Founded in 1998, Jsm Micro Inc is located in Montreal Quebec.

JSM specialize in protocol conversion technologies and in design of innovative electronic circuits for the telecommunications industry.

JSM also design, manufacture and sell its own products for the following applications:

Alarms contacts opening / closure detection and management.Aged people residential complex emergency call systems.Visual nurse call systems for nursing homes, hospitals, and health care related facilities.Staff security systems for hospitals, psychiatric care units, court houses ...Zone paging systems for telephone systems.Protocol converters for pocket paging or wireless phone systems.Messaging systems (MSF) for cordless DECT phone systems.

Overview

Page 3: Design and manufacturing of communications/alarm electronic circuits

JSM Products

Page 4: Design and manufacturing of communications/alarm electronic circuits

WSX1

Overview

The WSX1 CPU unit is used in protocol converter applications or as a central control unit for applications involving IO32A & IN32B circuits. The CPU unit will work according to the appropriate application software. It is usefull with all JSM Micro products.

Features

16 bits microprocessor50 mips coprocessorWatchdog supervisorReal time clock, li-on cellFLASH 512kRAM 2 x 512KJSM buss9 VAC powered12 VDC power output5 serial ports RS-232 / RS-485Parallel bidirectional portLight grey cold rolled steel enclosureCage Clamp (no screw) connectors

Page 5: Design and manufacturing of communications/alarm electronic circuits

CSX5

CSX5: RISC type CPU module

CSX5 modules can be networked together and also with the WSX1 controller. Each module can execute a different task according to software used. Software are available for the following messaging functions : TAP input, MEP input and generic (configurable) serial input. Software is also available to network modules together. The networking software will offer a MEP or TAP serial output. The modules can also be hooked to the WSX1 controller and used for messaging (MSF) with Multitone, Kirk DECT and SpectraLink phone systems. 

50 mips micro controller driven4k program memory128k – 1meg RAM memory512k FLASH memoryRS232 port with RTS/CTSRS485 networking portConfiguration by RS232 serial portReset button & L.E.D. indicatorBrownout and watchdog resetOff-white painted steel enclosure9v ac or 12v dc supply

Page 6: Design and manufacturing of communications/alarm electronic circuits

CSX5-ENC : Pocsag paging encoder module

The CSX5-ENC module is used to network other CSX5 modules together, thus forming a paging system. The module can be configured for 512 or 1024 bps output, signal and inhibit polarity. Eight optoisolated inputs can transmit an alarm or restore message. Other CSX5 modules are added to network to provide protocols inputs: TAP, MEP, COMP or GENERIC to extract messages from serial RS232 data ports. 

CSX5-GEN : Generic serial input module

Networked CSX5-GEN modules are used to capture serial strings, (mainly formatted printer outputs), qualifies them, extract information from them and form a destination and a message using user supplied set of rules. This message can then be send to pagers or DECT phones. 

CSX5-TAP : Tap input module

Networked CSX5-TAP modules are used to add a TAP port to either a paging system or a DECT phone system. There is one TAP input port per networked module. The RS232 TAP port is configurable for baudrate, parity and handshaking. A timed manual entry mode is also available on the TAP port by pressing . User is prompted for a pager number then for a message. 

CSX5-MEP :  Mep input module

Networked CSX5-MEP modules are used to add a MEP port to either a paging system or a DECT phone system. There is one MEP input port per networked module. The RS232 MEP port is configurable for baud rate, parity and handshaking. A timed manual entry mode is also avaliable on the MEP port by pressing . User is prompted for a pager number then for a message.

Page 7: Design and manufacturing of communications/alarm electronic circuits

IN32B

IN32B : optically isolated AC/DC supervised inputs 5 to 30 volts

Monitors electrical signals or mechanical contacts such as lamps, relays contacts, switches, thermostats, alarms and others. The monitored inputs status is reported to a central controller via the network where an appropriate action is taken according to inputs stimuli and the controller’s software. For example, information can be stored, displayed on giant sings, sent to pocket pagers etc. Each input can also detect steady or flashing signals on the same pin. Supervised mode steady signals only. 

Features

• Micro controller driven• Active/Passive protocols• RS485 networked• Field programmable, no PC required.• Accept dry contacts, N.O. or N.C.• Accept voltages 5-30 volts AC/DC• Accept supervised contacts• Active supervision mode, 10 seconds• Optically isolated inputs• Light grey cold rolled steel enclosure• 7.5 to 12 volts DC powered• Cage Clamp (no screw) connectors

Page 8: Design and manufacturing of communications/alarm electronic circuits

RTU8

RTU8: Room Station Controller

Features

• Compact• Fully supervises room stations and detects troubles• Keeps operating locally in case of connection lost• Can be powered locally or through the data cable• Modules can be joined without external cables• LED indicator• All wires can be quickly disconnected• Addressable

• The RTU8 module is used to detect troubles and calls from room and bathroom stations hooked up. It also controls corridor lamps. The module is compact and is designed to be installed near the rooms to minimize costs and ease the installation. Only one data/power cable (cat5) is needed to daisy-chain connect RTU8 modules together. Each RTU is independant, thanks to his microcontrolers. Address programming is made easy using one single button. A heartbeat LED indicates correct operation.

Page 9: Design and manufacturing of communications/alarm electronic circuits

RTU8-BEXP and PL2014B-BEXP

Features• Compact • Fully supervise room stations and detects troubles• Keeps operating locally in case of connection lost• Can be powered locally or through the data cable• Modules can be joined without external cables• Many LED indicators (red and white)• All wires can be quickly disconnected• Adressable

OverviewUsefull with the RTU8, the RTU8-BEXP and PL2014B-BEXP are using three power distributors wich create an additional possibility of connections. Those units can detect troubles and calls from room and bathroom stations. Many red LEDs indicates if the data is available at each RJ45 connector. Each PL2014B-BEXP is independant and uses its own microcontrollers. Il also has a data repetitive chip and a white flashing Del who indicates if the data is going through the PL2014B (scrolling display).

Page 10: Design and manufacturing of communications/alarm electronic circuits

RTU8-DISPL

Overview The main function of this unit is to show messages and to generate audible alarms. It

is controlled directly by our CPU unit (WSX1). This device is a fundamental part in the RTU system, adding monitoring capabilities to your system. It is able to sense if there are problems in the date transmission and power levels. In the case of a power failure, the unit will generate an alarm. It verifies the reception of the date and if there are no new supervisory data in couple of minutes it will generate a communication error. In both cases, the user can deactivate the alarm and notify the problem to your team. It can be installed over the wall or over your desk. It is powered through a CAT5 cable.

Features

• Compact• Communicates directly with the WSX1• Alphanumeric display. 20 x 4 characters• Shows time and date, and a customize message in the idle state• Shows alerts and problems with audible alarms• LED indicator• Monitors power supply and communication• Configurable (adress, language, volume, mute..)• Back-up battery

Page 11: Design and manufacturing of communications/alarm electronic circuits

S FTWARE PR DUCTS

Page 12: Design and manufacturing of communications/alarm electronic circuits

JSM Report

Manage database files containing downloaded report information from WSX1

View data in a clear and flexible way Quickly sort data by simply clicking on

the appropriate column header Make quick searches to quickly find

something Launch advanced queries to look for

certain patterns for analysis and reporting purposes

Quickly generate print-ready reports for anormal situations, statistics, room call listing, etc.

Download report information from Jsm Micro inc. WSX1 units

Copy and export data to external programs such as Microsoft Excel

Act as a server in a network; multiple users can connect to the same database and query it

Auto-launch when Windows starts and periodically check for updated report information

Page 13: Design and manufacturing of communications/alarm electronic circuits

JSM Presence

Designed to monitor resident's presence : make sure every resident is safe

Works with push buttons : if residents do not press within a certain time frame, an alarm is reported

Quickly get an overview of residents' personal information and current status

Add custom details to residents' profiles such as phone number and remarks

View an history of the events that occured for each resident

Receive graphical alerts on-screen for alarms and intrusions

Page 14: Design and manufacturing of communications/alarm electronic circuits

JSM Presence

Works using infrared motion sensors : if a certain time period elapses, an alarm is reported

Gather presence data from multiple COM ports

Define absence periods to disable alarm reporting for a given time lapse if the resident plans to go away

Intrusions can be reported if motion is detected during an absence period

Transmit notifications to pagers and email addresses if alarms and intrusions are reported

Page 15: Design and manufacturing of communications/alarm electronic circuits

SS-Messenger

SS-Messenger allows you to built messages and send them

to pagers, scrolling displays and wireless phone. It is based

on a user defined set of rules applied to a captured text

string.

SS-Messenger can be adapted to any system that has a

serial port, whether a fire alarm system, intrusion or nurse

call.

The serial port can be output to a printer or pagers.

Page 16: Design and manufacturing of communications/alarm electronic circuits

WSX1 firmware

CID Messenger - Caller-ID call management software

Several kind of telephone emergency calling devices exist on the market today. Majority of them use analog lines and dial pre-programmed phone numbers to report previously recorded alarm messages to users. These units can dial

several times the same number and escalate to a second number until somebody answers the call and dial a code to reset the unit or hang-up (if

the unit can detect the disconnect signal) or until there is a timeout if nobody answers. The dialers are installed in homes, aged people apartment buildings, care facilities and even in hospitals. CID Messenger is a firmware who interpret and react to caller-id information.

• CTD3.x Alarm contacts management software for WSX1 CPU

The CTD3.x software is designed to supervise IN32B alarm contacts input modules and generate appropriate alarm messages depending on the input type (emergency, code blue, normal call, etc.) and location using powerful prefix and suffix features. The CTD3.x software can also report alarms that have been restored. When an event occurs, the software broadcasts messages to whole teams that can contain alphanumeric displays, pagers and wireless phones. The software has powerful scheduling capabilities. The CTD3.x software can detect supervision troubles and broadcast messages if some troubles arise. It will also accumulate calls that can be retrieved using Jsm Report.

Page 17: Design and manufacturing of communications/alarm electronic circuits

• RTU8 Messenger - Call Management Software

The firmware polls RTU8 controls and detects calls coming from room and bathroom stations. It can

generate alarms, build and dispatch alarm messages to teams containing displays, pagers, wireless

phones. Calls can be dispatched to different groups based on the time and the day of the week and

based on the nature of the call. The software is configurable using the powerful template-based

Jsm Config software. It will also accumulate calls that can be retrieved using the Jsm Report

reporting and statistics software. It can also route data to Jsm Presence to make sure residents are

safe in their appartment.

• SCPMessenger - Staff Call Pro Integration

The SCP Messenger software is used to detect calls from StaffCallPro systems and generate

alarms, build and dispatch alarm messages to displays, pagers, wireless phones. Alarms are

broadcasted to whole teams that can contain displays, pagers, Kirk or SpectraLink phones. The

SCP Messenger software also has important scheduling and filtering capabilities : calls can be

dispatched to different groups based on the time and the day of the week and based on the nature

of the call. It is configurable using the powerful template-based Jsm Config software. It will also

accumulate calls that can be retrieved using the Jsm Report reporting software to prepare reports

and statistics.

Page 18: Design and manufacturing of communications/alarm electronic circuits

Visual Call System Specialized in senior residences

Page 19: Design and manufacturing of communications/alarm electronic circuits

RTU-Messenger Direct connection with smoke and

mouvement detector (JSM Presence) Bathroom pull cord station Call bed station Fully supervised Corridor lam Reports/stats. Pagers Scrolling display

Page 20: Design and manufacturing of communications/alarm electronic circuits

System integration

Can integrate most nurse call systems (alarm / fire system with serial port)

-Austco-Télécor-Rauland-Équinoxe-Ect…

Pagers Scrolling display Phones Statistical and report software Flexible configuration

Page 21: Design and manufacturing of communications/alarm electronic circuits

Wiring diagram

Page 22: Design and manufacturing of communications/alarm electronic circuits

RTU8 &

RTU8-BEXP

• JSM Report• JSM Display• JSM Presence• JSM Config• Page Com• JSM WSX1 monitor

Page 23: Design and manufacturing of communications/alarm electronic circuits

PL2014B24&

PL2014B24-BEXP

Page 24: Design and manufacturing of communications/alarm electronic circuits

With JSM Micro...

• The health professional will be well equip to answer all patient’s needs.

You have products that are design and manufacturing in Quebec, Canada

Page 25: Design and manufacturing of communications/alarm electronic circuits

JSM Micro Inc.2711 Des Ormeaux,Montreal, Quebec

H1L 4X6

Tel: 514-655-5731Fax: 514-355-9616

Web: [email protected]

Comments?Questions?