daq system to search for grbs using water cerenkov detectors mario castillo*, gonzalo perez*,...

Download DAQ System to Search for GRBs using Water Cerenkov Detectors Mario Castillo*, Gonzalo Perez*, Humberto Salazar* and L. Villaseñor ** * Facultad de Ciencias

If you can't read please download the document

Upload: delphia-preston

Post on 16-Dec-2015

222 views

Category:

Documents


3 download

TRANSCRIPT

  • Slide 1
  • DAQ System to Search for GRBs using Water Cerenkov Detectors Mario Castillo*, Gonzalo Perez*, Humberto Salazar* and L. Villaseor ** * Facultad de Ciencias FisicoMatematicas, BUAP, Puebla ** Institute of Physics and Mathematics, University of Michoacan, Morelia VII SILAFAE CAB Bariloche, Ar January, 13-21, 2009
  • Slide 2
  • Slide 3
  • WCD array at Sierra Negra to search for GRBs
  • Slide 4
  • 4550 masl (610 g/cm2)
  • Slide 5
  • 4m 2 x 1.4 m Single 5 EMI flat PMT Tyvek Ultra pure (~20 microS) water
  • Slide 6
  • FPGA Xilinx Spartan 2E JTAG 50 Mhz Clock VP or UT Oncore GPS Receiver 50 ns Antenna 1 PPS Serial 9600 Baud PROM 4 operation modes: Trace, Charge, Rate, Muon Decay RAM 10 bit ADC board 100-200 MHz|| Schematic of the DAQ Board (one channel upgradable to 3 channels) Languages: VHDL + Perl & AWK RS232 115200 Baud 2x-4x clock Signal from PMT
  • Slide 7
  • ADC daugther boards 1 or 2 AD9214BRSZ-105 chips operating at 100MSPS.
  • Slide 8
  • We use one (two) delay-locked loop (DLL) circuits to obtain 100 (200) Mhz out of 50 MHz
  • Slide 9
  • Use a Motorola Oncore GPS receiver Use a Motorola Oncore GPS receiver in precise Timing Mode model UT+ Position-Hold option 1PPS Cable and antenna Delay Time RAIM option to isolate satellites with erroneous time measurements
  • Slide 10
  • Slide 11
  • Trace mode, samples 30 trace points every 10 ns in real time and measures charge, amplitude, baseline and STD
  • Slide 12
  • Trace Mode: Up to 180 full traces per second Bottle- neck: 115200 baud comm rate
  • Slide 13
  • Charge mode: Up to 2880 Charge & Amplitude measurements per second (1920 per s if rise time is also measured)
  • Slide 14
  • Measure Charge, Amplitude,T10-50,T10-90 with good precision for three different triggers. Arbitrary muons threshold of 30mV
  • Slide 15
  • 1.54 m diameter, 1.2 m water, one 8 PMT, tyvek 1/5 in volume of an Auger WCD
  • Slide 16
  • Slide 17
  • LabView based DAS
  • Slide 18
  • Slide 19
  • Rise time behaves similarly to Charge over amplitude
  • Slide 20
  • Charge spectrum 2000 masl 4550 masl
  • Slide 21
  • Muon decay mode: Time between consecutive pulses in a 20 microsec window and time over threshold with granularity of 5 ns
  • Slide 22
  • Stopping muon at 0.1 VEM Decay electron at 0.17 VEM Crossing muon at 1.05 VEM Alarcn M. et al., NIM A 420 [1-2], 39-47 (1999).
  • Slide 23
  • Rate mode: Number of pulses above 4 thresholds every 5 ms
  • Slide 24
  • Conclusions DAQ system prototype tested 1-3 ADC channels at 100-200 MHz Precise timing from GPS 4 operation modes: Trace, charge, muon decay and rate To do: implement as a single board