Page 1: Design of Flat Plate (2)

IN THE NAME OF ALLAH, THE MOST BENEFICENT,

THE MOST MERCIFUL

Page 2: Design of Flat Plate (2)

DESIGN OF FLAT PLATE

Page 3: Design of Flat Plate (2)

DESIGN OF FLAT PLATE

A five storey building has a line plan as shown below.

The floor consist of reinforced concrete flat plate with no edge

beam and has a ceiling height of 10 ft. The building is

subjected to gravity loads only. The dead load consist of 2 ½”

F.F, ½” ceiling plaster, 10 psf for mechanical fixtures and 25

psf for partition load. The live load = 60 psf. The external wall

weighs 350 Ib/ft. f’c = 4 ksi and fy = 60 ksi. Design the end

panel Q of the floor system. Check the conditions of DDM.Q

Page 4: Design of Flat Plate (2)

S

W

N

E

16'

16'

16'

18' 18' 18'

P

RR S

Q

16“ x 12"

16“ x 16“ COL

16“ x 12" COL

LINE PLAN

Page 5: Design of Flat Plate (2)

SOLUTIONSlab Thickness Refer to table 9.5 (c) of ACI Code.

h = ln/30 = 200/30 = 6.66" say 7.0"ln= 18x12 – 16 = 200"

Check for Geometry and Loading Condition of DDMACI 13.6.1 Refers

Three or more spans is each direction Panels are rectangular and 18/16 = 1.125 <2.0 Successive span don't differ No column offset Loads are due to gravity only

wd= 7x12.5+30+6+10+25= 158.5 psfwl= 60 psf2wd > wl ok

No beam present

Page 6: Design of Flat Plate (2)

Check for Shear LOADS

wu = 1.4(158.5) + 1.7x60 = 324 psf

Assuming ¾" clear cover and # 4 bar being used.

d= 7- 0.75 - 0.5/2 = 6"

Interior Column Critical section for punching shear is at a

distance d/2 from face of support.

Vu = [18x16 – (22/12)2]x324

= 92220 Ib

bo = 22x4 = 88"

According to ACI 11.12.2.1, Vc is smallest of the following

16"

22"

22" 16"

Page 7: Design of Flat Plate (2)

16"

22"

22" 16’

18’

Assumed Loaded Area for Interior Column

16"

Page 8: Design of Flat Plate (2)

• Vc= (2+4/βc)x √fc' bod βc = 1.0

=(2+4/1.0) √4000x88x6 =200362 lb

• Vc = (αsd/bo+2)√fc'bod

=(40x6/88+2) √4000x88x6 =157860 Ib.

αs = 40 for interior column

• Vc = 4√fc' bod = 4x√4000x88x6 = 133574 Ib.

Vc is the lowest of above three values i.e. 133574

Ib.

ΦVc = 0.85x133574= 113538 Ib.

ΦVc > Vu Safe

Exterior Column

bo = 15x2 + 22 = 52"

22"

15"

Page 9: Design of Flat Plate (2)

15”

22”

18’

8.5’

Assumed loaded area for exterior column

Page 10: Design of Flat Plate (2)

Shear is caused by floor load and weight of exterior wall.

Vu= [18x (8+0.5) – 22x15/144] 324 +[(18-16/12) 350 x 1.4]

= 57000 Ib.

Vc is smallest of the following

Vc = (2+4/βc)√ fc‘ bod = (2+4/1.33)√4000x52x6 = 98678 Ib

βc= 16/12 = 1.33

Vc = (αsd/bo+2) √fc' bod αs = 30 for exterior column

=(30x6/52+2) √4000x52x6 =107770 lb

Vc =4 √fc’ bo d =4x√4000x52x6 = 78930 lb

ΦVc = 0.85x78930 = 67090 Ibs.

ΦVc > Vu Safe

Page 11: Design of Flat Plate (2)

Total Factored Static Moment in E-W Dir and its Distr

Equivalent Rigid Frame on Inner Column Line

Mo = wul2ln2 /8 = 0.324x16(16.67)2/8 = 180.07 kft

ln = 18 - 16/12 = 16.67 ft

D.F ACI 13.6.3.2

- ve moment = 0.65Mo= 117.05 k'

+ ve moment = 0.35Mo= 63.02 k'

Moment in Column Strip ACI 13.6.4

l2/l1 = 16/18= 0.89, αl2/l1 = 0

- ve moment in C.S = 75 %

+ ve moment in C.S = 60 %

0.65 0.35 0.65

Page 12: Design of Flat Plate (2)

S

W

N

E

18' 18' 18'

P

RR S

Q

16“ x 12“ COL

16“ x 16“ COL

16“ x 12" COL

LINE PLAN

16’

16'

16’

Page 13: Design of Flat Plate (2)

Distribution of Moment

Location Total C.S Moment (k') M.S.Moment (k')

E-W Dir 117.05 117.05x0.75 = 87.78 29.26

- ve moment

E-W Dir 63.02 63.02x0.6 = 37.81 25.21+ ve moment

Page 14: Design of Flat Plate (2)

Equivalent Rigid Frame on Outer Column Line

Mo= 0.324(8+0.5)x (16.67)2/8+ 0.35 (16.67)2/8 x 1.4 = 112.68 kftD.F. For interior span

- ve moment = 0.65Mo = 0.65x112.68 = 73.24 kft

+ ve moment = 0.35Mo = 0.35x112.68 = 39.44 kft Percentage moment in C.S.=Same as for inner column line.

Distribution of momentsLocation Total Moment C.S.(kft) M.S .(kft)E-W Dir 73.24 73.24x0.75= 54.93 18.31- ve momentE-W Dir 39.44 39.44x0.60 = 23.66 15.78+ ve moment

0.65 0.35 0.65

Page 15: Design of Flat Plate (2)

Total Factored Static Moment in N-S Dir and its Distr

Mo= wu l2 ln2/8 = 0.324x18(14.83)2/8 = 160.40 kft

ln = 16 - (6+8)/12 = 14.83 ftD.F. ACI 13.6.3.3

Ext –ve moment = 0.26Mo= 41.70 k'

+ve moment = 0.52Mo= 83.41 k'

Int –ve moment = 0.70Mo= 112.28 k’Percentage Moment in C.S. ACI 13.6.4

l2/l1 = 18/16, = 1.13

α l2/l1 = 0 βt = 0Ext –ve moment in C.S = 100 %

+ve moment in C.S = 60 % Int –ve moment in C.S = 75 %

0.26

0.52

0.70

Page 16: Design of Flat Plate (2)

S

W

N

E

18' 18' 18'

P

RR S

Q

16“ x 12"

16“ x 16"

16“ x 12" Col

LINE PLAN

16’

16'

16’

Page 17: Design of Flat Plate (2)

Distribution of Moments.

Location Total moment C.S kft MS kft

N-S Dir 41.7 41.7 0.0

Ext -ve

N-S Dir 83.41 0.6x83.41=50.05 33.36

+ ve moment

N-S Dir 112.28 0.75x112.28=84.2 28.07

Int -ve moment

Page 18: Design of Flat Plate (2)

Design of Slab Reinforcement Panel QStrip Loc Muk’ b ft Mu/ft

kft

d” ρ As

in2

No of

bars

Remarks

E-W Dir

2x1/2 C.S

-ve

+ve

87.78

37.81

8

8

10.97

4.72

6

6

0.006

0.00258

3.46

1.49

18

8

E-W Dir

2x1/2 M.S

-ve

+ve

29.26

25.21

8

8

3.66

3.15

6

6

0.00208

0.00208

1.2

1.2

7

7

Use ρmin

Use ρmin

E-W Dir

1/2 C.S

-ve

+ve

54.93

23.66

4.5

4.5

12.2

5.26

6

6

0.00669

0.00288

2.17

0.93

12

5 Use ρmin

E-W Dir

1/2 M.S

-ve

+ve

18.31

15.78

4

4

4.58

3.95

6

6

0.0025

0.00216

0.72

0.63

4

4

N-S Dir

2x1/2 C.S

Ext-ve

+ve

Int-ve

41.7

50.05

84.21

8

8

8

5.21

6.26

10.53

5.5

5.5

5.5

0.0034

0.00408

0.00686

1.8

2.15

3.62

10

11

19

N-S Dir

2x1/2 M.S

Ext-ve

+ve

Int-ve

0

33.36

28.07

10

10

10

0

3.34

2.81

5.5

5.5

5.5

0.00227

0.00227

0.00227

1.5

1.5

1.5

8/9

8/9

8/9

Use ρmin

Use ρmin

Use ρmin

Page 19: Design of Flat Plate (2)

Asmin = 0.0018 bxh = 0.0018x12x7 = 0.15 in2

ρmin in E-W direction = 0.15/(12x6) = 0.00208

ρmin in N-S direction = 0.15/(12x5.5)= 0.00227

Area of steel can be calculated from flexural formula.

Mu = ɸρbd2fy(1-.59ρfy/fc’)

Page 20: Design of Flat Plate (2)

C.S8' - 0”

M.S10' - 0”

C.S8' - 0”

C.S4' - 6”

M.S8' - 0”

C.S8' - 0”

REINFORCEMENT PLAN

12#4T

10#4T

8#4T

11#4B

18#4T

19#4T

12#4T

10#4T

8#4T

11#4B

18#4T

19#4T

5#4B9#4T

8#4B9#4B

8#4B

9#4T

Page 21: Design of Flat Plate (2)

DESIGN THE INTERIOR PANEL OF THE ABOVE FLOOR SYSTEM

Solution

1. Slab Thickness Same as for exterior panel i.e. 7"

3. Total Factored Static Moment in E-W Dir and its Distribution Same as for exterior panel on interior column line

4. Total Factored Static Moment in N-S Dir and its Distr

Mo = wul2ln2/8 = 0.324 x 18 (16-16/12)2/8 = 156.82 k’

0.65

0.35

0.65D.F

S

ACI Code 13.6.3.2

Page 22: Design of Flat Plate (2)

S

W

N

E

18' 18' 18'

P

RR S

Q

16“ x 12" Col

LINE PLAN

16’

16'

16’

Page 23: Design of Flat Plate (2)

- ve Moment = 0.65 Mo = 101.93 k'

+ve Moment = 0.35 Mo = 54.89 k'

Percentage Moment in C.S.

l2/l1 = 18/16 = 1.13 αl2 / l1 = 0

+ve moment in C.S = 60%

- ve moment in C.S = 75%

Distribution of Moment

Location Total Moment C.S moment M.S moment

N-S Dir 0.75x101.93=

-ve moment 101.93 76.45 25.48

N-S Dir 0.6x54.89=

+ve moment 54.89 32.93 21.96

Page 24: Design of Flat Plate (2)

5.Design of Slab Reinforcement - Panel

Strip Loc M kft b ft Mu/ft

k'

d

in

ρ As

in2

No of

#4 Bar

Remark

E-W Dir

2x1/2 C.S

-ve

+ve

87.78

37.81

8

8

10.97

4.72

6

6

0.006

0.0025

8

3.46

1.49

18

8

E-W Dir

2x1/2 M.S

-ve

+ve

29.26

25.21

8

8

3.66

3.15

6

6

0.0020

8

0.0020

8

1.2

1.2

7

7

ρmin

N-S Dir

2x1/2 C.S

- ve

+ve

76.45

32.93

8

8

9.56

4.12

5.5

5.5

0.0061

9

0.0026

7

3.27

1.41

17

8

N-S Dir

2x1/2 M.S

- ve

+ve

25.48

21.96

10

10

2.55

2.20

5.5

5.5

0.0022

7

0.0022

7

1.5

1.5

8/9

8/9

ρmin

S

Page 25: Design of Flat Plate (2)

Asmin =0.0018 bxh= 0.15 in2

ρmin in E-W direction = 0.15/(12x6) = 0.00208

ρmin in N-S direction =0.15/(12x5.5) = 0.00227

Area of steel is calculated using flexural formula.

Mu = ɸρbd2fy(1- 0.59ρfy/fc’)

For example for moment of 10.97 kft, As is calculated as fol

12x10.97 = 0.9 ρ 12 (6)2 60 (1- 0.59 ρ 60/4)

8.85ρ2 – ρ + Mu/1944 = 0

ρ = 0.0060

As = 0.006x8x12x6 = 3.46 in2

Page 26: Design of Flat Plate (2)

C.S8' - 0”

M.S10' - 0”

C.S8' - 0”

C.S8' - 0”

M.S8' - 0”

C.S8' - 0”

Reinforcement Plan

6 Sketch

18#4T

17#4T

7#4T

8#4B

18#4T

17#4T

8#4B

9#4T

7#4B

9#4B

8#4B

9#4T

18#4T

17#4T

7#4T

8#4B

18#4T

17#4T

Page 27: Design of Flat Plate (2)

6#4T

6#4T

C.S M.S C.S M.S C.S

8#4T

7#4B

C.S

M.S

C.S

M.S

C.S

10#4T

12#4T

7#4T

5#4B

10#4T

11#4T

8#4B

9#4T

10#4B

10#4B

12#4B

9#4T

8#4B

9#4B

12#4B

9#4T

12#4T

10#4T

8#4T

11#4B

19#4T

19#4T

7#4T

8#4B

19#4T

17#4T

5#4B

9#4T

8#4B

9#4B

8#4B

9#4T

7#4B

9#4B

8#4B

9#4T

12#4T

10#4T

8#4T

11#4B

18#4T

19#4T

7#4T

8#4B

18#4T

17#4T

P

R S

Q

Page 28: Design of Flat Plate (2)

ANY QUESTION ?

Page 29: Design of Flat Plate (2)

ThanksThanks