A powerful, super-intelligent 5-digit modular panel meter with advanced softwa
features for monitoring, measurement, control, and communication applications in a 96x48 ca
DI-50E, DI-60E,DI-60AE TigerDigital Panel Meter
General Features
Description
TIGER FAMILY: More than 75 different Plug-in
I-Series Input Signal Conditioners are approved for
Texmate’s Tiger Family of meters.
See www.texmate.com for an up to date listing.
Module Compatibility
• Modular construction with interchangeable input and
output modules.
• Able to receive single and dual input signals from one of more
than 75 input signal conditioners.
• Optional output module that can support a relay module with up to
six relays; an analog output module with user selectable isolated
voltage (0-10 VDC) or isolated current (0-20 mA);and a serial out-
put module with either isolated RS-232, isolated RS-485, or non-
isolated TTL logic level serial output.
• Auto-sensing high or optional low voltage AC / DC power supply.
• Built-in 5 / 10 / 24 VDC sensor excitation voltage.
• Optional red or green, 7- or 15-segment, 0.56” high LEDs
• Easy to program using front panel buttons or PC software.
• Internal program safety lockout switch to prevent tampering.
• Provision for external LOCK, HOLD, and TEST switch.
• Six programmable setpoints with front panel annunciator LEDs.
• Smart digital filtering and input averaging.
• Optional NEMA-4 front cover.
• Seven-level display and annunciator brightness control.
• Can perform dual channel tasks.
• Can be customized for O.E.M. applications.
• Make your O.E.M.meter perform complex functions but appear
simple to use by hiding set-up codes, etc.
• Texmate developed PC software for meter programming (serial
output module required).
The Texmate Tiger is a super-intelligent digital panel meter with p
grammable logic and advanced digital signal processing capabiliti
Its innovative modular design creates a highly flexible meter able
process almost any input signal type from one of more than 75 s
gle and dual input signal conditioner types. With relay, analog, a
serial communications output options available on an output modu
the meter becomes a powerful instrument for monitoring, measu
ment, control, and communication applications.
An auto-sensing high or optional low voltage AC / DC power sup
circuit means the meter can be powered from almost any pow
supply source. User selectable 5, 10, or 24 VDC excitation voltag
are available to power the input module.
The meter uses smart digital filtering and input averaging. T
meter’s resident software is designed to allow maximum user fle
bility through logical menus. All programming takes place in t
main or setpoint programming modes.The meter has a wide ran
of built-in software features. For more details on software featu
see Specifications on Page 2.
8/6/2019 Di50-60e 5 Panel Meter
http://slidepdf.com/reader/full/di50-60e-5-panel-meter 2/5
The Meter Meter Center - Chandler, AZ (800) 230-6008 www.Metercenter.comPage 2
Input Configuration: ......More than 75 single and dual input signal
conditioners available covering almost
every input signal type.
Optional Output Module
Relay Module: ..............14 standard relay configuration options
available using a combination of 5 A / 240
VAC Form A, 10 A / 240 VAC Form C
relays and open collector outputs (max six
relays). See Ordering Information
Analog Output Module : ..Isolated 0 to 20 mA, or 0 to 10 VDC
(digitally calibrated):
Accuracy: 0.02% over full scale
Resolution:1/45000
Compliance: 10 V
Update Rate: 7 readings per second
Serial Output Module: ..Communication: Isolated ASCII, or ModBus,
or Profibus with direct printer interface
Isolated RS-232, or isolated RS-485, or
non-isolated TTL serial output:
Data: 7/8 bitsBaud: 300, 600, 1200, 2400, 4800, 9600,
19200, or 57.6 k.
Parity: Off, odd, or even
Bus Address: 1 to 255
Display Range:
DI-50E ............................–19999 to 32766, or –19990 to 99990 with
fixed LSD zero selected
DI-60E, DI-60AE............–32766 to 32766, or –199990 to 327660
with fixed LSD zero selected.Totalizer and
counter functions to 999999
Input Impedance:........Depends on input signal conditioner
selected (1 MΩ for DCV )
Display: ........................7 segment, 0.56” (14.2 mm) LEDs for
DI-50T and DI-60T. 14 segment, 0.56”
(14.2mm) for DI-60AT. Red standard, or
optional green LEDs.
Annunciators: ..............Six red LEDs on front panel; one annunci-
ator per setpoint
Power Requirements
Standard High Voltage: Between 85-265 VAC or 95-370 VDC
Optional Low Voltage: ....Between 9-32 VAC or 10-60 VDC
Excitation Voltage: ........User selectable 5 / 10 / 20 VDC
Setpoints:......................Setpoint 1 activates Relay 1
Setpoint 2 activates Relay 2
Setpoint 3 activates Relay 3
Setpoint 4 activates Relay 4
Setpoint 5 resets selected register or acti-
vates Relay 5
Setpoint 6 resets selected register or acti-
vates Relay 6
Programming Buttons
PROGRAM: ..................Move from one program step to the next
UP:......................................Increase the value of the displayed parameter
DOWN: ..........................Decrease the value of the displayed parameter
Overrange Indications ....
Underrange Indications..
Internal Resolution: ....16-bits
Conversion Mode: ......Dual slope; bipolar. Depends on Input
signal conditioner selected.
Accuracy:......................±0.05% of reading + 2 digit (typical)
Conversion Rate: ........Typically 10 samples per second for 50 Hz;
5 samples per second for 60 Hz
Temp. Coefficient: ......Typically 30 ppm/ °C
Mains Input Polarity: ..Auto
Decimal Point:..............Front panel, user programmable to five
positions
Warm Up Time: ............10 minutes
Operating Temp.: ........0-50 °C
Case Dimensions: ......3.78" W x 1.89" H x 4.84" D (96 x 48 x 117
mm)
Case Material: ..............Polycarbonate
Lens Cover: ..................NEMA-4, (optional)
Application Functions Include:
Linearization ..................32-point linearization is used to convertnon-linear curves to straight sections over
the length of the curve.
Totalizator ......................The totalizator calculates the total of a
process signal being metered by accumu-
lating an input process variable over time.
Counter Function ..........A multitude of counter applications are
supported.
Timer ..............................Timer functions are supported in either time-
up, time-down, or real-time clock modes.
Math Function ................The math function can calculate the sum,
difference, ratio, and product of two inputs.This, for example, can be used to produce
a tare reading during weighing operations.
Peak and Valley ............The meter can retain peak and valley
(min/max) information and recall this on
the front panel.
Remote Setpoint Input ..Remote setpoint input via channel 2.
Primary Input
Compensation ................Provides compensation to the primary input
channel (CH1) via channels 1, 2, 3, 4
General FeaturesSpecifications
8/6/2019 Di50-60e 5 Panel Meter
http://slidepdf.com/reader/full/di50-60e-5-panel-meter 3/5
The MeterCenter - Chandler, AZ (800) 230-6008 www.MeterCenter.com page
Front Panel Functions
Program Button The PROGRAM button is used to move from one program step tothe next.When pressed at the same time as the UP button, it initiatesthe main programming mode. When pressed at the same time asthe DOWN button, it initiates the setpoint programming mode.
Up Button
When in the operational display, pressing the UP button initiates theviewing setpoints 2, 4, 6, and peak readings routine.Once into theroutine, pressing the UP button moves through the steps of the routine.
When setting a displayed parameter during programming, the UPbutton is used to increase the value of the displayed parameter.
Down Button When in the operational display, pressing the DOWN button initiatesthe viewing setpoints 1, 3, 5, and valley readings routine. Onceinto the routine, pressing the DOWN button moves through thesteps of the routine.
When setting a displayed parameter during programming, the DOWNbutton is used to decrease the value of the displayed parameter.
Annunciator LEDs The annunciator LEDs may be programmed to indicate the alarm sta-tus.They are labeled from left to right: SP1, SP2, SP3, SP4, SP5, SP6.
TEXMATE
Prog.
SP1 SP3SP2 SP4 SP5 SP6
P
UP
Button
DOWN
ButtonPROGRAM
Button
Display with Faceplate and Bezel
LED Annunciators
for Setpoints 1-6
O N
1
2
PROGRAM
LOCKOUTSwitch
SETPOINT
LOCKOUTSwitch
Seven Segment
LED Display
Display PCB without Faceplate and Bezel
32 31 30 29 28 27 26 25 17 16
14 158 9 10 11
Input Module(See specific input module data
sheet for connection details)
1 2 3 4 5 6
2 3 2 2 2 1 2024 19
18
12
Relay Outputs
Serial Output
Analog Output
AC/DC PowerFunction Pins
Pin 18 for Dual
Analog output ONLY
TEST
Rear Panel
COMMONHOLDLOCK CAPTURE
General FeaturesControls and Indicators Continued Controls and Indicators
Seven Segment LED Displays The five, seven segment LED displays are used to display the meterinput signal readings. They also display the programming codesand settings during programming. The display is available in red,green, or super bright red LEDs.
Program Lockout Switch When the PROGRAM LOCKOUT switch is set to the OFF position,all programmable meter functions can be changed except for set-ting the setpoints.
When set to position 2, the PROGRAM LOCKOUT switch prevents anyprogramming changes being made to the meter functions except forsetting the setpoints. If programming is attempted, the meter displays'LOC'. Position 2 allows programming parameters to be viewed but notchanged. See the
Display PCB without Faceplate and Bezel diagram.
Setpoint Lockout Switch
When the SETPOINT LOCKOUT switch is set to the OFF positiothe setpoints can be programmed.
Once the setpoint values have been entered and the SETPOILOCKOUT switch set to position 1, the setpoints can be viewed but changed. All other programming functions, except setpoint control futions, can be carried out provided the PROGRAM LOCKOUT switchset to OFF. See the Display PCB without Faceplate and Bezel diagra
Error Message “Err”
Error messages usually occur during calibration procedures. Tthree most likely causes of an error message are:1) The full scale and zero signals were too similar.The high input (
scale) signal must be at least 1000 counts greater than the linput (zero) signal (positive and negative values are allowed).
2) The scaling requirement exceeded the capability of the me( – 19999 to +32766).
3) No input signal present, or incorrect connections.
Rear Panel FunctionsProgram Lockout Pin By connecting the LOCK pin (pin 8 on the main PCB) to the COMON pin (pin 11 on the main PCB), the set-up program is locked o
The programmed meter parameters and setpoints can be viewbut not changed when the meter is in the "locked out" mode.
Hold Reading Pin When the HOLD pin (pin 9) is connected to the COMMON pin (1the displayed reading is frozen. However, A/D conversions continand as soon as pin 9 is disconnected from pin 11 by the switch, tupdated reading is instantly displayed when released by a switcontact.The HOLD pin can also be used to reset the following:
• Reset of total while in the total display.
• Reset of peak while in the peak display.
• Reset of valley while in the valley display.
• Reset of tare, peak, and valley while in the tare function.
• If the relays are latched, they are also reset with the above topeak, valley, or tare setting.
Display Test and Reset Pin When the TEST pin (pin 10) is connected to the COMMON p(pin 11), all segments of the display light up and five eights afive decimal points (8.8.8.8.8.) are displayed for three secondThis detects any missing segments in the display. The micprocessor is also reset during this time, losing all RAM settinsuch as peak and valley, and any settings set up in Code 9.
Common Pin To activate the HOLD, TEST and RESET, or LOCK pins from trear of the meter, the respective pins have to be connected to tCOMMON pin (pin 11).
8/6/2019 Di50-60e 5 Panel Meter
http://slidepdf.com/reader/full/di50-60e-5-panel-meter 4/5
The Meter Center - Chandler, AZ (800) 230-6008 www.MeterCenter.com Page
Installation InstructionsSTEP A Prepare the Panel
1) Cut a hole in the panel to suit the panelcutout. See Case Dimensions for panel cutout
sizes.
STEP B Install the Meter
1) Remove both mounting clips from the meter.
2) Push the meter into the panel cutout from thefront of the panel.
3) Attach both mounting clips to the meter from
the rear of the panel and push them towardsthe front of the panel until the meter is firmly
held.
STEP C Connect the Cables
1) Connect all input and output signal cables to
the connector pins (See Connector Pinouts
for details).
1
2
3
WARNING
AC and DC power supply voltages
are hazardous. Make sure thepower supply is isolated before
connecting to the meter.
2) Connect the power cables to the connector
pins (See Connector Pinouts for details).
Case Dimensions
Installation
Panel adaptor plates are availableto retrofit most existing panel cutouts.
When extra panel
mounting tightness is required,
order the optional screw mount clip.
P/N.(OP-MTLCLIP)Mounts in panels
up to 2" thick .Various bezel colorsare available. Black is standard.
For additional strength, extra Mounting Slide Clipscan be ordered and doubled up one behind theother. (P/N: 75-DMTCLIPF)
TOP VIEW
87.6 mm(3.45")mosaicfitting
95.6 (3.7
96 mm(3.78")
91.6 mm(3.6")DIN
CutoutSpacer
To open rearcover, use a smallflat blade screwdriver. Press downlightly to releasecatch on top orbottom of case andleaver outwards.
96 mm(3.78")
48 mm(1.89")
41 mm(1.61")
4.0 mm(0.16") typical
FRONT VIEW
117 mm(4.61")
SIDE VIEW
5.7 mm(0.22")
PANEL CUTOUT
43.4 mm(1.73")
1/8 DIN (96x48) DIN Cutout spacers
Top Connector14.5 mm (0.57")
Bottom Connector11.43mm (0.45")
3.56mm (0.14")DIN Cutout Spacer 1.27mm (0.05")Connector Socket
Metal Surround Case: These dimensions are increasedby 1.27mm (0.05") when the metal surround case is installed.
45 mm(1.77")
Snug Fitting
Mosaic Fitting
92 mm(3.62")
Loose Fitting
91.6mm(3.6")
41mm(1.61")
8 places
8 places
3.0mm(0.125")
8 places
4.45mm(0.175")
43.4mm(1.71")
1/8 DIN Cutout spacers
87.6mm(3.45")
Texmate's 96x48mm case is particularly suitable formounting in mosaic panels or insulative panels up to 2"thick. They can also stack mount, 2 up in existing cutoutsfor 1/4 DIN (96x96mm) or 4 up in 1/2 DIN (96X192mm).
8/6/2019 Di50-60e 5 Panel Meter
http://slidepdf.com/reader/full/di50-60e-5-panel-meter 5/5
The Meter Center (800) 230-6008 www.MeterCenter.com
Ordering Information
BASE PART # DISPLAY POWER SUPPLY INPUT MODULE ANALOG OUTPUT SERIAL OUTPUT RELAY OUTPUT SPECIAL
OA____DI-60E
Add to the basic model number the order code suffix for each standard option required. The last suffix is to
indicate how many different special options and or accessories that you may require to be included with this product.
Ordering Example: DI-60T-DR-PS1-IA01-AIC-R1-OA2 plus CR-CHANGE and a OP-N4X/96X48, $225 + N/C + N/C + 35 + 50 + 30 + 5+ 20 = $365
BASIC MODEL NUMBER
DI-50E . . . 96x48mm, Tiger, 5 Digit, E Version . . . . . . . . . .$180DI-60AE . . 96x48mm, Tiger, 6 Digit, Alphanumeric, E Version .$275
DI-60E . . . 96x48mm, Tiger, 6 Digit, E Version . . . . . . . . . .$225
Standard Options for this Model Number
Order Code Suffix Description List
DISPLAY
DR . .Red LED, 0.56 inch high . . . . . . . . . . . . . . . . . . . .N/CDB . . . .Super–bright Red LED, 0.56 inch high . . . . . . . . . . . . . . . . . . .$25DG . . .Green LED, 0.56 inch high . . . . . . . . . . . . . . . . . . . . . . . . . . .$10
POWER SUPPLY
PS1 . .85 - 265VAC / 95 - 370VDC . . . . . . . . . . . . . . . . . . .N/CPS2 . . .18 - 48VAC / 10 - 72VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $35
INPUT MODULES (Partial List. See www.texmate.com)
Unless otherwise specified Texmate will ship all modules precalibrated with factorypreselected ranges and/or scalings as shown in BOLD type.
IA01 . . .AC-Volts Scaled RMS, 200/600V AC . . . . . . . . . . . . . . . . . . . . . . . . . . . $35IA02 . . .AC-Volts Scaled RMS, 200mV/2V /20V AC . . . . . . . . . . . . . . . . . . . . . . .$35IA03 . . .AC-mA Scaled RMS, 2/20 /200mA AC . . . . . . . . . . . . . . . . . . . . . . . . . . $35IA04 . . .AC-Amps Scaled RMS, 0-1 Amp AC (0-100.00) . . . . . . . . . . . . . . . . . $40IA05 . . .AC-Amps Scaled RMS, 0-5 Amp AC (0-100.00) . . . . . . . . . . . . . . . . . $40IA06 . . .AC-Volts True RMS, 200/600V AC . . . . . . . . . . . . . . . . . . . . . . . . . . . .$55IA07 . . .AC-Volts True RMS, 200mV/2V /20V AC . . . . . . . . . . . . . . . . . . . . . . . . . $55IA08 . . .AC-mA True RMS, 2/20 /200mA AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . $55IA09 . . .AC-Amps True RMS, 0-1 Amp AC (0-100.00) . . . . . . . . . . . . . . . . . . . $55IA10 . . .AC-Mi llivolt, Scaled RMS, 100mV AC . . . . . . . . . . . . . . . . . . . . . . . . . $55IA11 . . .AC-Amps True RMS, 0-5 Amp AC (0-100.00) . . . . . . . . . . . . . . . . . . . $55IA12 . . .AC-Mi llivolt, True RMS, 100mV AC . . . . . . . . . . . . . . . . . . . . . . . . . . . $55ID01 . . .DC-Volts, 2 /20/200V/Custom w/24V DC Exc . . . . . . . . . . . . . . . . . . . . .$25ID02 . . .DC-Mil l i vol t, 20/50/100 /200mV DC w/24V DC Exc . . . . . . . . . . . . . . . . . $35ID03 . . .DC-Mil l i amp, 2/20 /200mA DC w/24V DC Exc . . . . . . . . . . . . . . . . . . . . .$25ID04 . . .DC-Amps, 5A DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $50
ID05 . . .DC-Volts 2 /20/20 0/Custom V DC w/Offset and 24V Exc. . . . . . . . . . . . . .$45ID06 . . .DC-Volts 2 /20/20 0/Custom V DC w/Ext.Decimal Select . . . . . . . . . . . . . .$35ID07 . . .DC-Mil l i amp, 2/20 /200mA DC w/Offset and 24V Exc . . . . . . . . . . . . . . . . $35ID08 . . .DC-Volts, 2 /20/200/Custom V DC w/Ext.LIN Table Select . . . . . . . . . . . . $45ID09 . . .DC-Amps, 1A DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $50IDD1 . . .Dual DC Volts, 2V DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $65IDD2 . . .Dual DC-Mi llivolts, 50mV DC(100.00) . . . . . . . . . . . . . . . . . . . . . . . . $65IDD3 . . .Dual DC-Mi llivolts, 50mV DC(100.00) . . . . . . . . . . . . . . . . . . . . . . . . $65IDD4 . . .Dual Input, Volts/mill ivolts 2V/50mV DC(100.00) . . . . . . . . . . . . . . . . $65IDP1 . . .Dual Process Loop,4-20mA (0-100.00) . . . . . . . . . . . . . . . . . . . . . . . $65IDP2 . . .Dual Input,4-20mA (0-100.00)/3-wire RTD . . . . . . . . . . . . . . . . . . . . $65IDP3 . . .Dual Input,4-20mA(0-100.00) /K/R/S/T/ J Thermocouple . . . . . . . . . . . .$65IDR1 . . .Dual Resistance Input, 0.2/2 /20KΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . . $65IDS1 . . .Dual Strain Gage Input,4 wire 2mV/V . . . . . . . . . . . . . . . . . . . . . . . . . $125IDS2 . . .Dual Pressure Input,4 wire 2mV/V . . . . . . . . . . . . . . . . . . . . . . . . . . . $125IDT1 . . .Dual Thermocouple Input J /K/R/T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $75IDT2 . . .Dual RTD Input, 2/3-wire, 100Ω Pt . . . . . . . . . . . . . . . . . . . . . . . . . . . $65IF01 . . .Frequency/RPM, 5 ranges; .04Hz-320KHz, 24V exc. . . . . . . . . . . . . . . . . $45
IF02 . . .Line Frequency, 50-500VAC, 5 ranges; .04Hz-320kHz . . . . . . . . . . . . . . . $65IF03 . . .Frequency, 1-50VAC, 5-30VDC, 5 ranges; .04Hz-320kHz . . . . . . . . . . . . .$65IF04 . . .Frequency/RPM, 2mV/5V with Excitation . . . . . . . . . . . . . . . . . . . . . . . .$65IP01 . . .Process Loop, 4-20mA(0-100.00) . . . . . . . . . . . . . . . . . . . . . . . . . . . $35IP02 . . .Process Loop, 4-20mA(0-100.00) w/24VDC Exc . . . . . . . . . . . . . . . . . $45IP03 . . .Process Input, 1-5V DC(0-100.00) w Offset, 24V Exc . . . . . . . . . . . . . .$45IP06 . . .Process Loop, 4-20mA(0-100.00) w/24VDC Exc and Autocal . . . . . . . . $45IP07 . . .Universal Process 2V/5V/10V /20V/200V/2mA/20mA/Custom . . . . . . . . . . $30IP08 . . .Universal Process 2V/5V/10V /20V/200V/2mA/20mA/Custom w/Autocal . .$55IPT1 . . .Prototype Board for Custom Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . $15IR01 . . .Resistance, 2/3 /4-Wire, 200Ω /2KΩ /20KΩ . . . . . . . . . . . . . . . . . . . . . . $35IR02 . . .3 wire Potentiometer 1KΩ min (0-100.00) . . . . . . . . . . . . . . . . . . . . . $40IS01 . . .Strain Gage 5/10VDC Exc., 20/2mV/V, 4 /6-wire . . . . . . . . . . . . . . . . . .$55IS02 . . .Pressure 5/10VDC Exc., 20/2mV/V, 4 /6-wire . . . . . . . . . . . . . . . . . . . . . $55IS03 . . .Pressure 5/10VDC Exc., 20/2mV/V, 4 /6-wire w/Autocal . . . . . . . . . . . . .$65IS04 . . .Pressure Ext Exc., 20/2mV/ V, 4 /6–wire . . . . . . . . . . . . . . . . . . . . . . . . .$45IT01 . . .Thermocouple, J /K/R/S/T/B/N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$30
IT02 . . .RTD, 100Ω Pt. 2/3 /4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$35IT12 . . .RTD, 120Ω Nickel 2/3 /4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . $45IT13 . . .RTD, 10Ω Copper 2/3 /4-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$40IW01 . . .AC-Watts, 300V/1A AC, Single Phase 2-wire . . . . . . . . . . . . . . . . . . . . $65IW02 . . .AC-Watts, 300V/5A AC, Single Phase 2-wire . . . . . . . . . . . . . . . . . . . . $65IW03 . . .DC-Watts, 10V/50mV DC (0-100.00) . . . . . . . . . . . . . . . . . . . . . . . . . . $65
ANALOG OUTPUT
AIC . . .Isolated 16 Bit Current Output, 4-20mA . . . . . . . . . . . . . . . .$50AIV . . .Isolated 16 Bit Voltage Output, 0-10VDC . . . . . . . . . . . . . . .$50S2 . . .Isolated RS-232 (Requires Cable, See Options) . . . . . . . . . .$65S4 . . .Isolated RS-485 (Requires Cables, See Options) . . . . . . . . .$85S5 . . .Isolated ModBus, ASCII Code Compatible . . . . . . . . . . . . . .$95
RELAY OUTPUT
R1 . . .Single 5A Form A Relay . . . . . . . . . . . . . . . . . . . . . . . . . . .$30R2 . . .Dual 5A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .$60R3 . . .Three 5A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . .$90R4 . . .Four 5A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .$120R5 . . .Five 5 A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . .$150
R6 . . .Six 5 A Form A Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . .$180R11 . . .Single 10A Form C Relay . . . . . . . . . . . . . . . . . . . . . . . . . .$35R12 . . .Dual 10A Form C Relays . . . . . . . . . . . . . . . . . . . . . . . . . .$70R13 . . .Dual 10A Form C & One 5A Form A Relays . . . . . . . . . . . . . . $105R14 . . .Dual 10A Form C & Dual 5A Form A Relays . . . . . . . . . . . . .$140R15 . . .Single 10A Form C & Dual 5A Form A Relays . . . . . . . . . . . .$95R16 . . .Single 10A Form C & Single 5A Form A Relays . . . . . . . . . . .$65R17 . . .Single 10A Form C & Three 5A Form A Relays . . . . . . . . . . .$125
Special Options and Accessories
Part Number Description List
SPECIAL OPTIONS (Specify Inputs or Outputs & Req. Reading )
76-DI60EG/N4 . . . "Touch" Faceplate, Green, factory installed. NEMA4 .$876-DI60ER/N4 . . . "Touch" Faceplate, Red, factory installed. NEMA4 . . .$8OP-P256K/R–E . .256K Processor with RTC . . . . . . . . . . . . . . . . . . . . .$105OP-P256K–E . . . .256K Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . $60
OP-P32K/R–E . . .32K Processor with RTC . . . . . . . . . . . . . . . . . . . . . .$75OP-P32K–E . . . .32K Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$30CR-CHANGE . . . .Cal ibr ated Range Change to another Standard Range . .$5CS-I /5 0 . . . . . . .Custom scaling within standard/custom range - 5 digit . . . .$14CS-I /6 0 . . . . . . .Custom scaling within standard/custom range - 6 digit . . . .$16CSR-I/ 50 . . . . . .Custom selectable range installation or mod - 5 digit .$38CSR-I/ 60 . . . . . .Custom selectable range installation or mod - 6 digit .$41CSS- I/ 50 . . . . . .Custom special scaling beyond standard range - 5 digit . . . . .$50CSS-I/ 60 . . . . . . Custom special scaling beyond standard range - 6 digit . . . . $55COA-I/ Singl e . . .Custom output, Special scaling of single analog output . . . .$20COA-I/ Dual . . . . .Custom output, Special scaling of dual analog output .$35COR-I/ RELAY . . .Custom output, Relays installed non-standard . . . . . . .$20CCP-I /SETUP . . .Custom configuration, Programmable functions - Setup . . . .$20CCP- I/ INSTL . . . . Custom configuration, Programmable functions - Install . . . .$5CLT-I/ SETUP . . . .Custom Linearization Table - Setup . . . . . . . . . . . . . .$20CLT-I/ INSTL . . . .Custom Linearization Table - Installation . . . . . . . . . .$5CMP-I/SETUP . . .Custom Macro Program - Setup . . . . . . . . . . . . . . . . $40CMP-I/INSTL . . .Custom Macro Program - Installation . . . . . . . . . . . .$5
ACCESSORIES (Specify Serial # for Custom Artwork Installation)75-DBBZ9648F . . .Black Bezel for 96x48mm Case . . . . . . . . . . . . . . . .$275-DM TCLIPF . . . .Side Slide Brackets (2 pc) - extra set, extra strength .$293-PLUG2P-DP . . .Extra Screw Terminal Conn., 2 Pin Power Plug . . . . .$293-PLUG2P-DR . . .Extra Screw Terminal Conn., 2 Pin Plug . . . . . . . . . .$293-PLUG3P-DR . . .Extra Screw Terminal Conn., 3 Pin Plug . . . . . . . . . .$393-PLUG4P-DR . . .Extra Screw Terminal Conn., 4 Pin Plug . . . . . . . . . .$4CV-485/232 . . . . .RS485 to RS232 Converter . . . . . . . . . . . . . . . . . . .$75OM- CABLE232 . . .Cable, 6ft, for RS232: RJ6 phone plug to DB9 female plug . .$10OM- CABLE485 . . .Cable, 6ft, for RS485: RJ6 phone plug to DB9 female plug . .$10OP-M CLP96 X48 . .Screw Mounting Clips (2 pc) - to screw tighten slide brackets .$6OP-M TL96X48 . . .Metal Surround Case, includes screw mounting clips .$16OP- N4X/96X48 . . .96x48mm clear lockable front cover–NEMA 4X, splash proof . . $20
Many other options and accessories are available. See full price list for more details.
Prices subject to change without notice.