dental instrumentation - brasseler usa |...

8
To order call 800.841.4522 or fax 888.610.1937. In Canada call 800.363.3838 or fax 866.330.4454. Visit our website at BrasselerUSA.com Restorative Endodontics SO SOPHISTICATED ITS SIMPLE. EndoSequence Precision Endodontic System By Your Side in Dentistry DENTAL INSTRUMENTATION

Upload: doque

Post on 06-Feb-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

To order call 800.841.4522 or fax 888.610.1937.In Canada call 800.363.3838 or fax 866.330.4454.Visit our website at BrasselerUSA.com

Restorat ive Endodont ics™

SO SOPHISTICATED ITS SIMPLE.™

EndoSequencePrecision Endodontic System ™

By Your Sidein Dentistry

DENTAL INSTRUMENTATION

* Based on Brasseler’s internal sales and available data from all major US distributors.** Recipricating File Debris Extrusion: Apically Extruded Debris with Reciprocating Single-File and Full-Sequence Rotary Instrumentation Systems. JOE, Vol 8, Issue 6, June 2012, 850-852. *** Electropolishing: Anderson M, Price J, Parashos P. Fracture Resistance of Electropoloished Rotary Nickel-Titanium Endodontic Instruments. Journal of Endodontics, 2007; 33, 1212-1216. BonaccorsoA, Trip TR et al. Pitting Corrosion Resistance of Nickel-Titanium Rotary Instruments with Different Surface Treatments in Seventeen Percent Ethylenediaminetetraacetic Acid and SOdum Chloride Solutions. JOE 2008; 34: 208-211.Kobayashi C, Suda H. Durability of Nickel-Titanium Files in Curved Canals. JOE 2004; 30: Abstract 284.

SAFETY

RESISTANCE TO CYCLIC & TORSIONAL FATIGUE

Patented Alternating Contact Point™ design • File remains centered in the canal as the cutting edges engage with the den-

tinal wall at opposing intervals.

When selecting an endodontic shaping instrument several key performance factors must be considered. Brasseler believes that EndoSequenceisthemostpopularfileinNorthAmerica*becauseitexhibitsthebestcombinationofthefollowingdesirablecharacteristics:

Patented Precision Safety Tip • Non-cutting at tip but fully active at D1. • Reducesthechancesofperfingorledging.

Proprietary Electopolished Finish: • Manysurfaceorheatannealingtreatmentsimproveafilesresistancetocyclicfatiguebutdrasticallyreducethefilesresis-

tancetotorsionalstress.Whatgoodisafilethatperformswellinacyclicfatiguetestifitisdullandunwindswithoutwarn-ing (a major “length control” concern)?

• BrasselerfilesaretheonlyfilesinNorthAmericathatareelectropolished.ThisproprietarysurfacetreatmenthasbeenproventimeaftertimetoimprovetheEndoSequencefile’sresistancetocyclicandtorsionalfatigue.***

Scientifically Tested. Clinically Proven.

Twisted File® Non-Electropolished

Vortex® Non-Electropolished

Triangular cross section, sharp cutting edges and a large chip space. • Allowsforefficientdebrisremoval.

• File is never fully engaged with all sides of the canal wall so debris is carried coro-nally in a wave-like fashion (compare to reciprocating systems which push debris apically).**

DEBRISREMOVAL/CUTTINGEFFICIENCY

WaveOne® Non-Electropolished

Endosequence® Electropolished

Rotation to Fracture for Electropolished and Nonelectropolished Instruments

1400

1200

1000

800

600

400

200

045 degree angle 90 degree angle

Electropolished

Non-Electropolished

* A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments. Plotino G et al, Journal of Endodontics. Vol 35, Number 11, November 2009** Complete source of information available upon request.

Clinical Evaluation of Endo Cutting Instruments

Exce

llent

Ran

king

s

40

35

30

25

20

15

10

5

0%

33

23 24 23

9

EndoSequence® ProTaper® K3® ProFile®

Series 29®Liberator®

23

LightSpeed®

20

V-Taper™

A recent study review in the Journal of Endodontics concluded that all known benchtop test protocols fall short of evaluating all ofthekeyperformancecharacteristicsforendoshapinginstruments*.Notestprotocolpredictablyevaluatesallofthefollowingcharacteristics: • Cuttingefficiency(removalofdebrisawayfromtheapex) • Safety(non-perfing,non-ledgingandnon-transporting) • Resistancetocyclicfatigue(fileseparation) • Resistancetotorsionalstress(fileseparationanddeformation/unwinding/lengthening)

ThefollowingclinicalevaluationprovidesthestrongestevidencethattheEndoSequencefileprovidesthebestcombinationofallkey performance characteristics:

Collectinginputfrom472practicingdentists,90%ofthosewhoevaluatedtheEndoSequencefilerankeditsoverallperformanceas“excellent”, “very good” or “good”. Of the 8 brands evaluated, EndoSequence received 38% more “excellent” votes than the next closestcompetitor!**

I have used EndoSequence for years and I can say with confidence that they cut predictably and ef-ficiently. In my hands there is no other option.

– Dr. Lynne Brock DDS, CAGS, FACDEndodontist

“As a specialist I try new files as they come out so I stay abreast of the changing technology. To date I have not evaluated a file that can compete with EndoSe-quence in terms of exhibiting the best combination of cutting efficiency, flexibility and safety.

– Dr. Richard Herman, DDS Endodontist, Diplomat of the American Board of Endodontics

“ “

I would recommend EndoSequence to anyone looking to improve the quality and efficiency of their endodon-tic therapy.

–Dr.AlexFleurry,DDS,MSEndodontist

“ “

Scientifically Tested. Clinically Proven.

The EndoSequence system has drastically improved the efficiency of my practice. The files cut smoothly and the obturation and post system match perfectly.

– Dr. Wayne Pulver, DDS Dip Endo

EndoSequence® is the Only Endodontic System to be Fully Synchronized from Instrumentation through Obturation and Post Placement!

The Patented EndoSequence® File Design

EndoSequence Philosophy: • Therestorationofanendodonticallytreatedtoothbeginsattheapex. • Thecleaningandshapinginstrumentsshouldpreserve,tothegreatestextentpossible,thestructuralintegrityofthetooth. • Theobturationmaterialsshouldactasaconduit,notaninhibitor,toasuccessfullongtermrestoration. • Whenapostisnecessary,itshouldnotputunduestressontheroot.Itshouldhaveasimilarmodulusofelasticitytothatof

dentin and it should match the shape created by the last instrument used to shape the canal. • Thesystemshouldbeasefficientaspossiblebutthelongtermprognosisofthetoothtrumpssimplicity.

CountlesscompetitorshavetriedcircumventingourpatentsinthehopeofrivalingthecuttingefficiencyandsafetyoftheEndoSe-quencefile.Theirefforts,whileflattering,alwaysfallshort.EndoSequenceistheonlyfileintheworldthatcontainsallofthefollowingfeatures:

Typical Com-petitve File

3 pointengagement

2 pointengagement

1 pointengagement

Noengagement

Precision Tip•Non-activeat

the tip, fully active precisely at 1 mm

Electropolished Surface•Eliminatessurfaceimperfectionsthatweakenotherfiles

•Increasesfilesharpness

Patented ACP(Alternating Contact Point™) Design•Non-landed,reduced-dragdesign•Centersfilewithincanalwithoutradiallands•Preventsself-threading“screwin”tocanal•Enhancesdebrisremoval•Maximizescuttingefficiency

No Radial Lands•Flexibilityismaximized•Torqueisminimized•Reducedcrosssectionthickness•Sharpcuttingedge

CANAL & PROCEDUREPACKSIZE

AvailablewithCalibrationMarkings•Visibleonradiographs

EndoSequenceFile

LARGE

MEDIUM

SMALL

2013 READERS’CHOICE AWARD

R

R

R

R

R

R

R

R

R

R

Expeditor™ File & Procedure Packs•Expeditor™gaugescanalsizebasedondepthofinitialengagement.•Procedurepacksminimizeinventorycostsandexpediteprocedure.

TAKEThEENDOSEqUENCEChALLENGE:COMPAREThEENDOSEqUENCEFILETOyOURCURRENTFILE, ANDIFyOUDON’TPREFERENDOSEqUENCE,wEwILLGLADLyPROVIDEyOUwIThAFULLREFUND.

Large

Small

Medium

The “State-of-the-Art” in Endodontic Obturation Has Changed!

Unlikeconventionalbase/catalystsealers,BCSealerispremixedandutilizesthemoisturenaturallypres-ent in the dentinal tubules to initiate its setting reaction. This highly radiopaque and hydrophilic sealer forms hydroxyapatite upon setting and chemically bonds to both dentin and to our bioceramic points (EndoSequence® BC Points™). BC Sealer is anti-bacterial due to its highly alkaline pH and unliketraditionalsealers,BCSealerexhibitsabsolutelyzeroshrinkage!

A recent study concluded that EndoSequence BC Sealer, when used in conjunction with our biocermic points, actually strengthens the root to a fracture resistance comparable to that of teeth that have not undergone root canal therapy!

Finally a complete system that incorporates the restor-ative goals and long term prognosis of the entire tooth - not to mention the ease of use for the clinician!

–Dr.DavidGarber,DMD

“ “ EndoSequence® BC Sealer:1 2g syringe15 Intra-Canal Tips1 InstructionsforUse(IFU)1 Material Safety Data Sheet

(MSDS)

Ghoneim AG, Lutfy RA, Sabet NE, Fayyad DM. Resistance to fracture of roots obturated with novel canal-filling systems. JOE. 2011; 37 (11): 1590-2

BC Obturation Kit .04 Taper: (Also available in .06)1 BC Sealer15 Intra-Canal Tips1 AssortedBCPointswheel(.04Taper)1 InstructionsforUse(IFU)1 Material Safety Data Sheet (MSDS)

Restorative Endodontics™

BC Points Replacement PacksAvailableinsize15-80(.04),15-50(.06)andBCPellets

Scan this QR code for a step-by-step tutorial for the Endosequence shaping and obturation technique.

Video Tutorial

Note: BC Sealer and BC Points are suitable for warm and cold obturation techniques.

EndoSequenceBC Obturation System ™

1

Order No. 5017560U0

Order No. 5019504U0

Mea

n Fo

rce

(n)

385

345

365

305

325

285BC Sealer™ +Impregnated/Coated Point

BC Sealer™ +Standard

Gutta Percha

Negative Control(No Root

Canal Therapy)

Fracture Resistance Comparison

Everything You Love About Cast Posts But at a Fraction of the Cost and With Zero Hassle!FEATURES •Drill-freesystem:PostmatchestheshapecreatedbytheEndoSequenceFiles.Similartoacastpost! •HighZirconiacontent(68%)givesincreasedstrength •Lowmodulusofelasticity(49GPf)promotesnaturalmovementofsurroundingtoothstructure •Factorysilanationensuresproperchemicalandmicro-mechanicalbondingfordualandlightcureresins •Highradiopacityforcrisppost-opradiographs •Whitecompositefibercompositionidealforhighlyestheticrestorations •Receivedanexcellentratingonasurveyconductedbyanationallyrecognizedthirdpartyproductevaluationcompany.*

TEChNIqUE •Simplyburnouttheneccessaryamountofguttapercha

or pre-cut the cone to create the desired apical plug.

K0165 EndoSequence® Post Starter Kit (.04 Taper):5ea.(sizes.50-1.1) EndoSequencePosts(.04Taper)

2 DoubleEndedBurnoutPluggers(.04Taper)1 UniversalFinishingDiamond**1 Hand Driver1 InstructionsforUse(IFU)

EndoSequenceFile/Post Drill (.04 Taper)

EndoSequence Postto be Used (.04 Taper)

TipSize30 TipSize.50TipSize50 TipSize.70

TipSize70(.04TaperOnly) TipSize.90TipSize80(.04TaperOnly) TipSize1.1

EndoSequence Post General Selection Guidelines

* Survey results available upon request. ** Diamond is used manually in a watch-winding motion to remove any gutta percha tags and/or sealer from canal wall prior to applying bonding agent and EndoSequence® Core Build-Up Material™

Scan this QR code for a step-by-step tutorial for the Endosequence post placement technique.

Video Tutorial

EndoSequenceFiber Post System

EndoSequencePosts(5/Pack)

Tip ID TipSize .04 Taper

Yellow .50 5013508U0

Red .70 5013509U0

Blue .90 5013510U0

Green 1.1 5013511U0

Order No. 5015623U0

Elasticity Modulus

GPa

250

200

150

100

50

0%

200

120141

4925

Steel Titanium Carbon EndoSequence Dentin

Order No. 5023032U0

Order No. 5019354U0

Features: •Smallest Head in the Industry •Cordless •5 Programmable Settings •AutoReverse •TorqueControl •SpeedRange:200-1,000rpm •AAARechargableBatteries •1yearwarranty *

Order No. 5021327U0

The Complete EndoSequence® System

EndoSequence® Introductory Kit: (Not shown above. See contents below)2 Expeditor.04Taper,21/16mm(4/pk) 1 EndoSequenceFiberPostKit.04Taper2 Small/Extra-Small.04Taper,25mmAsst(4/pk) 1 EndoSequenceBCSealer3 Medium.04Taper,25mmAsst(4/pk) 1 EndoSequenceChairsideGuide2 Large.04Taper,25mmAsst(4/pk) 1 RealworldEndo/EndoSequenceDVD1 BCPointsAsstwheel.04,15-60mm 1 EndoSequenceInstructionalInfo

2013 READERS’CHOICE AWARD

R

R

R

R

R

R

R

R

R

R

*

*Set Includes Motor, Head, Charging Base

EndoSequence® Starter Kit: (Shown above. See contents below)5 Expeditor.04Taper,21/16mm(4/pk) 5 Large.04Taper,31mmAsst(4/pk) 1 BCPointsAsstwheel.04,15-60mm5 Small/Extra-Small.04Taper,21mmAsst(4/pk) 5 Extra-Large.04Taper,21mmAsst(4/pk) 1 EndoSequenceCanalClean(100mL)5 Small/Extra-Small.04Taper,25mmAsst(4/pk) 5 Extra-Large.04Taper,25mmAsst(4/pk) 1 EndoSequenceLubricant5 Small/Extra-Small.04Taper,31mmAsst(4/pk) 5 KontrolFlexStiffK-File.08Taper,25mm(6/pk) 1 EndoSequenceBCSealer5 Medium.04Taper,21mmAsst(4/pk) 5 KontrolFlexStiffK-File.10Taper,25mm(6/pk) 1 EndoSequenceChairsideGuide5 Medium.04Taper,25mmAsst(4/pk) 5 KontrolFlexStiffK-File.15Taper,25mm(6/pk) 1 RealworldEndo/EndoSequenceDVD5 Medium.04Taper,31mmAsst(4/pk) 5 GatesGliddenAsst,50-150mm(6/pk) 1 EndoSequenceInstructionalInfo5 Large.04Taper,21mmAsst(4/pk) 1 K000032EndoSequenceAccessKit * Handpiece sold separately5 Large.04Taper,25mmAsst(4/pk) 1 K01652EndoSequencePostStarterKit(.04Taper)

©2013BrasselerUSA.Allrightsreserved. B-3958-7.5M-04.14-RRD

StrongandVersatile• Fiberreinforced,highfillercontentformulaprovidesoptimalstrength.• Dualpurpose:Balancedviscosityallowsittobeusedasacorebuild-upandpostcement.• Dualcure• Convenientsyringeorcartridgedelivery.• Receivedanexcellentratingonasurveyconductedbyanationally recognizedthirdpartyproductevaluationcompany.

A2:Simulates natural

dentition

Opaceous White:Facilitates detection

of margins

ProFile®, ProTaper®, Series 29®, K3®, LightSpeed®, Liberator®, V-Taper™, WaveOne®, Vortex®, Twisted File® and C-Files are not registered trademark of Brasseler USA. EndoSequence®, BC Sealer™, BC Points™ and BC Obturation System™ are trademarks of Brasseler USA.

Packaging Unit Order No.

100 mL 5013409U0

250 mL 5013410U0

Active Ingredients: •EDTA:3% •Cocoamphodiacetate(surfactant) •Benzalkoniumchloride(anti-bacterial)

Packaging Unit Order No.

Three 3g Syringes 5015119U0

Active Ingredients: •EDTA:15% •UreaPeroxide:10%

Packaging Unit Order No.

3 A2 syringes, 2 white syringes, 25 tips 5013885U0

KontrolFlex™

K-Files

STANDARDK-FILES(6/PACK)

STIFFK-FILES(6/PACK)19 mm

25 mm

21 mm

31 mm

•Calibratedwithstopsforlengthmeasurement•Manufacturedofhighqualitystainlesssteel•Optimalcombinationofstrengthandflexibility•OnlyK-Filesavailablein19mmlength

Compare to C-Files™

Size Stiffness Length

15-80 Standard 19*,21,25,31

06-15 Stiff 21, 25

*19mmisavailablein06-15

Survey results available upon request.

EndoSequenceCore Build-Up / Post Cement

EndoSequenceLubricant

EndoSequenceCanal Clean ™

To order call 800.841.4522 or fax 888.610.1937.In Canada call 800.363.3838 or fax 866.330.4454.Visit our website at BrasselerUSA.com

By Your Sidein Dentistry

DENTAL INSTRUMENTATION