Designing for Resilient & Net Zero Buildings

Neil Bulger PE | Integral Group

Page 2: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

2

Newyorker, Aug 2015

How Comfortable Are We?

“70 to 72 deg F”Personal Thermostats

Plenty of Air Conditioning, 300 sf/ton

Page 3: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

3

Radiant Convective Exhalation

47.5% 27.5% 27%

We Love Radiant Comfort

KSH ArchitectsTimmons Design Engineers

Delta Products Headquarters

• EPIC radiant systems project ($3 million)

• Simplified tools for design and control• Surveys, energy, and cost data, Codes• Collaboration with Technical University of Denmark

Page 4: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

4

http://www.sciencedirect.com/science/article/pii/S1876610215020652

All tested (radiant) systems where able to provide 

acceptable thermal environment even when (sized) 

to 50% of the maximum cooling load.

Cooling load comparison: Air vs. Radiant (TABS)

TABS with nighttime pre-cooling reduced peak cooling load by more than 50% compared to air system in west perimeter zone of an office building

Page 5: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

5

We Love Ceiling Fans

Page 6: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

6

Building Design Tools for Fans

Anemometer three Katrina performing tests

line partitionL‐shape partition

side table

Page 7: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

7

Domenico Feo

Ahhm LLCClimabond

Radiant for All

Future Ready Buildings

Less Cooling = Same Comfort750 sf/ton radiant = 500 sf/ton air

Page 8: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

8

Future Ready Buildings

Less Cooling = Same Comfort750 sf/ton radiant = 500 sf/ton air

Ceiling Fans for All ($1/sf?)

Future Ready Buildings

Less Cooling = Same Comfort750 sf/ton radiant = 500 sf/ton air

Ceiling Fans for All ($1/sf?)BatteriesSolar SystemsDemand Side ManagementRESILIENCY

W/

Page 9: Designing for Resilient & Net Zero Buildings · 2016-10-19  · 10/19/2016 1 Designing for Resilient & Net Zero Buildings Neil ... Newyorker, Aug 2015 How Comfortable Are We? “70

10/19/2016

9

Designing for Resilient & Net Zero Buildings

Neil Bulger, PE | PrincipalINTEGRAL GROUP