datasheet - smartmaxx dhw-plus controller
TRANSCRIPT
8/6/2019 DataSheet - SmartMaxx DHW-Plus Controller
http://slidepdf.com/reader/full/datasheet-smartmaxx-dhw-plus-controller 1/3
Tnil Sifitins
Housing Plastic, PC-ABS and PMMA
Protection type IP 20 / DIN 40050
Ambient temperature 32 - 104 °F
Size 172 x 110 x 49 mm
Installation Wall mounting, also suitablefor mounting into patch panels
Display System-monitoring for visualization of the systems, 16-segment and 7-segment display, 8 symbols forindication of the system status andoperating control lamp
Inputs 4 temperature sensors Pt1000Outputs 2 semi-conductor relays
Power supply 115 V~
Operation 3 pushbuttons at the front of thehousing
Functions Differential temperature controller withadjustable system functions. Operat-ing hours counter for the solar pump,tube collector function, thermostatfunction, pump speed control, energymetering, time-controlled thermostatfunction, drainback option and heatdump function
Bus RESOL VBus®, RS232
Power consumption < 1W
Switching capacities 1 (1) A 115 V~ (semiconductor relay)1 (1) A 115 V~ (semiconductor relay)
© 2010 SunMaxx Solar, Inc. Specifcations subject to change without notice.
producT daTa SheeT
SmtMxx dhW-pls cntll
SunMaxx Solar, Inc.
56 Broome Corp. Pkwy
Conklin NY 13748
1.877.786.6299
1.800.786.0329 fax
www.sunmaxxsolar.com
Technical Specifications
Housing Plastic, PC-ABS and PMMA
Protection Type IP 20 / DIN 40050
Ambient Temperature 32 - 104 °F (0 - 40 °C)
Size 6.77 x 4.33 x 1.93 in
(172 x 110 x 49 mm)
Installation Wall mounting, also suitable for mounting
into patch panels
Display System-monitoring for visualization of thesystems, 16-segment and 7-segment dis-
play, 8 symbols for indication of the systemstatus and operating control lamp
Inputs 4 temperature sensors Pt1000
Outputs 2 semi-conductor relays
Power Supply 115 V~
Operation 3 pushbuttons at the front of the housing
Functions Differential temperature controller with ad- justable system functions. Operating hours
counter for the solar pump, tube collectorfunction, thermostat function, pump speed
control, energy metering, time-controlled
thermostat function, drainback option, andheat dump function.
Bus RESOL VBus®, RS232Power Consumption < 1W
Switching Capacities 1 (1) A 115 V~ (semi-conductor relay)1 (1) A 115 V~ (semi-conductor relay)
Functional Overview
Max. Collector Fields 2 1
Max. Tanks 2 1
Display System-monitoringilluminated
Sensor Inputs (Temperature) 4
Relay Outputs 2
1) System Dependent
Additional Functions• Speed control
• Second ∆T-function
• 2 tank priority logic
• Thermostat function
• Energy metering 1
• Freeze protection function
• Tube collector function
• Cooling functions
• VBus®
1) System Dependent
• Drainback option
• Drainback booster option
• Heat dump function
• Real time clock (timer function)
• Min. collector temperature
adjustable
• Energy-saving switch-mode
power supply
• Celsius/Fahrenheit conversion
• Emergency shutdown functions
8/6/2019 DataSheet - SmartMaxx DHW-Plus Controller
http://slidepdf.com/reader/full/datasheet-smartmaxx-dhw-plus-controller 2/3© 2010 SunMaxx Solar, Inc. Specifcations subject to change without notice.
producT daTa SheeT, ntin
SmtMxx dhW-pls cntll
SunMaxx Solar, Inc.
56 Broome Corp. Pkwy
Conklin NY 13748
1.877.786.6299
1.800.786.0329 fax
www.sunmaxxsolar.com
8/6/2019 DataSheet - SmartMaxx DHW-Plus Controller
http://slidepdf.com/reader/full/datasheet-smartmaxx-dhw-plus-controller 3/3
approVaL STaMpS
SunMaxx Solar, Inc.
56 Broome Corp. Pkwy
Conklin NY 13748
1.877.786.6299
1.800.786.0329 fax
www.sunmaxxsolar.com
aittl Stms n rmks
cntt Stm n rmks
cntt Nt - Sign Blw