determination of xipamide metabolite in human urine by high-performance liquid...

1
RAPID COMMUNICATIONS IN MASS SPECTROMETRY Rapid Commun. Mass Spectrom. 2004; 18: 2780 Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/rcm.1696 Erratum Determination of Xipamide metabolite in human urine by high-performance liquid chromatography/diode-array detection, high-performance liquid chromatography/ electrospray ionization mass spectrometry and gas chromatography/mass spectrometry Yunje Kim*, Kyungjin Han and Ki-Jung Paeng Doping Control Center, Korea Institute of Science and Technology, P.O. Box 131, Cheongryang, Seoul, Korea 2 Department of Chemistry, College of Science, Yonsei University, Seoul, Korea Received 20 April 2004; Revised 12 August 2004; Accepted 13 August 2004 Rapid Commun. Mass Spectrom. 2004; 18: 2505–2512 Due to an omission, one of the authors was not included in the affiliations. These should read: Yunje Kim 1 *, Kyungjin Han 1 , Ki-Jung Paeng 2 and Won Lee 3 1 Doping Control Center, Korea Institute of Science and Technology, P.O. Box 131, Cheongryang, Seoul, Korea 2 Department of Chemistry, College of Science, Yonsei University, Seoul, Korea 3 Research Institute of Basic Science and Department of Chemistry, KyungHee University, Seoul, Korea Copyright # 2004 John Wiley & Sons, Ltd. RCM Letter to the Editor

Upload: yunje-kim

Post on 06-Jul-2016

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Determination of Xipamide metabolite in human urine by high-performance liquid chromatography/diode-array detection, high-performance liquid chromatography/electrospray ionization

RAPID COMMUNICATIONS IN MASS SPECTROMETRY

Rapid Commun. Mass Spectrom. 2004; 18: 2780

Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/rcm.1696

Erratum

Determination of Xipamide metabolite in human urine by

high-performance liquid chromatography/diode-array

detection, high-performance liquid chromatography/

electrospray ionization mass spectrometry and gas

chromatography/mass spectrometry

Yunje Kim*, Kyungjin Han and Ki-Jung PaengDoping Control Center, Korea Institute of Science and Technology, P.O. Box 131, Cheongryang, Seoul, Korea2Department of Chemistry, College of Science, Yonsei University, Seoul, Korea

Received 20 April 2004; Revised 12 August 2004; Accepted 13 August 2004

Rapid Commun. Mass Spectrom. 2004; 18: 2505–2512

Due to an omission, one of the authors was not included in the affiliations. These should read:

Yunje Kim1*, Kyungjin Han1, Ki-Jung Paeng2 and Won Lee3

1Doping Control Center, Korea Institute of Science and Technology, P.O. Box 131, Cheongryang, Seoul, Korea2Department of Chemistry, College of Science, Yonsei University, Seoul, Korea3Research Institute of Basic Science and Department of Chemistry, KyungHee University, Seoul, Korea

Copyright # 2004 John Wiley & Sons, Ltd.

RCM

Letter to the Editor