dd = slab thickness - kiefer luft- und · pdf filedd = slab thickness concrete ceiling ......

32
1/2 DD DD = slab thickness planking lower reinforcement concrete ceiling concrete ceiling The dust cover plug has to be removed by the installation company before connecting to ductwork! (optional) Detail I - connecting bend CONCRETCOOL scale 1:5

Upload: hoanghuong

Post on 07-Feb-2018

249 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

lower reinforcement

concrete ceiling

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

(optional)

Detail I - connecting bend

CONCRETCOOL

scale 1:5

Page 2: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

planking width max. 30mm

Ø80

lower reinforcement

t

e

n

s

i

o

n

i

n

g

1/2

D

D

DD

=

sla

b th

ick

ness

concrete ceiling

planking

Detail II - vertical connection

CONCRETCOOL

1. Before start dismounting the planking, release the nut.

2. Dismount planking.

3. Remove the closing plug from the pipe. The dust cover plug has to be removed by the installation

company before connecting the ductwork.

1. Before installation the cooling pipe coil the vertical planking has to be drilled through to be

able to hold an bolt M8.

2. The screw and of the plug is placed through the drill hole and loosely screwed to the planking

using the plain washer and nut M8.

3. Place the dust cover plug into the bare pipe, then pull the pipe over the closing plug flush to

the planking.

4. First, place the u-clamp plate and afterwards the sealing sleeve on the continuing ribbed

pipe.

Second, connect the ribbed pipe with the bare pipe..

5. The sealing sleeve has to be tightened. The u-clamp plate has to be braced on both sides with

cable binders to the lower reinforcement.

Now tighten the nut of the closing plug. This causes the closing plug to expand therefore

avoiding removal of the bare pipe.

scale 1:5

Page 3: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

lower reinforcement

min

.3

0

(to

fixa

te th

e co

nn

ectio

n so

ck

et)

concrete ceiling

(optional)

concrete ceiling

installation company before connecting to ductwork!

The dust cover plug has to be removed by the

support

plate

Detail III - upwards connecting bend

CONCRETCOOL

scale 1:5

Page 4: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

lower reinforcement

The dust cover plug has to be removed by the

installation company before mounting the front plate!

Ø230

(optional)

concrete ceiling

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

Detail IV - design GLS 230

CONCRETCOOL

scale 1:5

Page 5: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

planking9

8

(8

0/1

12

)

18

0

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

concrete ceiling

filigree ceiling panel

recess min. 120mm

filigree ceiling panel

concrete ceiling

Remove the dust protection of styrofoam

before mounting the discharge profile!

CONCRETCOOL

scale 1:5

Page 6: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

concrete ceiling

Ø230

DD 180/130

180 / 130

75 105

planking

recess

coordinated as needed to ceiling perspective

(facing concrete, plaster, colour...).

filigree ceiling panel

filig

ree p

la

te th

ick

ness

filigree ceiling panel

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

The dust cover plug has to be removed by the

installation company before mounting the front plate!

(optional)

Detail V - design GLS 230 at filigree ceiling

CONCRETCOOL

scale 1:5

Page 7: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

installation company before connecting to ductwork!

The dust cover plug has to be removed by the

lower reinforcement

concrete ceiling

Ø80

Ø360

concrete ceiling

(optional)

Remove the dust cover plug before

mounting the front plate!

Detail VI - design GLS 360 ZA

CONCRETCOOL

scale 1:5

Page 8: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

lower reinforcement

(optional)

(customer to supply)

concrete ceiling

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

Detail VII - alternative connection of the canal system

CONCRETCOOL

scale 1:5

Page 9: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

planking

lower reinforcement

98

(8

0/1

12

)

18

0

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

concrete ceiling

Remove the dust protection of styrofoam

before mounting the discharge profile!

concrete ceiling

lower reinforcement

Detail VIII - design INDUL V24 NB in concrete ceiling

CONCRETCOOL

scale 1:5

Page 10: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

98

(8

0/1

12

)

18

0

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

planking

lower reinforcement

concrete ceiling

lower reinforcement

concrete ceiling

Remove the dust protection of styrofoam

before mounting the discharge profile!

Detail X - design INDUL V45 NB in concrete ceiling

CONCRETCOOL

scale 1:5

Page 11: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

98

(8

0/1

12

)

18

0

1/2

D

D (1

20

mm

)

DD

=

sla

b th

ick

ness (2

40

mm

)

recess min. 120mm

planking

filigree ceiling panel

concrete ceiling

concrete ceiling

filigree ceiling panel

Remove the dust protection of styrofoam

before mounting the discharge profile!

CONCRETCOOL

scale 1:5

Page 12: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

lower reinforcement

concrete ceiling

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

(optional)

Remove the dust protection of styrofoam

before mounting the discharge profile!

Detail XII - connection INDUL V24 NB

CONCRETCOOL

scale 1:5

Page 13: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

concrete ceiling

DD 180/130

180 / 130

75 105

planking

recess

filigree ceiling panel

filig

ree p

la

te th

ick

ness

view "X"

filigree ceiling panel

concrete ceiling

coordinated as needed to ceiling perspective

(facing concrete, plaster, colour...).

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

(optional)

Remove the dust protection of styrofoam

before mounting the discharge profile!

Detail XIII - connection INDUL V24 NB in filigree ceiling

CONCRETCOOL

scale 1:5

Page 14: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

view "X"

planking

lower reinforcement

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

(optional)

concrete ceiling

Remove the dust protection of styrofoam

before mounting the discharge profile!

Detail XIV - connection INDUL V45 NB

CONCRETCOOL

scale 1:5

Page 15: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

concrete ceiling

DD 180/130

180 / 130

75 105

recess

filigree ceiling panel

filig

ree p

la

te th

ick

ness

view "X"

planking planking

filigree ceiling panel

concrete ceiling

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

coordinated as needed to ceiling perspective

(facing concrete, plaster, colour...).

Remove the dust protection of styrofoam

before mounting the discharge profile!

(optional)

Detail XV - connection INDUL V45 NB in filigree ceiling

CONCRETCOOL

scale 1:5

Page 16: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

180 / 130

75 105

filig

ree p

la

te th

ick

ness

recess ~140

planking planking

filigree ceiling panel

concrete ceiling

scale 1:5

The dust cover plug has to be removed by the

installation company before connecting to ductwork!

Remove the dust protection of

styrofoam before mounting

the discharge profile!

scale 1:2

60

Ø 78

16

0

10

41

64

10

0 b

zw

. 1

/2

D

D

24

scale 1:2

CONCRETCOOL

Page 17: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

210

2

1

0

230

min

.

10

0

230

23

0

min. 300

23

0

300

29

0

ribbed pipe AlMgSi 0,5 (max. 5m)

bare pipe AlMgSi 0,5 (max. 6m)

Bends

connecting bend 90°

connection bend 90°

connection bend 45°

u-bend

180° bend

z-bend (on inquiry)

Ø60

Note: deviations of the standard are order related scale 1:12.5

Legend standard pipe forms Ø 60mm

CONCRETCOOL

Page 18: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

295

min

.

12

5

250

2

5

0

295

2

95

29

5

min. 450

32

5

300

ribbed pipe AlMgSi 0,5 (max. 5m)

bare pipe AlMgSi 0,5 (max. 6m)

connecting bend 90°

connection bend 90°

connection bend 45°

u-bend

180° bend

z-bend (on inquiry)

Ø80

Note: deviations of the standard are order related scale 1:12.5

Legend standard pipe forms Ø 80mm

CONCRETCOOL

Page 19: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

scale 1:100

SUP

SUP

scale 1:100

scale 1:20

design GLS 230 see detail IV (drawing no. 32514811304)

Layout example A1: GLS 230

CONCRETCOOL

Page 20: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

design GLS 230 see

detail IV (drawing no. 32514811304)

CONCRETCOOL

Page 21: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP ETA

SUP

ETA

scale 1:100

scale 1:100

scale 1:20

design GLS 360 ZA see

detail VI (drawing no. 32514811306)

Layout example B: GLS 360 ZA

CONCRETCOOL

Page 22: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP ETA

SUP

ETA

scale 1:100

scale 1:100

scale 1:20

connecting bend see detail I (drawing no. 32514811301)

Layout example C1: INDULSNAP for supply- and extract air

CONCRETCOOL

Page 23: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

connecting bend see detail I (drawing no. 32514811301)

Layout example C2: conference coupling with INDULSNAP

CONCRETCOOL

Page 24: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP ETA

SUP

ETA

scale 1:100

Layout example C3: INDULSNAP W/D for supply air

CONCRETCOOL

Page 25: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

connecting bend see detail I (drawing no. 32514811301)

Layout example D1: INDUWALL in room partition wall

CONCRETCOOL

Page 26: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

upwards connecting bend see detail III (drawing no. 32514811303)

CONCRETCOOL

Page 27: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

upwards connecting bend see detail III (drawing no. 32514811303)

INDUWALL-outlet is not

resistant to compression

Layout example D3: INDUWALL in double floor

CONCRETCOOL

(can not be walked on).

Page 28: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

displacement air outlet by customer

scale 1:20

connecting bend see detail I (drawing no. 32514811301)

CONCRETCOOL

Page 29: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

connecting bend see detail I (drawing no. 32514811301)

Layout example F: INDUL in ceiling paneling

CONCRETCOOL

Page 30: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:50

scale 1:50

connecting bend

see detail I

(drawing no. 32514811301)

vertical connection see

detail II (drawing no. 32514811302)

Layout example G: free exhaust without air outlet

CONCRETCOOL

Page 31: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP

SUP

scale 1:100

scale 1:100

scale 1:20

connecting bend see

detail I (drawing no. 32514811301)

pipe holder

connector profile

t-piece

Ø 22 mm

scale 1:5

copper tube

Layout example H: INDUCOOL-Technics I

CONCRETCOOL

Page 32: DD = slab thickness - Kiefer Luft- und · PDF fileDD = slab thickness concrete ceiling ... lower reinforcement Detail VIII - design INDUL V24 NB in concrete ... filigree plate thickness

SUP ETA

SUP

ETA

1/2

D

D

DD

=

sla

b th

ick

ness

Ø80

planking

filigree ceiling panel

DD 180/130

180 / 130

75 105

planking

recess

coordinated as needed to ceiling perspective

(facing concrete, plaster, colour...).

filig

ree p

la

te th

ick

ness

installation company before connecting to ductwork!

The dust cover plug has to be removed by the

scale 1:8

recess ~140

Remove the dust protection of styrofoam

before mounting the discharge profile!

scale 1:2

Layout example I: INDUL embedded in concrete

CONCRETCOOL