Page 1: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

DATA CENTRE COOLING SOLUTIONSSystemair – your reliable partner in Data Centre Cooling

Air handling units

Page 2: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

2 | Data Centre Cooling Data Centre Cooling | 3

The data centre industry is growing rapidly, with ever greater focus on faster connections and more uptime. Cloud data centre traffic will grow every year, and the need for bigger online storage will drive higher and higher server capacity.

Nowadays, the term Data Centre is a common term of building for many people. However, it is important to have a clear understanding of the concept in order to be able to understand the essential role that energy savings have in this type of building.

A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized and uninterrupted. There is structured cabling, control on access and fire detection and extinction systems, among other things. This is to contain all of a company´s IT systems and equip-ment.

The huge growth in the number of users connected to the internet and the enormous increase in data has led companies to invest in Data Centres that are increasingly large in size and with greater energy density per m2. Nowadays, it is essential to have an energy efficient cooling system as savings in energy cost will largely contribute to the profitability of the Data Centre.

This application brochure outlines the important aspects to be considered when designing a Data Centre with high levels of energy efficiency, that is economical-ly sustainable and that have low environmental impact by using solutions from the Systemair group, the world leader in cooling and ventilation systems.

Systemair – your reliable partner in Data Centre Cooling

Page 3: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

4 | Data Centre Cooling Data Centre Cooling | 5

Secure high quality and save money where you can

Systemair Data centre Cooling Solutions

With more than 200 engineers and 11 R&D centres around the world, Systemair offers a wide range of robust and reliable ventilation and cooling products for all kinds and sizes of data centres – even those in the most chal-lenging climatic regions. Our products are developed to the latest standards and rigorously tested. That’s why we can guarantee that our products always deliver optimum performance.

The most energy-efficient data centres use products and innovative techniques that significantly reduce energy consumption and leave minimum carbon footprint. New legislation and directives like F-gas, Eco Design and Ashrae guidelines are driving new solutions for cooling.

The industry has been focusing on PUE as the leading metric for energy efficiency, but are now also focusing more and more on other metrics, such as TCO (Total Cost of Ownership), WUE (Water-Use Effectivness), CUE Carbon Use Effectiveness) and ERE (Energy Re-use Effectiveness) where the Data Centre can be used as a source of energy.

With the adoption of the Kyoto protocol, the European Union committed itself to a reduction of at least 20 % in CO2 emissions by 2020. In 2009, the ErP Directive (Energy related Products Directive) was signed. It is often simply referred to as the Ecodesign Directive.

Certified qualitySystemair is certified in accordance with ISO 9001, ISO 14001, ATEX and European fire safety standard EN 12101-3. Our research and development laboratories are some of the most modern in Europe; measurements are made in accordance with international standards such as AMCA and ISO.

1 %3 %4 %

4 %

15 %

14 %

15 %

5 %1 %

Switchgear and transformersLightningCoolingPDUUPSProcessorServer power supplyOther serverStorageCommunication equipment

COOLING38 %

Energy demand in data centres

Cooling represents the biggest slice of the total cost in a data centre. And with more capacity and higher density there is an increased need for energy-efficient cooling of the IT equipment.

We come across this in everyday life, for example with the phasing out of traditional light bulbs or the energy- efficiency labelling on fridges, washing machines and so on.

The Directive is mandatory in the EU. This requirement affects manufacturers of ventilation and air conditioning products. The ErP Regulation covers products that are produced in the European Economic Area, as well as those imported from other countries. Products outside the EU are not covered by the regulation.

All Systemair products affected comply with the ErP directive.

Page 4: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

6 | Data Centre Cooling Data Centre Cooling | 7

Our label Green Ventilation features products with a high energy saving potential. All products labelled with Green ventilation combine energy economy with energy efficiency.

With 57 subsidiaries in 50 countries and more than 5,200 employees we are right where you need us. Around the globe our competent and experienced engineers and sales support teams are at your service, so you can trust Systemair being your partner in helping you with comprehensive HVAC solutions and products for a super-efficient data centre in any climatic region.

Save energy – lower running cost!

Fire safety ventilation

Precision cooling

Air distribution

Spot cooling

ATEX ventilation

Free cooling fans

Direct free cooling air handling unit

Indirect free cooling air handling unit

Hydronic cooling systems

Start-up service

Page 5: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

8 | Data Centre Cooling Data Centre Cooling | 9

Taking advantage of favourable outside conditions

Free Cooling air handling units

Free cooling is a highly efficient method that uses outdoor air to cool the data centre thus considerably reducing total energy consumption. Considering ASHRAE´s regulations for IT equipment it is possible to free cool during 97-99% of the time in most of the European countries (even in really hot countries free cooling air handling units can be used in combination with DX or Chilled water cooling to

reduce the total energy consumption for cooling). If it is allowed to supply air temperature at 26-27˚C for some hours of the year, which is still within ASHRAE A1 recom-mended temperatures, it is possible to avoid any mechan-ical support cooling and just use free cooling and adiabatic support.

Systemair’s Free Cooling technology stands for it’s class leading efficiency.

Calculations based on a one year performance of 1 MW data centre in Berlin, 5+1 redundancy installation, 24˚C supply and 38˚C extract, show that the system will work with an average pPUE of 1.05 and extremely low WUE of only 0.2 l/kWh. To supply air with temperature 24˚C, me-chanical support is needed only during 3% of the time.

If it is allowed to rise supply air temperature to 27˚C (within ASHRAE recommemded temperature envelope) mechanical support won´t be needed at all.

1 MW cooling system based of IFC free cooling units during 5 years of operation will give an average energy saving of 3,870,000 kWh. In terms of money saving this is equal to approximately 464,000 € in the city of Berlin.

Indirect Free Cooling units for Data Centres

Get these benefits:• Ultra-efficient free cooling with no outside air in the

data centre

• Single stage adiabatic cooling with water recovery

• Energy-efficient EC fans reduce power consumption

• Integrated controls and sensors for easy operation

• Factory-tested

• Optional Tier 3 ready: ATS and UPS for controls as option

• Optional energy recovery module as an option

• Optional modular design for many installation options

89%120k 1,05

99%120k 1,05

98%127k 1,05

94%120k 1,05

94%120k 1,05

96%113k 1,05

97%113k 1,05

92%120k 1,05

83%131k 1,06

90%134k 1,05

96%134k 1,05

94%146k 1,05

92%166k 1,05

80%178k 1,06

100%114k 1,07

97%170k 1,05 96%

105k 1,05

96%129k 1,05

72%162k 1,07

71%145k 1,07

93%109k 1,05

98%107k 1,05

99%108k 1,05

72%120k 1,05

87%134k 1,06

68%154k 1,07

ANNUAL FREE-COOLING USAGE IN EUROPEPercentage of hours with temperatures below 19°C …………. Free-cooling Electrical Power Saving per year (kWh) ..………. Expected Mechanical pPUE ………………………………………..........

Systemair’s Geniox Data Centre units are specially designed for cooling data centre facilities, our range of indirect or direct units is for both outdoor and indoor installation. All units are modular and easy to install and maintain. The units are always delivered with controls and every unit is commissioned in our factory to ensure functionality.

Systemair’s Indirect Free Cooling units (25kW-300kW) are specially designed for energy-efficient cooling of IT equipment in data centre facilities. Most time of the year the units work with only outdoor air to cool by using a high-efficient air-to-air heat exchanger. When the out-door temperature rises an adiabatic humidifier will start to help maintain the supply air temperature. The adiabatic humidifier has a water recovery solution to ensure a low WUE and will operate with tap water quality (no need for reverse osmosis).

If the design outdoor temperature is very high, a plug and play DX package can be integrated inside the unit for fur-ther mechanical support.

Systemair’s Indirect Free Cooling will ensure a low me-chanical PUE and minimal OPEX, and also has an optional energy recovery module to obtain a good Energy Re-use Factor and ERE value.

Page 6: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

10 | Data Centre Cooling Data Centre Cooling | 11

Chillers, DX Condensers & Cooling

Perfect cooling with the highest efficiency

The hydronic system, using water as exchange fluid, pro-vides perfect cooling with high efficiency. The system is flexible and can be tailored to any type of building, meet-ing the demands of small, medium and large data centres.

Systemair offers a wide range of chillers and heat pumps that are Eurovent certified and comply with ErP directives to ensure that you have the most efficient product for your data centre.

Our range of Hydronic Cooling systems:

• Air cooled chillers and heat pumps from 5 to 1700 kW cooling power

• Water cooled chillers, heat pumps and condensing units from 20 to 1600 kW cooling power

• Free cooling modules from 100 to 550 kW cooling power

• Condensing units from 20 to 700 kW cooling power

• Roof top units from 15 to 110 kW cooling power

Systemair’s Direct Free Cooling units are built with the most efficient components available. This results in minimum operating costs and a low carbon footprint. Our units range from 50 to 300 kW cooling capacity, and use outdoor in combination with air adiabatic cooling to obtain a low OPEX.

Our units offer you several advantages:• Innovative cooling ensures low OPEX

• Energy-efficient EC fans reduce power consumption

• Efficient air filtration

• Integrated controls and sensors for easy operation

• Factory-tested

• Optional Tier 3 ready: ATS and UPS for controls as option

• Compact sizes for small spaces

Direct Free Cooling units for Data Centres

Rooftop units

Stacked unit for multi-story buildings mounted alongside the wall.

Stacked units for perimeter installation.

Wall supply cold corridor containment.

Floor supply and ducted return.

Page 7: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

SysTemp R SysTemp GSysTemp P

12 | Data Centre Cooling Data Centre Cooling | 13

SysTemp Close control cooling systems

SysTemp Cooling Range 8 - 128 kW

Systemair offer a comprehensive range of close control air conditioning units, designed to meet the requirements of environmentally sustainable development. The units of the Systemair close control air conditioning range have been optimised for use in new generation data centres, offering the highest guarantee of flexibility, efficiency and reliability.

Our SysTemp range, for DX, chilled water, free cooling or dual circuit systems can be installed as in-row, perimeter in room installation or outside data room installation.

SysTemp designed as a highly efficient and sustainable equipment and has the following features.

• Technical innovation

• Ease of use

• Flexibility of use

• Energy efficiency

• Service reliability

The wide range of models and accessories enables opti-mal confi guration of the air conditioning system. The min-imum plan dimensions and the possibility of modulating operation for all components allow development of solu-tions tailored to the actual needs of the infrastructure, as well as ensuring future expansion without high additional costs.

• SySmart – new generation control system optimizing unit control

• SysDrive - innovative management of cooling circuit ensuring operational safety

• SySpace – increased efficiency by active distribution of workload

• Dual Power - two independent cooling sources (CW+DX or DX+CW) for critical applications

• Freecooling – reduced OPEX and CO2 emissions

Optimising infrastructure

Page 8: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

14 | Data Centre Cooling Data Centre Cooling | 15

Systemair develops, produces and delivers state-of-the-art air distribution products, valves and flow rate regu-lators. Our components comply with the highest interior design requirements and make data centres more energy efficient. Quality is guaranteed by our development lab-oratory, which is one of the most modern laboratories in Europe. There we measure air volumes, throw, coanda effect, sound level and temperature sequences, so we can provide our customers with accurate data. With our prod-ucts you can optimize airflow and direct the air to where it has the greatest effect.

Air Distribution

Our range for air distribution in Data centres:

• Grilles for walls, ceiling and floor installations

• High induction diffusers

• Floor diffusers

• Variable airflow dampers for regulating and optimizing airflow

• Balancing dampers for the duct system

Air handling units for control rooms and offices

Make up units (MAH) for Data halls

Systemair MAH data centre units are specially designed to face several important requirements:

• Maintain proper pressurization of the data hall

• Maintain minimal ventilation rate

• Control the humidity level

The make up air handling unit consists of filter, energy efficient EC fans, humidifier and dehumidification system, that allows accurate temperature and humidity control of supplied air. Another important function of the units is humidity control of indoor air.

All MAH units is equipped with intelligent control system, including extended amount of inputs and outputs and wide range of communication protocols.

When looking for a low TCO in a data centre it is also cru-cial to have energy efficient ventilation and a good indoor climate in all the other areas outside the white space in a data centre. Systemair provides a full range of air handling units with cooling and heat-recovery for all areas of a data centre.

Page 9: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

16 | Data Centre Cooling Data Centre Cooling | 17

Fans

Systemair has a wide range of EC fans for use in different applications within a data centre. Our EC fans are your first choice when it comes to economical use of energy and easy demand-controlled ventilation. These fans are driven by energy-saving EC motors with built in electronic control to keep them running in the optimal operating range. They are an excel-lent solution for demand-responsive ventilation systems.

Our range of fans for Data centres: • Circular duct fans, 10-500 l/s

• Roof fans

• Box fans

• Axial fans for free cooling

• Fan arrays for free cooling

100908070605040302010

0

100 90 80 70 60 50 40 30 20 10

27,1

48,8

65,7

78,487,5

93,697,3 99,2 99,9

ENER

GY

CON

SUM

PTI

ON

(%

)

SPEED/AIR VOLUME (%)

Spot cooling

Our spot cooling systems precisely regulate temperature and humidity for sensitive technology. In data centres and mobile phone network exchanges, their continuous oper-ation reliability ensures the high availability of computer systems.

Systemair offers many options for spot cooling in data centres, for both chilled water and DX cooling. Our range consists of in-row coolers, splits, cassette cooling units, and false ceiling units to give you maximum efficiency based on your needs.

Our range for spot precision cooling:

• Cassette coolers; DX or chilled water, spot cooling 5–100 kW

• Split units for DX or chilled water, wall or floor model

• False ceiling units for DX or chilled water, 5–85 kW

During a fire, smoke and gases spread through the entire data centre. So it is essential that buildings are construct-ed to prevent the expansion of smoke and fire. Systemair has solutions for both extracting smoke through ener-gy-efficient EC fans that comply with the latest fire stan-dards, as well as fire dampers for sealing off a building compartment or duct system.

All our products are certified and tested by independent and accredited laboratories.

Fire Safety VentilationOur range of Fire Safety Ventilation: • Smoke extract fans F400 and F600 according to

EN1366-1 for roof, wall or duct installation

• Fire dampers EI90S and EI120S according to EN1366-1

ATEX certified products ( explosion proof ventilation)• Air handling unit

• Fans

• Regulation and shut-off dampers

• Fire dampers, EI120S

Page 10: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

18 | Data Centre Cooling Data Centre Cooling | 19

Kuala Lumpur, Malaysia

Skinnskatteberg, SwedenHässleholm, Sweden

Ukmergé, Lithuania

Bratislava, SlovakiaMaribor, Slovenia

Windischbuch, Germany

Madrid, Spain

Aarhus, Denmark

Waalwijk, The Netherlands

Lenexa, USA

Eidsvoll, Norway

Bouctouche, Canada

Mühlheim a.d.R., Germany

Milan, Italy Istanbul, Turkey

Langenfeld, Germany

New Delhi, India

Systemair across the worldSave Energy, lower running cost! Our label “Green Ventilation” features products with a high energy saving potential. All products labelled with “Green Ventilation” combine energy economy with energy efficiency.

Quality: Systemair is certified in accordance with ISO 9001; ISO 14001, ATEX and European fire safety standard EN 12101-3. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards such as AMCA and ISO.

Tillsonburg, Canada

Skinnskatteberg, Sweden

The Group headquarters, distribution centre and largest production site. Production of compact air handling units and a wide range of fans and accessories. Production of air curtains and fan heaters for Frico, a company within the Systemair Group.

Hässleholm, Sweden

Production of heating products for air handling units, mobile and fixed fan heaters, plus dehumidifiers.

Windischbuch, Germany

Producton of an extensive range of axial and roof fans, plus tunnel and garage ventilation.

Langenfeld, Germany

Production of air curtains.

Mühlheim an der Ruhr, Germany

Production of air handling units for swimming pool halls and comfort ventilation with extra high efficiency.

Tillières, France Production of air conditioning products.

Ukmergé, Lithuania

Production of residential units and large air handling units.

Maribor, Slovenia

Production of high-temperature fans for smo-ke extract ventilation.

Aarhus, Denmark

Production of large air handling units – ”central units”.

Bratislava, Slovakia

Production of air distribution products; fire dampers.

Hyderabad, India

Production of air distribution products.

Greater Noida, New Delhi, India

Production of duct, axial and box fans, air handling units and air distribution products.

Kuala Lumpur, Malaysia

Production of duct and axial fans.

Lenexa, USA

Production of duct, axial and roof fans chiefly for the North American market. Distribution centre for the USA market.

Milan, Italy

Production of a wide range of liquid- and air-cooled chillers and heat pumps for comfort cooling.

Madrid, Spain

Production of large air handling units and box fans for markets in southern Europe, the Middle East and North Africa.

Bouctouche, Canada

Production of air handling units for residential use in North America, plus dehumidifiers.

Tillsonburg, Canada

Production of air handling units for classroom ventilation in the North American market.

Eidsvoll, Norway

Production of air handling units.

Istanbul, Turkey

Production of a wide range of air handling units and fan coils.

Waalwijk, The Netherlands

Production of air handling units.

Hyderabad, India

Tillières, France

Page 11: DATA CENTRE COOLING SOLUTIONS - Systemair · A Data Centre is a specially conditioned space in which temperature and humid-ity are controlled, the electricity supply is stabilized

Syst

emai

r · ·

Oct

ober

201

7 · E

8287

www.systemair.com