    POST STACK DATA LOADING

    First Create a Survey

    Fig1 : OW Command Menu

    In the OpenworksCommand Menu , Select

    Data > Management > Seismic Data Manager

    Fig2: Seismic Data Manager_3D Survey_General

    In the Seismic Data Manager tab , Select 3D Survey

    In 3D Survey Compute General and Grid Information

    Fig3: Seismic Data Manager_3D Survey_Grid

    Save the Survey ( Example Save as Miroli Survey)

  • 8/10/2019 Data Load Bidyut

    2/13

    Post-Stack Data Loading Using Seismic Tools

    Fig4: Using Seismic Tools

  • 8/10/2019 Data Load Bidyut

    3/13

    Fig5: OW Command Menu

    In the Openworks Command Menu , Select

    Data > Management > Seismic Tools

    Fig6: Seismic tools Command Menu

    In the Seismic Tools Menu , Select

    Seismic > Post Stack data loader > Input data:: Select SEGY and Select Parameters

    Post stack Family R5000 window > Input Data > Select Disk > Analyze

    (Before analyze check data attribute and domain type)

    Fig7

    SEGY Data Input tab will Open

  • 8/10/2019 Data Load Bidyut

    4/13

    SEG-Y Data Input Window > Select Data Media Storage as Disk > Select Analyze tab

    (Check Data Attribute, Domain, update from template etc)

    Fig8

    (SEGY analyzer window will open)

    Fig9

    In SEG-Y Analyzer Window select the Disk file name (File > Select > Select the .sgy file).

    Select start bottom to start the Analyze ..........Remember It will take some time

    Note: The data will shown in Disk File name area , then push the start bottom , it will take automatically the standard

    default segy template in Template name area /other wise select the template name from interactive SEGY analyzer

    window ( Interactive SEGY Analyzer window > Template > Select> Standard SEGY) and the start the Analyze Process

  • 8/10/2019 Data Load Bidyut

    5/13

    Fig10

    Fig:11

    Fig:12

    Fig:13

    The Analyzing Job is complete now. Now to check the template whether it is correct or any scaling factor is required

    for CDPX and CDPY value.

  • 8/10/2019 Data Load Bidyut

    6/13

    Fig14

    Go to the Interactive SEGY Analyzer window and Show EBCIDIC Text header like Iline, X line, Shot Point, CDP

    X Coordinate, CDO Y Coordinate etc.

    Compare the EBCIDIC text header and BINARY trace heard of selected data whether binary trace header are

    correct or any changes is required in In-line, X-line, Shot Point, CDP X and CDP Y Coordinate Position. The

    value of CDPX and CDPY may check carefully whether any scaling factor is required or not.

    To shoe the Binary Trace Header :: Interactive SEGY Analyzer > Trace > Header view

    Fig15

  • 8/10/2019 Data Load Bidyut

    7/13

    Fig16

    Now Check the Trace header information ( Mainly Shot point, X Cord, Y Cord, #D Line and 3D Trace :: marked in blue

    portion of Trace header view ) with EBCDIC Header Information (Which information we already got by clicking

    Interactive SEGY Analyzer tab).

    Fig:15 Fig16

    Comparison Result:

    Byte Information of Inline, X Line, CDPX and CDP Y indicated in EBCIDIC Text header is not match with Trace

    header view and also digit of CDPX and CDPY is also not correct.

    Note the header information in trace header view is showing the information from automatic selected

    Standard_SEGY format.So the template format is required modification according the original EBCIDIC data

    information.

  • 8/10/2019 Data Load Bidyut

    8/13

    SEGY Analyzer browse > Edit template :: This template is the default template named as Standard_SEGY

    intially for which wrong trace header fig 16 was shown , therefore modification and also save after this is

    required for this template. Later using this modified template we will again analyze the input seismic .sgy

    data to check whether the prvious problem byte location value of x y is showing correctly after scaling

    factor. If it is shows ok then it will (this modified saved template will be used during our input data loading.

    the standard SEGY template will open

    SeG y Analyzer window > Browse / Edit template

    Fig 17: Browse the default template, which need modification

    accordingly EBCIDIC header data and scaling factor for X and Y

    Figure18: Corrected teamplate

    named as miroli_bidyut2

  • 8/10/2019 Data Load Bidyut

    9/13

    Then save the new template after modification

    After save ----plz check whether template is change and correct binary header is given for this again the data analyze

    and check the x y factor, if it is ok, then save, your template is rready to use for data load

  • 8/10/2019 Data Load Bidyut

    10/13

    Display the correct header view ...with cheking of x y factor

  • 8/10/2019 Data Load Bidyut

    11/13

    Save the format ................ and this format is apply in template name ------------- and again analyze and see the

    differenvce

  • 8/10/2019 Data Load Bidyut

    12/13

  • 8/10/2019 Data Load Bidyut