10
Model KP50A KP70A KP90A KP120A KP150A KP210A Power supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3 Nominal heating capacity kW 5 7 9 12 15 21 Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19 COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 Temperature range heating ºC 2055 2055 2055 2055 2055 2055 Temperature range cooling ºC 720 720 720 720 720 720 outdoor unit compressor quantity 1 1 1 1 1 1 compressor type twinrotary twinrotary twinrotary twinrotary scroll scroll Dimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390 3. allinone design 4. Fuzzy defrosting outdoor unit: DC inverter compressor, 3 heater for defrosting, circulation pump, water flow switch optional compoments: electrical heater backup, 3waywatervalve the connection between outdoor unit and indoor applications are antifreeze no water freeze on outdoor unit. 2. function: house heating. Optional function: house cooling electrical heater backup: add USD45 3waywatervalve for sanitary hot water: add USD55 DC inverter allinone 1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC

Upload: others

Post on 15-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DC inverter all in one - best93.hr

Model KP‐50A KP‐70A KP‐90A KP‐120A KP‐150A KP‐210APower supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390

3. all‐in‐one design

4. Fuzzy defrosting

    outdoor unit: DC inverter compressor, 3 heater for defrosting, circulation pump, water flow switch    optional compoments: electrical heater backup, 3‐way‐water‐valve    the connection between outdoor unit and indoor applications are anti‐freeze    no water freeze on outdoor unit.

2. function:                     house heating.       Optional function:    house cooling    electrical heater backup:                                add USD45    3‐way‐water‐valve for sanitary hot water:  add USD55

DC inverter all‐in‐one

1. test condition:   heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC   cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC

Page 2: DC inverter all in one - best93.hr

DC inverter compressor

DC inverter all‐in‐one ‐ installation

Page 3: DC inverter all in one - best93.hr

Model KP‐50D KP‐70D KP‐90D KP‐120D KP‐150D KP‐210DPower supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20Indoor unitElectrical heater backup kW 2 3 3 3 2+2+2 3+3+3Dimensions (W x H x D) mm 450x550x255 450x550x255 450x550x255 450x550x255 450x550x255 450x550x255outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390

3. split design

    the connection between outdoor unit and indoor square tank is refrigerant R410a, copper connective piping.    no water freeze on outdoor unit.4. Fuzzy defrosting

2. function:                     house heating.       Optional function:    house cooling

    outdoor unit: DC inverter compressor, 3 heater for defrosting    indoor square tank: circulation pump, water flow switch, electrical heater backup

    electrical heater backup:                                add USD45    3‐way‐water‐valve for sanitary hot water:  add USD55

DC inverter split

1. test condition:   heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC   cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC

Page 4: DC inverter all in one - best93.hr

DC inverter split ‐ installation 1

DC inverter compressor

Page 5: DC inverter all in one - best93.hr

DC inverter split ‐ installation 1

Page 6: DC inverter all in one - best93.hr

DC inverter split ‐ installation 2

Page 7: DC inverter all in one - best93.hr

Model KP‐50 KP‐70 KP‐90 KP‐120 KP‐150 KP‐210Power supply V/Hz/Ph 230/50/1 230/50/1 230/50/1 230/50/1 380/50/3 380/50/3Nominal heating capacity kW 5 7 9 12 15 21Nominal cooling capacity kW 4.5 6.5 8.5 11 13.5 19COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8Temperature range heating ºC 20‐55 20‐55 20‐55 20‐55 20‐55 20‐55Temperature range cooling ºC 7‐20 7‐20 7‐20 7‐20 7‐20 7‐20Indoor unitbuffer tank built‐in liter 180 180 180 180 180 180Electrical heater backup kW 2 3 3 3 2+2+2 3+3+3

Dimensions (W x H x D) mm600x1800x64

0600x1800x64

0600x1800x64

0600x1800x64

0600x1800x64

0600x1800x64

0outdoor unitcompressor quantity 1 1 1 1 1 1compressor type twin‐rotary twin‐rotary twin‐rotary twin‐rotary scroll scrollDimensions (W x H x D) mm 840x590x290 840x700x315 880x780x360 830x1230x310 930x1270x390 930x1270x390

3. split design    Optional function:    house cooling, solar panel

    outdoor unit: evaporator, fan, 3 heater for defrosting    indoor square tank: compressor, circulation pump, heat exchanger, 180 liter tank, electrical heater backup    the connection between outdoor unit and indoor square tank is refrigerant R410a, copper connective piping.

4. Fuzzy defrosting    no water freeze on outdoor unit.  No heat loss on outdoor unit

DC inverter split combo  ‐  Installation Plan

   cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC

1. test condition:

2. function:                     sanitary hot water, house heating.   

DC inverter split combo

   heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 30ºC / 35ºC

Page 8: DC inverter all in one - best93.hr

DC inverter split with tank  ‐  Application

Page 9: DC inverter all in one - best93.hr

DC inverter split combo ‐ with 180L tank inside

refrigerant part install a module. This module can remove or install

                                 quickly. It is good for after‐service and maintaince.

Page 10: DC inverter all in one - best93.hr

this unit can connect existing water tank.DC inverter split combo ‐ without tank inside