THE 400Ω RANGE”-9.9V to + 39.9V DC (up to 4000 KHz)

Overload protection:Open circuit voltage test:Full scale voltage:Short circuit current:

600V DC/AC MAXIMUM<3.5V DC1V DC< 1.5mA

Analog bar

Frequency measurement

Capacitance

Diode test

Low battery indicator

Manual range selection for AC/DC voltage

CE certificate

Manual or automatic range selection

Data retention

Continuity beep

Automatic polarity

UD18SPECIALCHARACTERISTICS

MULTIMETER SPECIFICATIONS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

602

UD77

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

3 1/2 digits 2000 counts with automatic polarity indicator

3 times per second

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C) - 0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

350 typical hours (Alkaline)

Without case: 40 x 85 x 190 mm

With case: 54 x 103 x 208 mm

Without case: 380 gm

With case: 655 gm

Set of test probes and alligator clamps, 9V battery, protective cover and manual

UD77SPECIALSPECIFICATIONS

Continuity tone

Fuse-protected 10 amp range

Diode test

Low battery indicator

Manual range selection

CE certificate

Data retention

Large LCD screen (68.5 x 32.7 mm)

Logic test function

Capacitance

Frequency

UD77SPECIALCHARACTERISTICS

FUNCTION

DC Voltage

AC Voltage(45Hz to 450Hz)

AMPS

AC AMPERAGE(45Hz to 450Hz)

RESISTANCE

DIODE TEST

CONTINUITY

RANGE

200mV2V20V200V1000V200mV

2V20V200V750V

200_A2mA20mA200mA

2A10A

200µA2mA20mA200mA

2A10A

200Ω2KΩ20KΩ200KΩ2MΩ20MΩ

RESOLUTION

100µV1mV10mV0.1V1V

100µV1mV10mV0.1V1V

0.1µA1µA10µA100µA1mA10mA0.1µA1µA10µA100µA1mA10mA0.1Ω1Ω10Ω

0.1KΩ1KΩ10KΩ

ACCURACY

±0.5%

±0.8%

±1.2%

±0.8%

±2.0%

±0.8%

±3.0%

±0.5%

±3.0%“OPEN CIRCUIT VOLTAGE TEST: <3V TEST CURRENT: 1mA”

“OPEN CIRCUIT VOLTAGE TEST: <1.2V THRESHOLD: APPROX. <150_”

MULTIMETER SPECIFICATIONS

UD85

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

4 1/2 digits 4000 counts with automatic polarity indicator

41-segment bar graphic

Digital: 4 times per second. Analog: 20 times per second.

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

With backlighting: 150 hrs. Without backlighting: 200 hrs. typical use (alkaline)

Without case: 40 x 85 x 190 mm - With case 54 x 103 x 208 mm

Without case: 380 gm - With case 655 gm

Set of test probes and alligator clamps, 9V battery, protective cover, manual, and temperature probe adapter.

UD85SPECIALSPECIFICATIONS

Automatic or manual range selectionBacklight screenAnalog barFrequencyRelative modeSet maximums and minimumsData entryFuse-protected 10 amp rangeCapacitanceTrue RMSDiode testTemperatureStandby indicator

GO/NO GO comparator and percent setting functionsLow battery indicatorData retentionLarge LCD screen (68.5 x 32.7 mm) RS-232C interfaceCE certificateContinuity beepAutomatic polarityTHD (Total Harmonic Distortion) measurement 50/60 HzSecurity shutter prevents incorrect connections

UD85SPECIALCHARACTERISTICS

“Voltage ± 2%Current ± 2%”

FUNCTION

DC VOLTAGE

“AC VOLTAGE (45Hz to 450Hz)

True RMS”

DC AMPERAGE

AC AMPERAGE (45Hz to 450Hz)

True RMS

RESISTANCE

CAPACITANCE

FREQUENCY

TEMPERATURE

DIODE TEST

CONTINUITY“THD (Total Har-monic Distortion)

measurement50/60 Hz ± 0.1 Hz”

RANGE

400mV4V40V400V1000V

4V40V400V750V400µA4000µA40mA400mA

4A10A

400µA4000µA40mA400mA

4A10A

400Ω4KΩ40KΩ400KΩ4MΩ40MΩ

1µF10µF100µF1000µF200Hz2KHz20KHz200KHz>200KHz

“ -40 °C to -10 °C (-40 °F to 14 °F)”“ -10 °C to 20 °C (14 °F to 68 °F)”“ 20 °C to 400 °C (68 °F to 752 °F)”

“ 400 °C to 1370 °C (752 °F to 2498 °F)”

RESOLUTION

0.1mV1V

10V0.1V1V

1mV10mV0.1V1V

0.1µA1µA

0.01mA0.1mA0.001A0.01A0.1µA1µA

0.01mA0.1mA0.001A0.01A0.1Ω1Ω10Ω

0.1KΩ1KΩ10KΩ

0.001µF0.01µF0.1µF1µF

0.01Hz0.1Hz1Hz

10Hz100Hz“0.1 °C

( 0.1 °F)”“0.1 °C

( 0.1 °F)”“0.1 °C

( 0.1 °F)”“1 °C

( 1 °F)”

ACCURACY

± 0.3%

± 0.75%± 6%

± 0.75%

± 0.5%

± 1.0%

± 1.0%

± 1.5%

± 0.5%

± 1.2%

± 1.7%

± 2.5%± 0.2%

± 0.05%

“± 3.0 °C (± 3.0 °F) “

“± 1.0 °C (± 1.0 °F) ““± 3.0 °C

(± 3.0 °F) ““OPEN CIRCUIT VOLTAGE TEST: 3V TEST CURRENT: 2.5mA”

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

EQUIPMENT

DIAGNOSTIC

603

15

UD112

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

4 digits 4000 counts with automatic polarity indicator

5 times per second

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

Without backlighting: 750 hrs. typical use (alkaline)

40.5 x 92 x 172 mm

386 gm

Set of test probes and alligator clamps, 9V battery and manual.

UD112SPECIALSPECIFICATIONS

Automatic or manual range

selection

Backlight screen

Frequency

Relative mode

Fuse-protected 10 amp range

Capacitance

Diode test

Duty cycle

Low battery indicator

Data retention

Large LCD screen

(68.5 x 32.7 mm)

CE certificate

Continuity beep

Automatic polarity

Molded case

UD112SPECIALCHARACTERISTICS

“OPEN CIRCUIT VOLTAGE TEST: <1.5V TEST CURRENT: 0.25mA”

FUNCTION

DC VOLTAGE

AC VOLTAGE (40Hz to 400Hz)

DC AMPERAGE

AC AMPERAGE (40Hz to 400Hz)

RESISTANCE

CAPACITANCE

FREQUENCY

DIODE TEST

CONTINUITY

RANGE

400mV4V

40V400V

1000V400mV

4V40V

400V1000V400µA

4000µA40mA

400mA4A

10A400µA

4000µA40mA

400mA4A

10A400Ω4KΩ40KΩ400KΩ4MΩ40MΩ40nF

400nF4µF

40µF100µF5Hz

50Hz500Hz5KHz

50KHz500KHz5MHz

10MHz4V

RESOLUTION

100µV1mV

10mV100mV

1V100µV1mV

10mV100mV

1V0.1µA1µA

10µA100µA1mA

10mA0.1µA1µA

10µA100µA1mA

10mA0.1Ω1Ω10Ω100Ω1KΩ10KΩ10pF

100pF1nF

10nF100nF

0.001Hz0.01Hz0.1Hz1Hz

10Hz100Hz1KHz

10KHz

ACCURACY

± 0.5%

± 0.75%

± 0.75%

± 1.0%

± 1.0%

± 1.5%

± 1.0%

± 1.5%

± 1.0%

± 1.5%

± 2.5%

± 0.05%

2.0%

“OPEN CIRCUIT VOLTAGE TEST: <1.3V THRESHOLD: APPROX. >10Ω < 60Ω”

MULTIMETER SPECIFICATIONS

UD179

True RMS

Temperature

Automatic or manual range

selection

Backlight screen

Frequency

Relative mode

Fuse-protected 10 amp range

Capacitance

Diode test

Duty cycle

Low battery indicator

Data retention

Large LCD screen ( 68.5 x 32.7 mm)

CE certificate

Continuity beep

Automatic polarity

Molded case

UD179SPECIALCHARACTERISTICS

“Voltage ± 2%Current ± 2%”

FUNCTION

DC VOLTAGE

AC VOLTAGE (40Hz to 400Hz)

True RMS

DC AMPERAGE

AC AMPERAGE (40Hz to 400Hz)

True RMS

RESISTANCE

CAPACITANCE

FREQUENCY

TEMPERATURE

DIODE TEST

CONTINUITYTHD (Total Harmonic Distortion) measure-

ment 50/60 Hz ± 0.1 Hz

RANGE

400mV4V

40V400V

1000V400mV

4V40V

400V1000V400µA

4000µA40mA

400mA4A

10A400µA

4000µA40mA

400mA4A

10A400Ω4KΩ

40KΩ400KΩ4MΩ40MΩ40nF

400nF4µF

40µF100µF5Hz

50Hz500Hz5KHz

50KHz500KHz5MHz

10MHz-40 °C to -10 °C (-40 °F to 14 °F)-10 °C to 400 °C (14 °F to 752 °F)

400 °C to 1300 °C (752 °F to 2372 °F)

RESOLUTION

100µV1mV

10mV100mV

1V100µV1mV

10mV100mV

1V0.1µA1µA

10µA100µA1mA

10mA0.1µA1µA

10µA100µA1mA

10mA0.1Ω1Ω10Ω100Ω1KΩ

10KΩ10pF

100pF1nF

10nF100nF

0.001Hz0.01Hz0.1Hz1Hz

10Hz100Hz1KHz

10KHz1 °C

( 1 °F)1 °C

(1 °F)1 °C

( 1 °F)

ACCURACY

± 0.5%

± 0.75%± 2.0%

± 0.75%

± 1.0%

± 1.0%

± 1.5%

± 1.0%

± 1.5%

± 1.0%

± 1.5%

± 2.5%

± 0.05%

3% ± 5 °C (3% ± 5 °F)1% ± 3 °C (1% ± 3 °F)

± 3% of reading

“OPEN CIRCUIT VOLTAGE TEST: 3V TEST CURRENT: 2.5mA”“OPEN CIRCUIT VOLTAGE TEST: 1.2V THRESHOLD: APPROX. <100Ω”

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

4 digits 4000 counts with automatic polarity indicator

5 times per second

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C) - 0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

Without backlighting: 750 hrs. typical use (alkaline)

40.5 x 92 x 172 mm

386 gm

Set of test probes and alligator clamps, 9V battery, manual and K-type thermo-

couple with banana plug.

UD179SPECIALSPECIFICATIONS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

604

UD87

Automatic or manual range selectionBacklight screenAnalog barFrequencyRelative modeSet maximums and minimumsData entryFuse-protected 10 amp rangeCapacitanceTrue RMSDiode testTemperatureStandby indicator

Low battery indicatorData retentionExtra large LCD screen (68.5 x 32.7 mm)RS-232C interfaceCE certificateContinuity beepAutomatic polarityButtons for functions and special characteristicsOn-screen selection buttonsSettings menu for customizingCase included

UD87SPECIALCHARACTERISTICS

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

3 4/5 digits 5000 counts with automatic polarity indicator

25-segment bar graphic

Digital: 4 times per second. Analog: 40 times per second

-20°C to 60°C (-4°F to 140°F)

0°C to 50°C (32°F to 122°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C) - 0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

Without backlighting: 200 hrs. typical use (alkaline)

With case: 168 x 85 x 50 mm - Without case: 155 x 76 x 40.5 mm

With case: 466 gm - Without case: 269 gm

Set of test probes and alligator clamps, 9V battery, software CD for UD87

windows version, RS232C interface cable, protective cover, alligator clamps,

manual and K-type thermocouple.

UD87SPECIALSPECIFICATIONS

FUNCTION

DC VOLTAGE

AC VOLTAGE(40Hz to 50KHz)

True RMS

DC AMPERAGE

AC AMPERAGE (40Hz to 10KHz)

True RMS

RESISTANCE

CAPACITANCE

FREQUENCY

TEMPERATURE

DIODE TEST

CONTINUITY

RANGE

50mV500mV

5V50V500V1000V500mV

5V50V500V1000V500_A5mA50mA500mA

5A10A

500µA5mA50mA500mA

5A10A50Ω500Ω5KΩ50KΩ500KΩ5MΩ50MΩ

5nF50nF500nF

5µF50µF500µF5000µF50Hz500Hz5KHz50KHz500KHz5MHz

“ -50 °C to 1300 °C

(-58 °F to 2372 °F)”

RESOLUTION

10µV100µV1mV10mV100mV

1V100µV1mV10mV100mV

1V100nA

1µA10µA100µA1mA10mA100nA

1µA10µA100µA1mA10mA0.01Ω0.1Ω1Ω10Ω100Ω1KΩ10KΩ1pF10pF100pF

1nF10nF100nF

1µF0.001Hz0.01Hz0.1Hz1Hz10Hz100Hz“0.1 °C

( 0.1 °F)”

ACCURACY

± 0.1%

± 5% to ±1.2%

± 0.8%

± 0.5%

± 5% to ±1.0%

± 0.8%± 0.5%

± 0.3%

± 0.5%± 1.0%

± 1.0%

± 2.0%± 3.0%

± 3.5%

± 0.01%

“± 3.0 °C (± 5.4 °F) "t

“OPEN CIRCUIT VOLTAGE TEST: 3VTEST CURRENT: 1mA”“OPEN CIRCUIT VOLTAGE TEST: <1.3VTHRESHOLD: APPROX. >10Ω < 70Ω”

MULTIMETER SPECIFICATIONS

UD84

Activity cycle (duty cycle) range

Pulse duration

Dwell direct reading

RPM measurement

Automatic or manual range

selection

Frequency

Fuse-protected 10 amp range

Temperature

Low battery indicator

Data retention

LCD Screen (52 x 22 mm)

CE certificate

Continuity beep

Automatic polarity

Protective cover

UD84SPECIALCHARACTERISTICS

FUNCTION

FREQUENCY (0.5 Hz to 2 KHz Pulse duration

0.1 S)

RPM% DUTY CYCLEDWELL

PULSE DURATION

DC VOLTAGE

DC AMPERAGE

RESISTANCE

TEMPERATURE

CONTINUITY

RANGE

199.99

1999.9

30-9000

400mV4V40V400V600V4A10A

400Ω4KΩ40KΩ400KΩ4MΩ40MΩ

-40 °C to 20 °C (-40 °F to 68 °F)20 °C to 400 °C (68 °F to 752 °F)

400 °C to 1300 °C (752 °F to 2372 °F)

RESOLUTION

0.01 Hz

0.1 Hz

1 RPM

0.1mV1mV

10mV0.1V1V

1mA10mA0.1Ω1Ω10Ω

0.1kΩ1KΩ10KΩ0.1 °C

( 0.1 °F)0.1 °C

( 0.1 °F)0.1 °C

( 0.1 °F)

ACCURACY

± 0.5%

±2 RPM

± 0.5%

± 1.2%

± 0.75%

± 1.5%± 3 °C

(± 5.4 °F)1% ± 2 °C

(1% ± 3.6 °F)±3% of reading

OPEN CIRCUIT VOLTAGE TEST: <1.2VTHRESHOLD: APPROX. <100Ω

RANGE (mS)

1999.9

5.00

RESOLUTION (mS)0.1

0.01

0-099.9% (30 RPM to 1999 RPM, Pulse duration > 0.1s)0.0-356.4° (30 RPM to 1999 RPM, Pulse duration > 0.1s)0.002-1999.9mS (30RPM to 1999 RPM, Pulse duration > 0.1s)

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

3 4/5 digits 4000 counts with automatic polarity indicator

Two 41-segment bar graphs

DIGITAL: Once per second in: RPM, frequency, duty cycle, Dwell interval, pulse

duration; 3 times per second on all other functions. ANALOG: 3 times per

second.

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

200 hrs. typical use (alkaline)

With case: 168 x 85 x 50 mm

Without case: 155 x 76 x 40.5 mm

With case: 466 gm

Withoout case: 269 gm

Set of test probes and alligator clamps, 9V battery, protective cover and manual.

K-type thermocouple with banana plug and RPM inductive pickup

UD84SPECIALSPECIFICATIONS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

EQUIPMENT

DIAGNOSTIC

605

15

UD86

Activity cycle (duty cycle) rangePulse durationDwell direct readingRPM measurementAutomatic or manual range selectionSet maximums and minimumsFrequencyFuse-protected 10 amp rangeAnalog barTemperature

Low battery indicatorTrue RMSData retentionLCD screen (62 x 26 mm)Diode testCE certificateContinuity beepAutomatic polarityProtective cover

UD86SPECIALCHARACTERISTICS

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Dimensions

Weight

Accessories

3 3/4 digits 4000 counts with automatic polarity indicator

Two 41-segment bar graphs

Digital: Once per second in: RPM, frequency, duty cycle, Dwell interval, pulse

duration; 4 times per second on all other functions. Analog: 20 times per

second.

-20°C to 60°C (-4°F to 140°F)

0°C to 40°C (32°F to 104°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

200 hrs. typical use (alkaline)

With case: 47 x 10 x 203 mm

Without case: 32 x 86 x 187 mm

With case: 610 gm

Without case: 399 gm

Set of test probes and alligator clamps, 9V battery, protective cover, case and

manual.

K-type thermocouple with banana plug and RPM inductive pickup

UD86SPECIALSPECIFICATIONS

FUNCTION

FREQUENCY (0.5 Hz to 200KHz)

RPM IPRPM IG% DUTY CYCLEDWELL

PULSE DURATION

DC VOLTAGE

AC VOLTAGE(45Hz to 1KHz)

True RMS

DC AMPERAGE

AC AMPERAGE (45Hz to 1KHz)

True RMS

RESISTANCE

TEMPERATURE

DIODE TEST

CONTINUITY

RANGE

199.99Hz1999.99Hz19.99KHz199.99KHz30-900060-12000

400mV4V40V400V750V

4V40V400V750V400µA4000µA40mA400mA

4A10A

400µA4000µA40mA400mA

4A10A

400Ω4KΩ40KΩ400KΩ4MΩ40MΩ

-40 °C to 1370 °C (-40 °F to 2498 °F)

RESOLUTION

0.01 Hz0.1 Hz

0.001 KHz0.01 KHz1 RPM

100_V1mV

10mV100mV

1V1mV

10mV0.1V1V

0.1µA1µA

0.01mA0.1mA0.001A0.01A0.1µA1µA

0.01mA0.1mA1mA0.01A0.1Ω1Ω10Ω

0.1kΩ1KΩ10KΩ1 °C

( 1 °F)

ACCURACY

± 0.5%

±2 RPM

± 0.3%

± 0.75%± 2.5%

± 1.0%

± 0.75%

± 1.0%

± 1.0%

± 1.5%

± 0.5%

± 1.0%± 3 °C

(± 5.4 °F)OPEN CIRCUIT VOLTAGE TEST: <1.5V TEST CURRENT: 2.5mA

0-99.9% (30 RPM to 19999 RPM, Pulse duration > 2_S)0-356.4° (30 RPM to 1999 RPM, Pulse duration > 2_S)0.002-1999.9mS (30 RPM to 19999 RPM, Pulse duration > 2_S)

OPEN CIRCUIT VOLTAGE TEST: <1.2V THRESH-OLD: APPROX. <100Ω

MULTIMETER SPECIFICATIONS

UD88

Activity cycle (duty cycle) rangePulse durationDwell direct readingRPM measurementAutomatic or manual range selectionSet maximums and minimumsData entryFrequencyAnalog barBacklight screenFuse-protected 10 amp rangeCapacitanceTrue RMS

TemperatureLow battery indicatorRS-232C communicationData retentionLarge LCD screen (67 x 32 mm)Relative modeDiode testCE certificateContinuity beepAutomatic polarityProtective coverPlastic case

UD88SPECIALCHARACTERISTICS

Digital ScreenAnalog ScreenReading Rate

Storage TemperatureOperating TemperatureAltitudeRelative HumidityBattery TypeBattery LifeDimensionsWeightAccessories

4 1/2 digits 4000 counts with automatic polarity indicator Two 41-segment bar graphic Digital: Once per second in: RPM, frequency, duty cycle, Dwell indicator, pulse duration; 4 times per second on all other functions. Analog: 20 times per second. -20°C to 60°C (-4°F to 140°F) 0°C to 45°C (32°F to 113°F) 2000 mt (6562 feet) 0% to 80% (0°C to 35°C) - 0% to 70% (35°C to 45°C) 9V NEDA 1604 or IEC 6LR61With backlighting: 150 hrs. Without backlighting: 200 hrs. typical use (alkaline) With case: 54 x 103 x 208 mm - Without case: 40 x 85 x 190 mm With case: 655 gm - Without case: 380 gm Set of test probes and alligator clamps, 9V battery, protective cover, plastic case, manual, K-type thermocouple with banana plug and RPM inductive pickup

UD88GENERALSPECIFICATIONS

FUNCTION

FREQUENCY (0.5 Hz to 200KHz)

RPM IPRPM IG% DUTY CYCLEDWELL

PULSE DURATION

DC VOLTAGE

AC VOLTAGE(45Hz to 1KHz)

True RMS

DC AMPERAGE

AC AMPERAGE (45Hz to 1KHz)

True RMS

RESISTANCE

CAPACITANCE

TEMPERATURE

DIODE TEST

CONTINUITY

RANGE

199.99Hz1999.99Hz19.99KHz199.99KHz30-900060-12000

400mV4V40V400V750V4V40V400V750V400µA4000µA40mA400mA

4A10A

400µA4000µA40mA400mA

4A10A

400Ω4KΩ40KΩ400KΩ4MΩ40MΩ

1µF10µF100µF1000µF

-40 °C to -10 °C (-40 °F to 14 °F)-10 °C to 20 °C(14 °F to 68 °F)20 °C to 400 °C(68 °F to 752 °F)

400 °C to 1370 °C (752 °F to 2498 °F)

RESOLUTION

0.01 Hz0.1 Hz

0.001 KHz0.01 KHz1 RPM

100_V1mV

10mV100mV

1V1mV

10mV0.1V1V

0.1µA1µA

0.01mA0.1mA0.001A0.01A0.1µA1µA

0.01mA0.1mA1mA0.01A0.1Ω1Ω10Ω

0.1kΩ1KΩ10KΩ

0.001µF0.01µF0.1µF1µF

0.1 °C ( 0.1 °F)

1 °C (1 °F)

ACCURACY

± 0.02%

± 0.05%

±2 RPM

± 0.3%

± 0.75%

± 2.5%

± 0.5%

± 1.0%

± 1.0%

± 0.5%

± 1.5%

± 1.7%

± 3 °C (± 3°F)

± 1.0%

± 3.0%

OPEN CIRCUIT VOLTAGE TEST: <3V TEST CURRENT: <2.5mA

0-99.9% (30 RPM to 19999 RPM, Pulse duration > 2_S)

Pulse duration > 2_S)

0.002-1999.9mS (30 RPM to 19999 RPM, Pulse duration > 2_S)

OPEN CIRCUIT VOLTAGE TEST: <1.2V THRESHOLD: APPROX. <100Ω

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

606

MULTIMETER SPECIFICATIONSUD333

Cable centering markings

Hand protecting bump

Overload indicator

Manual range

Frequency

Low battery indicator

Data retention

LCD screen (47 x 17 mm)

CE certificate

Continuity beep

Automatic polarity

SPECIALCHARACTERISTICSUD333

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Maximum conductor size

Dimensions

Weight

Accessories

3 1/2 digits 2000 counts with

automatic polarity indicator

3 times per second.

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

200 hrs. typical use (alkaline)

38 mm diameter

34 x 85 x 208 mm

380 gmSet of test probes and alligator clamps, 9V battery, vinyl case and manual.

UD333SPECIALSPECIFICATIONS

FUNCTION

AC AMPERAGE (45Hz to 400Hz)

AC VOLTAGE (45Hz to 400Hz)

RESISTANCEFREQUENCYCONTINUITY

RANGE

200A600A200V600V200Ω2KHz

RESOLUTION

0.1A1A

0.1V1V

0.1Ω1Hz

ACCURACY

± 1.5%

± 2.0%± 0.5%± 1.5%± 1.0%

OPEN CIRCUIT VOLTAGE TEST: <1.2V THRESHOLD: APPROX. < 15Ω

Cable centering markings

Hand protecting bump

Overload indicator

True RMS

Automatic or manual range

selection

Frequency

Low battery indicator

Data retention

Voltage and Amperage

Zero adjustment switch for DC

amperage

LCD screen (47 x 17 mm)

CE certificate

Continuity beep

Automatic polarity

Diode test

UD334SPECIALCHARACTERISTICS

FUNCTION

AC AMPERAGE (45Hz to 1KHz)

True RMSDC AMPERAGE

“AC VOLTAGE (50Hz to 450Hz)”

DC VOLTAGE

RESISTANCE

FREQUENCY

DIODE TEST

CONTINUITY

RANGE

400A1000A

400A1000A400V600V400V600V400Ω4KHz

40KHz400KHz4MHz

RESOLUTION

0.1A1A

0.1A1A

0.1V1V

0.1V1V

0.1Ω1Hz

10Hz100Hz1kHz

ACCURACY

± 2.0%± 2.5%

± 1.5%

± 1.0%± 1.2%± 0.5%± 0.8%± 1.5%

± 0.5%

± 1.0%OPEN CIRCUIT VOLTAGE TEST: <3.0V TEST

CURRENT: <1.0mAOPEN CIRCUIT VOLTAGE TEST: <1.2V

THRESHOLD: APPROX. <15Ω

UD334

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Maximum conductor size

Dimensions

Weight

Accessories

3 3/4 digits 4000 counts with

automatic polarity indicator

3 times per second.

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

200 hrs. typical use (alkaline)

38 mm diameter

34 x 85 x 208 mm

380 gm

Set of test probes and alligator

clamps, 9V battery, Vinyl case and

manual.

UD334GENERALSPECIFICATIONS

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329

607

EQUIPMENT

DIAGNOSTIC

15

MULTIMETER SPECIFICATIONS

Cable centering markings

Hand protecting bump

Overload indicator

True RMS

Automatic or manual range

selection

Frequency

Low battery indicator

Data retention

LCD screen (55 x 26 mm)

CE certificate

Continuity beep

Automatic polarity

Analog bar

Set maximums and minimums

UD337SPECIALCHARACTERISTICS

Digital Screen

Analog Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Conductor maximum size

Dimensions

Weight

Accessories

3 3/4 digits 4000 counts with

automatic polarity indicator

41-segment bar graphic

DIGITAL: 4 times per second.

ANALOG: 20 times per second.

-20°C to 60°C (-4°F to 140°F)

-10°C to 55°C 14°F to 131°F)

2000 mt (6562 feet)

0% to 80% (0°C to 35°C)

0% to 70% (35°C to 45°C)

9V NEDA 1604 or IEC 6LR61

80 hrs. typical use (alkaline)

38 mm diameter

34 x 85 x 208 mm

545 gm

Set of test probes and alligator

clamps, 9V battery, case with clip

and manual.

UD337GENERALSPECIFICATIONS

FUNCTION

AC AMPERAGE (45Hz to 1KHz)

True RMSDC AMPERAGE

“AC VOLTAGE (50Hz to 450Hz)”

DC VOLTAGE

RESISTANCE

FREQUENCY

DIODE TEST

CONTINUITY

RANGE

400A1000A

400A1000A400V600V400V600V400Ω4KHz

40KHz400KHz4MHz

RESOLUTION

0.1A1A

0.1A1A

0.1V1V

0.1V1V

0.1Ω1Hz10Hz100Hz1kHz

ACCURACY

± 2.0%± 2.5%

± 1.5%

± 1.0%± 1.2%± 0.5%± 0.8%± 1.5%

± 0.5%

± 1.0%OPEN CIRCUIT VOLTAGE TEST: <3.0V TEST

CURRENT: <1.0mAOPEN CIRCUIT VOLTAGE TEST: <1.2V

THRESHOLD: APPROX. <15Ω

UD337

Real power, apparent power

and reactive power

Power factor

Real power energy integrator

Apparent power energy

integrator

Reactive power energy

integrator

Cable centering markings

Hand protecting bump

Overload indicator

True RMS

Automatic or manual range

selection

Low battery indicator

Data retention

LCD screen (55 x 27 mm)

CE certificate

Automatic polarity

Set maximums and minimums

Digital Screen

Reading Rate

Storage Temperature

Operating Temperature

Altitude

Relative Humidity

Battery Type

Battery Life

Maximum conductor size

Dimensions

Weight

Accessories

4 digits for power and 6 digits

for energy

4 times per second.

-20°C to 60°C (-4°F to 140°F)

0°C to 45°C (32°F to 113°F)

2000 mt (6562 feet)

0% to 80% (0°C to 50°C)

9V NEDA 1604 or IEC 6LR61

200 hrs. typical use (alkaline)

51 mm diameter

43.9 x 97.5 x 245 mm

545 gm

Set of test probes and alligator

clamps, 9V battery, case with clip

and manual.

UD370SPECIALCHARACTERISTICS

UD370GENERALSPECIFICATIONS

FUNCTION

REAL POWER MEASUREMENT

APPARENT POWER

MEASUREMENTPOWER FACTOR

MEASUREMENT (COS Ø)

AC AMPERAGE (45Hz to 450Hz)

True RMSAC VOLTAGE

(45Hz to 450Hz)True RMS

RESISTANCE

REAL POWER ENERGY

INTEGRATORAPPARENT

POWER ENERGY

INTEGRATORREACTIVE

POWER ENERGY

INTEGRATOR

RANGE

400KW750KW400KW750KW

0.3 to 1

400A750A

40V400V

400Ω4KΩ

40000KWh75000KWh

40000KWh75000KWh

40000KWh75000KWh

RESOLUTION

0.1KW1KW

0.1KW1KW

0.001

0.1A1A

0.01V0.1V

0.1Ω1Ω

0.1KWh1KWh

0.1KWh1KWh

0.1KWh1KWh

ACCURACY

± 1.5%

± 1.5%

± 2.0%

± 1.5%

± 1.0%

± 1.0%

± 1.5%

± 1.5%

± 4.0%

UD370

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329 web: http://mdmetric.com email: [email protected] RFQ form: http://mdmetric.com/rfq.htm How to order Urrea Tools: R629-part number example: R629-5212M