32
SS-DBH3-D www.daikinac.com 06/20 Supersedes 04/20 DBH Commercial Base Efficiency Heat Pump Direct Drive Packaged Rooftop Unit DBH Commercial 3-5 Nominal Tons 14 SEER / 11.5 EER * Complete warranty details available from your local distributor or manufacturer’s representave or at www.daikincomfort.com or www.daikinac.com

Upload: others

Post on 08-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

SS-DBH3-D www.daikinac.com 06/20Supersedes 04/20

DBH Commercial

Base Efficiency Heat PumpDirect Drive Packaged Rooftop Unit

DBH Commercial3-5 Nominal Tons

14 SEER / 11.5 EER

* Complete warranty details available from your local distributor or manufacturer’s representative or at www.daikincomfort.com or www.daikinac.com

Page 2: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Our Perfect Package:Harnessing energy-efficient performance, proven technology, and enhanced comfort for life.

Since becoming the first company in Japan to manufacture packaged

air conditioning systems, in 1951, Daikin has supported comfortable

indoor living based on the strengths and technologies that have

led to the growth of the company becoming one of the

world’s largest manufacturers of HVAC products, systems

and refrigerants.

Today, as a comprehensive global manufacturer of HVAC products

and systems, the Daikin brand is committed to being recognized

as a truly global and excellent company capable of continually

creating new value for its customers. The company plans to pursue

sustainable growth and foster business operations that consistently

harmonize with the goals of improving indoor comfort.

The group philosophy of the company includes: » Creating new value continuously for customers

» Developing world leading energy-saving technology

» Being a flexible and dynamic organization

» Allowing employees to be the driving force for the success of the company

» Fostering an atmosphere of best practices, boldness, and innovation

» Thinking and acting globally

Page 3: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

3

Contents2 Introduction 2

4 Nomenclature 4

5 Features and Benefits 5

Applications 8Serviceability 8

9 Product Specifications 9

AHRI Ratings 9Sound Data 9Expanding Cooling Data 10Electric Heater Data 16

Air Flow 17Electrical Data 19Wiring Diagrams 21

23 Dimensional Data 23

24 Electrical Connections 24

Unit Clearances 24Installation 25

Weights 25

26 Accessories 26

28 Factory Installed Options 28

28 Field Installed Options 28

29 Factory and Field Installed Options 29

Page 4: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Nomenclature

4 www.daikinac.com SS-DBH3-D

D B H 036 1 D XXX A X A

1 2 3 4,5,6 7 8 9,10,11 12 13 14

BrandD Daikin

ConfigurationB New Base Efficiency

ApplicationC CoolingG Gas HeatH Heat Pump

Nominal Cooling Capacity036 3 Tons048 4 Tons060 5 Tons

Voltage1 208-230/3/603 208-230/3/60

Supply Fan/Drive Type/MotorD Direct Drive - Standard Static

Nominal Heating CapacityGas/Electric A/C H/P Factory-Installed Electric Heat045 45,000 BTU/h XXX No Heat070 70,000 BTU/h 005 5kW090 90,000 BTU/h 010 10 kW115 115,000 BTU/h 015 15 kW140 140,000 BTU/h 016 15 kW

022 20 kW

See product specifications for heat size(s) available for each capacity.

Refrigeration SystemsA Single stage cooling modes

Heat Exchanger

X No optionsA Standard Aluminized ExchangerS Stainless Steel Exchanger

ControlsA Electro-mechanical controls

X X X X X X X X A *

15 16 17 18 19 20 21 22 23 24

Revision Levels

Major & Minor

X No Options

Power Exhaust

X No OptionsB Single point power connection for Power Exhaust

IAQ

X No Options

Service OptionsX No OptionA Powered convenience outletB Non-powered convenience outletC Hinge PanelsD Hinged Panels and Powered convenience outletE Hinged Panels and non-powered convenience outlet

ElectricalX No OptionsA Non-Fused DisconnectB Phase MonitorC Thru-the-base connectionsE Non-Fused Disconnect and Phase MonitorF Non-Fused Disconnect and Thru-the-base connectonsH Phase Monitor and Thru-the-base connectionsL Non-Fused Disconnect, Thru-the-base connectons and Phase Monitor

EconomizerX No OptionsA Ultra Low-Leak Downflow Economizer w/Enthalpy SensorB Low-Leak Downflow Economizer w/Enthalpy SensorG Ultra Low-Leak Downflow Economizer w/Dry Bulb SensorH Low-Leak Downflow Economizer w/Dry Bulb Sensor

Coils, Hail guard X No OptionsC Hail Guard

SensorsX No OptionsA RA Smoke DetectorB SA Smoke DetectorC RA & SA Smoke Detector

HP Stocking ModelsNew Daikin 3-5 Ton Direct Drive

Model Number Code StringDBH0361D000001S DBH0361DXXXAXAXXXXXXXXDBH0363D000001S DBH0363DXXXAXAXXXXXXXXDBH0481D000001S DBH0481DXXXAXAXXXXXXXXDBH0483D000001S DBH0483DXXXAXAXXXXXXXXDBH0601D000001S DBH0601DXXXAXAXXXXXXXXDBH0603D000001S DBH0603DXXXAXAXXXXXXXX

Page 5: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Features and Benefits

SS-DBH3-D www.daikinac.com 5

Installation Daikin Packaged units are designed with an easier and faster installation in mind for both new construction and retrofit. Our packaged rooftop units are built to be a direct replacement for most rooftop units on the field without the need of a curb adapter, to be able to replace the unit in a shorter time and at a lower cost.

Cabinet Construction Daikin packaged rooftop units are made with high quality galvanized steel with a powder-paint finish to provide higher corrosion resistance.

» Easy accessibility using our tool-less filter access.

» The interior surface in the indoor air section is fully insulated to prevent sweating and thermal losses, using our foil face fiberglass insulation which also omits exposed filter fibers into the airstream.

» 1" Raised flanged edges around the supply and return offer easier installation for the duct connections.

» The full perimeter base rail is built using heavy gauge galvanized steel for a stronger structural installation, the base rails are a minimum of 3 ½” tall and include holes to allow for overhead rigging and lifting with forklifts.

» Electrical lines and can be brought through the base of the unit or through the horizontal knockout for easier installation and accessibility on the field.

Compressor High performance, low noise scroll compressors, adjust the speed to match the required total cooling and heating load for efficient part load control.

» Resiliently factory-mounted on rubber grommets for vibration isolation

» Refrigeration circuit includes both a low and high pressure transducer, high pressure safety switch and temperature sensors for the suction and discharge.

» Unit is factory charged with environmental friendly and sustainable R-410A refrigerant.

» Single stage scroll compressors.

» Compressor location outside the condenser section to avoid air bypass.

» Internal overload protection included with compressor.

Supply Fan The direct drive airfoil single width, single inlet (SWSI) Class II construction supply fan with aluminum fan blades provides efficient and quiet operation at wide ranging static pressure and air flow requirements.

» Fan wheel is continuously welded to the hub plate and end rim for long lasting reliable operation.

» Direct drive EEM motor removes the need for belts, sheaves, or bearings and its permanently lubricated motors provides low maintenance cost.

» Each fan assembly is dynamically trim balanced at the factory before shipment for quick start up and efficient operation.

» Electro mechanical integrated controls modulate the supply fan motor

» Motor with thermal overload and phase failure protection is provided for motor long lasting operation.

Daikin packaged rooftop units are built to perform, with features and options that provide lower installation and operating costs, superior indoor air quality, quiet operation and longevity.

Page 6: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Features and Benefits

6 www.daikinac.com SS-DBH3-D

Coils All units use large face area outdoor coils. These coils are constructed with seamless copper tubes, mechanically bonded into aluminum plate-type fins with full drawn collars to completely cover the tubes for high operating efficiencies.

The indoor coil section is installed in a draw through configuration to provide better dehumidification.

» Coils are factory pressure tested to ensure pressure and leak integrity.

» High and low pressure switches to be factory installed as fittings instead of brazed for easy removal and replacement.

» Copper tube / aluminum fin coils on condenser and evaporator

» 5mm Smart Coil Technology on all condenser coils for improved performance and reduced refrigerant load.

Heat Pump Heating Evaporator coil, condenser coil, compressors and refrigerant circuit are designed for heat pump operation.

» The refrigerant circuit contains a 4-way reversing valve to provide heat.

» The outdoor coil includes a thermal expansion valve to control the refrigerant flow during heat pump operation.

» Hybrid heating option is provided for auxiliary heating.

» The refrigerant system includes a pump-down cycle for durable operation.

Controls and Wiring Packaged rooftop units come equipped with a well-organized, large, easy to use weather proof internal control box with easy access, for a better user experience.

» Units are factory-wired with labeled color-coded wires and complete 24-volt electro-mechanical controls package.

» Units include single-point power entry as standard and also available with electric heat kits if selected.

» Terminal blocks are provided as standard for easier installation and field power wiring.

Filtration Unit provides a draw-through filter section as standard for better air quality and longer lasting component maintenance.

» Filters installed on the units are standard off the shelf sizes for easy replacement.

» One or two size filter per unit for lower maintenance cost and easy replacement.

» Easy and fast filter service access.

Heating Section Wide ranging of electric heat selections effectively handle most comfort heating demand from morning warm-up control to full heat.

Electric Heat ETL approved electric heat is factory assembled, installed and tested.

» Heating control is fully integrated into the unit’s control system for quick startup and reliable control.

» Durable low watt density, nickel chromium elements provide longer life.

» Fuses are provided in each branch circuit to a maximum of 48 Amps per NEC requirements.

» Single point power connection reduces installation cost.

» For operational safeties electric heat includes automatic reset, and high temperature limit safety protection and an airflow safety switch to prevent electric heat operation in the event of no airflow.

Electrical Units are completely wired and tested at the factory to provide faster commissioning and start-up.

» Wiring complies with NEC requirements and all applicable UL standards.

» For ease of use, wiring and electrical components are number coded and labeled according to the electrical diagram.

» A 120 V GFI convenience receptacle requiring independent power supply for the receptacle is optional.

» An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary overload protection, eliminates the need to pull a separate 115 V power source.

» Supply air fan, compressor, and condenser fan motor branch circuits have individual short circuit protection. Unit includes knockouts in the bottom of the main control panels for field wiring entrance.

» A single point power connection with power block is standard and a terminal board is provided for connecting low voltage control wiring.

» For better serviceability an optional non-fused disconnect switch can be installed inside the control panel and operated by an externally mounted handle to disconnect the electrical power at the unit.

Page 7: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary
Page 8: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Applications & Serviceability

8 www.daikinac.com SS-DBH3-D

ApplicationsDaikin Rooftop units are intended for comfort cooling applications in normal heating, ventilating, and air conditioning. Consult your local Daikin sales representative for applications involving operations at high ambient temperatures, high altitudes, non-cataloged voltages, or for job specific unit selections that fall outside of the range of the catalog tables.

For proper operation, units should be rigged in accordance with instructions stated on the installation manual. Fire dampers, if required, must be installed in the ductwork according to local and/or state codes. No space is allowed for these dampers in the unit.

Follow factory check, test and start procedures explicitly to achieve satisfactory start-up and operation.

Most rooftop applications take advantage of the significant energy savings provided with economizer operation. When an economizer system is used, mechanical refrigeration is typically not required below an ambient temperature of 50°F.

Serviceability Daikin packaged rooftop units are built with serviceability in mind, designed to make future maintenance and service on the unit easier and more accessible.

» Our packaged rooftop units offer a slide out blower to facilitate the access and removal of the fan.

» Filter panels on the small chassis line offer tool less access for easy maintenance.

» Independent compressor outside of the air bypass to eliminate component blockage and provide easy access.

» Labeled field connections, color coded and continuously marked wire to identify point-to-point component connections.

» All 3 - 5 ton units are designed for convertible airflow orientation to serve downflow or horizontal applications. Every unit ships prepared to convert to horizontal orientation in the field if required.

» Condenser clean out from inside-out.

» Easy access to gas valves and control panel.

Page 9: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Product Specifications

SS-DBH3-D www.daikinac.com 9

Model DBH0361D000001S DBH0363D000001S DBH0481D000001S DBH0483D000001S DBH0601D000001S DBH0603D000001SCOOLING CAPACITYTotal, BTU/h 35,000 35,000 46,500 46,500 56,500 56,500SEER / EER 14.0/11.5 14.0/11.5 14.0/11.5 14.0/11.5 14.0/11.5 14.0/11.5HEATING CAPACITY BTU/h (47°F) 34,200 34,200 45,500 45,500 56,500 56,500HSPF 8 8 8 8 8 8COP 2.34 2.34 2.34 2.34 2.34 2.34EVAPORATOR MOTOR / COIL Motor Type Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive Direct DriveExternal Static Pressure (ESP) Standard Standard Standard Standard Standard Standard Wheel Dia. X Width 12x11 12x11 12 x 11 12 x 11 12 x 11 12 x 11Indoor Nominal CFM 1170 1170 1460 1460 1790 1790RPM 1200 1200 1200 1200 1200 1200Indoor Horsepower 0.75 0.75 1.0 1.0 1.0 1.0

Filter Size (in) 14 X 20 X 2 (4) 14 X 20 X 2 (4) 14 X 20 X 2 (4) 14 X 20 X 2 (4) 14 X 20 X 2 (2)20 X 20 X 2 (2)

14 X 20 X 2 (2)20 X 20 X 2 (2)

Drain Size (NPT) ¾ ¾ ¾ ¾ ¾ ¾R-410A Refrigerant Charge (oz.) 175 175 195 195 208 208Evaporator Coil Face Area (ft²) 7.3 7.3 7.3 7.3 9.2 9.2Rows Deep/ Fins per Inch 4/16 4/16 4/16 4/16 4/16 4/16

CONDENSER FAN/COILQuantity of Condenser Fan Motors 1 1 1 1 1 1

RPM (High/Low stage) 810 810 1075 1075 1075 1075Outdoor Horsepower 0.17 0.17 0.25 0.25 0.33 0.33Fan Diameter/ # Fan Blades 22 / 3 22 / 3 22 / 4 22 / 4 22 / 4 22 / 4Face Area (ft²) 12.7 12.7 17.3 17.3 19.0 19.0Rows Deep / Fins per Inch 2/16 2/16 2/16 2/16 2/16 2/16

COMPRESSOR (ALL SINGLE-STAGE)Quantity / Type / Stages 1 / Scroll / 1 1 / Scroll / 1 1 / Scroll / 1 1 / Scroll / 1 1 / Scroll / 1 1 / Scroll / 1Compressor RLA / LRA 16.7 / 79.0 10.4 / 73.0 19.9 / 109.0 13.1 / 83.1 25.0 / 134.0 15.9 / 110.0ELECTRICAL DATA Voltage-Phase-Frequency 208/230-1-60 208/230-3-60 208/230-1-60 208/230-3-60 208/230-1-60 208/230-3-60Indoor Blower FLA 5.7 5.7 6.9 6.9 6.9 6.9Max External Static (In. W.C.) 0.8 0.8 0.8 0.8 0.8 0.8Outdoor Fan FLA 0.95 0.95 1.4 1.4 2.3 2.3Min. Circuit Ampacity¹ 27.5 / 27.5 19.7 / 19.7 33.1 / 33.1 24.7 / 24.7 40.4 / 40.4 29.1 / 29.1Max. Overcurrent Protection (A)² 40 / 40 30 / 30 50 / 50 35 /35 60 / 60 40 / 40

Power Supply Conduit Hole Dia. (in) 1.125 1.125 1.125 1.125 1.125 1.125

Low-Voltage Conduit Hole Dia. (in) 0.5 0.5 0.5 0.5 0.5 0.5

OPERATING WEIGHT (LBS.)Operating Weight (lbs) 560 560 589 589 632 632SHIPPING WEIGHT (LBS.)Ship Weight (lbs) 605 605 629 629 672 672¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed.

DBH036 / 48 / 60

MODEL CAPACITY EER SEERDBH0361D 35,000 11.5 14DBH0481D 46,500 11.5 14DBH0601D 56,500 11.5 14DBH0363D 35,000 11.5 14DBH0483D 46,500 11.5 14DBH0603D 56,500 11.5 14

AHRI Ratings Sound DataModel

Outdoor sound (db) at 60 HzA-Weighted 63 125 250 500 1000 2000 4000 8000

036 75 78.5 85.4 74.4 71.8 69.1 65.8 60.9 59.2

048 73 82.5 78.1 71.6 69.5 68.0 66.1 59.5 58.6

060 76 84.4 80.5 76.2 72.9 70.9 67.4 63.8 63.1Notes:

1 Outdoor sound data is measued in accordance with AHRI standard 270. 2 Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure depends on specific environment factors which normally do not match individual applications. Sound power values are independent of the environment and therefore more accurate.3 A-weighted sound ratings filter out high and very low frequencies, to better approximate the response of "average" human ear. A-weighted measurements for Daikin units are taken in accordance with AHRI standard 270.

Page 10: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

10 www.daikinac.com SS-DBH3-D

DBH036*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

900

Capa

city

35,1

5935

,662

36,7

26-

34,8

4035

,343

36,4

07-

33,9

1034

,413

35,4

77-

32,3

1132

,813

33,8

77-

30,3

5530

,858

31,9

22-

28,5

7129

,073

30,1

37-

S/T

0.50

0.42

0.28

-0.

500.

430.

29-

0.53

0.45

0.32

-1.

000.

470.

34-

1.00

0.49

0.36

-1.

000.

540.

41-

Evap

dT

22.5

820

.65

17.0

5-

22.5

220

.60

16.9

9-

22.8

020

.87

17.2

6-

22.5

020

.58

16.9

7-

22.2

520

.32

16.7

2-

23.4

521

.53

17.9

2-

Pr S

uc12

512

713

0-

133

135

138

-14

014

114

5-

146

147

150

-15

115

315

6-

158

160

163

-

Pr D

is26

226

326

5-

304

305

307

-34

834

935

1-

395

396

398

-44

644

744

9-

500

501

503

-

Tota

lPow

er2,

094

2,09

22,

088

-2,

371

2,36

92,

364

-2,

680

2,67

82,

673

-3,

015

3,01

23,

008

-3,

388

3,38

63,

381

-3,

827

3,82

43,

820

-

1230

Capa

city

36,0

7636

,579

37,6

43-

35,7

5836

,260

37,3

24-

34,8

2835

,331

36,3

94-

33,2

2833

,731

34,7

95-

31,2

7331

,776

32,8

39-

29,4

8829

,991

31,0

55-

S/T

0.67

0.59

0.45

-0.

670.

600.

46-

1.00

0.62

0.49

-1.

000.

640.

51-

1.00

0.66

0.53

-1.

001.

000.

58-

Evap

dT

19.6

917

.76

14.1

6-

19.6

417

.71

14.1

1-

19.9

117

.98

14.3

8-

19.6

217

.69

14.0

9-

19.3

617

.43

13.8

3-

20.5

718

.64

15.0

4-

Pr S

uc12

913

113

4-

137

139

142

-14

414

514

9-

150

151

154

-15

515

716

0-

162

164

167

-

Pr D

is26

726

827

0-

309

310

312

-35

335

435

6-

400

401

403

-45

145

245

4-

505

506

508

-

Tota

lPow

er2,

130

2,12

82,

123

-2,

407

2,40

52,

400

-2,

716

2,71

42,

709

-3,

050

3,04

83,

043

-3,

424

3,42

23,

417

-3,

862

3,86

03,

855

-

1350

Capa

city

36,5

0637

,009

38,0

72-

36,1

8736

,690

37,7

54-

35,2

5735

,760

36,8

24-

33,6

5734

,160

35,2

24-

31,7

0232

,205

33,2

69-

29,9

1730

,420

31,4

84-

S/T

0.70

0.62

0.48

-0.

700.

630.

49-

1.00

0.65

0.51

-1.

000.

670.

53-

1.00

0.69

0.56

-1.

001.

000.

61-

Evap

dT

18.9

216

.99

13.3

8-

18.8

616

.93

13.3

3-

19.1

317

.20

13.6

0-

18.8

416

.91

13.3

1-

18.5

916

.66

13.0

5-

19.7

917

.86

14.2

6-

Pr S

uc13

113

213

6-

139

140

143

-14

514

715

0-

151

153

156

-15

715

816

2-

164

165

169

-

Pr D

is26

927

027

2-

311

312

314

-35

535

635

8-

402

403

405

-45

345

445

6-

507

508

510

-

Tota

lPow

er2,

140

2,13

72,

133

-2,

416

2,41

42,

409

-2,

725

2,72

32,

718

-3,

060

3,05

83,

053

-3,

433

3,43

13,

426

-3,

872

3,87

03,

865

-

75

900

Capa

city

35,1

8035

,683

36,7

4638

,371

34,8

6135

,364

36,4

2838

,052

33,9

3134

,434

35,4

9837

,123

32,3

3132

,834

33,8

9835

,523

30,3

7630

,879

31,9

4333

,568

28,5

9129

,094

30,1

5831

,783

S/T

0.63

0.55

0.41

0.27

1.00

0.56

0.42

0.28

1.00

0.58

0.45

0.30

1.00

0.60

0.46

0.32

1.00

0.62

0.49

0.34

1.00

1.00

0.54

0.40

Evap

dT

26.8

224

.89

21.2

917

.56

26.7

724

.84

21.2

417

.50

27.0

425

.11

21.5

117

.77

26.7

524

.82

21.2

217

.48

26.4

924

.56

20.9

617

.23

27.7

025

.77

22.1

718

.43

Pr S

uc12

512

713

013

613

313

513

814

314

014

214

515

014

614

715

115

615

115

315

616

215

816

016

316

9

Pr D

is26

226

426

527

030

430

530

731

234

834

935

135

639

539

639

840

344

644

744

945

450

050

150

350

8

Tota

lPow

er2,

093

2,09

02,

086

2,10

72,

369

2,36

72,

363

2,38

42,

678

2,67

62,

672

2,69

33,

013

3,01

13,

006

3,02

73,

386

3,38

43,

380

3,40

13,

825

3,82

33,

818

3,83

9

1230

Capa

city

36,0

9736

,600

37,6

6439

,289

35,7

7836

,281

37,3

4538

,970

34,8

4835

,351

36,4

1538

,040

33,2

4933

,752

34,8

1536

,440

31,2

9431

,796

32,8

6034

,485

29,5

0930

,012

31,0

7532

,700

S/T

0.80

0.72

0.58

0.44

1.00

0.73

0.59

0.45

1.00

0.75

0.62

0.47

1.00

0.77

0.63

0.49

1.00

1.00

0.66

0.51

1.00

1.00

0.71

0.57

Evap

dT

23.9

322

.01

18.4

014

.67

23.8

821

.95

18.3

514

.62

24.1

522

.22

18.6

214

.89

23.8

621

.93

18.3

314

.60

23.6

021

.67

18.0

714

.34

24.8

122

.88

19.2

815

.55

Pr S

uc12

913

113

414

013

713

914

214

714

414

514

915

415

015

115

416

015

515

716

016

516

216

416

717

3

Pr D

is26

826

927

127

530

931

031

231

735

335

435

636

140

040

140

340

845

145

245

445

950

550

750

851

3

Tota

lPow

er2,

128

2,12

62,

121

2,14

22,

405

2,40

32,

398

2,41

92,

714

2,71

22,

707

2,72

83,

048

3,04

63,

042

3,06

33,

422

3,42

03,

415

3,43

63,

860

3,85

83,

853

3,87

5

1350

Capa

city

36,5

2637

,029

38,0

9339

,718

36,2

0836

,711

37,7

7439

,399

35,2

7835

,781

36,8

4538

,469

33,6

7834

,181

35,2

4536

,870

31,7

2332

,226

33,2

9034

,914

29,9

3830

,441

31,5

0533

,130

S/T

0.82

0.75

0.61

0.47

1.00

0.75

0.62

0.48

1.00

0.78

0.64

0.50

1.00

0.80

0.66

0.52

1.00

1.00

0.69

0.54

1.00

1.00

0.74

0.59

Evap

dT

23.1

621

.23

17.6

313

.89

23.1

021

.18

17.5

713

.84

23.3

821

.45

17.8

414

.11

23.0

821

.16

17.5

513

.82

22.8

320

.90

17.3

013

.56

24.0

322

.11

18.5

014

.77

Pr S

uc13

113

313

614

113

914

014

414

914

514

715

015

615

115

315

616

115

715

816

216

716

416

516

917

4

Pr D

is26

927

027

227

731

131

231

431

935

535

635

836

240

240

340

541

045

345

445

646

150

750

851

051

5

Tota

lPow

er2,

138

2,13

62,

131

2,15

22,

415

2,41

22,

408

2,42

92,

724

2,72

12,

717

2,73

83,

058

3,05

63,

051

3,07

23,

432

3,42

93,

425

3,44

63,

870

3,86

83,

863

3,88

4

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 11: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

SS-DBH3-D www.daikinac.com 11

DBH036*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

900

Capa

city

35,3

6435

,867

36,9

3138

,556

35,0

4535

,548

36,6

1238

,237

34,1

1634

,618

35,6

8237

,307

32,5

1633

,019

34,0

8235

,707

30,5

6131

,064

32,1

2733

,752

28,7

7629

,279

30,3

4231

,967

S/T

1.00

0.68

0.54

0.40

1.00

0.68

0.55

0.40

1.00

0.71

0.57

0.43

1.00

1.00

0.59

0.45

1.00

1.00

0.61

0.47

1.00

1.00

0.66

0.52

Evap

dT

31.0

929

.16

25.5

621

.83

31.0

429

.11

25.5

121

.77

31.3

129

.38

25.7

822

.04

31.0

229

.09

25.4

921

.75

30.7

628

.83

25.2

321

.50

31.9

730

.04

26.4

422

.70

Pr S

uc12

612

813

113

613

413

513

914

414

114

214

515

114

614

815

115

615

215

315

716

215

916

116

416

9

Pr D

is26

326

426

627

030

530

630

831

234

835

035

135

639

639

739

940

344

744

845

045

450

150

250

450

8

Tota

lPow

er2,

094

2,09

22,

087

2,10

82,

371

2,36

92,

364

2,38

52,

680

2,67

82,

673

2,69

43,

014

3,01

23,

007

3,02

93,

388

3,38

63,

381

3,40

23,

826

3,82

43,

819

3,84

0

1230

Capa

city

36,2

8136

,784

37,8

4839

,473

35,9

6336

,466

37,5

2939

,154

35,0

3335

,536

36,6

0038

,224

33,4

3333

,936

35,0

0036

,625

31,4

7831

,981

33,0

4534

,670

29,6

9330

,196

31,2

6032

,885

S/T

1.00

0.85

0.71

0.57

1.00

0.85

0.72

0.57

1.00

1.00

0.74

0.60

1.00

1.00

0.76

0.62

1.00

1.00

0.78

0.64

1.00

1.00

1.00

0.69

Evap

dT

28.2

026

.28

22.6

718

.94

28.1

526

.22

22.6

218

.89

28.4

226

.49

22.8

919

.16

28.1

326

.20

22.6

018

.87

27.8

725

.95

22.3

418

.61

29.0

827

.15

23.5

519

.82

Pr S

uc13

013

113

514

013

813

914

214

814

414

614

915

515

015

215

516

015

615

716

116

616

316

416

817

3

Pr D

is26

826

927

127

631

031

131

331

735

435

535

736

140

140

240

440

845

245

345

545

950

650

750

951

4

Tota

lPow

er2,

130

2,12

82,

123

2,14

42,

407

2,40

42,

400

2,42

12,

715

2,71

32,

709

2,73

03,

050

3,04

83,

043

3,06

43,

423

3,42

13,

417

3,43

83,

862

3,86

03,

855

3,87

6

1350

Capa

city

36,7

1137

,214

38,2

7839

,902

36,3

9236

,895

37,9

5939

,584

35,4

6235

,965

37,0

2938

,654

33,8

6334

,365

35,4

2937

,054

31,9

0732

,410

33,4

7435

,099

30,1

2330

,626

31,6

8933

,314

S/T

1.00

0.87

0.74

0.59

1.00

0.88

0.74

0.60

1.00

1.00

0.77

0.63

1.00

1.00

0.79

0.65

1.00

1.00

0.81

0.67

1.00

1.00

1.00

0.72

Evap

dT

27.4

325

.50

21.9

018

.16

27.3

725

.45

21.8

418

.11

27.6

525

.72

22.1

118

.38

27.3

525

.43

21.8

218

.09

27.1

025

.17

21.5

717

.83

28.3

026

.38

22.7

719

.04

Pr S

uc13

113

313

614

213

914

114

414

914

614

815

115

615

215

315

716

215

715

916

216

816

416

616

917

5

Pr D

is27

027

127

327

731

231

331

531

935

535

635

836

340

340

440

641

045

345

545

646

150

850

951

151

5

Tota

lPow

er2,

139

2,13

72,

132

2,15

32,

416

2,41

42,

409

2,43

02,

725

2,72

32,

718

2,73

93,

059

3,05

73,

053

3,07

43,

433

3,43

13,

426

3,44

73,

871

3,86

93,

864

3,88

6

85

900

Capa

city

35,9

6436

,467

37,5

3139

,156

35,6

4536

,148

37,2

1238

,837

34,7

1635

,218

36,2

8237

,907

33,1

1633

,619

34,6

8236

,307

31,1

6131

,664

32,7

2734

,352

29,3

7629

,879

30,9

4232

,567

S/T

1.00

0.78

0.64

0.50

1.00

1.00

0.65

0.50

1.00

1.00

0.67

0.53

1.00

1.00

0.69

0.55

1.00

1.00

1.00

0.57

1.00

1.00

1.00

0.62

Evap

dT

34.8

832

.95

29.3

525

.61

34.8

232

.89

29.2

925

.56

35.0

933

.17

29.5

625

.83

34.8

032

.87

29.2

725

.54

34.5

532

.62

29.0

125

.28

35.7

533

.82

30.2

226

.49

Pr S

uc12

812

913

313

813

613

714

014

614

214

414

715

314

815

015

315

815

415

515

916

416

116

216

617

1

Pr D

is26

426

526

727

230

630

730

931

435

035

135

335

739

739

840

040

544

844

945

145

550

250

350

551

0

Tota

lPow

er2,

099

2,09

72,

092

2,11

42,

376

2,37

42,

369

2,39

02,

685

2,68

32,

678

2,69

93,

020

3,01

73,

013

3,03

43,

393

3,39

13,

386

3,40

73,

832

3,82

93,

825

3,84

6

1230

Capa

city

36,8

8137

,384

38,4

4840

,073

36,5

6337

,066

38,1

2939

,754

35,6

3336

,136

37,2

0038

,824

34,0

3334

,536

35,6

0037

,225

32,0

7832

,581

33,6

4535

,270

30,2

9330

,796

31,8

6033

,485

S/T

1.00

0.95

0.81

0.67

1.00

1.00

0.82

0.67

1.00

1.00

0.84

0.70

1.00

1.00

0.86

0.72

1.00

1.00

1.00

0.74

1.00

01.

000

1.00

00.

792

Evap

dT

31.9

930

.06

26.4

622

.73

31.9

430

.01

26.4

122

.68

32.2

130

.28

26.6

822

.95

31.9

229

.99

26.3

922

.66

31.6

629

.73

26.1

322

.40

32.8

730

.94

27.3

423

.61

Pr S

uc13

213

313

714

214

014

114

415

014

614

815

115

715

215

415

716

215

815

916

316

816

516

617

017

5

Pr D

is26

927

027

227

731

131

231

431

935

535

635

836

340

240

340

541

045

345

445

646

150

750

851

051

5

Tota

lPow

er2,

135

2,13

32,

128

2,14

92,

412

2,41

02,

405

2,42

62,

721

2,71

92,

714

2,73

53,

055

3,05

33,

048

3,06

93,

429

3,42

73,

422

3,44

33,

867

3,86

53,

860

3,88

1

1350

Capa

city

37,3

1137

,814

38,8

7840

,502

36,9

9237

,495

38,5

5940

,184

36,0

6236

,565

37,6

2939

,254

34,4

6334

,965

36,0

2937

,654

32,5

0733

,010

34,0

7435

,699

30,7

2331

,225

32,2

8933

,914

S/T

1.00

0.98

0.84

0.70

1.00

1.00

0.85

0.70

1.00

1.00

0.87

0.73

1.00

1.00

1.00

0.75

1.00

1.00

1.00

0.77

1.00

1.00

1.00

0.82

Evap

dT

31.2

129

.29

25.6

821

.95

31.1

629

.23

25.6

321

.90

31.4

329

.50

25.9

022

.17

31.1

429

.21

25.6

121

.88

30.8

828

.95

25.3

521

.62

32.0

930

.16

26.5

622

.83

Pr S

uc13

313

513

814

414

114

314

615

114

815

015

315

815

415

515

916

415

916

116

417

016

616

817

117

7

Pr D

is27

127

227

427

931

331

431

632

035

735

836

036

440

440

540

741

145

545

645

846

250

951

051

251

7

Tota

lPow

er2,

145

2,14

22,

138

2,15

92,

421

2,41

92,

414

2,43

62,

730

2,72

82,

723

2,74

53,

065

3,06

33,

058

3,07

93,

438

3,43

63,

431

3,45

33,

877

3,87

43,

870

3,89

1

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s A

HRI

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

er

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 12: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

12 www.daikinac.com SS-DBH3-D

DBH048*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1200

Capa

city

46,8

3947

,507

48,9

20-

46,4

1547

,084

48,4

97-

45,1

8045

,848

47,2

61-

43,0

5543

,723

45,1

36-

40,4

5741

,125

42,5

39-

38,0

8638

,754

40,1

67-

S/T

0.52

0.45

0.31

-0.

530.

450.

32-

0.55

0.48

0.34

-0.

570.

500.

36-

1.00

0.52

0.38

-1.

000.

570.

43-

Evap

dT

22.1

420

.21

16.6

1-

22.0

820

.16

16.5

5-

22.3

620

.43

16.8

2-

22.0

620

.14

16.5

3-

21.8

119

.88

16.2

8-

23.0

121

.09

17.4

8-

Pr S

uc12

212

312

6-

129

131

134

-13

613

714

1-

141

143

146

-14

714

815

2-

154

155

158

-

Pr D

is25

325

525

6-

294

295

297

-33

633

733

9-

381

383

384

-43

043

243

3-

483

484

486

-

Tota

lPow

er2,

835

2,83

22,

826

-3,

189

3,18

63,

180

-3,

585

3,58

23,

576

-4,

013

4,01

04,

004

-4,

491

4,48

84,

482

-5,

052

5,04

95,

043

-

1570

Capa

city

47,9

3048

,598

50,0

11-

47,5

0648

,175

49,5

88-

46,2

7146

,939

48,3

52-

44,1

4644

,814

46,2

27-

41,5

4842

,216

43,6

30-

39,1

7739

,845

41,2

58-

S/T

0.66

0.58

0.45

-0.

670.

590.

46-

0.69

0.62

0.48

-1.

000.

640.

50-

1.00

0.66

0.52

-1.

000.

710.

57-

Evap

dT

19.6

917

.76

14.1

6-

19.6

417

.71

14.1

1-

19.9

117

.98

14.3

8-

19.6

217

.69

14.0

9-

19.3

617

.43

13.8

3-

20.5

718

.64

15.0

4-

Pr S

uc12

512

713

0-

133

134

137

-13

914

114

4-

145

146

149

-15

015

215

5-

157

159

162

-

Pr D

is25

825

926

1-

298

299

301

-34

034

134

3-

386

387

389

-43

543

643

8-

487

488

490

-

Tota

lPow

er2,

873

2,87

12,

865

-3,

228

3,22

53,

219

-3,

623

3,62

03,

614

-4,

051

4,04

84,

042

-4,

529

4,52

74,

521

-5,

090

5,08

85,

082

-

1800

Capa

city

48,8

1949

,487

50,9

01-

48,3

9649

,064

50,4

77-

47,1

6047

,828

49,2

42-

45,0

3545

,703

47,1

16-

42,4

3743

,106

44,5

19-

40,0

6640

,734

42,1

47-

S/T

0.70

0.62

0.49

-0.

700.

630.

49-

0.73

0.65

0.52

-1.

000.

670.

54-

1.00

0.69

0.56

-1.

000.

750.

61-

Evap

dT

18.5

616

.63

13.0

3-

18.5

016

.57

12.9

7-

18.7

716

.85

13.2

4-

18.4

816

.55

12.9

5-

18.2

316

.30

12.6

9-

19.4

317

.50

13.9

0-

Pr S

uc12

812

913

2-

135

137

140

-14

214

314

6-

147

149

152

-15

315

415

7-

159

161

164

-

Pr D

is26

026

126

3-

300

302

303

-34

334

434

6-

388

389

391

-43

743

844

0-

490

491

492

-

Tota

lPow

er2,

891

2,88

92,

882

-3,

246

3,24

33,

237

-3,

641

3,63

83,

632

-4,

069

4,06

64,

060

-4,

547

4,54

54,

538

-5,

108

5,10

65,

099

-

75

1200

Capa

city

46,8

6647

,535

48,9

4851

,107

46,4

4347

,111

48,5

2450

,683

45,2

0845

,876

47,2

8949

,448

43,0

8243

,750

45,1

6447

,322

40,4

8541

,153

42,5

6644

,725

38,1

1338

,782

40,1

9542

,354

S/T

0.65

0.57

0.44

0.30

0.66

0.58

0.45

0.30

1.00

0.61

0.47

0.33

1.00

0.62

0.49

0.35

1.00

0.65

0.51

0.37

1.00

1.00

0.56

0.42

Evap

dT

26.3

824

.45

20.8

517

.12

26.3

324

.40

20.7

917

.06

26.6

024

.67

21.0

717

.33

26.3

124

.38

20.7

817

.04

26.0

524

.12

20.5

216

.79

27.2

625

.33

21.7

317

.99

Pr S

uc12

212

312

713

212

913

113

413

913

613

714

114

614

114

314

615

114

714

815

215

715

415

515

816

4

Pr D

is25

425

525

726

129

429

529

730

133

633

733

934

438

238

338

538

943

143

243

443

848

348

448

649

0

Tota

lPow

er2,

833

2,83

02,

824

2,85

13,

187

3,18

43,

178

3,20

53,

582

3,58

03,

574

3,60

14,

010

4,00

84,

002

4,02

94,

489

4,48

64,

480

4,50

75,

050

5,04

75,

041

5,06

8

1570

Capa

city

47,9

5748

,626

50,0

3952

,198

47,5

3448

,202

49,6

1551

,774

46,2

9946

,967

48,3

8050

,539

44,1

7344

,841

46,2

5548

,413

41,5

7642

,244

43,6

5745

,816

39,2

0439

,873

41,2

8643

,445

S/T

0.79

0.71

0.58

0.44

0.79

0.72

0.58

0.44

1.00

0.74

0.61

0.47

1.00

0.76

0.63

0.49

1.00

0.79

0.65

0.51

1.00

1.00

0.70

0.56

Evap

dT

23.9

322

.01

18.4

014

.67

23.8

821

.95

18.3

514

.62

24.1

522

.22

18.6

214

.89

23.8

621

.93

18.3

314

.60

23.6

021

.67

18.0

714

.34

24.8

122

.88

19.2

815

.55

Pr S

uc12

512

713

013

513

313

413

714

313

914

114

414

914

514

614

915

515

015

215

516

015

715

916

216

7

Pr D

is25

825

926

126

529

829

930

130

634

034

234

334

838

638

738

939

343

543

643

844

248

748

849

049

5

Tota

lPow

er2,

871

2,86

82,

862

2,88

93,

225

3,22

33,

217

3,24

43,

621

3,61

83,

612

3,63

94,

049

4,04

64,

040

4,06

74,

527

4,52

44,

518

4,54

55,

088

5,08

55,

079

5,10

6

1800

Capa

city

48,8

4749

,515

50,9

2853

,087

48,4

2349

,091

50,5

0552

,663

47,1

8847

,856

49,2

6951

,428

45,0

6245

,731

47,1

4449

,303

42,4

6543

,133

44,5

4646

,705

40,0

9440

,762

42,1

7544

,334

S/T

0.83

0.75

0.62

0.47

1.00

0.76

0.62

0.48

1.00

0.78

0.65

0.50

1.00

0.80

0.67

0.52

1.00

0.82

0.69

0.55

1.00

1.00

0.74

0.60

Evap

dT

22.8

020

.87

17.2

713

.53

22.7

420

.82

17.2

113

.48

23.0

221

.09

17.4

813

.75

22.7

220

.80

17.1

913

.46

22.4

720

.54

16.9

413

.20

23.6

721

.75

18.1

414

.41

Pr S

uc12

812

913

213

713

513

714

014

514

214

314

615

214

714

915

215

715

315

415

716

315

916

116

416

9

Pr D

is26

026

126

326

830

130

230

430

834

334

434

635

038

839

039

139

643

743

944

044

549

049

149

349

7

Tota

lPow

er2,

889

2,88

62,

880

2,90

73,

243

3,24

13,

234

3,26

23,

639

3,63

63,

630

3,65

74,

067

4,06

44,

058

4,08

54,

545

4,54

24,

536

4,56

35,

106

5,10

35,

097

5,12

4

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 13: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

SS-DBH3-D www.daikinac.com 13

DBH048*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1200

Capa

city

47,1

1247

,780

49,1

9351

,352

46,6

8847

,356

48,7

6950

,928

45,4

5346

,121

47,5

3449

,693

43,3

2743

,995

45,4

0947

,567

40,7

3041

,398

42,8

1144

,970

38,3

5839

,027

40,4

4042

,599

S/T

0.77

0.70

0.56

0.42

1.00

0.70

0.57

0.43

1.00

0.73

0.59

0.45

1.00

0.75

0.61

0.47

1.00

1.00

0.64

0.49

1.00

1.00

0.69

0.55

Evap

dT

30.6

528

.72

25.1

221

.39

30.6

028

.67

25.0

721

.33

30.8

728

.94

25.3

421

.60

30.5

828

.65

25.0

521

.31

30.3

228

.39

24.7

921

.06

31.5

329

.60

26.0

022

.26

Pr S

uc12

212

412

713

213

013

113

514

013

613

814

114

614

214

414

715

214

714

915

215

715

415

615

916

4

Pr D

is25

425

525

726

129

429

629

730

233

733

834

034

438

238

338

538

943

143

243

443

948

448

548

649

1

Tota

lPow

er2,

834

2,83

22,

826

2,85

33,

189

3,18

63,

180

3,20

73,

584

3,58

13,

575

3,60

24,

012

4,00

94,

003

4,03

04,

490

4,48

84,

482

4,50

95,

051

5,04

95,

043

5,07

0

1570

Capa

city

48,2

0348

,871

50,2

8452

,443

47,7

7948

,447

49,8

6052

,019

46,5

4447

,212

48,6

2550

,784

44,4

1845

,086

46,5

0048

,658

41,8

2142

,489

43,9

0246

,061

39,4

4940

,118

41,5

3143

,690

S/T

1.00

0.84

0.70

0.56

1.00

0.84

0.71

0.57

1.00

0.87

0.73

0.59

1.00

1.00

0.75

0.61

1.00

1.00

0.78

0.63

1.00

1.00

0.83

0.68

Evap

dT

28.2

026

.28

22.6

718

.94

28.1

526

.22

22.6

218

.89

28.4

226

.49

22.8

919

.16

28.1

326

.20

22.6

018

.87

27.8

725

.95

22.3

418

.61

29.0

827

.15

23.5

519

.82

Pr S

uc12

612

713

013

613

313

513

814

314

014

114

415

014

514

715

015

515

115

215

516

115

815

916

216

8

Pr D

is25

825

926

126

629

930

030

230

634

134

234

434

838

638

838

939

443

543

743

844

348

848

949

149

5

Tota

lPow

er2,

873

2,87

02,

864

2,89

13,

227

3,22

53,

218

3,24

63,

623

3,62

03,

614

3,64

14,

051

4,04

84,

042

4,06

94,

529

4,52

64,

520

4,54

75,

090

5,08

75,

081

5,10

8

1800

Capa

city

49,0

9249

,760

51,1

7353

,332

48,6

6849

,336

50,7

5052

,908

47,4

3348

,101

49,5

1451

,673

45,3

0845

,976

47,3

8949

,548

42,7

1043

,378

44,7

9146

,950

40,3

3941

,007

42,4

2044

,579

S/T

1.00

0.87

0.74

0.60

1.00

0.88

0.75

0.60

1.00

0.91

0.77

0.63

1.00

1.00

0.79

0.65

1.00

1.00

0.81

0.67

1.00

1.00

0.86

0.72

Evap

dT

27.0

725

.14

21.5

417

.81

27.0

125

.09

21.4

817

.75

27.2

925

.36

21.7

518

.02

26.9

925

.07

21.4

617

.73

26.7

424

.81

21.2

117

.47

27.9

426

.02

22.4

118

.68

Pr S

uc12

813

013

313

813

613

714

014

614

214

414

715

214

814

915

215

815

315

515

816

316

016

216

517

0

Pr D

is26

126

226

426

830

130

230

430

934

334

534

635

138

939

039

239

643

843

944

144

549

049

149

349

8

Tota

lPow

er2,

891

2,88

82,

882

2,90

93,

245

3,24

23,

236

3,26

33,

641

3,63

83,

632

3,65

94,

069

4,06

64,

060

4,08

74,

547

4,54

44,

538

4,56

55,

108

5,10

55,

099

5,12

6

85

1200

Capa

city

47,9

0948

,577

49,9

9052

,149

47,4

8548

,153

49,5

6751

,725

46,2

5046

,918

48,3

3150

,490

44,1

2444

,793

46,2

0648

,365

41,5

2742

,195

43,6

0845

,767

39,1

5639

,824

41,2

3743

,396

S/T

1.00

0.80

0.66

0.52

1.00

0.81

0.67

0.53

1.00

1.00

0.70

0.55

1.00

1.00

0.71

0.57

1.00

1.00

0.74

0.59

1.00

1.00

1.00

0.65

Evap

dT

34.4

432

.51

28.9

025

.17

34.3

832

.45

28.8

525

.12

34.6

532

.73

29.1

225

.39

34.3

632

.43

28.8

325

.10

34.1

132

.18

28.5

724

.84

35.3

133

.38

29.7

826

.05

Pr S

uc12

412

612

913

413

213

313

614

213

814

014

314

814

414

514

915

414

915

115

415

915

615

816

116

6

Pr D

is25

525

625

826

329

629

729

930

333

833

934

134

538

338

438

639

143

243

343

544

048

548

648

849

2

Tota

lPow

er2,

841

2,83

82,

832

2,85

93,

196

3,19

33,

187

3,21

43,

591

3,58

83,

582

3,60

94,

019

4,01

64,

010

4,03

74,

497

4,49

44,

488

4,51

55,

058

5,05

55,

049

5,07

6

1570

Capa

city

49,0

0049

,668

51,0

8153

,240

48,5

7649

,244

50,6

5852

,816

47,3

4148

,009

49,4

2251

,581

45,2

1545

,884

47,2

9749

,456

42,6

1843

,286

44,6

9946

,858

40,2

4740

,915

42,3

2844

,487

S/T

1.00

0.94

0.80

0.66

1.00

1.00

0.81

0.67

1.00

1.00

0.83

0.69

1.00

1.00

0.85

0.71

1.00

1.00

0.88

0.73

1.00

01.

000

1.00

00.

785

Evap

dT

31.9

930

.06

26.4

622

.73

31.9

430

.01

26.4

122

.68

32.2

130

.28

26.6

822

.95

31.9

229

.99

26.3

922

.66

31.6

629

.73

26.1

322

.40

32.8

730

.94

27.3

423

.61

Pr S

uc12

812

913

213

713

513

714

014

514

214

314

615

214

714

915

215

715

315

415

716

315

916

116

416

9

Pr D

is26

026

126

226

730

030

130

330

734

234

334

535

038

838

939

139

543

743

844

044

448

949

049

249

6

Tota

lPow

er2,

880

2,87

72,

871

2,89

83,

234

3,23

13,

225

3,25

23,

630

3,62

73,

621

3,64

84,

058

4,05

54,

049

4,07

64,

536

4,53

34,

527

4,55

45,

097

5,09

45,

088

5,11

5

1800

Capa

city

49,8

8950

,557

51,9

7054

,129

49,4

6550

,134

51,5

4753

,706

48,2

3048

,898

50,3

1152

,470

46,1

0546

,773

48,1

8650

,345

43,5

0744

,175

45,5

8947

,747

41,1

3641

,804

43,2

1745

,376

S/T

1.00

0.97

0.84

0.70

1.00

1.00

0.85

0.70

1.00

1.00

0.87

0.73

1.00

1.00

0.89

0.75

1.00

1.00

1.00

0.77

1.00

1.00

1.00

0.82

Evap

dT

30.8

528

.93

25.3

221

.59

30.8

028

.87

25.2

721

.54

31.0

729

.14

25.5

421

.81

30.7

828

.85

25.2

521

.52

30.5

228

.60

24.9

921

.26

31.7

329

.80

26.2

022

.47

Pr S

uc13

013

113

514

013

713

914

214

714

414

614

915

415

015

115

416

015

515

716

016

516

216

316

717

2

Pr D

is26

226

326

526

930

230

330

531

034

534

634

835

239

039

139

339

743

944

044

244

749

149

349

449

9

Tota

lPow

er2,

898

2,89

52,

889

2,91

63,

252

3,24

93,

243

3,27

03,

647

3,64

53,

639

3,66

64,

075

4,07

34,

067

4,09

44,

554

4,55

14,

545

4,57

25,

115

5,11

25,

106

5,13

3

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s A

HRI

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

er

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 14: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

14 www.daikinac.com SS-DBH3-D

DBH60*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

70

1500

Capa

city

57,1

4257

,954

59,6

71-

56,6

2857

,439

59,1

57-

55,1

2755

,938

57,6

56-

52,5

4453

,356

55,0

73-

49,3

8850

,200

51,9

17-

46,5

0747

,319

49,0

36-

S/T

0.55

0.48

0.35

-0.

560.

490.

35-

0.59

0.51

0.38

-0.

600.

530.

40-

0.63

0.55

0.42

-1.

000.

600.

47-

Evap

dT

21.5

619

.63

16.0

3-

21.5

119

.58

15.9

8-

21.7

819

.85

16.2

5-

21.4

919

.56

15.9

6-

21.2

319

.30

15.7

0-

22.4

420

.51

16.9

1-

Pr S

uc11

812

012

3-

125

127

130

-13

213

313

6-

137

138

141

-14

214

414

7-

149

150

153

-

Pr D

is25

125

225

4-

291

292

294

-33

333

433

6-

378

379

381

-42

642

742

9-

478

479

481

-

Tota

lPow

er3,

507

3,50

33,

496

-3,

922

3,91

93,

912

-4,

387

4,38

34,

376

-4,

889

4,88

54,

878

-5,

450

5,44

75,

440

-6,

108

6,10

56,

098

-

1850

Capa

city

58,2

3759

,049

60,7

66-

57,7

2358

,535

60,2

52-

56,2

2257

,034

58,7

51-

53,6

3954

,451

56,1

68-

50,4

8351

,295

53,0

12-

47,6

0248

,414

50,1

31-

S/T

0.66

0.58

0.45

-0.

660.

590.

45-

0.69

0.61

0.48

-0.

710.

630.

50-

1.00

0.65

0.52

-1.

000.

700.

57-

Evap

dT

19.6

917

.76

14.1

6-

19.6

417

.71

14.1

1-

19.9

117

.98

14.3

8-

19.6

217

.69

14.0

9-

19.3

617

.43

13.8

3-

20.5

718

.64

15.0

4-

Pr S

uc12

112

212

5-

128

129

132

-13

413

613

9-

140

141

144

-14

514

614

9-

151

153

156

-

Pr D

is25

525

625

8-

295

296

297

-33

633

733

9-

381

382

384

-43

043

143

3-

481

483

484

-

Tota

lPow

er3,

541

3,53

83,

531

-3,

957

3,95

43,

947

-4,

421

4,41

84,

411

-4,

923

4,92

04,

913

-5,

485

5,48

15,

474

-6,

143

6,14

06,

132

-

2250

Capa

city

59,9

2060

,732

62,4

49-

59,4

0560

,217

61,9

34-

57,9

0458

,716

60,4

33-

55,3

2256

,133

57,8

51-

52,1

6552

,977

54,6

95-

49,2

8450

,096

51,8

13-

S/T

0.70

0.62

0.49

-0.

710.

630.

50-

0.73

0.66

0.52

-0.

750.

670.

54-

1.00

0.70

0.56

-1.

000.

750.

61-

Evap

dT

18.0

716

.14

12.5

4-

18.0

216

.09

12.4

9-

18.2

916

.36

12.7

6-

18.0

016

.07

12.4

7-

17.7

415

.81

12.2

1-

18.9

517

.02

13.4

2-

Pr S

uc12

412

612

9-

131

133

136

-13

813

914

2-

143

145

148

-14

815

015

3-

155

156

159

-

Pr D

is25

825

926

1-

298

299

301

-34

034

134

3-

385

386

388

-43

343

443

6-

485

486

488

-

Tota

lPow

er3,

571

3,56

83,

561

-3,

987

3,98

43,

977

-4,

451

4,44

84,

441

-4,

953

4,95

04,

943

-5,

514

5,51

15,

504

-6,

173

6,16

96,

162

-

75

1500

Capa

city

57,1

7657

,988

59,7

0562

,328

56,6

6157

,473

59,1

9061

,813

55,1

6055

,972

57,6

8960

,312

52,5

7853

,390

55,1

0757

,730

49,4

2250

,233

51,9

5154

,574

46,5

4047

,352

49,0

6951

,692

S/T

0.68

0.61

0.47

0.33

0.69

0.61

0.48

0.34

0.71

0.64

0.50

0.36

1.00

0.66

0.52

0.38

1.00

0.68

0.55

0.40

1.00

0.73

0.60

0.45

Evap

dT

25.8

123

.88

20.2

716

.54

25.7

523

.82

20.2

216

.49

26.0

224

.09

20.4

916

.76

25.7

323

.80

20.2

016

.47

25.4

823

.55

19.9

416

.21

26.6

824

.75

21.1

517

.42

Pr S

uc11

812

012

312

812

512

713

013

513

213

313

614

113

713

814

214

714

214

414

715

214

915

015

315

8

Pr D

is25

225

325

425

929

129

329

429

933

333

433

634

037

837

938

138

542

742

842

943

447

847

948

148

6

Tota

lPow

er3,

504

3,50

13,

494

3,52

53,

920

3,91

63,

909

3,94

14,

384

4,38

14,

373

4,40

54,

886

4,88

34,

876

4,90

75,

447

5,44

45,

437

5,46

96,

106

6,10

26,

095

6,12

7

1850

Capa

city

58,2

7159

,083

60,8

0063

,423

57,7

5658

,568

60,2

8562

,908

56,2

5557

,067

58,7

8461

,407

53,6

7354

,485

56,2

0258

,825

50,5

1751

,329

53,0

4655

,669

47,6

3548

,447

50,1

6452

,787

S/T

0.78

0.71

0.57

0.43

0.79

0.71

0.58

0.44

1.00

0.74

0.61

0.46

1.00

0.76

0.62

0.48

1.00

0.78

0.65

0.51

1.00

0.83

0.70

0.56

Evap

dT

23.9

322

.01

18.4

014

.67

23.8

821

.95

18.3

514

.62

24.1

522

.22

18.6

214

.89

23.8

621

.93

18.3

314

.60

23.6

021

.67

18.0

714

.34

24.8

122

.88

19.2

815

.55

Pr S

uc12

112

212

513

012

812

913

213

713

413

613

914

414

014

114

414

914

514

614

915

415

115

315

616

1

Pr D

is25

525

625

826

229

529

629

830

233

733

833

934

438

138

338

438

943

043

143

343

748

248

348

548

9

Tota

lPow

er3,

539

3,53

53,

528

3,56

03,

954

3,95

13,

944

3,97

64,

418

4,41

54,

408

4,44

04,

921

4,91

74,

910

4,94

25,

482

5,47

95,

471

5,50

36,

140

6,13

76,

130

6,16

2

2250

Capa

city

59,9

5360

,765

62,4

8265

,105

59,4

3960

,250

61,9

6864

,591

57,9

3858

,749

60,4

6763

,090

55,3

5556

,167

57,8

8460

,507

52,1

9953

,011

54,7

2857

,351

49,3

1850

,130

51,8

4754

,470

S/T

0.83

0.75

0.62

0.48

0.83

0.76

0.62

0.48

1.00

0.78

0.65

0.51

1.00

0.80

0.67

0.53

1.00

0.82

0.69

0.55

1.00

1.00

0.74

0.60

Evap

dT

22.3

120

.38

16.7

813

.05

22.2

620

.33

16.7

313

.00

22.5

320

.60

17.0

013

.27

22.2

420

.31

16.7

112

.98

21.9

820

.05

16.4

512

.72

23.1

921

.26

17.6

613

.93

Pr S

uc12

412

612

913

413

113

313

614

113

813

914

214

714

314

514

815

314

815

015

315

815

515

615

916

5

Pr D

is25

926

026

126

629

829

930

130

634

034

134

334

738

538

638

839

243

443

543

644

148

548

648

849

3

Tota

lPow

er3,

569

3,56

53,

558

3,59

03,

984

3,98

13,

974

4,00

64,

448

4,44

54,

438

4,47

04,

951

4,94

74,

940

4,97

25,

512

5,50

85,

501

5,53

36,

170

6,16

76,

160

6,19

1

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s AC

CA (T

VA) c

ondi

tions

kW =

Tot

al s

yste

m p

ower

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 15: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Expanded Cooling Data

SS-DBH3-D www.daikinac.com 15

DBH060*DO

utdo

or A

mbi

ent T

empe

ratu

re

6575

8595

105

115

Ente

ring

Indo

or W

et B

ulb

Tem

pera

ture

IDB

Air

flow

ID W

B59

6367

7159

6367

7159

6367

7159

6367

7159

6367

7159

6367

71

80

1500

Capa

city

57,4

7358

,285

60,0

0262

,625

56,9

5957

,771

59,4

8862

,111

55,4

5856

,270

57,9

8760

,610

52,8

7553

,687

55,4

0458

,027

49,7

1950

,531

52,2

4854

,871

46,8

3847

,650

49,3

6751

,990

S/T

0.81

0.73

0.60

0.46

1.00

0.74

0.60

0.46

1.00

0.76

0.63

0.49

1.00

0.78

0.65

0.51

1.00

0.80

0.67

0.53

1.00

1.00

0.72

0.58

Evap

dT

30.0

828

.15

24.5

420

.81

30.0

228

.09

24.4

920

.76

30.2

928

.36

24.7

621

.03

30.0

028

.07

24.4

720

.74

29.7

527

.82

24.2

120

.48

30.9

529

.02

25.4

221

.69

Pr S

uc11

912

012

312

812

612

713

013

513

213

413

714

213

813

914

214

714

314

414

715

214

915

115

415

9

Pr D

is25

225

325

525

929

229

329

529

933

433

533

734

137

938

038

138

642

742

843

043

447

948

048

248

6

Tota

lPow

er3,

506

3,50

33,

496

3,52

83,

922

3,91

93,

912

3,94

34,

386

4,38

34,

376

4,40

74,

888

4,88

54,

878

4,91

05,

449

5,44

65,

439

5,47

16,

108

6,10

46,

097

6,12

9

1850

Capa

city

58,5

6959

,381

61,0

9863

,721

58,0

5458

,866

60,5

8363

,206

56,5

5357

,365

59,0

8261

,705

53,9

7154

,783

56,5

0059

,123

50,8

1551

,626

53,3

4455

,967

47,9

3348

,745

50,4

6253

,085

S/T

0.91

0.83

0.70

0.56

1.00

0.84

0.70

0.56

1.00

0.86

0.73

0.59

1.00

0.88

0.75

0.61

1.00

1.00

0.77

0.63

1.00

1.00

0.82

0.68

Evap

dT

28.2

026

.28

22.6

718

.94

28.1

526

.22

22.6

218

.89

28.4

226

.49

22.8

919

.16

28.1

326

.20

22.6

018

.87

27.8

725

.95

22.3

418

.61

29.0

827

.15

23.5

519

.82

Pr S

uc12

112

312

613

112

813

013

313

813

513

613

914

414

014

214

515

014

514

715

015

515

215

315

616

2

Pr D

is25

525

625

826

329

529

629

830

333

733

834

034

438

238

338

538

943

043

143

343

848

248

348

548

9

Tota

lPow

er3,

541

3,53

83,

530

3,56

23,

957

3,95

33,

946

3,97

84,

421

4,41

74,

410

4,44

24,

923

4,92

04,

913

4,94

45,

484

5,48

15,

474

5,50

56,

142

6,13

96,

132

6,16

4

2250

Capa

city

60,2

5161

,063

62,7

8065

,403

59,7

3660

,548

62,2

6564

,888

58,2

3559

,047

60,7

6463

,387

55,6

5356

,465

58,1

8260

,805

52,4

9753

,309

55,0

2657

,649

49,6

1550

,427

52,1

4554

,767

S/T

1.00

0.88

0.74

0.60

1.00

0.88

0.75

0.61

1.00

0.91

0.77

0.63

1.00

0.93

0.79

0.65

1.00

1.00

0.81

0.67

1.00

1.00

0.86

0.72

Evap

dT

26.5

824

.65

21.0

517

.32

26.5

324

.60

21.0

017

.27

26.8

024

.87

21.2

717

.54

26.5

124

.58

20.9

817

.25

26.2

524

.32

20.7

216

.99

27.4

625

.53

21.9

318

.20

Pr S

uc12

512

612

913

413

213

313

614

213

814

014

314

814

414

514

815

314

915

015

315

815

615

716

016

5

Pr D

is25

926

026

226

629

930

030

230

634

134

234

334

838

638

738

839

343

443

543

744

148

648

748

949

3

Tota

lPow

er3,

571

3,56

73,

560

3,59

23,

986

3,98

33,

976

4,00

84,

451

4,44

74,

440

4,47

24,

953

4,95

04,

942

4,97

45,

514

5,51

15,

504

5,53

56,

172

6,16

96,

162

6,19

4

85

1500

Capa

city

58,4

4259

,254

60,9

7163

,594

57,9

2758

,739

60,4

5663

,079

56,4

2657

,238

58,9

5561

,578

53,8

4454

,656

56,3

7358

,996

50,6

8851

,500

53,2

1755

,840

47,8

0748

,618

50,3

3652

,959

S/T

1.00

0.83

0.70

0.56

1.00

0.84

0.70

0.56

1.00

0.86

0.73

0.59

1.00

1.00

0.75

0.61

1.00

1.00

0.77

0.63

1.00

1.00

0.82

0.68

Evap

dT

33.8

631

.93

28.3

324

.60

33.8

131

.88

28.2

824

.55

34.0

832

.15

28.5

524

.82

33.7

931

.86

28.2

624

.53

33.5

331

.60

28.0

024

.27

34.7

432

.81

29.2

125

.48

Pr S

uc12

012

212

513

012

812

913

213

713

413

513

814

413

914

114

414

914

514

614

915

415

115

315

616

1

Pr D

is25

325

425

626

129

329

429

630

033

533

633

834

238

038

138

338

742

842

943

143

648

048

148

348

7

Tota

lPow

er3,

514

3,51

13,

504

3,53

63,

930

3,92

73,

919

3,95

14,

394

4,39

14,

384

4,41

54,

896

4,89

34,

886

4,91

85,

457

5,45

45,

447

5,47

96,

116

6,11

26,

105

6,13

7

1850

Capa

city

59,5

3760

,349

62,0

6664

,689

59,0

2359

,835

61,5

5264

,175

57,5

2258

,334

60,0

5162

,674

54,9

3955

,751

57,4

6860

,091

51,7

8352

,595

54,3

1256

,935

48,9

0249

,714

51,4

3154

,054

S/T

1.00

0.93

0.80

0.66

1.00

0.94

0.80

0.66

1.00

1.00

0.83

0.69

1.00

1.00

0.85

0.71

1.00

1.00

0.87

0.73

1.00

01.

000

0.92

10.

780

Evap

dT

31.9

930

.06

26.4

622

.73

31.9

430

.01

26.4

122

.68

32.2

130

.28

26.6

822

.95

31.9

229

.99

26.3

922

.66

31.6

629

.73

26.1

322

.40

32.8

730

.94

27.3

423

.61

Pr S

uc12

312

412

813

313

013

213

514

013

713

814

114

614

214

314

615

114

714

915

215

715

415

515

816

3

Pr D

is25

725

825

926

429

629

829

930

433

833

934

134

538

338

438

639

043

243

343

443

948

348

448

649

1

Tota

lPow

er3,

549

3,54

53,

538

3,57

03,

965

3,96

13,

954

3,98

64,

429

4,42

54,

418

4,45

04,

931

4,92

84,

920

4,95

25,

492

5,48

95,

482

5,51

36,

150

6,14

76,

140

6,17

2

2250

Capa

city

61,2

1962

,031

63,7

4966

,371

60,7

0561

,517

63,2

3465

,857

59,2

0460

,016

61,7

3364

,356

56,6

2157

,433

59,1

5061

,773

53,4

6554

,277

55,9

9458

,617

50,5

8451

,396

53,1

1355

,736

S/T

1.00

0.98

0.84

0.70

1.00

0.98

0.85

0.71

1.00

1.00

0.87

0.73

1.00

1.00

0.89

0.75

1.00

1.00

0.91

0.77

1.00

1.00

1.00

0.82

Evap

dT

30.3

728

.44

24.8

421

.11

30.3

128

.39

24.7

821

.05

30.5

928

.66

25.0

621

.32

30.3

028

.37

24.7

621

.03

30.0

428

.11

24.5

120

.78

31.2

529

.32

25.7

121

.98

Pr S

uc12

712

813

113

613

413

513

814

314

014

214

515

014

514

715

015

515

115

215

516

015

715

916

216

7

Pr D

is26

026

126

326

730

030

130

330

734

234

334

534

938

738

839

039

443

543

643

844

248

748

849

049

4

Tota

lPow

er3,

579

3,57

53,

568

3,60

03,

994

3,99

13,

984

4,01

64,

458

4,45

54,

448

4,48

04,

961

4,95

74,

950

4,98

25,

522

5,51

95,

511

5,54

36,

180

6,17

76,

170

6,20

2

IDB:

Ent

erin

g In

door

Dry

Bul

b Te

mpe

ratu

reSh

aded

are

a re

flect

s A

HRI

(TVA

) con

ditio

nskW

= T

otal

sys

tem

pow

er

Hig

h an

d lo

w p

ress

ures

are

mea

sure

d at

the

liqui

d an

d su

ctio

n ac

cess

fitt

ings

.A

mps

: Uni

t am

ps (c

omp.

+ ev

apor

ator

+ c

onde

nser

fan

mot

ors)

Des

ign

Subc

oolin

g, 1

6 - 1

9 °F

@ th

e liq

uid

acce

ss fi

ttin

g co

nnec

tion

ARI

95

test

con

ditio

ns. D

esig

n Su

perh

eat 8

- 12

°F @

the

com

pres

sor s

uctio

n ac

cess

fitt

ing

conn

ectio

n.

Page 16: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Electrical Heater Data

16 www.daikinac.com SS-DBH3-D

Electric Heaters

Mo

del

#

Min

Air

flo

w

Max

Air

flo

w

EH*D

-*S0

5

EH*D

-*S1

0

EH*D

-*S1

5

EH*D

-*S1

6

EH*D

-*S2

2

DBH036*D 1175 1350 X X X

DBH048*D 1300 1800 X X X X

DBH060*D 1625 2250 X X X X

Page 17: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Airflow

SS-DBH3-D www.daikinac.com 17

3 Ton Heat Pump - Downshot

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1115 0.15 115 5680.4 1095 0.17 126 6200.6 1004 0.19 141 6950.8 899 0.21 154 760

T2

0.2 1269 0.19 145 5680.4 1176 0.21 158 6210.6 1084 0.23 175 6960.8 991 0.26 192 760

T3

0.2 1365 0.23 170 6380.4 1262 0.24 178 6670.6 1166 0.26 196 7360.8 1034 0.29 216 808

T4

0.2 - - - -0.4 1378 0.30 223 6980.6 1291 0.33 244 7630.8 1197 0.36 268 839

T5

0.2 - - - -0.4 1447 0.33 249 7180.6 1358 0.36 270 7810.8 1254 0.40 298 860

4 Ton Heat Pump - Downshot

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1323 0.26 192 6750.4 1229 0.28 207 7290.6 1111 0.30 225 7930.8 1002 0.33 243 855

T2

0.2 1569 0.39 292 7610.4 1486 0.41 309 8070.6 1406 0.44 327 8520.8 1311 0.47 347 906

T3

0.2 1585 0.40 299 7670.4 1503 0.43 317 8120.6 1424 0.45 334 8560.8 1331 0.48 355 910

T4

0.2 1815 0.57 427 8480.4 1739 0.60 447 8880.6 1680 0.62 465 9220.8 1605 0.65 487 965

T5

0.2 1735 0.51 378 8200.4 1657 0.53 397 8610.6 1594 0.56 414 8980.8 1511 0.58 436 945

3 Ton Heat Pump - Horizontal

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1138 0.16 123 6040.4 1117 0.18 134 6600.6 1024 0.20 150 7390.8 917 0.22 164 808

T2

0.2 1295 0.21 154 6430.4 1200 0.23 168 7020.6 1106 0.25 186 7760.8 1011 0.27 204 851

T3

0.2 1393 0.24 181 6790.4 1288 0.25 190 7100.6 1190 0.28 209 7830.8 1055 0.31 229 859

T4

0.2 - - - -0.4 1406 0.32 237 7430.6 1317 0.35 259 8120.8 1221 0.38 285 893

T5

0.2 - - - -0.4 1476 0.36 265 7640.6 1385 0.39 288 8310.8 1280 0.42 317 915

4 Ton Heat Pump - Horizontal

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1350 0.27 204 7180.4 1254 0.30 220 7760.6 1134 0.32 240 8440.8 1022 0.35 258 910

T2

0.2 1601 0.42 310 8100.4 1517 0.44 329 8580.6 1434 0.47 348 9070.8 1338 0.50 370 964

T3

0.2 1617 0.43 318 8160.4 1534 0.45 337 8640.6 1453 0.48 356 9110.8 1358 0.51 378 968

T4

0.2 1852 0.61 455 9020.4 1775 0.64 476 9440.6 1715 0.66 494 9810.8 1637 0.69 518 1027

T5

0.2 1770 0.54 402 8720.4 1691 0.57 422 9150.6 1626 0.59 441 9550.8 1542 0.62 464 1005

3 Ton / 4 Ton – Horizontal / Downshot

Page 18: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

DBC3-D

Airflow

18 www.daikinac.com SS-DBH3-D

5 Ton – Horizontal / Downshot

5 Ton Heat Pump - Downshot

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1711 0.43 318 7590.4 1647 0.45 338 8070.6 1573 0.48 357 8520.8 1501 0.51 377 899

T2

0.2 1910 0.56 420 8220.4 1852 0.59 442 8640.6 1796 0.62 460 9010.8 1735 0.65 481 941

T3

0.2 1821 0.50 372 7940.4 1762 0.53 393 8390.6 1699 0.55 412 8780.8 1633 0.58 432 922

T4

0.2 2143 0.77 571 8930.4 2074 0.80 597 9340.6 2024 0.83 618 9670.8 1977 0.86 638 999

T5

0.2 1924 0.57 429 8270.4 1866 0.60 450 8690.6 1811 0.63 469 9040.8 1751 0.66 490 945

5 Ton Heat Pump - Horizontal

SPEED TAP

EXTERNAL STATIC PRESSURE (ESP)

in w. c.

STANDARD CFM

AMPS BHP RPM

T1

0.2 1746 0.45 338 8070.4 1681 0.48 359 8580.6 1605 0.51 380 9070.8 1532 0.54 401 957

T2

0.2 1949 0.60 447 8750.4 1889 0.63 470 9200.6 1832 0.66 490 9580.8 1770 0.69 512 1001

T3

0.2 1859 0.53 396 8450.4 1798 0.56 418 8920.6 1734 0.59 438 9340.8 1666 0.62 460 981

T4

0.2 2187 0.81 607 9500.4 2116 0.85 635 9930.6 2065 0.88 657 10290.8 2017 0.91 679 1063

T5

0.2 1964 0.61 456 8800.4 1904 0.64 479 9240.6 1848 0.67 499 9620.8 1786 0.70 521 1005

Page 19: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

SS-DBH3-D www.daikinac.com 19

DBC3-D

Electrical DataElectrical Data

Model Number

Electrical Rating

CompressorOutdoor Fan

MotorIndoor Fan Motor Optional Electric Heat

Optional Powered Convienience Outlet

Optional Power Exhaust

Power Supply

QTY RLA LRA QTY HP FLA Type HP FLA PART # KW* FLA FLA FLA MCA MOP

DBH0361D 208/230/1/60 1 16.67 79 1 0.17 0.95Direct Drive

Standard Static

0.75 5.7

- - - - - 27.5/27.5 40/40- - - 9.6/8.7 - 37.1/36.2 50/50- - - - 1.7/1.5 29.2/29.0 40/40- - - 9.6/8.7 1.7/1.5 38.8/37.7 50/50

EH*D-1S05 3.76/5.00 18.1/20.8

- - 50.1/53.5 60/609.6/8.7 - 59.7/62.2 70/70

- 1.7/1.5 51.8/55.0 60/609.6/8.7 1.7/1.5 61.4/63.7 70/70

EH*D-1S10 7.51/10.0 36.1/41.7

- - 72.6/79.6 80/809.6/8.7 - 82.2/88.3 90/90

- 1.7/1.5 74.3/81.1 80/909.6/8.7 1.7/1.5 83.9/89.8 90/90

EH*D-1S16 11.3/15.0 54.2/62.5

- - 95.2/106 100/1109.6/8.7 - 105/114 110/125

- 1.7/1.5 96.9/107 100/1109.6/8.7 1.7/1.5 106/116 110/125

DBH0363D 208/230/3/60 1 10.45 73 1 0.17 0.95Direct Drive

Standard Static

0.75 5.7

- - - - - 19.7/19.7 30/30- - - 9.6/8.7 - 29.3/28.4 35/35- - - - 1.7/1.5 21.4/21.2 30/30- - - 9.6/8.7 1.7/1.5 31.0/29.9 35/35

EH*D-3S05 3.76/5.00 10.4/12.0

- - 32.7/34.7 40/409.6/8.7 - 42.3/43.4 50/50

- 1.7/1.5 34.4/36.2 40/409.6/8.7 1.7/1.5 44.0/44.9 50/50

EH*D-3S10 7.51/10.0 20.8/24.1

- - 45.8/49.8 50/509.6/8.7 - 55.4/58.5 60/60

- 1.7/1.5 47.5/51.3 50/609.6/8.7 1.7/1.5 57.1/60.0 60/60

EH*D-3S16 11.3/15.0 31.3/36.1

- - 58.8/64.8 60/709.6/8.7 - 68.4/73.5 70/80

- 1.7/1.5 60.5/66.3 70/709.6/8.7 1.7/1.5 70.1/75.0 80/80

DBH0481D 208/230/1/60 1 19.87 109 1 0.25 1.4Direct Drive

Standard Static

1 6.9

- - - - - 33.1/33.1 50/50- - - 9.6/8.7 - 42.7/41.8 60/60- - - - 1.7/1.5 34.8/34.6 50/50- - - 9.6/8.7 1.7/1.5 44.4/43.3 60/60

EH*D-1S05 3.76/5.00 18.1/20.8

- - 55.7/59.2 70/709.6/8.7 - 65.3/67.9 80/80

- 1.7/1.5 57.4/60.7 70/709.6/8.7 1.7/1.5 67.0/69.4 80/80

EH*D-1S10 7.51/10.0 36.1/41.7

- - 78.3/85.2 80/909.6/8.7 - 87.9/93.9 90/100

- 1.7/1.5 80.0/86.7 80/909.6/8.7 1.7/1.5 89.6/95.4 90/100

EH*D-1S15 11.3/15.0 54.2/62.5

- - 101/111 110/1259.6/8.7 - 110/120 125/125

- 1.7/1.5 103/113 110/1259.6/8.7 1.7/1.5 112/121 125/125

EH*D-1S22 15.0/20.0 72.2/83.3

- - 123/137 125/1509.6/8.7 - 133/146 150/150

- 1.7/1.5 125/139 150/1509.6/8.7 1.7/1.5 135/148 150/150

DBH0483D 208/230/3/60 1 13.14 83.1 1 0.25 1.4Direct Drive

Standard Static

1 6.9

- - - - - 24.7/24.7 35/35- - - 9.6/8.7 - 34.3/33.4 45/45- - - - 1.7/1.5 26.4/26.2 35/35- - - 9.6/8.7 1.7/1.5 36.0/34.9 45/45

EH*D-3S05 3.76/5.00 10.4/12.0

- - 37.8/39.8 45/459.6/8.7 - 47.4/48.5 50/50

- 1.7/1.5 39.5/41.3 45/459.6/8.7 1.7/1.5 49.1/50.0 50/50

EH*D-3S10 7.51/10.0 20.8/24.1

- - 50.8/54.8 60/609.6/8.7 - 60.4/63.5 70/70

- 1.7/1.5 52.5/56.3 60/609.6/8.7 1.7/1.5 62.1/65.0 70/70

EH*D-3S15 11.3/15.0 31.3/36.1

- - 63.8/69.8 70/709.6/8.7 - 73.4/78.5 80/80

- 1.7/1.5 65.5/71.3 70/809.6/8.7 1.7/1.5 75.1/80.0 80/90

EH*D-3S22 15.0/19.9 41.5/47.9

- - 76.6/84.6 80/909.6/8.7 - 86.2/93.3 90/100

- 1.7/1.5 78.3/86.1 80/909.6/8.7 1.7/1.5 87.9/94.8 90/100

Page 20: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

20 www.daikinac.com SS-DBH3-C

DBC3-D

Electrical Data

Model Number

Electrical Rating

CompressorOutdoor Fan

MotorIndoor Fan Motor Optional Electric Heat

Optional Powered Convienience Outlet

Optional Power Exhaust

Power Supply

QTY RLA LRA QTY HP FLA Type HP FLA PART # KW* FLA FLA FLA MCA MOP

DBH0601D 208/230/1/60 1 25.00 134 1 0.33 2.3Direct Drive

Standard Static

1 6.9

- - - - - 40.4/40.4 60/60- - - 9.6/8.7 - 50.0/49.1 70/70- - - - 1.7/1.5 42.1/41.9 60/60- - - 9.6/8.7 1.7/1.5 51.7/50.6 70/70

EH*D-1S05 3.76/5.00 18.1/20.8

- - 63.0/66.5 80/809.6/8.7 - 72.6/75.2 90/90

- 1.7/1.5 64.7/68.0 80/809.6/8.7 1.7/1.5 74.3/76.7 90/90

EH*D-1S10 7.51/10.0 36.1/41.7

- - 85.6/92.5 100/1009.6/8.7 - 95.2/101 110/110

- 1.7/1.5 87.3/94.0 100/1009.6/8.7 1.7/1.5 96.9/103 110/110

EH*D-1S15 11.3/15.0 54.2/62.5

- - 108/119 110/1259.6/8.7 - 118/127 125/150

- 1.7/1.5 110/120 110/1259.6/8.7 1.7/1.5 119/129 125/150

EH*D-1S22 15.0/20.0 72.2/83.3

- - 131/145 150/1509.6/8.7 - 140/153 150/175

- 1.7/1.5 132/146 150/1509.6/8.7 1.7/1.5 142/155 150/175

DBH0603D 208/230/3/60 1 15.90 110 1 0.33 2.3Direct Drive

Standard Static

1 6.9

- - - - - 29.1/29.1 40/40- - - 9.6/8.7 - 38.7/37.8 50/50- - - - 1.7/1.5 30.8/30.6 40/40- - - 9.6/8.7 1.7/1.5 40.4/39.3 50/50

EH*D-3S05 3.76/5.00 10.4/12.0

- - 42.1/44.1 50/509.6/8.7 - 51.7/52.8 60/60

- 1.7/1.5 43.8/45.6 50/509.6/8.7 1.7/1.5 53.4/54.3 60/60

EH*D-3S10 7.51/10.0 20.8/24.1

- - 55.1/59.1 60/609.6/8.7 - 64.7/67.8 70/70

- 1.7/1.5 56.8/60.6 60/709.6/8.7 1.7/1.5 66.4/69.3 70/70

EH*D-3S15 11.3/15.0 31.3/36.1

- - 68.2/74.2 70/809.6/8.7 - 77.8/82.9 80/90

- 1.7/1.5 69.9/75.7 70/809.6/8.7 1.7/1.5 79.5/84.4 80/90

EH*D-3S22 15.0/19.9 41.5/47.9

- - 80.9/88.9 90/909.6/8.7 - 90.5/97.6 100/100

- 1.7/1.5 82.6/90.4 90/1009.6/8.7 1.7/1.5 92.2/99.1 100/100

Page 21: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Wire Diagram

SS-DBH3-D www.daikinac.com 21

DBC3-D

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r dea

th.⚡

1 Phase Diagram

BC

BLO

WE

R C

ON

TAC

TOR

BM

BLO

WE

R M

OT

OR

CB

CIR

CU

IT B

RE

AK

ER

CC

CO

MP

RE

SS

OR

CO

NTA

CTO

RC

CH

CR

AN

KC

AS

E H

EA

TER

CC

PC

OM

PR

ES

SO

R/C

OIL

PR

OTE

CTI

ON

CH

RC

RA

NK

AS

E H

EA

TER

RE

LAY

CH

SC

RA

NK

CA

SE

HE

ATE

R S

WIT

CH

CM

CO

ND

EN

SE

R M

OTO

RC

MC

CO

ND

EN

SE

R M

OTO

R C

ON

TAC

TOR

CO

MP

CO

MP

RE

SS

OR

DFT

DE

FRO

ST

TEM

PE

RA

TUR

E S

WIT

CH

DR

DE

FRO

ST

RE

LAY

EC

ON

EC

ON

OM

IZER

EH

KE

LEC

TRIC

HE

AT

KIT

ES

EM

ER

GE

NC

Y S

HU

TDO

WN

FBFU

SE

BLO

CK

FPS

FRE

EZE

PR

OTE

CTI

ON

SW

ITC

HG

ND

EQ

UIP

ME

NT

GR

OU

ND

HP

SH

IGH

PR

ES

SU

RE

SW

ITC

HM

AT

MIX

ED

AIR

TE

MP

. SE

NS

OR

RC

RU

N C

AP

AC

ITO

R

LPS

LOW

PR

ES

SU

RE

SW

ITC

HP

BP

OW

ER

DIS

TRIB

UTI

ON

BLO

CK

PLF

FEM

ALE

PLU

G/C

ON

NE

CTO

RP

LMM

ALE

PLU

G/C

ON

NE

CTO

RR

VC

RE

VE

RS

ING

VA

LVE

CO

ILTB

TER

MIN

AL

BLO

CK

TRTR

AN

SFO

RM

ER

RD

121110987654321

121110987654321

4321

4321

O-R

V

R-P

S1

R-D

FTPS

2 RO

C-R

VCC

DFT

DF1

DF2

PC

B

W

CN

T Y

987654321

BL

BK

GR

RD

BK

RD

BK

RD

BL

BL

BL

54321

BK

RD

POW

ER A

ND

CO

NTR

OLS

WIR

ING

DIA

GR

AMD

BH0

36-0

60, 1

PH

ASE,

DIR

ECT

DRI

VE

BK

OR

BL

BL

NGLC

NGLC

4321 5

654321

654321

2121

DE

FRO

ST

CO

NTR

OL

CH

S

TR1

CB

GR

4

EC

ON

PLM

EC

ON

PLF

PU

YL

TB1

ES

PLM

ES

PLF

RD

RD

PK

GR

RD

PK

YL

PU

BL

GR

OR

PK

2

BL

6

TB1

W2

Y1

OY

2S

2R

W1

CS

1G

DH

T1T2

T3T4

T5

GY

YL

WH

PU

PU

WH

BR

YL

GR

TB2

BA

CDBL

BL

CM

CA

2 BL

CC

A1

A2

BL

WIR

E C

OD

E

BLA

CK

BLU

EB

LUE

WIT

H P

INK

STR

IPE

BR

OW

NG

RE

EN

GR

AY

OR

AN

GE

PIN

KP

UR

PLE

RE

DTA

NW

HIT

EY

ELL

OW

YE

LLO

W W

ITH

PIN

K S

TRIP

E

BK

BL

BL/

PK

BR

GR

GY

OR

PK

PU

RD

TN WH

YL

YL/

PK

HIG

H V

OLT

AG

ELO

W V

OLT

AG

EO

PTI

ON

AL

HIG

H V

OLT

AG

EO

PTI

ON

AL

LOW

VO

LTA

GE

CH

AS

SIS

GR

OU

ND

FIEL

DW

IRIN

G

FACT

OR

YW

IRIN

G

HIG

H V

OLT

AG

ELO

W V

OLT

AG

E

EA

RTH

GR

OU

ND

CO

MPO

NE

NT

LEG

EN

D

RD

RD

CO

M

BC

A1

A2

BL

GR

YL

WH

PU

BL

YL

BL

YL

EH

KP

LF

DR

13

BL

PK

DFT

YL

PU

PU

BL

BR

BR

WH

YL

WH

PK

GY

BK

RD

RD

BL

BL

BL

BR

WH

BL

BR

GY

3

PB

L1

GN

D

L2

LIN

EV

OLT

AG

E

FB1

F1 F1

BK

RD

208-

230V

/1P

H/6

0Hz

L1 L2

T1 T2C S

CM

BR

RD

GR

FB3

F3 F3

5

RD YL

BR

BK PU

PU

BK

5

L1 L2

T1 T2

BK

BC

CO

MP

RC

CO

M

FAN

PU

PU

CM

CL1 L2

T1 T2

GR YL

PU

BR

BM

PLF

1

WH

FB2

F2 F2

BK

RD

BK

PU

BR

5

R

YL

BK

A1

PUYL

GR

WH

BR

PLM

2B

MP

LF2

BM

PLM

1B

M

BM

PK

PK

RD

PK

GR

GRM 1~ M 1~ M 1~

YL

HP

S

LPS

CC

PP

LFC

CP

PLM

BL

BL

YL

YL

BL/

PK

YL/

PK

YL/

PK

BL/

PK

PU

BK

BK

BK

BK

YL

PU

PUYL

YL

PU PU

PK

7

YL

OR

BL

GY

BK

CC

BK

PLFCM

PLMCM

YL

RD

PK

0140

L071

92-A

OR

GY

WH

GR

YL

BR

GR YL

BK

CH

R1

BL

0P

KP

KR

DR

D

BL

PK

PK BL

8

GR

YL

BR

BL

OR

GY

DR

24

OR

GY

OR

RV

CV

2V

1B

LB

K

PK

YL

BL

HE

RM

THE

RM

OST

AT F

IELD

WIR

ING

++

1 S

TAG

E C

OO

LIN

G/H

EA

TIN

G2

STA

GE

CO

OLI

NG

/HE

ATI

NG

TB1

STA

T

W1

G R Y1

C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

W2

BR

Y2

PU

TB1

STA

T

W G R Y C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

THE

RM

OS

TAT+

+

NO

TES

RE

PLA

CE

ME

NT

WIR

E M

US

T B

E S

AM

E S

IZE

AN

D T

YP

E O

F IN

SU

LATI

ON

AS

OR

IGIN

AL

(AT

LEA

ST

105°

C).

US

E C

OP

PE

R C

ON

DU

CTO

RS

ON

LY. U

SE

N.E

.C. C

LAS

S 2

WIR

E F

OR

ALL

LOW

VO

LTA

GE

FIE

LD C

ON

NE

CTI

ON

S.

IF O

PTI

ON

AL

EC

ON

OM

IZE

R IS

INS

TALL

ED

RE

MO

VE

EC

ON

PLM

JU

MP

ER

AN

D P

LUG

INN

EW

HA

RN

ES

S F

RO

M E

CO

NO

MIZ

ER K

IT.

IF O

PTI

ON

AL

ELE

CTR

IC H

EA

T IS

INS

TALL

ED

,P

LUG

IN N

EW

HA

RN

ES

S F

RO

M E

LEC

TRIC

HE

ATE

R K

IT.

TR1

PR

IMA

RY

(HIG

H V

OLT

AG

E)

CO

NN

EC

TIO

NS

: O

RA

NG

E W

IRE

CO

NN

EC

TED

TO 2

40/4

60/5

75V

TA

P A

T TH

E F

AC

TOR

Y A

ND

BLA

CK

WIR

E T

O C

OM

TE

RM

INA

L. F

OR

208

VS

UP

PLY

PO

WE

R, M

OV

E O

RA

NG

E W

IRE

FR

OM

240/

460/

575V

TA

P T

O T

HE

208

V T

AP

.

FUS

E B

LOC

KS

1, 2

, & 3

AR

E O

PTI

ON

AL

IF O

PTI

ON

AL

SA

FETY

EQ

UIP

ME

NT

SU

CH

AS

AP

HA

SE

MO

NIT

OR

, FLO

AT

SW

ITC

H O

R S

MO

KE

DE

TEC

TOR

IS IN

STA

LLE

D, U

NP

LUG

JU

MP

ER

PLU

G A

ND

PLU

G IN

SA

FETY

DE

VIC

E. I

F M

ULT

IPLE

SA

FETI

ES

AR

E IN

STA

LLE

D, P

LUG

IN T

HE

AD

DIT

ION

AL

DE

VIC

ES

IN S

ER

IES

. PLU

G IN

JUM

PE

R P

LUG

AT

THE

LA

ST

SA

FETY

DE

VIC

EIN

STA

LLE

D.

24 V

AC

ALA

RM

OU

TPU

T FR

OM

OP

TIO

NA

LE

CO

NO

MIZ

ER

CO

NTR

OL

MO

DU

LE.

TO C

HA

NG

E E

VA

PO

RA

TOR

MO

TOR

SP

EE

D,

MO

VE

GR

EE

N (F

AN

ON

LY/L

OW

HE

AT)

, YE

LLO

W(C

OO

LIN

G),

OR

BR

OW

N (H

IGH

HE

AT)

WIR

ES

TO

AP

PR

OV

ED

SP

EE

D T

AP

. ALL

WIR

ES

MU

ST

BE

ON

DIF

FER

EN

T S

PE

ED

TA

PS

. SE

EIN

STA

LLA

TIO

N IN

STR

UC

TIO

NS

FO

R F

UR

THE

RD

ETA

ILS

ON

AD

JUS

TIN

G M

OTO

R.

RE

MO

VE B

LAC

K JU

MPE

R W

IRE

IF O

PTIO

NAL

FREE

ZEST

AT IS

INS

TALL

ED.

MA

TP

LF

BK

BK

21

CC

H

BK

GR

RD

BK

BK

CH

R

CH

R

24

68

FPS

BK

BK

9

1 2 3 4 5

6 7 8 9

Page 22: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Wire Diagram

22 www.daikinac.com SS-DBH3-D

3 Phase Diagram

Wiri

ng i

s su

bjec

t to

cha

nge.

Alw

ays

refe

r to

the

wiri

ng d

iagr

am o

n th

e un

it fo

r th

e m

ost

up-t

o-da

te w

iring

.⚠

War

ning

Hig

h Vo

ltage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, o

r dea

th.⚡

BC

BLO

WE

R C

ON

TAC

TOR

BM

BLO

WE

R M

OT

OR

CB

CIR

CU

IT B

RE

AK

ER

CC

CO

MPR

ES

SO

R C

ON

TAC

TOR

CC

HC

RA

NK

CA

SE

HE

ATE

RC

CP

CO

MPR

ES

SO

R/C

OIL

PR

OTE

CTI

ON

CH

RC

RA

NK

AS

E H

EA

TER

RE

LAY

CH

SC

RA

NK

CA

SE

HE

ATE

R S

WIT

CH

CM

CO

ND

EN

SE

R M

OTO

RC

MC

CO

ND

EN

SE

R M

OTO

R C

ON

TAC

TOR

CO

MP

CO

MPR

ES

SO

RD

FTD

EFR

OS

T TE

MP

ER

ATU

RE

SW

ITC

HD

RD

EFR

OS

T R

ELA

YE

CO

NE

CO

NO

MIZ

ERE

HK

ELE

CTR

IC H

EA

T K

ITE

SE

ME

RG

EN

CY

SH

UTD

OW

NFB

FUS

E B

LOC

KFC

FAN

CA

PA

CIT

OR

FPS

FRE

EZE

PR

OTE

CTI

ON

SW

ITC

HG

ND

EQ

UIP

ME

NT

GR

OU

ND

HP

SH

IGH

PR

ES

SU

RE

SW

ITC

HM

AT

MIX

ED

AIR

TE

MP

. SE

NS

OR

LPS

LOW

PR

ES

SU

RE

SW

ITC

HP

BP

OW

ER

DIS

TRIB

UTI

ON

BLO

CK

PLF

FEM

ALE

PLU

G/C

ON

NE

CTO

RP

LMM

ALE

PLU

G/C

ON

NE

CTO

RR

VC

RE

VE

RS

ING

VA

LVE

CO

ILTB

TER

MIN

AL

BLO

CK

TRTR

AN

SFO

RM

ER

CC

H

BK

GR

RD

BK

BK

CH

R

CH

R

24

68

121110987654321

121110987654321

4321

4321

O-R

V

R-P

S1

R-D

FTPS

2 RO

C-R

VCC

DFT DF1

DF2

PC

B

W

CN

T Y

987654321

BL BL

54321

654321

654321D

EFR

OS

T C

ON

TRO

L

CH

S

RD

CC

POW

ER A

ND

CO

NTR

OLS

WIR

ING

DIA

GR

AMD

BH0

36-0

60, 3

PH

ASE,

DIR

ECT

DRI

VE 2121

BK

GR

RD

BK

RD

BK

RD

BL

BL

NGLC

NGLC

4321 5

EC

ON

PLM

EC

ON

PLF

PU

YL

TB1

ES

PLM

ES

PLF

RD

RD

PK

GR

RD

PK

YL

PU

BL

GR

OR

PK

2

BL

6

TB1

W2

Y1

OY

2S

2R

W1

CS

1G

DH

T1T2

T3T4

T5

GY

YL

WH

PU

PU

WH

BR

YL

GR

TB2

BA

CDBL

BL

CM

CA

2 BL

CC

A1

A2

BL

WIR

E CO

DE

BLA

CK

BLU

EB

LUE

WIT

H P

INK

STR

IPE

BR

OW

NG

RE

EN

GR

AY

OR

AN

GE

PIN

KP

UR

PLE

RE

DTA

NW

HIT

EY

ELL

OW

YE

LLO

W W

ITH

PIN

K S

TRIP

E

BK

BL

BL/

PK

BR

GR

GY

OR

PK

PU

RD

TN WH

YL

YL/

PK

HIG

H V

OLT

AG

ELO

W V

OLT

AG

EO

PTI

ON

AL

HIG

H V

OLT

AG

EO

PTI

ON

AL

LOW

VO

LTA

GE

CH

AS

SIS

GR

OU

ND

FIEL

DW

IRIN

G HIG

H V

OLT

AG

ELO

W V

OLT

AG

E

EA

RTH

GR

OU

ND

CO

MPO

NENT

LEG

END

RD

RD

BC

A1

A2

BL

GR

YL

WH

PU

BL

YL

BL

YL

EH

KP

LF

RV

CV

2V

1B

L

DR

13

BL

DFT

YL

PU

PU

BL

BR

BR

WH

YL

WH

PK

GY

BK

RD

RD

BL

BL

BL

BR

WH

BL

BR

BK

3

GR YL

PU

BR

BM

PLF

1

WH

YL A

1

PK

PK

RD

PK

YL

HP

S

LPS

CC

PP

LFC

CP

PLM

BL

BL

YL

YL

BL/

PK

YL/

PK

YL/

PK

BL/

PK

PU

BK

BK

BK

BK

YL

PU

PUYL

YL

PU PU

PK

7

YL

OR

BL

GY

PK

0140

L071

93-A

OR

GY

WH

GR

YL

BR

GR YL

BK

FPS

BK

BK

9

CH

R1

BL

0P

KP

KR

DR

D

BL

PK

PK BL

8

GR

YL

BR

L1 L2

T3

CO

MP

L3

T1 T2

BK

L3L1

CM

PB

L1

GN

D

L2L3

LIN

EV

OLT

AG

E

PU

BR

BK

PUBR

BK

RD

OR

TR1

CB

GR

BK

RD

OR

RD

L2

4

208-

230V

/3P

H/6

0Hz

FB1

5

BK

BK

RD

OR

CO

M

F1F1F1

BK

L1T1

CM

C

L2T2

OR

FB2

F2 F2R

D

BK

RD

BK

PUBK

5

FC

GR

GR M 1~M 3~ BK

PLFCM

PLMCM

YL

BK

GR

FB3

F3 F3

5L1 L2

T1 T2

BC

PUYL

GR

WH

BR

PLM

2B

MP

LF2

BM

PLM

1B

M

BM

M 1~

YL

BLBL

OR

GY

OR

DR

24

GY

OR

THER

MO

STAT

FIE

LDW

IRIN

G++

1 S

TAG

E C

OO

LIN

G/H

EA

TIN

G2

STA

GE

CO

OLI

NG

/HE

ATI

NG

TB1

STA

T

W1

G R Y1

C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

W2

BR

Y2

PU

TB1

STA

T

W G R Y C O

WH

GR

PK

YL

BL

OR

W1

W2 G R Y1

Y2 C O

THE

RM

OS

TAT+

+

FACT

ORY

WIR

ING

1 2 3 4 5

6 7 8

NO

TES

RE

PLA

CE

ME

NT

WIR

E M

US

T B

E S

AM

E S

IZE

AN

D T

YP

E O

F IN

SU

LATI

ON

AS

OR

IGIN

AL

(AT

LEA

ST

105°

C).

US

E C

OP

PE

R C

ON

DU

CTO

RS

ON

LY. U

SE

N.E

.C. C

LAS

S 2

WIR

E F

OR

ALL

LOW

VO

LTA

GE

FIE

LD C

ON

NE

CTI

ON

S.

IF O

PTI

ON

AL

EC

ON

OM

IZER

IS IN

STA

LLE

DR

EM

OV

E E

CO

N P

LM J

UM

PE

R A

ND

PLU

G IN

NE

W H

AR

NE

SS

FR

OM

EC

ON

OM

IZER

KIT

.

IF O

PTI

ON

AL

ELE

CTR

IC H

EA

T IS

INS

TALL

ED

,P

LUG

IN N

EW

HA

RN

ES

S F

RO

M E

LEC

TRIC

HE

ATE

R K

IT.

TR1

PR

IMAR

Y (H

IGH

VO

LTA

GE

)C

ON

NE

CTI

ON

S:

OR

AN

GE

WIR

E C

ON

NE

CTE

DTO

240

/460

/575

V T

AP

AT

THE

FA

CTO

RY

AN

DB

LAC

K W

IRE

TO

CO

M T

ER

MIN

AL.

FO

R 2

08V

SU

PP

LY P

OW

ER

, MO

VE

OR

AN

GE

WIR

E F

RO

M24

0/46

0/57

5V T

AP

TO

TH

E 2

08V

TA

P.

FUS

E B

LOC

KS

1, 2

, & 3

AR

E O

PTI

ON

AL

IF O

PTI

ON

AL

SA

FETY

EQ

UIP

ME

NT

SU

CH

AS

AP

HA

SE

MO

NIT

OR

, FLO

AT

SW

ITC

H O

R S

MO

KE

DE

TEC

TOR

IS IN

STA

LLE

D, U

NP

LUG

JU

MP

ER

PLU

G A

ND

PLU

G IN

SA

FETY

DE

VIC

E. I

F M

ULT

IPLE

SA

FETI

ES

AR

E IN

STA

LLE

D, P

LUG

IN T

HE

AD

DIT

ION

AL

DE

VIC

ES

IN S

ER

IES

. PLU

G IN

JUM

PE

R P

LUG

AT

THE

LA

ST

SA

FETY

DE

VIC

EIN

STA

LLE

D.

24 V

AC

ALA

RM

OU

TPU

T FR

OM

OP

TIO

NA

LE

CO

NO

MIZ

ER C

ON

TRO

L M

OD

ULE

.

TO C

HA

NG

E E

VA

PO

RA

TOR

MO

TOR

SP

EE

D,

MO

VE

GR

EEN

(FA

N O

NLY

/LO

W H

EA

T), Y

ELL

OW

(CO

OLI

NG

), O

R B

RO

WN

(HIG

H H

EA

T) W

IRE

S T

OA

PP

RO

VE

D S

PE

ED

TA

P. A

LL W

IRE

S M

US

T B

EO

N D

IFFE

RE

NT

SP

EE

D T

AP

S. S

EE

INS

TALL

ATI

ON

INS

TRU

CTI

ON

S F

OR

FU

RTH

ER

DE

TAIL

S O

N A

DJU

STI

NG

MO

TOR

.

REM

OVE

BLA

CK

JUM

PER

WIR

E IF

OPT

ION

ALFR

EEZE

STAT

IS IN

STAL

LED

.9

YL

PK

PK

MA

TP

LF

BK

BK

21

Page 23: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Dimensional Data

SS-DBH3-D www.daikinac.com 23

Dimensions — 3 - 5 Tons

Model Size DIM “A”

3-4 ton HP 39⅞

5 ton HP 43½"

Page 24: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

24 www.daikinac.com SS-DBH3-D

DBC3-D

Electrical Connections

Unit ClearancesService ClearanceAllow for recommended service clearances as shown in figure to the right. In situations that have multiple units, a 36” minimum clearance is required between the condenser coils. A clearance of 48” is recommended on all sides of the unit to allow service access and to insure proper ventilation and condenser airflow. The top of the unit should be unobstructed. Provide a roof walkway along the sides of the unit for service and access to controls and components. Contact your Daikin sales representative for service requirements less than those recommended.

24" MIN. 24" MIN.

36” MIN.

NOTE: CHECK TRANSFORMER TO MATCH THECORRECT VOLTAGE TAP WITH LINE VOLTAGE

GROUND LUG

LOW VOLTAGE BLOCK

CONTROL BOX

POWER AND LOW VOLTAGE BLOCK CONNECTIONS

Page 25: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

SS-DBH3-D www.daikinac.com 25

DBC3-D

Unit LocationThe structural engineer must verify that the roof has adequate support and ability to minimize deflection. Take extreme caution when using on a wooden roof structure. Unit condenser coils should be in a location that avoids any heated exhaust air.

Allow sufficient space around the unit for maintenance/service clearance. Consult your Daikin sales representative if available clearances do not meet minimum recommendations.

Where code considerations, such as the NEC, require extended clearances, these take precedence.

Provisions for forks have been included in the unit base frame. No other fork locations are approved.

» Unit must be lifted by the four lifting holes located at the base frame corners.

» Lifting cables should be attached to the unit with shackles.

» The distance between the crane hook and the top of the unit must not be less than 60”.

» Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base

Installation

frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rigging label on the unit.

Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Lower unit carefully onto roof mounting curb. While rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. With condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. When a rectangular cantilever curb is used, take care to center the unit. Check for proper alignment and orientation of supply and return openings with duct.

Roof Curb InstallationThe roof curb is field-assembled and must be installed level (within 1/16” per foot side to side). A sub-base must be constructed by the contractor in applications involving pitched roofs. Gaskets are furnished and must be installed between the unit and curb. For proper installation, follow NRCA guidelines. In applications requiring post and rail installation, an I-beam securely mounted on multiple posts should support the unit on each side. In addition, the insulation on the underside of the unit should be protected from the elements. Applications in geographic areas subjected to seismic or hurricane conditions must meet code requirements for fastening the unit to the curb and the curb to the building structure. For further and more detailed information please refer to our Daikin Light Commercial Packaged unit IOD.

Corner & Center-of-Gravity Locations

Weights

A

ModelShipping

Weight (lbs)Operating

Weight (lbs)Corner Weights (lbs) Length Width

A B C D X (in) Y (in)

DBH0363D000001S 605 560 102 186 136 136 35⅘ 27⅘

DBH0483D000001S 629 589 162 165 111 151 32⅘ 259/10

DBH0603D000001S 672 632 198 149 92 193 33⅓ 26⅕

Page 26: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Accessories

26 www.daikinac.com SS-DBH3-D

Field Accessory part number

Description Fits Model Sizes Field-Installed Factory-InstalledOperating

Weight (lbs)

Electric Heat Kits

EHXD-1S05 Electric Heater, Direct Drive, 208-230V, 1PH, 5kW 3-5 ton √ √

EHXD-1S10 Electric Heater, Direct Drive, 208-230V, 1PH, 10kW 3-5 ton √ √

EHXD-1S16 Electric Heater, Direct Drive, 208-230V, 1PH, 15kW 3 ton √ √

EHXD-1S15 Electric Heater, Direct Drive, 208-230V, 1PH, 15kW 4-5 ton √ √

EHXD-1S22 Electric Heater, Direct Drive, 208-230V, 1PH, 20kW 4-5 ton √ √

EHXD-3S05 Electric Heater, Direct Drive, 208-230V, 3PH, 5kW 3-5 ton √ √

EHXD-3S10 Electric Heater, Direct Drive, 208-230V, 3PH, 10kW 3-5 ton √ √

EHXD-3S16 Electric Heater, Direct Drive, 208-230V, 3PH, 15kW 3 ton √ √

EHXD-3S15 Electric Heater, Direct Drive, 208-230V, 3PH, 15kW 4-5 ton √ √

EHXD-3S22 Electric Heater, Direct Drive, 208-230V, 3PH, 20kW 4-5 ton √ √

Duct Smoke Detectors

Duct Smoke Detectors - Return 3-5 ton √ 11

Duct Smoke Detectors - Supply 3-5 ton √ 11

Duct Smoke Detectors - Supply and Return 3-5 ton √ 11

Non-Fused Disconnect Switch

60 Amp Disconnect 3-5 ton √ 5

100 Amp Disconnect 3-5 ton √ 5

150 Amp Disconnect 3-5 ton √ 5

Convenience Outlets

Convenience Outlets - Powered, 208/230 V 3-5 ton √ 42

Convenience Outlets - Non-Powered 3-5 ton √ 2

Hinged Access Panels

Hinged Access Panels, 39" cabinet 3-4 ton √

Hinged Access Panels, 43" cabinet 5 ton √

Economizer

0270L01163 Horizontal Economizer Ultra Low-Leak JADE Dry-Bulb, 39" cabinet 3-4 ton √ 88

0270L01759 Horizontal Economizer Ultra Low-Leak JADE Enthalpy Sensor, 39" cabinet 3-4 ton √ 88

0270L01598 Horizontal Economizer Ultra Low-Leak JADE Dry-Bulb, 43" cabinet 5 ton √ 88

0270L01757 Horizontal Economizer Ultra Low-Leak JADE Enthalpy Sensor, 43" cabinet 5 ton √ 88

0270L01753 Downflow Economizer Standard Low-Leak JADE Ethalpy Sensor 3-5 ton √ 65

0270L01755 Downflow Economizer Ultra Low-Leak JADE Ethalpy Sensor 3-5 ton √ 65

0270L01156 Downflow Economizer Standard Low-Leak JADE Dry-Bulb 3-5 ton √ 65

0270L01158 Downflow Economizer Ultra Low-Leak JADE Dry-Bulb 3-5 ton √ 65

Curbs and Restraint Clips

0221L00014 Roof Curb 14" Tall, Knocked Down 3-5 ton √ 80

0221L00015 Roof Curb 24" Tall, Knocked Down 3-5 ton √ 109

0270L01261 Hold Down Bracket Kit 3-5 ton √ 8

0270L01250 Hold Down Bracket Kit for Daikin Roofcurb 3-5 ton √ 8

0221L00019 Roof Curb 14" Tall Seismic with Hold Down Brackets, Knocked Down 3-5 ton √ 102

0221L00020Roof Curb 14" Tall Wind-Rated Hurricane with Hold Down Brackets, Welded

3-5 ton √ 140

Concentrics

0270L01602 Concentric Diffuser 24 x 48 with 16" dia collars 3-5 ton √ 32

0270L01603 Concentric Diffuser 24 x 48 with 18" dia collars 3-5 ton √ 35

0270L01335 Concentric Duct Adaptor Kit for 16" Dia. Duct 3-5 ton √ 28

0270L01338 Concentric Duct Adaptor Kit for 18" Dia. Duct 3-5 ton √ 28

Page 27: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Accessories

SS-DBH3-D www.daikinac.com 27

Field Accessory part number

Description Fits Model Sizes Field-Installed Factory-InstalledOperating

Weight (lbs)

Dampers

0270L01165 2 Position Motorized Damper 3-5 ton √ 40

0270L01166 Manual Outdoor Air Damper 3-5 ton √ 24

Hail Guard Kits

HAILGD036HE Condenser Coil Hail Guards, 39" cabinet 3-4 ton √ √

HAILGD048060HE Condenser Coil Hail Guards, 43" cabinet 5 ton √ √

High Efficiency Filters

0160L00268 High Efficiency MERV 8 Air Filter Kit - 14x20x2 (qty 4) 3-4 ton √ 4

0160L00268 High Efficiency MERV 8 Air Filter Kit - 14x20x2 (qty 2) 5 ton √ 4

0160L00270 High Efficiency MERV 8 Air Filter Kit - 20x20x2 (qty 2) 5 ton √ 4

0160L00204 High Efficiency MERV 13 Air Filter Kit - 14x20x2 (qty 4) 3-4 ton √ 4

0160L00204 High Efficiency MERV 13 Air Filter Kit - 14x20x2 (qty 2) 5 ton √ 4

0160L00201 High Efficiency MERV 13 Air Filter Kit - 20x20x2 (qty 2) 5 ton √ 4

Misc Accessories

TTBCKHE01 Through the Base Gas/Electrical 3-5 ton √ √ 1

3PMKP1 Phase Monitor Kit 3-5 ton √ √ 2

0270L01232 Burglar bars Inserts 3-5 ton √ 18

Power Exhaust

0270L01167 Power Exhaust Prop Downflow Economizer, 230 V 3-5 ton √ 57

0270L01170 Power Exhaust Prop Horizontal Economizer, 230 V 3-5 ton √ 47

Controls, Thermostats and Sensors

DT4272C Comm Touch Digital Stat w/ WiFi 4h/2c 3-6 ton √ 1

DT4273C Comm Touch Digital Stat w/ WiFi & Humidity Control 4h/2cc 3-6 ton √ 1

TSTATGAC-WS Remote indoor sensor 3-6 ton √ 1

250803400 AppStat RTU 2H/2C Econ 3-6 ton √ 1

250803600 AppStat HPU 3H/2C Econ (HP only) 3-6 ton √ 1

D4271C 4h/2c Commercial 7day Programmable Wi-Fi Capable thermostat 3-6 ton √ 1

D4272C4h/2c Commercial 7day Programmable Wi-Fi Capable Hum/dehum thermostat

3-6 ton √ 1

C7232B1022 CO2 Sensor (Duct Mtd) 3-6 ton √ 1

Note: Where multiple variations are available, the heaviest combination is listed.

Page 28: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Factory and Field Installed Options

28 www.daikinac.com SS-DBH3-D

Factory Installed Options » Non-Powered Convenience Outlet: A 120V, 15A, GFCI outlet can be installed in the unit making it easier for technicians to service other units once an electrician runs power to the outlet. Outlet shall be factory-installed and internally mounted with easily accessible 120-v female receptacle. Transformer not included for this option. Outlet shall include a field-installed “While-in-Use” cover.

» Powered Convenience Outlet: A 120V, 15A, GFCI outlet can be powered with a step-transformer built into the unit. For use when the unit is not running. When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for 208/230V units; increase by 3.75A for 460V units; and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Outlet shall be powered from main line power to the rooftop unit. Outlet shall include a field-installed “While-in-Use” cover.

» Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors can be installed in the unit. To safely identify the presence of smoke inside the air conditioning system and shutdown the blower to prevent the smoke to disperse into different zones.

» Disconnect Switch (non-fused): A disconnect switch can be installed in the unit with factory wiring complete from the switch to the unit. Please note that for air conditioner and heat pump units, the appropriate electric heat kit must be ordered along with the disconnect switch (non-fused) to be factory-installed. For models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. National Electric Code (NEC) and UL approved non-fused switch shall provide unit power shutoff. The switch shall be accessible from outside of the unit and provide local shutdown and lockout capability.

» Hinged Access Panels: Allows access to unit’s major components. Combined with latches for easy access to control box, compressor, filters and blower motor.

» Through-the-base electrical connection: Allows an easier and faster field installation through the unit basepan.

» Electromechanical Controls: Basic controls that include terminal block for unit connectivity to T-Stat.

Field Installed Options » Manual Fresh Air Damper: Manual damper package shall consist of damper, air inlet screen, and rain hood which can be preset to admit up to 25% outdoor air for year round ventilation.

» Motorized Fresh Air Damper: A two-position damper with rain hood and screen provides up to 50% outside air when the indoor fan starts and closes when the indoor fan shuts down. Consist of actuator, damper, air inlet screen, and rain hood. Damper shall close upon indoor (evaporator) fan shutoff and/or loss of power. The damper actuator shall plug into the rooftop unit’s wiring harness plug. No hard wiring shall be required.

» Power Exhaust: Power exhaust shall be used in conjunction with an integrated economizer. This accessory exhausts return air and may be used in either downflow or horizontal (duct-mounted) applications. Horizontal power exhaust shall be mounted in return ductwork. Power exhaust shall be controlled by economizer controller operation. Exhaust fans shall be energized when dampers open past the 0-100% adjustable setpoint on the economizer control.

» Horizontal Economizer: Fully modulating between 0 and 100%, contain seals that meet ASHRAE 90.1 requirements. Includes motor and dampers, minimum position settings, preset linkage, wiring harness with plug, mixed air temperature sensor, and enthalpy control. An optional duct-mounted barometric relief damper is available. An optional return enthalpy sensor is available to provide comparative or differential enthalpy control. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. Standard leak rate shall be equipped with dampers not to exceed 2% leakage at 1 in. wg pressure differential. Ultra Low Leak design meets California Title 24 section 140.4 and ASHRAE90.1 requirements for 4 cfm per sq.ft. on the outside air dampers and 10 cfm per sq. ft. on the return dampers. Shall be designed to close damper(s) during loss-of-power situations with spring return built into motor. Economizer controller shall accept a 2-10 Vdc CO2 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor air damper to provide ventilation based on the sensor input.

» Economizer controller shall be Honeywell JADE W7220 that provides:

- 2-line LCD interface screen for setup, configuration and troubleshooting.

- On-board Fault Detection and Diagnostics (FDD) that senses and alerts when the economizer is not operating properly, per California Title 24.

- Sensor failure loss of communication identification

- Automatic sensor detection

- Capabilities for use with multiple-speed indoor fan systems

- Utilize digital sensors: Dry bulb and Enthalpy

- Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed.

»

Page 29: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Factory and Field Installed Options

SS-DBH3-D www.daikinac.com 29

» Roof curbs: Full perimeter roof curb with exhaust capability providing separate air streams for energy recovery from the exhaust air without supply air contamination. Two different heights 14” and 24”, allows proper installation and structure stability. Formed galvanized steel with wood nailer strip and shall be capable of supporting entire unit weight.

» Concentric duct kits: Designed to provide a single point air distribution system with the added benefit of having directional air control.

» Restraint mounting clips: Allows for installation reinforcement for Hurricane and/or seismic events.

» C02 sensor: Sensor designed to alarm the system when the C02 levels are outside safe parameters.

» Burglar Bar Sleeves: Designed to prevent the access thru the return or supply ducting inside the unit.

» Downflow square to round adapter 18": Installed into a recessed portion of the roof curb, the concentric duct adaptor changes the orientation of the ductwork from square to round for applications utilizing that type of ducting system.

» Side discharge concentric diffuser system: The Concentric diffuser system is an all in one supply and return duct free arrangement for RTU systems. This system comes with two separate duct connections, one for a supply and another for a return.

» Remote indoor sensor: Remote sensor to monitor the temperature on zones away from the main thermostat.

» Drain pan overflow switch: Allows the controls to detect and send an alarm when there is an overflow on the drain pan.

» Freeze stat: Temperature sensing device that monitors the heat exchange to prevent the coil from freezing.

Factory and Field Installed Options » Downflow Economizer: Fully modulating between 0 and

100%, contain seals that meet ASHRAE 90.1 requirements. Includes motor and dampers, minimum position settings, a preset linkage, a wiring harness with plug, a mixed air temperature sensor, enthalpy control, and a barometric relief damper. An optional return enthalpy sensor is available to provide comparative or differential enthalpy control. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. Standard leak rate shall be equipped with dampers not to exceed 2% leakage at 1 in. wg pressure differential. Ultra Low Leak design meets California Title 24 section 140.4 and ASHRAE90.1 requirements for 4 cfm per sq.ft. on the outside air dampers and 10 cfm per sq. ft. on the return dampers. Shall be designed to close damper(s) during loss-of-power situations with spring return built into motor. Economizer controller shall accept a 2-10 Vdc C02 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor air damper to provide ventilation based on the sensor input.Economizer controller shall be Honeywell W7220 that provides:

» Economizer controller shall be Honeywell W7220 that provides:

- 2-line LCD interface screen for setup, configuration and troubleshooting.

- On-board Fault Detection and Diagnostics (FDD) that senses and alerts when the economizer is not operating properly, per California Title 24.

- Sensor failure loss of communication identification

- Automatic sensor detection

- Capabilities for use with multiple-speed indoor fan systems

- Utilize digital sensors: Dry bulb and Enthalpy

- Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed.

» Low Ambient Control: Allows cooling operation down to 35°F outdoor ambient temperature for 3 - 6 ton units.

» Phase Monitor: Phase monitor (3 phase only) shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator.

» Condenser Hail Guards: Louvered metal guards help protect the condenser coil from hail and debris; available as a field-installed options on 3 – 12½ ton units.

Page 30: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Notes

30 www.daikinac.com SS-DBH3-D

Page 31: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

Notes

SS-DBH3-D www.daikinac.com 31

Page 32: DBH Commercial - Daikin · » An optional unit powered 20 amp 115 V convenience receptacle, complete with factory mounted transformer, disconnect switch, and primary and secondary

32 www.daikinac.com SS-DBH3-D

Our continuing commitment to quality products may mean a change in specifications without notice. © 2020 • Houston, Texas • Printed in the USA.

Notes