descaling procedure b hw-serie (hot water system)

5
Original document by manufacturer © Copyright Bravilor Bonamat B.V. MAN Descale B HW-Serie (HW section) (01-2019 / A) 1 / 5 9. L 8. G 7. K M N L 6. M 5. M 4. K M N L 3. 2. 1. The descaling symbol flashes. An audible signal sounds and the level blocks flash. Press key ‘L’ to confirm. Press key ‘G’ to start the descaling program. Press key ‘M’. Press key ‘M’. Press key ‘M’. PIN code: Press 1x K, 3x N(↑↑↑), 1x M (↓) and 1x N (↑). Dissolve 100 grams of Renegite in 1 litre of hand-warm water (approx. 40 °C). Stir the descaling solution, so that the agent is solved well. Read the safety instructions. Descaling procedure B HW-serie (Hot water system)

Upload: others

Post on 12-Mar-2022

41 views

Category:

Documents


0 download

TRANSCRIPT

Original document by manufacturer © Copyright Bravilor Bonamat B.V.

MAN Descale B HW-Serie (HW section) (01-2019 / A) 1 / 5

9.

L

8.

G7.

K M NL

6.

M

5.

M

4.

K M NL

3.2.1.

The descaling symbol flashes. An audible signal sounds and the level

blocks flash.Press key ‘L’ to confirm.Press key ‘G’ to start the descaling program.

Press key ‘M’.Press key ‘M’.Press key ‘M’.

PIN code: Press 1x K, 3x N(↑↑↑), 1x M (↓) and 1x N (↑).

Dissolve 100 grams of Renegite in 1 litre of hand-warm water (approx. 40 °C).

Stir the descaling solution, so that the agent is solved well.

Read the safety instructions.

Descaling procedure B HW-serie (Hot water system)

MAN Descale B HW-Serie (HW section).indd 1 16-1-2019 14:20:09

Original document by manufacturer © Copyright Bravilor Bonamat B.V.

MAN Descale B HW-Serie (HW section) (01-2019 / A) 2 / 5

18.

80º C

17.

L

16.

15.14.13.

L

12.

ca. 1 cm

11.10.

Pour hot water into the hot water boiler to just above the lime edge (this speeds up the

descaling process).The hot water boiler is filled with water and

warmed up. This takes some time.If the Renegite solution has been added,

press key ‘L’.

Place the funnel in the filling opening. Carefully pour the Renegite solution through

the funnel.Remove the plug from the filling opening for

the Renegite solution.The machine is ready to add descaling

solution.

The hot water boiler is empty. Press key ‘L’. (Close the tap!)

Pull the overflow pipe up by the short hose to fully drain the boiler.

(Tap open!).Empty the hot water boiler through the tap.

MAN Descale B HW-Serie (HW section).indd 2 16-1-2019 14:20:11

Original document by manufacturer © Copyright Bravilor Bonamat B.V.

MAN Descale B HW-Serie (HW section) (01-2019 / A) 3 / 5

27.26.25.

24.

80º C

L

23.

ca. 1 cm

22.

21.20.19.

Empty the hot water boiler through the tap.The hot water boiler is full.The hot water boiler is filled with water and warmed up. This takes some time.

Pour hot water into the hot water boiler to just above the lime edge (this speeds up the

descaling process).The hot water boiler is empty. Press key ‘L’. (Close the tap!)

Pull the overflow pipe up by the short hose to fully drain the boiler.

(Tap open!).

Empty the hot water boiler through the tap.The hot water boiler is full.Wait for 5 minutes for the Renegite to work.

MAN Descale B HW-Serie (HW section).indd 3 16-1-2019 14:20:12

Original document by manufacturer © Copyright Bravilor Bonamat B.V.

MAN Descale B HW-Serie (HW section) (01-2019 / A) 4 / 5

36.

80º C

L

35.

ca. 1 cm

34.

33.32.31.

30.

80º C

L

29.

ca. 1 cm

28.

Pour hot water into the hot water boiler to just above the lime edge (this speeds up the

descaling process).The hot water boiler is empty. Press key ‘L’. (Close the tap!)

Pull the overflow pipe up by the short hose to fully drain the boiler.

(Tap open!).

Empty the hot water boiler through the tap.The hot water boiler is full.The hot water boiler is filled with water and warmed up. This takes some time.

Pour hot water into the hot water boiler to just above the lime edge (this speeds up the

descaling process).The hot water boiler is empty. Press key ‘L’. (Close the tap!)

Pull the overflow pipe up by the short hose to fully drain the boiler.

(Tap open!).

MAN Descale B HW-Serie (HW section).indd 4 16-1-2019 14:20:13

Original document by manufacturer © Copyright Bravilor Bonamat B.V.

MAN Descale B HW-Serie (HW section) (01-2019 / A) 5 / 5

44.43.

42.

L

41.

ca. 1 cm

40.

39.38.37.

Note: Reference model B5 L/R

The descaling program has been closed. The display shows the user menu.

The counter reading is automatically reset to zero.

The display shows the counter reading.The hot water boiler is empty. Press key ‘L’. (Close the tap!)

Pull the overflow pipe up by the short hose to fully drain the boiler.

(Tap open!).

Empty the hot water boiler through the tap.The hot water boiler is full.The hot water boiler is filled with water and warmed up. This takes some time.

MAN Descale B HW-Serie (HW section).indd 5 16-1-2019 14:20:14