dcs series data sheet 0110002-03
TRANSCRIPT
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 1/8
Applications
• AutomotiveElectronics
• RackmountATESystem
• BatteryCharging
DCS Series1kW,1.2kW,&3kW
AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 2/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
DCS Series
DCS Applications
TheDCSFamilyisideallysuitedforawiderangeofapplicationsrequiringDCpowernasmallformfactor.Applicationsrangefrommanufacturingtestandburn-inof
utomotivecomponents,avionicselectronics,telecommunicationsandconsumers
productstobeamsteering,processcontrolandlaboratoryR&Duse.
TheDCSFamilyiscomprisedof1KW,1.2KWand3KWprogrammablepowersupplies
tilizing switchmode technology to achieve high power density in a low prole
chassis.Thedesignplatformprovidesahighlyreliablepowersupplyforyearsof
constantuse.Theuniquedesignisavailableinavarietyofmaximumvoltagesfrom
8Vto600Vandmaximumcurrentsfrom2Ato350Awithlowrippleandnoise.
Thisuser-friendlyplatformcanbecontrolledformthefrontpanelwith10-turn
potentiometerstoadjustvoltage,currentandOVPsettings.LEDsindicate
overtemperature,remoteprogramming,shutdownandovervoltageprotection
RemotecontroloptionsallowfullcomputercontrolthroughIEEE-488(optionM9C),LXI
StandardCompliant*EthernetLAN(optionM130)orRS-232(M9C,M130,M131)
DCS Series: 1 kW, 1.2 kW, & 3 kW
Automotive Component Test
The16-bitresolutionoftheEthernet
programmingandhardwaretriggeringallows
fordetailedsequencingassociatedwithbattery
uctuation simulation. The tight load regulation
capabilityoftheDCSseriesmakesitasuperior
sourceforvalidationandacceptancetesting
andburn-inofautomotivecomponents.The20Vmodels,inparticular,provideafullrangeof
testingtosimulatebatteryconditions.Margin
testingof12Vand14Vnominalcomponents,
suchaselectroniccontrolunits(ECU)and
electromechanicalcomponents,iseasily
achieved
Rackmount ATE Systems
ThehighpowerdensityoftheDCsseries
makesitidealforATESystemintegration.
Thewidevarietyofvoltageandcurrent
combinationsin1Uand2Uheightsallows
multiplevoltageoutputsinasmallamountof
space.Thewidevarietyofcontrolmethods
possibleallowseasyintegrationintolegacysystemsaswellashighspeedsystems.
Battery Charging
Batterychargingrequireshighaccuracyvol
andstablecurrentoutputforfastbulkand
absorptionphasechargingandhighaccurac
and stable voltage for oat charging to avoid
“gassing”thebattery.TheDCSseriesprovi
ahighaccuracyvoltageoutputtooptimize
batterycharging.Withtheremoteinterfaceoptions,thechargingprocesscaneasilybe
automatedforvolumeproduction.
* http://www.lxistandard.org
•WideSelectionofOutputVoltages
Voltagerangesfrom0-8VDCto0-600
VDC;currentlevelsfrom1.7Ato350A
•HighPowerDensity
•1kWor1.2kWofpowerinapackageonly1.75incheshigh
•3kWofpowerinapackageonly
3.5incheshigh
•Improvedprogrammingresolutionwith
Ethernetinterface
•16bitcontrol
•0.002%programmingandreadback
resolution
•TightRegulation
•Lineregulation:0.1%
•Loadregulation:0.1%
•FlexibleRemoteProgrammingOptions
•Ethernet/RS-232•GPIBIEEE-488/RS-232
•Analog:Selectableremote
programmingforvoltage,current
andOVP.Optionalisolatedanalog
programming
•Software
• LabVIEW®driverforGPIB
• IVI-comdriverforEthernet
•5YearWarranty
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 3/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
DCS Series
Output
Voltage and Current1 kW Model Voltage Current
DCS8-125E 0-8 0-125
DCS10-100E 0-10 0-100
DCS20-50E 0-20 0-50
DCS33-33E 0-33 0-33
DCS40-25E 0-40 0-25DCS50-20E 0-50 0-20
DCS60-18E 0-60 0-18
DCS80-13E 0-80 0-13
DCS100-10E 0-100 0-10
DCS150-7E 0-150 0-7
DCS300-3.5E 0-300 0-3.5
DCS600-1.7E 0-600 0-1.7
1.2 kW Model Voltage Current
DCS8-140E 0-8 0-140
DCS10-120E 0-10 0-120
DCS20-60E 0-20 0-60
DCS33-36E 0-30 0-36
DCS40-30E 0-40 0-30
DCS50-24E 0-50 0-24
DCS60-20E 0-60 0-20
DCS80-15E 0-80 0-15
DCS100-12E 0-100 0-12
DCS150-8E 0-150 0-8
DCS300-4E 0-300 0-4
3 kW Model Voltage Current
DCS8-350E 0-8 0-350
DCS12-250E 0-12 0-250
DCS20-150E 0-20 0-150
DCS40-75E 0-40 0-75
DCS55-55E 0-55 0-55
DCS60-50E 0-60 0-50
DCS80-37E 0-80 0-37DCS150-20E 0-150 0-20
Voltage Resolution:0.02%
Ripple (mV RMS or P-P):Seetable
Regulation (Line or Load)
Voltage:0.1%
Current:0.1%
Transient Response:Typicallyrecoversin500µs
(1&1.2kW)or1ms(3kW)to1%ofsteady-state
outputvoltage(within1%ofVmax)for70-100%or
100-70%loadchange.
Stability:±0.05%ofmaximumvoltageorcurrent
over8hoursafter30minutewarm-uptimeatxed line, load and temperature
Efciency:Seetable
Temperature Coefcient:0.02%/°Cofmaximum
outputvoltage;0.03%/°Cofmaximumoutput
current
InputVoltage and Frequency
1 kW:200-250VAC,singlephase,8Atypical,
47-63Hz;or100-132VAC,singlephase,15A
typical,47-63Hz,internaljumperselectable(see
M1option)
1.2 kW: 200-250VAC,singlephase,9Atypical,47-63Hz;or100-132VAC,singlephase,18A
typical,47-63Hz,internaljumperselectable(see
M1option)
3 kW:190-250VAC,threephase,14A
typical,47-63Hz;or200-250VAC,singlephase,
20Atypical,47-63Hz
Note:Maximumpoweroutputof3kWsupplies
mustbelimitedto2.5kWforsinglephaseinput
Soft Start:Linecurrentislowerthanfullload
peakvalueduringturn-onorpowerapplication
afterrestart
GeneralOperating Temperature:0°Cto50°C(no
derating)
Storage Temperature:-55°Cto85°C
Humidity Range:0to80%RH,
noncondensing
Meter Accuracy:1%offullscale+1count
Max. Voltage Differential from Output to Safety
Ground:150VDC
Remote Start/Stop and Interlock:TTL
compatibleinputor12-250VAC
(12-130VDC)oracontactclosure
Cooling:Internalfan,overtemperatureshutdownifinternalheatsinkexceeedssettemperature
Remote Sense: Themaximumallowedsense
linedropis4Vperline(2VontheDCS8and10V
1kWand1.2kWmodelsand1V/lineforall3kw
models)
Remote Programming:Externaljumperviarear
panelconnectorJ3
Overvoltage Protection:Crowbartypeadjustable
from5-110%ofratedoutputusingfrontpanel
control(localorremoteprogramselectableviaJ3
jumper)
Remote Analog Programming Linearity:±1%
Accuracy:±5%
Regulatory Compliance:CEMark(1,1.2,3kW);
FCCPart15ClassA,UL1012,CSA22.2#220(1
and1.2kWonly)
Dimensions1 kW and 1.2 kW:1Uor1.75”
(44mm)Hx19”(482mm)Wx17.5”(444m
3 kW:2Uor3.5”(88mm)Hx
19”(482mm)Wx17.5”
(444mm)D
Weight1 kW and 1.2 kW:19lbs.(8.6kg)
3 kW:33lbs.(15kg)
Shipping Weight
1 kW and 1.2 kW:24lbs.(10.9kg)
3 kW:42lbs.(19kg)
Options & AccessoriesM1: Factory congured for 115 VAC input (1 k
and1.2kWunitsonly)
M9C:InternalIEEE-488/RS-232Interface(can
onlysupport12-bitslaves)
M13:Lockingshafts(frontpanelpotentiometers)
M32: Master/slave paralleling cable congure
twounits
M33:Replaceinputconnectorwithterminalb
(3kWonly)
M51A:Isolatedanalogprogrammingcontrolo
V/I/OVPandisolatedV/Imonitoroutputsupto
500Vrelativetothesupply’sreturnline
M85:12-bitslaveinterfaceoptionforusewit
orM130master(3ft.controlcableincluded)
M102:Frontpanelbindingpostsfor1kwor
1.2kw, Models ≤30A, ≤100V. Not compatiblewithM9C,M85,M130,M131,M133,M135,
M136
M130:LXIcompliant10/100BaseTEthernet
remotecontrolmasterinterface;includesweb
serverfordirectcontrolofpowersupplyviaw
browser
M131:16-bitslaveinterfaceoptionforusew
M130master(3ft.controlcableincluded)
M133:Outputdisconnectandpolarityreversa
controlledviaSCPIcommands.Limitedto1k
1.2 kw, ≤100V, ≤60A
M135:M130&M133combination
M136:M131&M133combination
SoftwareIVI-ComandLabviewdriversavailableforfree
downloadathttp://www.elgar.com/support/
downloads.htm
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 4/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
Model
Constant Current Mode* Temp.Coeff.
%/°C(Typ.)
CurrentDrift
%I0 Max.(Typ.)
Programming Con-stants, Current Mode
Input Current, ANominal
Efciency%
(Typ.)
RegulationLine andLoad%
Combined
Ripple(RMS)**
mA Ohms/A V/A
230VSinglePhase
208VThreePhase
DCS Series: 1KW
DCS8-125E 0.2 160 0.03 0.05 40
0-10V=
0-100%Io
or
0-5V=
0-100%Io
8 N/A 82
DCS10-100E 0.2 128 0.03 0.05 50 8 N/A 82
DCS20-50E 0.2 25 0.03 0.05 100 8 N/A 82
DCS33-33E 0.2 10 0.03 0.05 151.5 8 N/A 84
DCS40-25E 0.2 7 0.03 0.05 200 8 N/A 84
DCS50-20E 0.2 7 0.03 0.05 250 8 N/A 84
DCS60-18E 0.2 6 0.03 0.05 277.8 8 N/A 86
DCS80-13E 0.2 4 0.03 0.05 384.6 8 N/A 86
DCS100-10E 0.2 3 0.03 0.05 500 8 N/A 86DCS150-7E 0.2 2 0.03 0.05 714.3 8 N/A 86
DCS300-3.5E 0.2 1 0.03 0.05 1428.6 8 N/A 86
DCS600-1.7E 0.2 1 0.03 0.05 2941.2 9.5 N/A 86
DCS Series: 1.2 kW
DCS8-140E 0.2 180 0.03 0.05 35.7
0-10V=
0-100%Io
or0-5V=
0-100%Io
9 N/A 82
DCS10-120E 0.2 153 0.03 0.05 41.7 9 N/A 82
DCS20-60E 0.2 30 0.03 0.05 83.3 9 N/A 82
DCS33-36E 0.2 11 0.03 0.05 138.9 9 N/A 84
DCS40-30E 0.2 9 0.03 0.05 166.7 9 N/A 84
DCS50-24E 0.2 8.5 0.03 0.05 208.3 9 N/A 84
DCS60-20E 0.2 6.6 0.03 0.05 250.0 9 N/A 85
DCS80-15E 0.2 6 0.03 0.05 333.3 9 N/A 85
DCS100-12E 0.2 3.6 0.03 0.05 416.7 9 N/A 85
DCS150-8E 0.2 2.3 0.03 0.05 625.0 9 N/A 85
DCS300-4E 0.2 1.2 0.03 0.05 1250.0 9 N/A 85
DCS Series: 3 kW
DCS8-350E 0.2 870 0.03 0.05 14.3
0-10V=
0-100%Io
or
0-5V=
0-100%Io
24 13 82
DCS12-250E 0.2 400 0.03 0.05 20 26 14 82
DCS20-150E 0.2 100 0.03 0.05 33.3 26 14 82
DCS40-75E 0.2 75 0.03 0.05 66.7 26 14 86
DCS55-55E 0.2 40 0.03 0.05 90.9 26 14 82
DCS60-50E 0.2 33 0.03 0.05 100 26 14 86
DCS80-37E 0.2 20 0.03 0.05 135 26 14 86
DCS150-20E 0.2 10 0.03 0.05 250 26 14 86
*Typicalresolutionis0.02%**RMSrippletypicalfrom20Hzto300kHz***Consultfactory
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 5/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
Model
Output Power
CombinedRegula-
tionLine and
Load %
Constant Voltage Mode*
Temp.Coeff.
Voltage%
/°C (Typ)
VoltageDrift%Vmax
(Typ)
Programming Con-stants Voltage Mode
Voltage
VDC
Current
ADC@ 50°C Ripple
Noise
(P-P)
TransientResponseTime µs
(Typ)
Ohms/
V V/V
DCS Series: 1KW
DCS8-125E 0-8 0-125 0.2 4mV 60mV 500 0.02 0.05 625
0-10V=
0-100%Vo
or
0-5V=
0-100%Vo
DCS10-100E 0-10 0-100 0.2 4mV 60mV 500 0.02 0.05 500
DCS20-50E 0-20 0-50 0.2 4mV 60mV 500 0.02 0.05 250
DCS33-33E 0-33 0-33 0.2 4mV 60mV 500 0.02 0.05 151.5
DCS40-25E 0-40 0-25 0.2 4mV 60mV 500 0.02 0.05 125
DCS50-20E 0-50 0-20 0.2 4mV 60mV 500 0.02 0.05 100
DCS60-18E 0-60 0-18 0.2 4mV 60mV 500 0.02 0.05 83
DCS80-13E 0-80 0-13 0.2 4mV 60mV 500 0.02 0.05 62.5
DCS100-10E 0-100 0-10 0.2 6mV 60mV 500 0.02 0.05 50DCS150-7E 0-150 0-7 0.2 12mV 160mV 500 0.02 0.05 33.3
DCS300-3.5E 0-300 0-3.5 0.2 20mV 200mV 500 0.02 0.05 16.67
DCS600-1.7E 0-600 0-1.7 0.2 50mV 300mV 500 0.02 0.05 8.33
DCS Series: 1.2 kW
DCS8-140E 0-8 0-140 0.2 5mV 60mV 500 0.02 0.05 625
0-10V=
0-100%Vo
or0-5V=
0-100%Vo
DCS10-120E 0-10 0-120 0.2 5mV 60mV 500 0.02 0.05 500
DCS20-60E 0-20 0-60 0.2 5mV 60mV 500 0.02 0.05 250
DCS33-36E 0-33 0-36 0.2 5mV 60mV 500 0.02 0.05 151.5
DCS40-30E 0-40 0-30 0.2 5mV 60mV 500 0.02 0.05 125
DCS50-24E 0-50 0-24 0.2 5mV 60mV 500 0.02 0.05 100
DCS60-20E 0-60 0-20 0.2 5mV 60mV 500 0.02 0.05 83
DCS80-15E 0-80 0-15 0.2 5mV 60mV 500 0.02 0.05 62.5
DCS100-12E 0-100 0-12 0.2 10mV 60mV 500 0.02 0.05 50
DCS150-8E 0-150 0-8 0.2 15mV 160mV 500 0.02 0.05 33.3
DCS300-4E 0-300 0-4 0.2 25mV 200mV 500 0.02 0.05 16.67
DCS Series: 3 kW
DCS8-350E 0-8 0-350 0.2 15mV 100mV 1000 0.02 0.05 625
0-10V=
0-100%Vo
or
0-5V=
0-100%Vo
DCS12-250E 0-12 0-250 0.2 10mV 100mV 1000 0.02 0.05 416.7
DCS20-150E 0-20 0-150 0.2 10mV 100mV 1000 0.02 0.05 250
DCS40-75E 0-40 0-75 0.2 20mV 100mV 1000 0.02 0.05 125
DCS55-55E 0-55 0-55 0.2 20mV 100mV 1000 0.02 0.05 90.9
DCS60-50E 0-60 0-50 0.2 20mV 100mV 1000 0.02 0.05 83
DCS80-37E 0-80 0-37 0.2 20mV 100mV 1000 0.02 0.05 62.5
DCS150-20E 0-150 0-20 0.2 30mV 200mV 1000 0.02 0.05 33.3
*Typicalresolutionis0.02%**RMSrippletypicalfrom20Hzto300kHz***Consultfactory
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 6/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
Model
Programming Accuracy
Readback AccuracyM130/M131/M9C Options
Voltage0.1% +
Current0.1% +
OVP0.5% +
Voltage0.1% +
Current0.1 +
DCS Series: 1KW
DCS8-125E 8mV 500mA 44mV 12mV 500mA
DCS10-100E 10mV 400mA 55mV 15mV 400mA
DCS20-50E 20mV 200mA 110mV 30mV 200mA
DCS33-33E 33mV 132mA 182mV 50mV 132mA
DCS40-25E 40mV 100mA 220mV 60mV 100mA
DCS50-20E 50mV 80mA 275mV 75mV 80mA
DCS60-18E 60mV 72mA 330mV 90mV 72mA
DCS80-13E 80mV 52mA 440mV 120mV 52mA
DCS100-10E 100mV 40mA 550mV 150mV 40mA
DCS150-7E 150mV 28mA 825mV 225mV 28mA
DCS300-3.5E 300mV 14mA 1650mV 450mV 14mA
DCS600-1.7E 600mV 6.8mA 3300mV 900mV 7mA
DCS Series: 1.2 kW
DCS8-140E 8mV 560mA 44mV 12mV 560mA
DCS10-120E 10mV 480mA 55mV 15mV 480mA
DCS20-60E 20mV 240mA 110mV 30mV 240mA
DCS33-36E 33mV 144mA 182mV 50mV 144mA
DCS40-30E 40mV 120mA 220mV 60mV 120mA
DCS50-24E 50mV 96mA 275mV 75mV 96mA
DCS60-20E 60mV 80mA 330mV 90mV 80mA
DCS80-15E 80mV 60mA 440mV 120mV 60mA
DCS100-12E 100mV 48mA 550mV 150mV 48mA
DCS150-8E 150mV 32mA 825mV 225mV 32mA
DCS300-4E 300mV 16mA 1650mV 450mV 16mA
DCS Series: 3 kW
DCS8-350E 8mV 1400mA 44mV 12mV 1400mA
DCS12-250E 12mV 1000mA 66mV 18mV 1000mA
DCS20-150E 20mV 600mA 110mV 30mV 600mA
DCS40-75E 40mV 300mA 220mV 60mV 300mADCS55-55E 55mV 220mA 303mV 83mV 220mA
DCS60-50E 60mV 200mA 330mV 90mV 200mA
DCS80-37E 80mV 148mA 440mV 120mV 148mA
DCS150-20E 150mV 80mA 825mV 225mV 80mA
8/23/2019 DCS Series Data Sheet 0110002-03
http://slidepdf.com/reader/full/dcs-series-data-sheet-0110002-03 7/8
E L G A R E L E C T R O N I C S C O R P O R A T I O N
Tel:858-450- 0085•TollFree:800-733-5427•Fax:858-458-0267•Europe:(+31)(0)302650946•[email protected]•www.elgar.com
1.10
17.52
(28)
(445)
1.00(25)
Top View
1.25
19.00
1.72
(482)
(32)(43)
Front View
Dimensions in inches (millimeters)
16.90(429)
Options &
Rear View
1KW and 1.2KW
1.10
17.52
1.00
(28)
(445)
(25)
Top View
3.00
19.00
3.46
(482)
(76)(87)
Front View
16.90(429)
Rear View
3KW
J3ProgramandSense
1 90-250VACRemoteShutdown 14 TTLShutdown
2 ShutdownReturn 15 +12VDC
3 OVPProgram 16 1mACurrentSource(OVP)
4 Remote/LocalStatusIndicator 17 OVPIndicator
5 ModeStatusIndicator 18 ThermalS/DNStatus
6 Ground 19 0-5VVoltageMonitor
7 0-5VCurrentMonitor 20 RemoteVoltageSelect
8 VoltageControl 21 1mACurrentSource(V)
9 VoltageProgramInput 22 1mACurrentSource(I)
10 CurrentProgramUnit 23 RemoteCurrentSelect
11 CurrentControl 24 Return
12 ReturnSense 25 POSOutput(8-100VModelsOnly)
13 POSSense(8-100VModelsOnly)
InputVoltageOptions
M1 Factory congured for 115 VAC input (1 and 1.2 kW only)
RemoteInterfaceOptions
M9C InternalIEEE-488/RS232interface(Supportsonly12-bitslaves)
M13 Lockingshafts(frontpanelpotentiometers)
M32 Master/slave cable congured for two or more units
M33 Replaceinputconnectorwithterminalblock(3kWonly)
M51A Isolatedanalogprogrammingcontrol
M102 Front Panel Binding Posts (1KW and 1.2KW only≤30A)
M85 12-bitslaveinterface
M130 Ethernet/RS232Interface(Supportsboth12-&16-bitslaves)
M131 16-bitslaveinterface
M133 Outputdisconnectandpolarityreversalrelays*
M135 Outputdisconnectandpolarityreversalrelays**
M136 Outputdisconnectandpolarityreversalrelays***
105-330-26 Rackslidekit(3kWonly)
* Requires M9C ** Includes option M130 ***Includes option M131
1 a n d 1 . 2
k W o n l y