date: location: type: project: catalogc388 3-wire flex12 c488 4-wire flex12 c588 5-wire flex12 glr...
TRANSCRIPT
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 1/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
FEATURES• High efficiency acrylic center lens features linear prisms for
high performance without pixelation• Appropriate for offices, schools, medical, and public spaces• High performance reflector with matte white paint standard• HE lumen packages available• LED modules and electrical accessible from below• Optional architecturally styled integration of daylight and
occupancy sensor(s)• QR code traceability• Compatible with Dual-Lite inverters
PH
OTO
METRY
BRO
CHU
RE
DIM
ENSIO
NAL D
RAWIN
GS
SPECTRASYN
C FAQ
NX IN
-FIXTURE SO
LUTIO
N G
UID
E
DATE: LOCATION:
TYPE: PROJECT:
CONSTRUCTION• Luminaire housing, reflectors and end caps
are die-formed code-gauge cold-rolled steel• High transmission extruded acrylic enclosed
lens features linear prisms with custom frost for high efficacy without pixelation
• All reflective surfaces are finished after fabrication with unique formula high-reflectivity matte white paint for soft, uniform indirect illumination
OPTICS• Removable lens for easy access to LED
module and electrical components
INSTALLATION• An access plate is furnished with each
luminaire for fast wiring access without the necessity to open the fixture or wireway
• Luminaire fits recessed exposed Grid ceilings (G); four integral NEC compliant T-bar clips are standard
• Can be placed in Slot Grid (SG) style ceiling with regress 3/8" above ceiling plane
• A Flange Kit (FK) accessory is available for recessed hard ceiling applications
• Surface Mount (SM) option allows placement below ceiling plane
• Cable Mount (CM) option allows suspension below ceiling plane
ELECTRICAL• 60,000 hour LEDs at L80 for reduced
maintenance
Color Tuning Technology
™
CERTIFICATIONS (CONTINUED)• DLC® (DesignLights Consortium)
Qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org.
• NX is available in U.S., Canada and Mexico. For other locations consult factory
• The DTS, Dimming Bypass Module, is for emergency circuit control loads including sensors and wireless systems CSA certified to UL 924. See page 7 for wiring diagram. Link to Dimming Bypass Module Specification sheet
• This product qualifies as a “designated country construction material” per FAR 52.225-11 Buy American-Construction Materials under Trade Agreements effective 04/03/2020. See Buy American Solutions
WARRANTY• 5 year warranty• See HLI Standard Warranty for
additional information
SPECIFICATIONSELECTRICAL (CONTINUED)• 83 CRI standard or optional 90 CRI for color
sensitive applications
CONTROLS• Optional SpectraSync™ offers two modes
of Tunable White solutions and integrates seamlessly into a variety of control systems
• NX Distributed Intelligence™ provides options for standalone and networked integrated sensor with wired or wireless connectivity for NX system deployments
TECHNOLOGY• SpectraSAFE™ is a scalable, cloud-enabled
and lighting-based wireless video security solution for interior commercial and industrial applications
CERTIFICATIONS• IC label is standard for recessed products.
Note that IC label is void if product is installed on site with a combination of both battery pack plus through wiring or for air return fixtures
• All luminaires are built to UL1598 and 2108 standards, and bear appropriate cCSAus labels
• CSA certified to UL 924 standards with battery pack or DTS (Dimming Bypass Module) options
• Damp Location label standard• Adheres to LM79, LM80, and TM21
industry standards
KEY DATA
Lumen Range 1322–4083
Wattage Range 13–32
Efficacy Range (LPW) 90–135
Reported Life (Hours) L80/60,000
CONTROL TECHNOLOGY
Built toUL 924
Standards
CATALOG #:
LCAT14 LCAT22 LCAT24
RELATED PRODUCTS
11.75"(298mm)
11.75"(298mm)
11.75"(298mm)
23.77"(604mm)
23.75"(603mm)
47.75"(1213mm)
47.75"(1213mm)
23.75"(603mm)
23.77"(604mm)
23.77"(604mm)
3.98"(101mm)
3.98"(101mm)
Grid, recessed section
See Certification Specifications
BUY AMERICANSOLUTIONS
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 2/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
ORDERING GUIDEExample: LCAT12–35MLG–ESDU
CATALOG #
DATE: LOCATION:
TYPE: PROJECT:
CATALOG #:
LCAT12 – – –Model CRI Color Temp Delivered Lumens Ceiling Type Shielding Air Function Driver
LCAT121' x 2' LED Contemporary Architectural Troffer
Blank >809 >90
30 3000K35 3500K40 4000K50 5000K2750T 2700K–5000K
SpectraSync™ Tunable White1
2765T 2700K–6500K SpectraSync™ Tunable White1
VW 1322–1730MW 1720–2181LW 2253–3047ML 2808–3794HL 2858–4083
G Grid Lay-in2
SM Surface Mount3,10
CM Cable Suspended Mount3,4
Blank Curve
R Rectangular
Blank StaticA Air Return
Side Slots
E Fixed OutputED 0–10V DimmingED1 0–10V 1% DimmingEDD 0–10V Dim-to-DarkESD Step Dimming5,7,11
LUTH Hi-lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology5,7,11
LUT5 5-Series EcoSystem LED driver5,7,11
DALIP Dali Power Bus14
–Voltage Options Control Options
U 120–277V347 347V12
ELL14 Emergency Battery Pack Installed, 1400 Lumens6,7
ELL14ST Emergency Battery Pack, 1400 Lumens, Self Test 6,7
ELL14H2 Emergency Battery Pack, 2-Hour Run Time6,7
DTS Dimming Bypass Module8
C388 3-wire Flex13
C488 4-wire Flex13
C588 5-wire Flex13
GLR Fast Blow FuseEOR End of Row (SM and CM only.
Provides end wiring access for continuous row mounting.)3
INT Intermediate (SM and CM only. Provides ends with wiring access for continuous row mounting.)3
CP Chicago PlenumSAF SpectraSAFE™ Integrated
Surveillance Lighting System 9
NX StandaloneNXS NX, PIR BT Occupancy/Daylight Sensor, Slide Mount11,12
NX Networked – WiredNXE NX, Dual SmartPORTs11,12
NXES NX, PIR BT Occupancy/Daylight Sensor, Slide Mount, Dual SmartPORTs11,12
NX Networked – WirelessNXSW NX Wireless, PIR BT Occupancy/Daylight Sensor 10,11,12
NXWE NX Wireless Enabled10,11,12
NX Networked – Wired/Wireless HybridNXSWD NX Wireless, PIR BT Occupancy/Daylight Sensor, Dual SmartPORTsNXWD NX Wireless, Dual SmartPORTsThird-Party Control OptionsODPG Occupancy and Daylight Sensors w/ Grouping, Philips SNS2007, 14,18
LV Lutron Vive Attached FCJS POWPAK Fixture Control (RF only for 0–10V drivers)7, 15,16,17,18
LVR Lutron Vive Integral Fixture Control DFCSJ-OEM-RF (RF only)7, 14,16,18
LVS Lutron Vive Integral Fixture Control DFCSJ-OEM-OCC (RF with daylight and occupancy sensing)7, 14, 16, 18
ZRE ControlScope® compatible7, 18,19
Accessories
FK12 1' × 2' Single Flange Kit (Shipped separately)
CM48Y1SC3F48 48" Cable Mount Kit for 1' wide Cable Mount fixtures, 3-wire
Notes:1 Available with ED driver and 80 CRI only2 For drywall, order G with Flange Kit Accessory3 Not available with Air Return (A) air function4 Order hanger accessories separately5 Limitations apply based on lumen packages (see Product Exceptions & Details)6 For compatibility with Dual-Lite LiteGear® inverters, contact Hubbell Lighting Representative7 Not available in 347V8 For emergency circuit control loads including sensors and wireless systems CSA certified to
UL 924. Only available with 0–10V drivers. Universal voltage only. See page 7 for wiring diagram 9 SpectraSync+NX+SAF can not be configured. Only available with NXE, NXWE or NXWD. Not
available in 347V
NX In-Fixture Control Options:10 NXSW, NXWE, NXSWD and NXWD cannot be used with surface mount versions11 NX is not available with ESD, LUTH, LUT5 or DALIP driver options12 NX combined with Spectrasync is not available in 347V13 For NX control and Flex Wire together, consult factoryThird-Party Control Options:14 LVS, LVR and ODPG only available with DALIP driver option15 Only available with ED driver option16 VIVE is a trademark of Lutron Electronics Co., Inc17 Installations controlled solely by the Lutron Pico controller require accessing the LV (Lutron FCJS)
module for commissioning after the circuit has been energized18 Not available with SpectraSync (2750T or 2765T)19 Registered trademark of Daintree Networks, used by permissionFor questions about configuration options, contact Hubbell Representative
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 3/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
Driver options listed below are available for the outputs as shown.
PRODUCT EXCEPTIONS & DETAILS
DATE: LOCATION:
TYPE: PROJECT:
DRIVER AVAILABILITY TABLEVW MW LW ML HL
E X X X X XED X X X X XED1 X X X X XEDD X X X XESD X X X XLUT5 X X XLUTH X X XDALIP X X X
347 X X X X X
CATALOG #:
CONTROLS
Philips SN
S200
EasySense Design-in G
uide
Philips EasySense Controls ODPG Sensor:
• Occupancy sensing, daylight harvesting, task tuning and grouping in one device• Standalone control or grouping to wireless switches 1
• Uses Philips field apps for on site commissioning2,3
• Ability to create scenes for various room configurations• Cost-effective solution for energy-savings and code-compliancy strategies• DLC® Qualified: Listed on the QPL for Networked Lighting Controls. Please refer to the DLC website for specific product qualifications at www.designlights.org
1 Wireless switches only compatible with ODPG Philips EasySense2 See link to Philips commssioning3 Requires android device or IR dongle. See links for phone compatiblity and IR dongle
Wireless Switch Accessories1
PESR-WH EasySense compatible wireless single rocker switch, white
PEDR-WH EasySense compatible wireless dual rocker switch, white
™
N
X Design & Application G
uide
NX Brochure
NX INTEGRATED CONTROLS REFERENCE
NX Option Sensor Networkable Scheduling Occupancy Daylight Harvesting
0–10V Dimming
On/off Control
Bluetooth® App Programming
NX Standalone
NXS NXSMP-SMI No Yes Yes Yes Yes Yes Yes
NX Networked – Wired
NXE N/A Yes Yes No No Yes Yes Requires NXBTC/R1
NXES NXSMP-SMI Yes Yes Yes Yes Yes Yes Yes
NX Networked – Wireless
NXSW NXSMP-SMI Yes Yes Yes Yes Yes Yes Yes
NXWE N/A Yes Yes No No Yes Yes No2
NX Networked – Wired/Wireless
NXSWD NXSMP-SMI Yes Yes Yes Yes Yes Yes Yes
NXWD N/A Yes Yes No No Yes Yes Requires NXBTC/R 1,2
NX Distributed Intelligence™ Lighting Controls:Supports both indoor and outdoor applications in a variety of deployment options- wired, wireless, hybrid. Integrates with and enables a wide array of luminaires including those with SpectraSync™ Color Tuning Technology.
1 NXBTC/R needs to be plugged into an available NX SmartPORT™ on the fixture network2 To program NXWE option, need to consult factory. If connected to an area controller, programming can be done from that
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 4/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
SPECTRASYNC COLOR TUNING TECHNOLOGY
Mode Kelvin Range Description
Tunable White 2700K–5000K2700K–6500K
Offers users the ability to tailor CCT to their personal preference, enhancing task visibility, material and colors or the aesthetics of the space
Color Tuning Technology
SpectraSync
N
X Solutions Guide
SpectraSync Tunable WhiteAvailable in two options: 2750T (2700K–5000K) or 2765T (2700K–6500K). Requires two 0–10V controllers, one for intensity and one for CCT. Minimum 5% dimming.
To enable scheduling and for use with NX wall control preset stations please refer to Hubbell Control Solutions NX SpectraSync technical sheet.
100%
Channel 1
Channel 2
Control Input (Vdc)
Out
put (
% o
f tot
al d
river
cur
rent
)
Color Tuning Pro�le
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%0 1 2 3 4 5 6 7 8 9 10
SpectraSync Tunable White luminaires are provided with two 0–10V circuits. The violet and grey circuit is for wiring to any qualified 0–10V controller for dimming. The violet/white and grey/white circuit is for wiring to any qualified 0–10V controller for Tunable White CCT control.
Black (HOT)White (NEUTRAL)Green (GROUND)
Violet (DIMMING +)Grey (DIMMING -)
Violet/White (WHITE TUNE +)Grey/White (WHITE TUNE -)
Controller Manufacturer DataSpectraSync Tunable White was designed to be used with sinking style dimmers (provided by others) and is compatible with: • Hubbell Control Solutions (HCS): NX Distributed Intelligence™ Room Controllers (NXRC) and In-fixture Controllers (NXFM) • Lutron: DVTV, DVSTV, and NFTV dimmers • Wattstopper: ADF120277 and CD4BL (Titan) dimmers
SpectraSync™ Color Tuning Technology:Control your space based on the needs of the application, specific activities throughout the day and preferences of the occupants with distinct SpectraSync™ Color Tuning Technologies.
CONTROLS (CONTINUED)
DATE: LOCATION:
TYPE: PROJECT:
CATALOG #:
SpectraSAFE™ Integrated Surveillance Lighting System
SpectraSAFE Brochure
Technical Features• High resolution 1080p full HD camera• 2.8mm lens / 140° field of view• IR emitter for low / no-light conditions• Multiple wiring configurations available• Supports 2-way audio communication• Supports 2.4GHz WPA-PSK/WPA2-PSK Wi-Fi• Data encrypted using AES 256 standard• Low power consumption (2-5W)• Transmissions secured using Open TLS / SSL
Software & Support• Free Android, iOS and web-based app• Versatile and supports multiple applications• Multi-tenant web-based camera application• Phone and in-app chat technical support• Scalable cloud services and video storage• Supported by a 5-year warranty
SPECTRASAFE WIRING DIAGRAM
XXXVARELEASE TO PRODUCTION02/04/20P1
4 3 2 1
AAA
B
4 3 2 1
A
B
This document contains confidential and proprietary information of AleraLighting, a division of Hubbell Lighting, Inc. (HLI). Receipt or possession ofthis document does not convey any rights to reproduce or disclose itscontents, or to make, use , or sell anything it may disclose. Reproduction,disclosure, or use of the document or its contents, without the specific writtenauthorization of HLI, may violate the intellectual property rights of HLI.
CRITICAL DIMENSIONSUNSPECIFED TOLERANCES: INCHESX.X=u0.1 X.XX=u0.03 X.XXX=u0.005FRACTIONS=u1/64 ANGULAR TOLERANCE=u2v
REV.
PART NO.FINISH:MATERIAL:
THIRD ANGLE PROJECTION
DRAWN:
DO NOT SCALE PRINTCONFORMS TO ASME Y14.5MDIMENSIONS IN [ ] IN MM
DIMENSIONS IN INCHES
CHECKED BY:
ENGINEERING:
CATALOG NO. SCALE
BSIZE DRAWING NO.
REV DATE RECORD DESN CHCK
SHT 11 SHTS
- -
93124746
93124746
P1
WD - Spectra Safevalonso 01/10/20
XXX 05/19/05
Integrated Surveillance
XXX 05/19/05
PV:1
Power Supply
Pin Connections
Pin# Single
1 VAC in (N)
5 VAC in (L)
7 +Vout
9 -Vout
9
7
1
5
SPECTRA-SAFECAMERA
HARNESS WIRINGCONNECTS TO BOTTOM OF CAMERA
SPECTRA-SAFEPOWER SUPPLY
BRN
BLU
RED
BLK
BLKRED
BLK
WHTTAG
"CAMERA POWER INPUT"
XXXVARELEASE TO PRODUCTION02/04/20P1
4 3 2 1
AAA
B
4 3 2 1
A
B
This document contains confidential and proprietary information of AleraLighting, a division of Hubbell Lighting, Inc. (HLI). Receipt or possession ofthis document does not convey any rights to reproduce or disclose itscontents, or to make, use , or sell anything it may disclose. Reproduction,disclosure, or use of the document or its contents, without the specific writtenauthorization of HLI, may violate the intellectual property rights of HLI.
CRITICAL DIMENSIONSUNSPECIFED TOLERANCES: INCHESX.X=u0.1 X.XX=u0.03 X.XXX=u0.005FRACTIONS=u1/64 ANGULAR TOLERANCE=u2v
REV.
PART NO.FINISH:MATERIAL:
THIRD ANGLE PROJECTION
DRAWN:
DO NOT SCALE PRINTCONFORMS TO ASME Y14.5MDIMENSIONS IN [ ] IN MM
DIMENSIONS IN INCHES
CHECKED BY:
ENGINEERING:
CATALOG NO. SCALE
BSIZE DRAWING NO.
REV DATE RECORD DESN CHCK
SHT 11 SHTS
- -
93124746
93124746
P1
WD - Spectra Safevalonso 01/10/20
XXX 05/19/05
Integrated Surveillance
XXX 05/19/05
PV:1
Power Supply
Pin Connections
Pin# Single
1 VAC in (N)
5 VAC in (L)
7 +Vout
9 -Vout
9
7
1
5
SPECTRA-SAFECAMERA
HARNESS WIRINGCONNECTS TO BOTTOM OF CAMERA
SPECTRA-SAFEPOWER SUPPLY
BRN
BLU
RED
BLK
BLKRED
BLK
WHTTAG
"CAMERA POWER INPUT"
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 5/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
DELIVERED LUMENS, SPECTRASYNC™ Color Tuning Technology
Shielding Lumen Output Watts
2700 3000 3500 4000 5000 6500
Lumens LPW Lumens LPW Lumens LPW Lumens LPW Lumens LPW Lumens LPW
Curve
VW 13 1454 109 1519 114 1546 116 1566 118 1618 122 1593 120MW 18 1669 95 1744 99 1775 101 1798 102 1857 106 1829 104LW 23 2561 113 2676 118 2724 121 2759 122 2850 126 2807 124ML 29 3188 111 3331 116 3391 118 3434 119 3548 123 3494 121HL 32 3430 109 3584 113 3649 115 3695 117 3817 121 3760 119
Rectangle
VW 13 1488 111 1555 116 1583 118 1603 120 1656 124 1631 122MW 18 1936 109 2023 114 2059 116 2086 117 2154 121 2122 119LW 23 2537 112 2651 117 2699 119 2733 121 2823 125 2781 123ML 29 3160 110 3302 115 3361 117 3404 118 3517 122 3464 120HL 32 3216 102 3361 106 3421 108 3465 110 3579 113 3526 112
Product Availability 80 CRILumen Package Shielding Lumens Input Watts LPWLCAT12-30VW Curve 1519 13 114LCAT12-30VWx-R Rectangle 1555 13 116LCAT12-35VW Curve 1564 13 118LCAT12-35VWx-R Rectangle 1608 13 120LCAT12-40VW Curve 1589 13 119LCAT12-40VWx-R Rectangle 1633 13 122LCAT12-50VW Curve 1730 13 130LCAT12-50VWx-R Rectangle 1676 13 125LCAT12-30MW Curve 1744 18 99LCAT12-30MWx-R Rectangle 2023 18 114LCAT12-35MW Curve 1796 18 102LCAT12-35MWx-R Rectangle 2092 18 118LCAT12-40MW Curve 1824 18 104LCAT12-40MWx-R Rectangle 2125 18 119LCAT12-50MW Curve 1986 18 113LCAT12-50MWx-R Rectangle 2181 18 123LCAT12-30LW Curve 2676 23 118LCAT12-30LWx-R Rectangle 2651 23 117LCAT12-35LW Curve 2756 23 122LCAT12-35LWx-R Rectangle 2741 23 121LCAT12-40LW Curve 2799 23 124LCAT12-40LWx-R Rectangle 2784 23 123LCAT12-50LW Curve 3047 23 135LCAT12-50LWx-R Rectangle 2858 23 126LCAT12-30ML Curve 3331 29 116LCAT12-30MLx-R Rectangle 3302 29 115LCAT12-35ML Curve 3431 29 119LCAT12-35MLx-R Rectangle 3414 29 119LCAT12-40ML Curve 3484 29 121LCAT12-40MLx-R Rectangle 3468 29 120LCAT12-50ML Curve 3794 29 132LCAT12-50MLx-R Rectangle 3560 29 124LCAT12-30HL Curve 3584 32 113LCAT12-30HLx-R Rectangle 3361 32 106LCAT12-35HL Curve 3692 32 117LCAT12-35HLx-R Rectangle 3475 32 110LCAT12-40HL Curve 3749 32 119LCAT12-40HLx-R Rectangle 3529 32 112LCAT12-50HL Curve 4083 32 129LCAT12-50HLx-R Rectangle 3624 32 115
Product Availability 90 CRILumen Package Shielding Lumens Input Watts LPWLCAT12-930VW Curve 1328 14 98LCAT12-930VWx-R Rectangle 1322 13 99LCAT12-935VW Curve 1356 14 100LCAT12-935VWx-R Rectangle 1350 13 101LCAT12-940VW Curve 1385 14 103LCAT12-940VWx-R Rectangle 1379 13 103LCAT12-950VW Curve 1476 14 109LCAT12-950VWx-R Rectangle 1469 13 110LCAT12-930MW Curve 1735 18 97LCAT12-930MWx-R Rectangle 1720 18 97LCAT12-935MW Curve 1773 18 100LCAT12-935MWx-R Rectangle 1756 18 99LCAT12-940MW Curve 1810 18 102LCAT12-940MWx-R Rectangle 1794 18 101LCAT12-950MW Curve 1928 18 108LCAT12-950MWx-R Rectangle 1911 18 107LCAT12-930LW Curve 2274 23 101LCAT12-930LWx-R Rectangle 2253 23 100LCAT12-935LW Curve 2328 23 103LCAT12-935LWx-R Rectangle 2301 23 102LCAT12-940LW Curve 2381 23 105LCAT12-940LWx-R Rectangle 2351 23 104LCAT12-950LW Curve 2515 23 111LCAT12-950LWx-R Rectangle 2504 23 111LCAT12-930ML Curve 2831 29 98LCAT12-930MLx-R Rectangle 2808 29 98LCAT12-935ML Curve 2898 29 101LCAT12-935MLx-R Rectangle 2867 29 100LCAT12-940ML Curve 2964 29 103LCAT12-940MLx-R Rectangle 2929 29 102LCAT12-950ML Curve 3131 29 109LCAT12-950MLx-R Rectangle 3120 29 108LCAT12-930HL Curve 3047 32 96LCAT12-930HLx-R Rectangle 2858 32 90LCAT12-935HL Curve 3118 32 99LCAT12-935HLx-R Rectangle 2918 32 92LCAT12-940HL Curve 3190 32 101LCAT12-940HLx-R Rectangle 2981 32 94LCAT12-950HL Curve 3369 32 107LCAT12-950HLx-R Rectangle 3175 32 100
DELIVERED LUMENS
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 6/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
13"(330.2mm)
4.63"(117.6mm)
A
AB
B
B
B
1.5"
A
A
6.44"(163.6mm)
21.31"(541.2mm)
1.81"(46mm)
1.63"(41.4mm)
25"(635mm)
4.63"(117.6mm)
11.75"(298mm)
11.75"(298mm)
11.75"(298mm)
23.77"(604mm)
23.75"(603mm)
47.75"(1213mm)
47.75"(1213mm)
23.75"(603mm)
23.77"(604mm)
23.77"(604mm)
3.98"(101mm)
3.98"(101mm)
DATE: LOCATION:
TYPE: PROJECT:
DIMENSIONS
CATALOG #:
GRID
SURFACE MOUNT OR CABLE MOUNT, STATIC ONLY
CEILING COMPATIBILITY
Grid, recessed section
Surface section (SM)
Surface Mount (SM) and Cable Mount (CM), back of housing
GRID, STATIC
GRID, AIR RETURN
For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed.
FKCR For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK12 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK12 & (1) FKCR)
Row cut out dimensions using FK12s & FKCR adapters: Width 123/8", Length [24" × (# in row)] + 3/8". Example: (24" × 2) + 3/8" = 483/8"
Flange kit cut out dimension for single unit only: 123/8" × 243/8"For hard ceiling applications, order FK12
flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance.
Type G
Side End
FK12 Flange Kit
Side End
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
* For Cable Mount a 2" x 3" access plate with (4) 7⁄8" KOs provided in place of Mounting Collar shown.
11.75"(298mm)
11.75"(298mm)
11.75"(298mm)
23.77"(604mm)
23.75"(603mm)
47.75"(1213mm)
47.75"(1213mm)
23.75"(603mm)
23.77"(604mm)
23.77"(604mm)
3.98"(101mm)
3.98"(101mm)
11.75"(298mm)
11.75"(298mm)
11.75"(298mm)
23.77"(604mm)
23.75"(603mm)
47.75"(1213mm)
47.75"(1213mm)
23.75"(603mm)
23.77"(604mm)
23.77"(604mm)
3.98"(101mm)
3.98"(101mm)
Grid, back of housing
Surface Mount:Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 3/8", provided in center channel as indicated at left, marked A.
Cable Mount:Order CM ceiling type. Use CM48Y1SC3F48 48" Cable Mount Kit for 1' wide CM trim fixtures. Mounting holes are provided in diagonal straps shown at left, marked B.
© 2020 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd • Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Page 7/7 Rev. 08/10/20COL_LCAT12_S
LCAT121' × 2' LED CONTEMPORARY ARCHITECTURAL TROFFER
PHOTOMETRY PH
OTO
METRY
DATE: LOCATION:
TYPE: PROJECT:
CATALOG #:
IES
PD
F
LCAT12-35LWG-EUPOLAR GRAPH ZONAL LUMEN SUMMARY
Zone Lumens % Luminaire0–30 733 26.60–40 1199 43.50–60 2128 77.20–90 2756 1000–180 2756 100
LUMINAIRE DATA
Test No. 16456
Description 1' x 2' LED architectural troffer with frosted linear prismed lens
Delivered Lumens 2756Watts 22.60Efficacy 122Mounting RecessedSpacing Criterion 0º = 1.19 90º = 1.30
Horiz 0-180
500
1000
0 15 30 45
90
75
60
0.0 45.0 90.0
IES
PD
F
LCAT12-35MLG-EUPOLAR GRAPH ZONAL LUMEN SUMMARY
Zone Lumens % Luminaire0–30 918 26.80–40 1497 43.60–60 2643 770–90 3431 1000–180 3431 100
LUMINAIRE DATA
Test No. 16459
Description 1' x 2' LED architectural troffer with frosted linear prismed lens
Delivered Lumens 3431Watts 28.80Efficacy 117Mounting RecessedSpacing Criterion 0º = 1.19 90º = 1.29
Horiz 0-180
600
1200
0 15 30 45
90
75
60
0.0 45.0 90.0
IES
PD
F
LCAT12-35HLG-EU
POLAR GRAPH ZONAL LUMEN SUMMARY
Zone Lumens % Luminaire0–30 980 26.60–40 1603 43.40–60 2846 77.10–90 3692 1000–180 3692 100
LUMINAIRE DATA
Test No. 16462
Description 1' x 2' LED architectural troffer with frosted linear prismed lens
Delivered Lumens 3692Watts 31.60Efficacy 117Mounting RecessedSpacing Criterion 0º = 1.19 90º = 1.31
Horiz 0-180
650
1300
0 15 30 45
90
75
60
0.0 45.0 90.0
ADDITIONAL INFORMATION
All product and company names, logos and product identifiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any affiliation with or endorsement by such respective owners.
DTS WIRING DIAGRAM (0–10V DIMMING DRIVER SHOWN)
DTS Integration G
uide
DRIVER
YELLOW (#5)
BLACK
WHITE
VIOLET
GRAY
GRAY
BLACKWHITE
BLUEWHITE / BLUE
VIOLETRED
ORANGE
SMALL YELLOW (CAP)
UTILITY POWER
EMERGENCYPOWER
TEST WHITE/BLUE Emergency NeutralBLUE Emergency LineBLACK Utility Line (Unswitched Hot)WHITE Utility NeutralRED Switched HotVIOLET DimmingGRAY Dimming