dd = slab thickness - kiefer luft- und · pdf filedd = slab thickness concrete ceiling ......
TRANSCRIPT
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
lower reinforcement
concrete ceiling
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
(optional)
Detail I - connecting bend
CONCRETCOOL
scale 1:5
planking width max. 30mm
Ø80
lower reinforcement
t
e
n
s
i
o
n
i
n
g
1/2
D
D
DD
=
sla
b th
ick
ness
concrete ceiling
planking
Detail II - vertical connection
CONCRETCOOL
1. Before start dismounting the planking, release the nut.
2. Dismount planking.
3. Remove the closing plug from the pipe. The dust cover plug has to be removed by the installation
company before connecting the ductwork.
1. Before installation the cooling pipe coil the vertical planking has to be drilled through to be
able to hold an bolt M8.
2. The screw and of the plug is placed through the drill hole and loosely screwed to the planking
using the plain washer and nut M8.
3. Place the dust cover plug into the bare pipe, then pull the pipe over the closing plug flush to
the planking.
4. First, place the u-clamp plate and afterwards the sealing sleeve on the continuing ribbed
pipe.
Second, connect the ribbed pipe with the bare pipe..
5. The sealing sleeve has to be tightened. The u-clamp plate has to be braced on both sides with
cable binders to the lower reinforcement.
Now tighten the nut of the closing plug. This causes the closing plug to expand therefore
avoiding removal of the bare pipe.
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
lower reinforcement
min
.3
0
(to
fixa
te th
e co
nn
ectio
n so
ck
et)
concrete ceiling
(optional)
concrete ceiling
installation company before connecting to ductwork!
The dust cover plug has to be removed by the
support
plate
Detail III - upwards connecting bend
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
lower reinforcement
The dust cover plug has to be removed by the
installation company before mounting the front plate!
Ø230
(optional)
concrete ceiling
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
Detail IV - design GLS 230
CONCRETCOOL
scale 1:5
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
planking9
8
(8
0/1
12
)
18
0
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
concrete ceiling
filigree ceiling panel
recess min. 120mm
filigree ceiling panel
concrete ceiling
Remove the dust protection of styrofoam
before mounting the discharge profile!
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
concrete ceiling
Ø230
DD 180/130
180 / 130
75 105
planking
recess
coordinated as needed to ceiling perspective
(facing concrete, plaster, colour...).
filigree ceiling panel
filig
ree p
la
te th
ick
ness
filigree ceiling panel
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
The dust cover plug has to be removed by the
installation company before mounting the front plate!
(optional)
Detail V - design GLS 230 at filigree ceiling
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
installation company before connecting to ductwork!
The dust cover plug has to be removed by the
lower reinforcement
concrete ceiling
Ø80
Ø360
concrete ceiling
(optional)
Remove the dust cover plug before
mounting the front plate!
Detail VI - design GLS 360 ZA
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
lower reinforcement
(optional)
(customer to supply)
concrete ceiling
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
Detail VII - alternative connection of the canal system
CONCRETCOOL
scale 1:5
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
planking
lower reinforcement
98
(8
0/1
12
)
18
0
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
concrete ceiling
Remove the dust protection of styrofoam
before mounting the discharge profile!
concrete ceiling
lower reinforcement
Detail VIII - design INDUL V24 NB in concrete ceiling
CONCRETCOOL
scale 1:5
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
98
(8
0/1
12
)
18
0
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
planking
lower reinforcement
concrete ceiling
lower reinforcement
concrete ceiling
Remove the dust protection of styrofoam
before mounting the discharge profile!
Detail X - design INDUL V45 NB in concrete ceiling
CONCRETCOOL
scale 1:5
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
98
(8
0/1
12
)
18
0
1/2
D
D (1
20
mm
)
DD
=
sla
b th
ick
ness (2
40
mm
)
recess min. 120mm
planking
filigree ceiling panel
concrete ceiling
concrete ceiling
filigree ceiling panel
Remove the dust protection of styrofoam
before mounting the discharge profile!
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
lower reinforcement
concrete ceiling
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
(optional)
Remove the dust protection of styrofoam
before mounting the discharge profile!
Detail XII - connection INDUL V24 NB
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
concrete ceiling
DD 180/130
180 / 130
75 105
planking
recess
filigree ceiling panel
filig
ree p
la
te th
ick
ness
view "X"
filigree ceiling panel
concrete ceiling
coordinated as needed to ceiling perspective
(facing concrete, plaster, colour...).
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
(optional)
Remove the dust protection of styrofoam
before mounting the discharge profile!
Detail XIII - connection INDUL V24 NB in filigree ceiling
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
view "X"
planking
lower reinforcement
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
(optional)
concrete ceiling
Remove the dust protection of styrofoam
before mounting the discharge profile!
Detail XIV - connection INDUL V45 NB
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
concrete ceiling
DD 180/130
180 / 130
75 105
recess
filigree ceiling panel
filig
ree p
la
te th
ick
ness
view "X"
planking planking
filigree ceiling panel
concrete ceiling
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
coordinated as needed to ceiling perspective
(facing concrete, plaster, colour...).
Remove the dust protection of styrofoam
before mounting the discharge profile!
(optional)
Detail XV - connection INDUL V45 NB in filigree ceiling
CONCRETCOOL
scale 1:5
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
180 / 130
75 105
filig
ree p
la
te th
ick
ness
recess ~140
planking planking
filigree ceiling panel
concrete ceiling
scale 1:5
The dust cover plug has to be removed by the
installation company before connecting to ductwork!
Remove the dust protection of
styrofoam before mounting
the discharge profile!
scale 1:2
60
Ø 78
16
0
10
41
64
10
0 b
zw
. 1
/2
D
D
24
scale 1:2
CONCRETCOOL
210
2
1
0
230
min
.
10
0
230
23
0
min. 300
23
0
300
29
0
ribbed pipe AlMgSi 0,5 (max. 5m)
bare pipe AlMgSi 0,5 (max. 6m)
Bends
connecting bend 90°
connection bend 90°
connection bend 45°
u-bend
180° bend
z-bend (on inquiry)
Ø60
Note: deviations of the standard are order related scale 1:12.5
Legend standard pipe forms Ø 60mm
CONCRETCOOL
295
min
.
12
5
250
2
5
0
295
2
95
29
5
min. 450
32
5
300
ribbed pipe AlMgSi 0,5 (max. 5m)
bare pipe AlMgSi 0,5 (max. 6m)
connecting bend 90°
connection bend 90°
connection bend 45°
u-bend
180° bend
z-bend (on inquiry)
Ø80
Note: deviations of the standard are order related scale 1:12.5
Legend standard pipe forms Ø 80mm
CONCRETCOOL
scale 1:100
SUP
SUP
scale 1:100
scale 1:20
design GLS 230 see detail IV (drawing no. 32514811304)
Layout example A1: GLS 230
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
design GLS 230 see
detail IV (drawing no. 32514811304)
CONCRETCOOL
SUP ETA
SUP
ETA
scale 1:100
scale 1:100
scale 1:20
design GLS 360 ZA see
detail VI (drawing no. 32514811306)
Layout example B: GLS 360 ZA
CONCRETCOOL
SUP ETA
SUP
ETA
scale 1:100
scale 1:100
scale 1:20
connecting bend see detail I (drawing no. 32514811301)
Layout example C1: INDULSNAP for supply- and extract air
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
connecting bend see detail I (drawing no. 32514811301)
Layout example C2: conference coupling with INDULSNAP
CONCRETCOOL
SUP ETA
SUP
ETA
scale 1:100
Layout example C3: INDULSNAP W/D for supply air
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
connecting bend see detail I (drawing no. 32514811301)
Layout example D1: INDUWALL in room partition wall
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
upwards connecting bend see detail III (drawing no. 32514811303)
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
upwards connecting bend see detail III (drawing no. 32514811303)
INDUWALL-outlet is not
resistant to compression
Layout example D3: INDUWALL in double floor
CONCRETCOOL
(can not be walked on).
SUP
SUP
scale 1:100
scale 1:100
displacement air outlet by customer
scale 1:20
connecting bend see detail I (drawing no. 32514811301)
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
connecting bend see detail I (drawing no. 32514811301)
Layout example F: INDUL in ceiling paneling
CONCRETCOOL
SUP
SUP
scale 1:50
scale 1:50
connecting bend
see detail I
(drawing no. 32514811301)
vertical connection see
detail II (drawing no. 32514811302)
Layout example G: free exhaust without air outlet
CONCRETCOOL
SUP
SUP
scale 1:100
scale 1:100
scale 1:20
connecting bend see
detail I (drawing no. 32514811301)
pipe holder
connector profile
t-piece
Ø 22 mm
scale 1:5
copper tube
Layout example H: INDUCOOL-Technics I
CONCRETCOOL
SUP ETA
SUP
ETA
1/2
D
D
DD
=
sla
b th
ick
ness
Ø80
planking
filigree ceiling panel
DD 180/130
180 / 130
75 105
planking
recess
coordinated as needed to ceiling perspective
(facing concrete, plaster, colour...).
filig
ree p
la
te th
ick
ness
installation company before connecting to ductwork!
The dust cover plug has to be removed by the
scale 1:8
recess ~140
Remove the dust protection of styrofoam
before mounting the discharge profile!
scale 1:2
Layout example I: INDUL embedded in concrete
CONCRETCOOL