danfoss solutions for walk-in coolers and freezers€¦ · walk-in coolers and freezers. that’s...

2
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. U.S. Department of Energy (DOE) improves energy efficiency in the U.S. and Canada In the U.S., the energy conservation standard is called AWEF (Annual Walk-in Energy Factor). In Canada, Natural Resources Canada (NRCan) and the Office of Energy Efficiency have proposed to align with the U.S. standard and is called Amendment 15 to the Energy Efficiency Regulations. AFFECTED APPLICATIONS WITHIN REFRIGERATION Walk-in Coolers & Freezers (including blast chillers, process cooling and preparation rooms). ALL PRODUCTS OFFERED FROM JANUARY 1 ST 2020 Effective January 1 st , 2020, all medium temperature Condensing Units offered for sale must meet the applicable AWEF levels. ANNUAL WALK-IN ENERGY FACTOR (AWEF) AWEF – Ratio of heat removed from the envelope to the total energy input of the refrigeration system over one year. Meeting AWEF in 3 steps Benefits for everyone Standard way to measure the performance Eco-friendly products Energy consumption savings when using units with higher AWEF Coolselector®2 software provides AWEF levels when applicable Future-proof units complying with regulations U.S. DOE AWEF standards and timing Equipment Class Capacity Minimum AWEF (Btu/W-h) Enforcement Date Dedicated Condensing System - Med Indoor <9,000 Btu/h 5.61 January 2020 9,000 Btu/h 5.61 January 2020 Dedicated Condensing System - Med Outdoor < 9,000 Btu/h 7.60 January 2020 9,000 Btu/h 7.60 January 2020 Dedicated Condensing System - Low, Outdoor with a Net Capacity < 6,500 Btu/h 6.522*10 -5 *C net + 2.73 February 2020 6,500 Btu/h 3.15 February 2020 Dedicated Condensing System - Low, Indoor with a Net Capacity < 6,500 Btu/h 9.091*10 -5 *C net + 1.81 February 2020 6,500 Btu/h 2.4 February 2020

Upload: others

Post on 24-Mar-2020

17 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Danfoss Solutions for Walk-in Coolers and Freezers€¦ · walk-in coolers and freezers. That’s why we offer reliable, easy to install and service components built with market leading

AD304956870598 © Danfoss | DCS (mmg) | 2019.05

For more information on Danfoss solutions for walk-in coolers & freezers,

Call us at 1-888-DANFOSS or visit our website

danfoss.com/walk-ins

danfoss.com/walk-ins

Go Beyond Cool In Danfoss we understand the importance of highly efficient and dependable walk-in coolers and freezers. That’s why we offer reliable, easy to install and service components built with market leading expertise in refrigeration applications.

Danfoss Solutions for Walk-in Coolers & Freezers

Trustedpartner, delivering easy and reliable solutions.

Find more information at www.district-cooling.danfoss.com

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in speci�cations already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

U.S. Department of Energy (DOE) improves energy efficiency in the U.S. and CanadaIn the U.S., the energy conservation standard is called AWEF (Annual Walk-in Energy Factor). In Canada, Natural Resources Canada (NRCan) and the Office of Energy Efficiency have proposed to align with the U.S. standard and is called Amendment 15 to the Energy Efficiency Regulations.

AFFECTED APPLICATIONS WITHIN REFRIGERATION

Walk-in Coolers & Freezers (including blast chillers, process cooling and preparation rooms).

ALL PRODUCTS OFFERED FROM JANUARY 1ST 2020

Effective January 1st, 2020, all medium temperature Condensing Units offered for sale must meet the applicable AWEF levels.

ANNUAL WALK-IN ENERGY FACTOR (AWEF)

AWEF – Ratio of heat removed from the envelope to the total energy input of the refrigeration system over one year.

Meeting AWEF in 3 steps

Benefits for everyone

Standard way to measure the performance Eco-friendly products

Energy consumption savings when using units with higher AWEF

Coolselector®2 software provides AWEF levels when applicable

Future-proof units complying with regulations

U.S. DOE AWEF standards and timing

Equipment Class CapacityMinimum AWEF

(Btu/W-h)Enforcement

Date

Dedicated Condensing System - Med Indoor

<9,000 Btu/h 5.61 January 2020

≥ 9,000 Btu/h 5.61 January 2020

Dedicated Condensing System - Med Outdoor

< 9,000 Btu/h 7.60 January 2020

≥ 9,000 Btu/h 7.60 January 2020

Dedicated Condensing System - Low, Outdoor with a Net Capacity

< 6,500 Btu/h 6.522*10-5*Cnet + 2.73 ≈ February 2020

≥ 6,500 Btu/h 3.15 ≈ February 2020

Dedicated Condensing System - Low, Indoor with a Net Capacity

< 6,500 Btu/h 9.091*10-5*Cnet + 1.81 ≈ February 2020

≥ 6,500 Btu/h 2.4 ≈ February 2020

Page 2: Danfoss Solutions for Walk-in Coolers and Freezers€¦ · walk-in coolers and freezers. That’s why we offer reliable, easy to install and service components built with market leading

Go Beyond Cool by creating better solutions

Built with the contractor in mindOptyma™ Slim Outdoor Condensing Unit

Contractor-friendly designDanfoss products are built with technicians in mind. Our contractor-friendly designs allow for fast installation and easy system maintenance.

Industry expertiseDanfoss products are backed by over eighty years in the refrigeration industry so you can count on our experience.

Energy efficiencyDanfoss components are engineered to deliver the most efficient equipment operation possible, ensuring the system always runs at peak performance independent of operating conditions.

Product reliabilityOur engineers work tirelessly to ensure that our products are the highest possible quality. Installing a Danfoss part means peace of mind for you and your customers.

Wholesaler availabilityWith our wide network of distribution partners across the United States, you can get Danfoss products when and where you need them.

EVR solenoid valve

TU thermostatic expansion valve

KPU 19 thermostat Optyma™ Slim condensing unit

With industry leading quality and application expertise, Danfoss offers a powerful com-bination to maximize walk-in operation.

Whether your focus is system lifespan, efficiency, or simplified maintenance and instal-lation, Danfoss products assure that you are offering your customer the best possible solution.

Proven reliability Full product portfolio for evaporator units

Solenoid Valve EVR – The EVR is a direct or servo operated solenoid valve used for hot gas defrost or to isolate refrigerant from the compressor for start up protection. System reliability is improved by enabling lower maintenance yet the design allows quick installation and removal when necessary.

ThermostatKPU 19 – The KPU 19 temperature control is specifically designed for its easy installation and service. Contractor-friendly features include adifferential adjustment dial, a tamper-resistant design, and a robust thermoplastic housing.

Easy access electrical box

Integrated defrost time clock

Clear lift points to simplify rooftop installation

Fan Speed Controller to extend system lifespan

Rotalock valves for easy service

High quality, reliable Danfoss compressor

Easy to clean, durable microchannel coil

Filter drier and sight glass with flare connections

Voltage Danfoss Code No.

120v 018F4110

208-240v 018F4120

Solenoid CoilApplication

Condensing Unit Solenoid Valve Unit Cooler

Horsepower Danfoss ModelBTU/HR1

25°F med, -20°F Low, 90°F Amb. All R404A

Danfoss Code No.

AWEFVoltage/

PhaseTechnology Danfoss Type

Danfoss Code No.

Trenton Model

Russel Model

Bohn Model

Tecumseh Evap model

Medium Temp.

1 1/2 HJXM0150UWG000N 13,000 114N3485 7.48 230V/1 Recip EVR 3 032F1204 TLP214M A*36-120 ADT130 PLP-1070E

1 1/2 HJXM0150UWG000Q 13,000 114N3486 7.48 230V/3 Recip EVR 3 032F1204 TLP214M A*36-120 ADT130 PLP-1070E

2 HNXM0200UWG000N 19,450 114N3487 10.02 230V/1 Scroll EVR 4 032L7110 TLP320M A*46-164 ADT208 PLP-1720E

2 HNXM0200UWG000Q 19,450 114N3488 10.00 230V/3 Scroll EVR 4 032L7110 TLP320M A*46-164 ADT208 PLP-1720E

2 1/2 HNXM0250UWG000N 24,750 114N3489 9.83 230V/1 Scroll EVR 6 032L1209 TLP426M A*46*185 ADT260 PLP2150E

2 1/2 HNXM0250UWG000Q 24,750 114N3490 10.11 230V/3 Scroll EVR 6 032L1209 TLP426M A*46*185 ADT260 PLP2150E

3 HNXM0300UWG000N 26,150 114N3491 9.66 230V/1 Scroll EVR 6 032L1209 TLP426M A*56-210 ADT312 PLP2150E

3 HNXM0300UWG000Q 26,150 114N3492 10.01 230V/3 Scroll EVR 6 032L1209 TLP426M A*56-210 ADT312 PLP2150E

3 1/2 HNXM0350UWG000N 33,750 114N3493 10.67 230V/1 Scroll EVR 8 032L7121 TLP532M A*66-245 ADT370

3 1/2 HNXM0350UWG000Q 33,750 114N3494 10.92 230V/3 Scroll EVR 8 032L7121 TLP532M A*66-245 ADT370

4 HNXM0400UWG000N 38,750 114N3495 9.89 230V/1 Scroll EVR 8 032L7121 TLP639M A*66-280 BMA450SA

4 HNXM0400UWG000Q 38,750 114N3496 10.84 230V/3 Scroll EVR 8 032L7121 TLP639M A*66-280 BMA450SA

5 HRXM0500UWG000N 47,500 114N3497 10.47 230V/1 Scroll EVR 8 032L7121 TMP245M ITA36-490 BMA510SA

5 HRXM0500UWG000Q 47,500 114N3498 11.43 230V/3 Scroll EVR 8 032L7121 TMP245M ITA36-490 BMA510SA

6 HRXM0600UWG000Q 56,000 114N3499 11.28 230V/3 Scroll EVR 10 032L1217 TMP355M ITA36-620 BMA600SA

7 HRXM0700UWG000Q 60,300 114N3500 11.02 230V/3 Scroll EVR 10 032L1217 TMP368M ITA36-620 BMA600SA

7 1/2 HRXM0750UWG000Q 75,550 114N3501 10.59 230V/3 Scroll EVR 10 032L1214 TMP480M UAH4-866 BHA850SA

10 HRXM1000UWG000Q 93,800 114N3502 10.13 230V/3 Scroll EVR 15 032L1228 TMP488M UAH4-980 BHA930SA

Low Temp.

1 1/2 LJHM0150UWH000N 6,400 114N3508 - 230V/1 Recip EVR 3 032L1204 TLP206V AE24-72C LET065 PLP-640E

1 1/2 LJHM0150UWH000Q 6,400 114N3509 - 230V/3 Recip EVR 3 032L1204 TLP206V AE24-72C LET065 PLP-640E

2 LJHM0200UWH000N 9,600 114N3518 - 230V/1 Recip EVR 3 032L1204 TLP209V AE34-105C LET120 PLP-1070E

2 LJHM0200UWH000Q 9,600 114N3511 - 230V/3 Recip EVR 3 032L1204 TLP209V AE34-105C LET120 PLP-1070E

4 LNYM0400UWH000Q 15,500 114N3503 - 230V/3 Scroll EVR 4 032L7110 TLP416V AE46-164C LET160 PLP-1560E

5 LNYM0500UWH000Q 18,650 114N3504 - 230V/3 Scroll EVR 6 032L1209 TLP419V AE46-185C LET200 PLP-2150E

6 LRYM0600UWH000Q 22,550 114N3506 - 230V/3 Scroll EVR 6 032L1209 TLP523V AE66-245C LET240 PLP-2580E

8 LRYM0800UWH000Q 27,650 114N3507 - 230V/3 Scroll EVR 6 032L1209 TLP627V AE66-280C LET280

Easy Installation

Easy Service

Long Lifespan

1 Medium temperature unit capacity is based on an evaporator temperature of 25°F, return gas temperature of 65°F, and 5°F of subcooling. Low temperature unit capacity is based on an evaporator temperature of -20°F, return gas temperature of 65°F, and 5°F of subcooling.

Bulb (Contact Type) Danfoss Code No.

Remote Sensor (SPDT) 060L2150

Remote Sensor (SPST) 060L2151

Room Sensor (SPDT) 060L2152

Thermostat

Voltage Danfoss Code No.

120v 018F4180

208-240v 018F4180

Dual Voltage/Dual Frequency Coil