daikin altherma low temperature heat pump · brand newlow temperature 4 daikin altherma the new...
TRANSCRIPT
DAikin AlthermA
low temperAture
heAt pump
instAller cAtAlogue
Brand newlow temperature
4
Daikin altherma
the new DAikin AlthermA
low temperAture heAt pump,
An innovAtive proDuct rAnge,
DesigneD to Deliver only the best
in climAte control
you
p. 6
p. 14
Best seasonal eiciencies, providing the highest savings
on running costs
• excellentCOPratingsforincentiveandcertiicationschemes
• noneedfororonlyverylimiteduseofelectricalassistance• besteicienciesachievedwithinthemostrelevant
temperaturerange
perfect it for new builds,
as well as for low-energy houses
• custom-madeproductforverylowheatloads• buildtowithstandmostseverewinterconditions• heating,coolinganddomestichotwaterinonesystem
beneits4
5
p. 30
p. 22
• allcomponentsandconnectionsfactory-made• verysmallinstallationfootprintrequired• minimumelectricalinputwithconstantavailabilityofhotwater
• self-explanatorycontrollerforeasyandquickcommissioning• possibilityofpreparinganduploadingieldsettingviaaPC• feedbackonoperationconditionsandenergyconsumption
integrated heating and hot water unit, saving installation space and time
new control panel: easy to use, commission and service
Best seasonal
Withmanyyearsofair-to-waterheatpumpexperienceand over150,000unitsinstalledthroughoutEurope,wecontinuouslystrivetooptimiseDaikinAltherma’sperformance.Thisisachievedby aconstant focus on limiting electrical inputsduringeach newproduct-development-process,resultinginfurtherreducing therunningcosts.
providingthe highest savings on running costs
est seasonalprovidingtheon
7
eiciencies
8
low running costs: high heAt pump efficiencies
At All outDoor AnD wAter temperAtures
1.
Each capacity class has an individually sized compressor,dimensioned toprovideoptimal eiciencies per capacityrange.Thisavoidshavinganover-dimensionedcompressor,leadingtolowerseasonaleiciencies.For example, the compressor of the new 4kW class isdesignedtoworkatoptimalfrequencies,deliveringthelowcapacitiesneededbyhouseswithlowheatloads.
In addition to its eicient compressor range, the DaikinAltherma optimises efficiency at all outside and watertemperatureswiththeuseof:
• a pressure sensor for detailed measurement ofcondensing pressure level to evaluate the optimalamountofsubcool.
• an individual dimensioned plate heat exchanger percapacityclass,toofferoptimalefficienciesper capacityrange.
• Low-capacity 4-8kW range is equipped with swingcompressor:integrationofmainmovingpartsinonecomponent,assuringnoabrasionandnorefrigerantleakages, guaranteeing optimal reliability andeiciency;
• High-capacity11-16kWrangeisequippedwithscrollcompressors:quiet,compactandrobust,guaranteeingoptimaloperational reliability (novalvesandbuilt-inswing-link coupling) and eiciency (through a lowinitiallowandaconstantcompressionratio).
heat pump efficiency = SCop = heatingoutput/year
electricityinput/yearThetotalheatingoutputperyear isdeinedbytheclimaticconditionsandhousespeciicationsand is independent tothetypeofheatingsystem.Thetotalelectricityinputperyearisthe criticalparameterasthisiswhatthecustomerpaysfor.
Theseasonaleiciency(alsocalledSCOP)ofaheatpumpistheaverageeiciencyoverawholeyear,takingintoaccountspeciicclimaticconditionsandhousespeciications(heatload,requiredwatertemperatures,etc.).ThismeanstheSCOPvaluecanbeseenastherealoperatingeiciencyofaheatpumpsystem,takingintoaccountalltherequiredinputsandspeciicapplicationconditions.
swing scroll
DaikinAltherma low temperatureuses a rangeof efficient compressors, limitingelectrical inputs to itsmaximum. This results inoptimal eiciencies at several ratedconditions, providingexcellent ratings, complyingwithincentiveandcertiicationschemes (e.g.EPBDregulations)throughoutEurope.
9
guArAnteeD performAnces: high heAting
cApAcities Down to low outsiDe temperAture
2.
Daikin Altherma low temperature maintains its high heating capacities down to low outdoor temperatures.
Theelectricalback-upheaterassistanceisnolongerrequiredoronlyverylimited.Thesehighheatingcapacities,availableonthewholeDaikinAltherma lowtemperature4kW-16kWrange,areachievedthankstothecombinationof:
• Optimisedcontrolstoachievehigherfrequencyofuseatlowoutdoortemperatures• Liquidinjectiontoavoidtoohighdischargetemperatureswhenhighwatertemperaturesarerequired
atlowoutdoortemperatures• Perfectlydimensionedplateheatexchangerstomaximisetheheatexchangesurface
-15 -10 -5 0 5
18
16
14
12
10
8
6
4
2
0
Heatingcapacity(kW)
Outsidetemperature(°C)
less
back-up
heater
required
Back-up heater operation
typical application:
• Location:Munich• Designtemperature:-15°C• Heatload:14kW• Heatingoftemperature:16°C
A comparison is made between a standard low-temperature air-to-waterheat pump system, and the new Daikin Altherma units (ERLQ-C range – 11-16kW):
• Newrangedeliversaround3kWadditionallyat-15°C(+40%)• Equilibriumtemperatureshiftsfrom-5°Cto-10°C• Operationofelectricalassistance(BUH)isverylimited
ThisisillustratedbyatypicalapplicationinMunich
StandardheatpumpsystemERLQ016CAV3Heatload
10
minimum energy consumption: DAikin inverter
compressors with high moDulAting rAnge
3.
Whentheheatloadislowerthanthemaximumcapacityoftheheatpumpsystem,thecompressorcanturninpartialloadoperation.Thisreducedcompressorfrequencyresultsin:
• Highercompressoreiciencyinpartialloadoperation• Deliveredcapacitiesexactlymatchingtheactualheatingdemandofthebuilding• Obtainingthecapacitiesneededwithminimumenergyconsumption• Lesson/ofoperation,increasingtheoperationlifecycleofthecompressor
ThenewDaikinAlthermalowtemperaturehasahighmodulatingrange,meaningthecompressorcanmodulatedowntolowfrequenciestoofer thehighesteicienciesovertherelevanttemperaturerange.Eachinvertercompressorhasacertainmaximumandminimumfrequency,andworksinbetweentheoptimaloperationareawiththehighestoperatingeiciencies.Thisisillustratedbythegraphbellow.
Heatload>maxcapacity:fullload Compressorwilloperateat100%frequency, withadditionalelectricalassistanceifrequired
max capacity > heat load > min capacity: partial
load compressor will reduce its frequency delivering
the capacities required by the house,
with high operating efficiencies
Mincapacity>heatload:partialloadwithon/ofCompressorwillworkatitsminimumfrequencywithhighoperatingeiciencies,butswitchingon/oftodeliverthecapacitiesrequired
1
2
3
heatloadline ERLQ006CAV3maxcapacity
ERLQ006CAV3mincapacity
1 2 3-7 -5 -3 -1 1 3 5 7 9 11 13 15
8
7
6
5
4
3
2
1
0
Heatin
gcapa
city(kW)
Outdoortemperature(°C)
max frequency
wide optimal operation
area at relevant outside
temperature (-2°C to 10°C)
min frequency
optimal
operation
area
11
typical application:
• Location:Paris• Designtemperature:-7°C• Heatload:7kW• Heatingoftemperature:16°C
Efficient partial-load operation is especially important for the temperaturerangewherethehighestheatoutputisrequired.Typically,80%ofthetotalheatoutput is required in anoutdoor temperature rangeof -2°C to10°C.Achievinghigheicienciesinthistemperaturerange,contributesstronglytohighseasonaleiciencies.
• Largestpartofheatoutputdeliveredatoptimalefficiencies• Lesson/ofoperationwhenheatloadbecomeslowerthantheminimum
capacitytheheatpumpcandeliver,optimisingeiciencyandcomfort
Operationhours kWhheatoutput Taswitchof
Heatoutput(kWh)
-10 -2 0 10 20 30
HigheiciencycrucialinTarange-2C°to10°C
Heatload7kW
1600
1200
800
400
0
1000
800
600
400
200
0
Outdoortemperature(°C)
Operationhours(h)
• Modulatingrangedoubledvsstandard air-to-waterheatpumps
• Newrangedeliversaround1kWadditionalin full-loadconditionat-7°C(+25%)
-7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoortemperature(°C)
optimal
operation area
too small
8
7
6
5
4
3
2
1
0
Capa
city(kW)
-7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoortemperature(°C)
wide optimal
operation area at
relevant ta
(-2°C to 10°C)
8
7
6
5
4
3
2
1
0
Capa
city(kW)
Standard heat pump Daikin altherma
The partial load operation and optimal operation area can be illustrated by atypicalapplicationinParis
heatloadlinestandardheatpumpmaxcapacitystandardheatpumpmincapacityERLQ006CAV3maxcapacityERLQ006CAV3mincapacity
Resultinginthebestpossibleeficiencies
smArt heAting controls4.
1 Weather-dependentset-pointcontrol:DaikinAlthermamaximiseseiciencyateveryoutdoortemperaturethroughitsweather-dependentset-pointcontrol.Thiscontrollogicwillalwayskeepthewatertemperaturesaslowaspossible,tomaximisetheheatpumpeiciencyforeachspeciicoutdoortemperature.Thisresultsin:
• Higherheatpumpeiciencywithlowerwatertemperatures• Nounnecessaryoverheating,therebydeliveringthetemperaturesrequired• Continuousheatingatlowerwatertemperatures,providingstableroomtemperatures
2 Inverter technology: lowering thecompressor frequencywith increasingoutdoor temperatures, thus increasing theeiciency
Theexampleshownisforatypicalapplicationusingunder-loorheating:
• Awatertemperatureof38°Cisrequiredatadesign temperatureof-10°C(1)
• Awater temperatureofonly25°C is requiredat a spaceheatingoftemperatureof16°C(2)
• For temperaturesbetween -10°C and16°C, theDaikinAlthermaunitcalculates the required water temperature, to guarantee maximumeiciency,withcontinuousheating,ateachoutdoortemperature. -10°C 16°C
ta
1
2
Floating set-point
38°C
25°C
t set-point
(Tlwc
)
>
>The combined efect of the Daikin Altherma weather-dependent set-point control and the Daikin Altherma invertercompressorsmaximises the eiciency at each outdoor temperature, assuring stableroomtemperatures.
12
optimAl use of energy limiting electricAl inputs
of AuxiliAry components
5.
Inadditiontolimitingtheelectricalinputofthecompressorandtheelectricalback-upheater,Daikinpaysspecialattentiontolimitingelectricalinputsofauxiliarycomponents.Thisalsocontributestothehighseasonalefficienciesachievedby theDaikinAlthermarange.
• Factory-mountedhigheiciencycirculatingpumpalreadyqualifyingforfutureregulations(ErP2015)withanA-energylabel(EEI≤0.23)
• NostandbylossesofinverterdrivePCB,loweringelectricityconsumptionduringstandbymode• Nobottomplateheaterneeded on4-8kWclass• Low-capacitybottomplateheateron11-16kWclass(ERLQ-Cseries),onlyoperatingduringdefrostcycles,resultsin90%
lesselectricityconsumptionwhencomparedwithstandardthermostaticcontrolledbottomplateheaters.
=>Thankstoalltheseimprovements,COPofupto5.04*isreached
applicable units: 4-8kw
location: munich (Germany)
advantage compared
to tradional hp systemConditions
operating hours
per yearYearly beneit
Higheiciencycirculatingpump 75Wless accordingtoEN14511 5300hours 398 kwh
NostandbylossesinverterdrivePCB 20Wless instandbymode 3400hours 70 kwh
Nobottomplateheater 60Wless whenTabelow4°C 2800hours 170 kwh
applicable units: 11-16kw
location: munich (Germany)
advantage compared
to tradional hp systemConditions
operating hours
per yearYearly beneit
Higheiciencycirculatingpump 90Wless accordingtoEN14511 5300hours 477 kwh
NostandbylossesinverterdrivePCB 20Wless instandbymode 3400hours 70 kwh
Lowcapacitybottomplateheater 60Wless+smartlogic whenTabelow4°C 2800hours 160 kwh
*EHV(H/X)04CorEHB(H/X)04CwithERLQ004CV3(TaDB/WB7°C/6°C-LWC35°C(DT=5°C))
13
TheDaikinAlthermalowtemperatureisfullyoptimisedtofulill theeiciency, comfort and applicationneedsofnewlybuilthouses.Inaddition,theextendedproductrangenowoferstheperfectsolutionforlow-energyhouses,evenforverylowheatloads.
perfect it for new buildslow energy houses
as well as for
or new builds,
15
16
ThenewDaikinAlthermalowtemperatureisdesignedtomeettherequirementsofnewlybuiltandlow-energyhousescharacterisedbylowheatloads.
Thelowcapacity4kWunitwithitshighmodulatingrangeofersoptimaleiciencyinmostrelevantoutdoortemperaturerangesbycombiningcompressorsandplateheatexchangersthathavebeenspeciicalydesignedforsmallerheatloads.
optimiseD unit for low heAt loADs1.
The new-build house market in Europe is moving towardssmallerheatloads,dueto:
1. Growingimportanceoflow-energyhouses2. Strengthenedlegislationonenergyconsumptionin
newresidentialconstructions(e.g.EPBDregulations)3. Decreasingsizeofnew-buildhouses4. EUmemberstatesplanningtoreachtheir
20-20-20targets
17
heatloadlineStandardHPmaxcapacityStandardHPmincapacityERLQ006CAmaxcapacityERLQ006CAmincapacity
Outdoortemperature(°C)
optimal operation area too small
and not in relevant ta (-3°C to 7°C)
8
7
6
5
4
3
2
1
0
Capa
city(kW)
-7 -5 -3 -1 1 3 5 7 9 11 13 15 -7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoortemperature(°C)
wide optimal operation area
at relevant ta (-3°C to 7°C)
8
7
6
5
4
3
2
1
0
Capa
city(kW)
Low-energyhouseshavealowerspaceheatingoftemperature(12°C)thannormalinsulatedhouses(16°C).Thismeansthatthemostrelevantoutdoortemperature-range for low-energyhouses, shifts towards lower temperatures.A typical low-energyhouse(seedetailsbelow)has80%ofitstotalheatoutputintheoutdoortemperaturerangeof-3°Cto7°C.
Withthenew4kWunit,DaikinAlthermalowtemperatureofersafullproductline-upwithaspeciicallydimensionedheatpumpsystem(compressor,modulatingrange,plateheatexchanger,…)todelivertherequiredcapacitiesforthehouse,withthebestpossibleeiciencies.
ThenewDaikinAltherma4kWunitisdevelopedanddimensionedtoreachoptimaleicienciesatthemostrelevanttemperaturerange,thankstoitshighmodulatingrange.
typical application:
• Location:Paris• Designtemperature:-7°C• Heatload:4kW• Heatingof
temperature:12°C
Operationhours kWhheatoutput Taswitchof
-10 -5 0 5 10 15 20 25 30
HigheiciencycrucialinTarange-3C°to7°C
Heatload4kW
800
700
600
500
400
300
200
100
0
1000
900
800
700
600
500
400
300
200
100
0
Outdoortemperature(°C)
Heatoutput(kWh)Operationhours(h)
Thisisillustratedbythepracticalexamplebelow
Standard heat pump Daikin altherma
Resultinginthebestpossibleeficiencies
18
mAximum comfort2.
DaikinAltherma
lowtemperature: onesystemforoptimal year-roundcomfort
optimal comfort conditions:
Keeping the house at the desired temperature thewholeyear,withbothheatingandcoolingpossible• Only one outdoor unit required to provide heating
andcooling• Same emitters can be used for heating and cooling
(Daikinheatpumpconvectororunder-floor system)
Stable room temperatures:
The combined efect of the Daikin inverter compressorsand weather-dependent set-point control guarantees acontinuousheatingoperation.
Withhigheroutdoor temperature, thewater temperaturewill be lowered and the frequency of the compressorreduced,inordertoensureacontinuousheatingoperation,providingstableroomtemperature.
room thermostat:
TheDaikinuserinterfacecanbeinstalledinthelivingroomusingtheroomthermostatfunction,whichcanadditionallylowerorraisetheset-pointwatertemperatureinfunctionofactualroomtemperature,toevenbettermatchtheset-pointroomtemperature.
19
balancing vessel
Under-loorheating
mixingvalve
Low-temperatureradiator
45°C
35°C45°C
Under-loorheating
connectAble heAt emitters3.
25°C35°C
Heatpumpconvector 35°C45°C
TheDaikinheatpumpconvectorisspeciicallydesignedtooferoptimaleicienciesandcomfortforresidentialapplications.
• Smalldimensionscomparedtolow-temperatureradiators• Lowsoundlevel,optimalforbedroomapplications(downto19dBA)• High-capacitycoolingwithwatertemperaturesdownto6°C
Thankstothemultipleset-pointfunction,acombinationofdiferenttypesofheatemittersoperatingatdiferentwatertemperaturesispossible.Whenthereisnoheatingrequestfromthehighertemperaturezone,thewatertemperaturewill be lowered to the temperature required by thelow temperature zone. This ensures keeping the watertemperaturesaslowaspossible,whilealwaysguaranteeingthehighesteiciency.
Tset Thermostatus
Space1 low-temperatureradiator
45°C off on on off
Space2 under-loorheating
35°C off on off on
Heatpump off 45°C 45°C 35°C
TheDaikinAlthermalowtemperaturehasanoperationrangeupto55°Cleavingwatertemperature,allowingforconnectiontoalltypesoflow-temperatureheatemitters.
40°C55°CLow-temperatureradiators
new discharge grille
Free hanging coil
20
guArAnteeD operAtion: DAikin AlthermA is
suitAble for All climAtes, even withstAnDing
severe winter conDitions
4.
Daikinisrenownedfor itsknow-howrelatedtofrostprotectiononitsheatpumprange. Theoutdoorunitsarespeciicallydesignedtoavoidicebuild-upproblems,eveninthemostseverewinterconditions.
Daikin Altherma low temperature has a guaranteedoperation down to an outside temperature of -25°C.Thisensuressuicientheatpumpoperationforeventhecoldestclimates.
1.The4-8kW rangeof DaikinAlthermahasa speciicallydesignedcasingtoavoid the riskof ice formationontheoutdoorunitcoil.
• The outdoor unit has a free hanging coil, ensuring
that no ice accumulates in the lower part oftheoutdoorunit.Thisiskeytooferingappropriatefrost protection and has the additional advantagethat no electrical bottom plate heater is required.
• Thedischargegrille isalsospeciicallydesignedtoavoidiceaccumulation.
This adequate frost protection results in one productoferingthroughoutEurope,fromthesouthofSpaintothenorthofFinland.
21
hot gas pipe
2. The 11-16kW range of Daikin Altherma (ERLQ-C) hasspeciicfrostprotectiontoavoidtheriskoficeformingontheoutdoorunitcoil.
• Hotgaspass:hotgaseousrefrigerantcomingfrom
the compressor runs through the bottom platetokeepthebase freeof iceandall thedrainholes open
• Sub-cool pass: before the refrigerant pipe is splitby the distributor to the hairpins, the refrigerantpasses through the bottom of the coil to keep thislowerpartfreeofice
Only a small capacitybottomplateheater is installed(35W) on the ERLQ-C range, with smart operationlogic only operating during defrost cycles. This savesaround 90% of electricity consumption compared toatraditionalheatpumpsystemwithathermostaticallycontrolledbottomplateheater.
Sub-cool passSealing
Distributor
integrated heating and
saving installation space and time
23
ThenewDaikinAlthermalowtemperatureintegratedindoorunitis anall-in-oneloor-standingheatpumpunitincludingthedomestic hotwatertank(availablein180land260l).Thismakesittheeasiest
and fastest installationwhendomestichotwaterisrequired, andprovidesthe highest domestic hot water heating
eiciency and comfortfortheenduserinacompact,sleekdesign. Whendomestichotwaterispreferredincombinationwith theDaikinAlthermalowtemperature,the integrated indoor unit
is the best solution, for the installer and the end user!
Awall-mountedindoorunitisavailableaswell,tooferthebestsolutioninspeciicsituations,e.g.whennodomestichotwaterheatingisrequiredoracombinationwiththermalsolarenergyispreferred.
all in one
and hot water unit,
24
eAsiest AnD fAstest instAllAtion,
Domestic hot wAter tAnk incluDeD
• Thestainlesssteeldomestichotwatertank is includedin the unit, with all connections between heat pumpmodule and tank factory made. This allows for a fastinstallation compared to a traditional set-up (wall-mountedwithseparatedomestichotwater tank)withonlywaterandrefrigerantpipestobeconnected.
• All hydraulic components are included (circulatingpump,expansionvessel,back-upheater,etc.Noneedtolookforthirdpartycomponents.
• Theelectric PCBboard andhydraulic components areaccessiblefromthefront.Thisensureseasyserviceabilityand avoids the risk of any damage to electricalcomponentsduetowaterleakages.
• Allwaterandrefrigerantconnectionsareat thetopofthe unit, assuring easy connection and accessibility. This means no connections are required at the backof the unit, resulting in a lower installation footprint.
1.
Components areaccessible fromthefront
25
spAce sAving: compAct inDoor unit
with sleek Design
2.
2
Thankstotheall-in-onedesign,theinstallationspaceisminimisedbothintermsoffootprintandheight
3
4
728 mm
600 mm + 10 mm
clearance on both sides
Smallerfootprint:withawidthofonly600mmandadepthof728mm,theintegratedindoorunithasasimilarfootprintcomparedtootherhouseholdappliances.
Smallerinstallationfootprint:almostnosideclearancesarerequired,andnospaceisrequiredbehindtheunitforthepiping,asthepipingconnectionsareatthetop.Thisresultsinaninstallationfootprintofonly0.45m².
Lowinstallationheight:boththe180land260lversioncomewithaheightof173cm.Therequiredinstallationhightislessthan2m.
Thecompactnessoftheintegratedindoorunitisemphasisedbyitssleekdesignandmodernlook,easilyittingwithotherhouseholdappliances.
hydrobox
Dhw tank
VS
Compared to the traditional split-up version for a wall-mounted indoor unit and separate domestic hot water tank, theintegratedindoorunitgreatlyreducestheinstallationspacerequired.
1
600 mm
950 mm + X
1732 mm
Space reduced bymore than 30%
728 mm580mm 370mmx
26
best solution for Domestic hot wAter heAting:
high efficiency – high comfort
3.
• Heat loss from the180l tank:only1.4kWhper24h(temperaturediferenceof45°Cbetweentankandroomtemperature).
DaikinAltherma lowtemperaturecanheat thedomestichot water tank up to high tank temperatures with heatpump operation only . This avoids the use of electricalassistance forheatingup thehotwater tank,maximisingtheeiciencyofhotwaterproduction.
• Tanktemperatureupto55°Cwithheatpumponlyoperationispossible.Tanktemperaturecanbefurtherraisedto60°Cwiththestandardback-upheateroftheheatpumpmodule.
Thisresultsinhighhotwatervolumes.Followingvolumescanbeachievedwithonlyoneheat-upcycle.
• Hotwatervolumeof300lisavailableat40°C,suicientfor six showers, without any electrical assistancerequired (260l tank, tank temperature50°C,coldwatertemperature10°C,oneheat-upcycle)
• Thehotwatervolumecanbefurtherincreasedto375lusing the standard back-up heater (260l tank, tanktemperatureupto60°C).
Thedomestichotwatertankoftheintegratedindoorunitisequippedwiththickpolystyreneinsulationwhichresultsin50%lessheatlosscomparedtoastandardinsulatedtank.Thisresults inhighsavingson runningcostsas lessenergy isrequiredforthenextheat-upcycle.
27
DaikinAlthermausesasmartcontrolprincipletoheat-upthe domestic hot water tank, maximising eiciency andcomfort for the end-user.The combination of the reheatand schedule function guarantees minimum electricalinput and ensures the constant availability of hot water.
• Schedulefunction:heat-upthetankataspeciiedtimeduring theday, up to apre-set tank temperature.Thisaction can be repeated four times per day, with thepossibility of setting two diferent tank temperatures(storagecomfortandstorageeconomic.)
• Reheat function: when the tank temperature goesbelowa speciiedminimumreheat temperature,DaikinAlthermaswitchesautomaticallytodomestichotwaterheating,heatingupthetanktoaspeciiedmaximumreheattemperature.
• These two control functionalities can be usedindividually,butalsoincombinationtoprovidethebestefficiencyandmaximumcomfort.
Theschedulefunctioncanbeusedtoheatupthetankduring the night with the low electricity tarif, up to
a relatively low tank temperature (e.g. 50°C avoidingtheuseofelectricalassistance).Whenhigherhotwaterconsumptionoccursduringtheday, loweringthetanktemperature to the minimum reheat temperature, theheatpumpwillswitchautomaticallytodomestichotwaterheatingwiththereheatfunctiontoguaranteetheconstantavailabilityofhotwater.
Thankstothelargecoilsurfaceofthetank(coilsurfaceof 1.56m2) heating up the tank with the scheduledfunctionorreheatfunctionoccursveryquickly.
28
4. AlternAtive set-up: wAll-mounteD inDoor unit
incluDing All hyDrAulic components
1. when no domestic hot water is required
in combination with the Daikin altherma system
• Allhydrauliccomponentsareincludedintheheatpumpunit(circulatingpump,expansionvessel,back-upheater,etc),noneedtolookforthird-partycomponents
• All hydraulic components and the PCB board, areaccessiblefromthefrontforeasyserviceability
• Compact unit: 890 mm (height) x 480 mm (width) x 344mm(depth)
• Smallinstallationspaceasalmostnosideclearancesarerequired
• Modernoutlook easily fits inwithothermodernhouseholdappliances.
2. the wall-mounted indoor unit can be combined with
a separate domestic hot water tank
• EKHWSstainlesssteeltank:150l,200lor300l• EKHWEenameledtank:150l,200lor300l.
Thewall-mountedindoorunitistheperfectsolution,incertainsituations
29
3. when solar connection for hot water is required:
Solar collectors
Averagedover anentire year, the sundelivershalfof theenergyweneedtobringourdomestichotwateruptothedesiredtemperature.Higheiciencycollectorswithhighlyselectivecoatingtransferalltheshort-wavesolarradiationinto heat. The collectors can be mounted on roof tiles.
unpressurised thermal hot water
The solar collectors are only filled with water whensuicient heat is provided by the sun. In this case, bothpumpsinthecontrolandpumpunitswitchonbrielyandillthecollectorswithstoragetankwater.Afterilling,whichtakeslessthanaminute,oneofthepumpsswitchesofandwater circulation is maintained by the remaining pump.If there is insuicientsunshineor if thesolarstoragetankdoes not need more heat, the feed pump switches ofand the entire solar system drains into the storage tank.The addition of antifreeze is not necessary since, if theinstallationisnotinuse,thecollectorsurfacesarenotilledwithwater–anotherenvironmentaladvantage!
• EKHWPpolypropylenetank:300lor500lwithintegratedsolarpumpstation
• Higheiciencyasnoglycolisneededinthesystem• Wellinsulatedtanktominimizeheatloss• Supportforspaceheatingpossible• Improved frost protection for snow covered solar
collectors
pressurised solar system
If needed, a pressurised thermal hotwater system canalso be offered. The system is filled with heat transferfluid with the correct amount of antifreeze to avoidfreezing inwinter.Thewholesystem ispressurisedandsealed.Asolarkitandsolarpumpstationwillbeneededto connect the domestic hot water tank (EKHWS orEKHWE)tothesolarcollector.
commission and serviceeasy to use,
new control
31
TheDaikinAlthermalowtemperatureisequippedwithanewuser-interface.Commissioning,servicingandday-to-dayoperationbecomestraightforwardthemulti-lingualandgraphicalinterfacethatprovidesfull-textrepresentation,easymenunavigationandintelligent controlfeatures.
ol panel:
QUICKANDEASYCOMMISSIONING1.
Attheirststart-up,aquickconigurationwizardwillguidetheinstallerthroughthecommissioningprocess.Througha seriesof shortquestions, the set-upofbasicparameterswill automaticallybecompleted.Fine-tuning theseparametersremainspossibleusingthemenu-basednavigation.Asaresultofthequickconigurationwizard,onlytheparametersettingsrelevanttotheinstallationwillbeshowninthemenus.Theirrelevantparameterswillbehiddenandthusinaccessible.
TheparameterscanbedownloadedtoaPCasaback-up,orbeduplicatedtoothersimilarinstallations.Ifpreferred, theparametersettingscanalsobepreparedonbeforehandanduploadedtotheunitsduringcommissioning.
Before theactual test-runof theunit, anactuator testmode allowsall thewiredcomponents tobeactivatedonebyone.Thisallowsforaquickandeasycheckofallconnectionsandwiringsmadetoensureacorrectoperation.Anautomaticscreed-drying function canbeactivated toproceedthroughagradualheat-upofanUnder-loorheatingsystemtoavoidcracksintheloorduringtheirstheat-up.Individualandeasy-to-programmescheduletimers for heating, cooling, domestic hotwater operation and recirculation noise-sensitive operation and electricalboosterheaterallowtoadjusttheoperationoftheunittomatchtheend-user’stypicaldailyschedule.
Afterthecommissioning,accesstotheinstaller’smenucanberestricted(manuallyorautomaticallyafteronehour)toavoidwrongmanipulationoftheunitbytheend-user.
32
33
Graphicalscreen withbacklight
On/Of
Menuback
NavigationalbuttonsConirm
Home
Information
eAsy serviceAbility
room temperAture control functionAlity
user-frienDly with intuitive controls
2.
3.
4.
In case something goes wrong, full-text errormessageswillguidetheend-usertotakeappropriateactiontotryandresolvetheproblem.Iftheproblempersistsand a site intervention is necessary, the service engineerwillbeabletoreviewthelast20erroroccurrences.
Detailed information on the operationalconditions of theunit, suchas the runninghoursofthediferentelements,operatingtemperaturesornumberof starts, can easily be read out from the extended end-user’smenu.
TheuserinterfaceitselfisequippedwithatemperaturesensorandcanbeinstalledremotelyfromtheDaikinAlthermalowtemperatureindoorunit.
• Installedontheunit,itwillallowquickandeasyaccesstotheunit’soperatinginformationandsettings.• Installed remotely (e.g. in a living room) itwill also act as a room thermostatwithmore advanced features than
astandardroomthermostat,resultinginmorestableroomtemperatures,increasedeiciencyandoperationlifecycle.Asecondoptionalinterfacecanstillbeinstalledontheunitforservicepurposes.
Inthedetaileddisplaymode,thelargegraphicaldisplayoftheuserinterfacedisplaystheactualroomtemperatureandtheoperationmodeoftheunit.Dependingontheend-user’spreference,asimpliiedbasicdisplayisavailablethatshowsjusttheactualroomtemperatureandonlyallowstheroomtemperatureset-pointtobechanged.
Usersettingscanbeaccessedthroughanintuitiveandself-explanatorymenu.Thismenuwillalsogiveaccess to additional information such as theenergy consumption and heat production of thesystem,splitupbetweenheating,coolinganddomestichotwateroperation,enablingclosemonitoringoftheunit’seicientoperation.
34
exAmple on running cost AnD co2 compArison 1.
heat pump inpractice
Daikinprovidesaweb-basedtooltogiveaquickestimationofsavingsonrunningcostsandsavingsonCO
2emissions.
Basedonafewinputsfromthecustomer(location,housetype,loorarea,numberofpeople),acomparisonismadebetween the Daikin Altherma heat pump system and
EnergysavingscalculatorGo to ecocalc.daikin.eu and see how a Daikin AlthermaheatpumpsavesonbothrunningcostsandCO
2emission.
* Simulationforanewbuilddetachedhouse(roominroof )withlowtemperatureemitters,for4peopleandaheatedsurfaceof125m2,takingintoaccountBelgianclimateconditions,anelectricitypriceof0.17EUR/kWhandagaspriceof0.06EUR/kWh.
traditional heating systems. This comparison includesthe space heating and domestic hot water heating.This isavailable forbothnewbuildsandrefurbishmentapplications.
35
simulAtion softwAre2.
TheDaikinAlthermasimulationsoftwareprovidesforeveryspeciicapplicationandappropriateheatpumpselection,takingintoaccounttheneedsofthebuildingandspeciicclimate data. An installer can provide the following data:
• houseapplication:heat/cool load,water temperatures,powersupply
• climateconditions:location,designtemperature• domestichotwaterrequirements:tankvolume,
material,solarconnection• preferences:“heatingof“temperature,
nightsetbackfunction
Based on the speciic house and location details, thesoftware provides a full dimensioning assuring a correctmaterialselection.
Aswell as a fullmaterial selection, the softwareprovidesdetailedinformationfortheinstallerandtheend-user,onthe expected outcome of the speciied Daikin Althermaunitforitsspeciicapplicationandclimate:
• seasonaleiciencyoftheheatpumpsystem• amountofback-upheateroperation• energyconsumptionandenergycostpermonth• savings on running costs compared to traditional
heatingsystems
Allthisinformationwillbesummarisedinadetailedreport.
36
oudoor unit: 4,6,8 kw and 11,14,16 kw
heat pump convector
3. integrAtion
for A totAl solution
Whetheryouhaveanewlybuilthouseorliveinanexistinglowenergyhome,theDaikinAlthermalowtemperaturesplitallowsforcompletelyintegratedcomponentsfortotalclimatecontrol.Whetheryouoptfortheintegratedloorstanding indoor unit to provide heating and domestichotwaterorgoforawallmountedindoorunit,whetheryou use under-loor heating or heat pump convectors,whether your electricity comes from the grid or from a renewable eco-friendly resource like solar power, the Daikin Altherma low temperatureisatotalsolution4you.
37
integrated indoor unit
under-floor heating
Domestic
hot water
38
heAting only
INDOOR UNIT EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 115 116 126 120 129Operationrange Heating Ambient Min.~Max. °C -25~25 -25~25 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 42 47Soundpressurelevel Nom. dBA 28 33
OUTDOOR UNIT ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1
Heatingcapacity Min. kW 1.801/1.802 1.801/1.802 1.801/1.802 -Nom. kW 4.401/4.032 6.001/5.672 7.401/6.892 11.38 14.55 16.10Max. kW 5.121/4.902 8.351/7.952 10.021/9.352 -
Powerinput Heating Nom. kW 0.871/1.132 1.271/1.592 1.661/2.012 2.64 3.43 3.83cop 5.041/3.582 4.741/3.562 4.451/3.422 4.31 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Domestichotwater Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A R-410A
Charge kg 1.45 1.60 3.4Soundpowerlevel Heating Nom. dBA 61 62 64 66Soundpressurelevel Heating Nom. dBA 48 49 51 52
Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses A 20 40/20
heAting only
INDOOR UNIT EHVH16S18C3V EHVH16S26C9W EHVH16S18C3V EHVH16S26C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 120 129 120 129Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
OUTDOOR UNIT ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82cop 4.39 4.29 4.08 4.30 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Domestichotwater Min.~Max. °CDB -20~43 -20~43Refrigerant Type R-410A R-410A
Charge kg 3.7 2.95Soundpowerlevel Heating Nom. dBA 64 66Soundpressurelevel Heating Nom. dBA 49 51 53 51 52
Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses A 32 20
(1)coolingTa35°C-LWE18°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC35°C(DT=5°C)(2)coolingTa35°C-LWE7°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC45°C(DT=5°C)
38
1. DAikin AlthermA low temperAture
technical specifications
39
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 115 116 126 120 129Operationrange Heating Ambient Min.~Max. °C -25~25 -25~25 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 42 47Soundpressurelevel Nom. dBA 33
Heatingcapacity Min. kW 1.801/1.80 1.801/1.80 1.801/1.80 -Nom. kW 4.401/4.03 6.001/5.67 7.401/6.89 11.38 14.55 16.10Max. kW 5.121/4.90 8.351/7.95 10.021/9.35 -
Powerinput Heating Nom. kW 0.871/1.13 1.271/1.59 1.661/2.01 2.64 3.43 3.835.041/3.58 4.741/3.56 4.451/3.42 4.31 4.24 4.20
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Domestichotwater Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A R-410A
Charge kg 1.45 1.60 3.4Soundpowerlevel Heating Nom. dBA 61 62 64 66Soundpressurelevel Heating Nom. dBA 48 49 51Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses 20 40/20
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 120 129 120 129Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82
4.39 4.29 4.08 4.30 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Domestichotwater Min.~Max. °CDB -20~43 -20~43Refrigerant Type R-410A R-410A
Charge kg 3.7 2.95Soundpowerlevel Heating Nom. dBA 64 66Soundpressurelevel Heating Nom. dBA 49 51 53 51Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses 32 20
39
heAting & cooling
INDOOR UNIT EHVX04S18C3V EHVX08S18C3V EHVX08S26C9W EHVX16S18C3V EHVX16S26C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 115 117 126 121 129Operationrange Heating Ambient Min.~Max. °C -25~25 -25~25
Waterside Min.~Max. °C 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~43 10~46
Waterside Min.~Max. °C 5~22 5~22Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 42 47Soundpressurelevel Nom. dBA 28 33
OUTDOOR UNIT ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1
Heatingcapacity Min. kW 1.801/1.802 1.801/1.802 1.801/1.802 -Nom. kW 4.401/4.032 6.001/5.672 7.401/6.892w 11.38 14.55 16.10Max. kW 5.121/4.902 8.351/7.952 10.021/9.532 -
Coolingcapacity Min. kW 2.001/2.002 2.501/2.502 2.501/2.502 -Nom. kW 5.001/4.172 6.761/4.842 6.861/5.362 11.72 12.55 13.12
Powerinput Heating Nom. kW 0.871/1.132 1.271/1.592 1.661/2.012 2.64 3.43 3.83Cooling Nom. kW 1.481/1.802 1.961/2.072 2.011/2.342 4.31 5.09 5.74
cop 5.041/3.582 4.741/3.562 4.451/3.422 4.31 4.24 4.20eer 3.371/2.322 3.451/2.342 3.421/2.292 2.72 2.47 2.29Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Cooling Min.~Max. °CDB 10~43 10~46Domestichotwater Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A R-410ACharge kg 1.45 1.60 3.4
Soundpowerlevel Heating Nom. dBA 61 62 64 66Cooling Nom. dBA 63 64 66 69
Soundpressurelevel
Heating Nom. dBA 48 49 51 52
Cooling Nom. dBA 48 49 50 50 52 54Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses A 20 40/20
heAting & cooling
INDOOR UNIT EHVX16S18C3V EHVX16S26C9W EHVX16S18C3V EHVX16S26C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 1,732x600x728 1,732x600x728Weight Unit kg 121 129 121 129Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~46 10~46
Waterside Min.~Max. °C 5~22 5~22Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~60 25~60
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
OUTDOOR UNIT ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Coolingcapacity Nom. kW 10.0 12.5 13.1 11.72 12.55 13.12Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82
Cooling Nom. kW 3.69 5.38 6.04 4.31 5.09 5.74cop 4.39 4.29 4.08 4.30 4.24 4.20eer 2.71 2.32 2.17 2.72 2.47 2.29Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Cooling Min.~Max. °CDB - 10~46Domestichotwater Min.~Max. °CDB -20~43 -20~43
Refrigerant Type R-410A R-410ACharge kg 3.7 2.95
Soundpowerlevel Heating Nom. dBA - 64 66Cooling Nom. dBA - 64 66 69
Soundpressurelevel
Heating Nom. dBA 49 51 53 51 52
Cooling Nom. dBA - 50 52 54Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses A 32 20
(1)coolingTa35°C-LWE18°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC35°C(DT=5°C)(2)coolingTa35°C-LWE7°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC45°C(DT=5°C)
40
heAting only
INDOOR UNIT EHBH04C3V EHBH08C3V EHBH08C9W EHBH16C3V EHBH16C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 44 46 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~25 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 40 47Soundpressurelevel Nom. dBA 26 33
OUTDOOR UNIT ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1
Heatingcapacity Min. kW 1.801/1.802 1.801/1.802 1.801/1.802 -Nom. kW 4.401/4.032 6.001/5.672 7.401/6.892 11.38 14.55 16.10Max. kW 5.121/4.902 8.351/7.952 10.021/9.352 -
Powerinput Heating Nom. kW 0.871/1.132 1.271/1.592 1.661/2.012 2.64 3.43 3.83cop 5.041/3.582 4.741/3.562 4.451/3.422 4.31 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Domestichotwater Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A R-410A
Charge kg 1.45 1.60 3.4Soundpowerlevel Heating Nom. dBA 61 62 64 66Soundpressurelevel Heating Nom. dBA 48 49 51 52
Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses A 20 40/20
heAting only
INDOOR UNIT EHBH16C3V EHBH16C9W EHBH16C3V EHBH16C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 45 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
OUTDOOR UNIT ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82cop 4.39 4.29 4.08 4.30 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Domestichotwater Min.~Max. °CDB -20~43 -20~43Refrigerant Type R-410A R-410A
Charge kg 3.7 2.95Soundpowerlevel Heating Nom. dBA - 64 66Soundpressurelevel Heating Nom. dBA 49 51 53 51 52
Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses A 32 20
(1)coolingTa35°C-LWE18°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC35°C(DT=5°C)(2)coolingTa35°C-LWE7°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC45°C(DT=5°C)
40
41
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 44 46 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~25 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 40 47Soundpressurelevel Nom. dBA 26 33
Heatingcapacity Min. kW 1.801/1.80 1.801/1.80 1.801/1.80 -Nom. kW 4.401/4.03 6.001/5.67 7.401/6.89 11.38 14.55 16.10Max. kW 5.121/4.90 8.351/7.95 10.021/9.35 -
Powerinput Heating Nom. kW 0.871/1.13 1.271/1.59 1.661/2.01 2.64 3.43 3.835.041/3.58 4.741/3.56 4.451/3.42 4.31 4.24 4.20
Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Domestichotwater Min.~Max. °CDB -25~35 -20~35Refrigerant Type R-410A R-410A
Charge kg 1.45 1.60 3.4Soundpowerlevel Heating Nom. dBA 61 62 64 66Soundpressurelevel Heating Nom. dBA 48 49 51Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses 20 40/20
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 45 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82
4.39 4.29 4.08 4.30 4.24 4.20Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Domestichotwater Min.~Max. °CDB -20~43 -20~43Refrigerant Type R-410A R-410A
Charge kg 3.7 2.95Soundpowerlevel Heating Nom. dBA - 64 66Soundpressurelevel Heating Nom. dBA 49 51 53 51Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses 32 20
41
heAting & cooling
INDOOR UNIT EHBX04C3V EHBX08C3V EHBX08C9W EHBX16C3V EHBX16C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 44 46 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~25 -25~35
Waterside Min.~Max. °C 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~43 10~46
Waterside Min.~Max. °C 5~22 5~22Domestichotwater
Ambient Min.~Max. °CDB -25~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 40 47Soundpressurelevel Nom. dBA 26 33
OUTDOOR UNIT ERLQ004CV3/CW1 ERLQ006CV3/CW1 ERLQ008CV3/CW1 ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1
Heatingcapacity Min. kW 1.801/1.802 1.801/1.802 1.801/1.802 -Nom. kW 4.401/4.032 6.001/5.672 7.401/6.892 11.38 14.55 16.10Max. kW 5.121/4.902 8.351/7.952 10.021/9.532 -
Coolingcapacity Min. kW 2.001/2.002 2.501/2.502 2.501/2.502 -Nom. kW 5.001/4.172 6.761/4.842 6.861/5.32 11.72 12.55 13.12
Powerinput Heating Nom. kW 0.871/1.132 1.271/1.592 1.661/2.012 2.64 3.43 3.83Cooling Nom. kW 1.481/1.802 1.961/2.072 2.011/2.342 4.31 5.09 5.74
cop 5.041/3.582 4.741/3.562 4.451/3.422 4.31 4.24 4.20eer 3.371/2.322 3.451/2.342 3.421/2.292 2.72 2.47 2.29Dimensions Unit HeightxWidthxDepth mm 735x832x307 1,345x900x320Weight Unit kg 54 56 113/114Operationrange Heating Min.~Max. °CWB -25~25 -25~35
Cooling Min.~Max. °CDB 10~43 10~46Domestichotwater Min.~Max. °CDB -25~35 -20~35
Refrigerant Type R-410A R-410ACharge kg 1.45 1.60 3.4
Soundpowerlevel Heating Nom. dBA 61 62 64 66Cooling Nom. dBA 63 64 66 69
Soundpressurelevel
Heating Nom. dBA 48 49 51 52
Cooling Nom. dBA 48 49 50 50 52 54Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 V3/1~/50/230//W1/3N~/50/400Current Recommendedfuses A 20 40/20
heAting & cooling
INDOOR UNIT EHBX16C3V EHBX16C9W EHBX16C3V EHBX16C9W
Casing Colour White WhiteMaterial Precoatedsheetmetal Precoatedsheetmetal
Dimensions Unit HeightxWidthxDepth mm 890x480x344 890x480x344Weight Unit kg 45 48 45 48Operationrange Heating Ambient Min.~Max. °C -25~35 -25~35
Waterside Min.~Max. °C 15~55 15~55Cooling Ambient Min.~Max. °CDB 10~46 10~46
Waterside Min.~Max. °C 5~22 5~22Domestichotwater
Ambient Min.~Max. °CDB -20~35 -20~35Waterside Min.~Max. °C 25~80 25~80
Soundpowerlevel Nom. dBA 47 47Soundpressurelevel Nom. dBA 33 33
OUTDOOR UNIT ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1
Heatingcapacity Nom. kW 11.2 14.0 16.0 11.32 14.50 16.05Coolingcapacity Nom. kW 10.0 12.5 13.1 11.72 12.55 13.12Powerinput Heating Nom. kW 2.55 3.26 3.92 2.63 3.42 3.82
Cooling Nom. kW 3.69 5.38 6.04 4.31 5.09 5.74cop 4.39 4.29 4.08 4.30 4.24 4.20eer 2.71 2.32 2.17 2.72 2.47 2.29Dimensions Unit HeightxWidthxDepth mm 1,170x900x320 1,345x900x320Weight Unit kg 103 108Operationrange Heating Min.~Max. °CWB -20~35 -20~35
Cooling Min.~Max. °CDB - 10~46Domestichotwater Min.~Max. °CDB -20~43 -20~43
Refrigerant Type R-410A R-410ACharge kg 3.7 2.95
Soundpowerlevel Heating Nom. dBA - 64 66Cooling Nom. dBA - 64 66 69
Soundpressurelevel
Heating Nom. dBA 49 51 53 51 52
Cooling Nom. dBA - 50 52 54Powersupply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3N~/50/400Current Recommendedfuses A 32 20
(1)coolingTa35°C-LWE18°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC35°C(DT=5°C)(2)coolingTa35°C-LWE7°C(DT=5°C);heatingTaDB/WB7°C/6°C-LWC45°C(DT=5°C)
42
STaINLESS STEEL DOmESTIC HOT WaTER TaNk EkHWS150B3V3 EkHWS200B3V3 EkHWS300B3V3 EkHWS200B3Z2 EkHWS300B3Z2
CasingColour NeutralwhiteMaterial Epoxy-coatedmildsteel
Weight Unit Empty kg 37 45 59 45 59
TankWatervolume l 150 200 300 200 300Material Stainlesssteel(DIN1.4521)Maximumwatertemperature °C 85
HeatexchangerQuantity 1Tubematerial DuplexsteelLDX2101
Boosterheater Capacity kW 3Powersupply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400
ENamELED STEEL DOmESTIC HOT WaTER TaNk EkHWE150a3V3 EkHWE200a3V3 EkHWE300a3V3 EkHWE200a3Z2 EkHWE300a3Z2
CasingColour RAL9010Material Epoxycoatedsteel
Weight Unit Empty kg 80 104 140 104 140
TankWatervolume l 150 200 300 200 300Material Enamelcoatedsteelacc.DIN4753TL2Maximumwatertemperature °C 75
Boosterheater Capacity kW 3.0Powersupply Phase/Frequency/Voltage Hz/V 1~/50/230 2~/50/400
Domestic hot wAter tAnk
Domestic hot wAter tAnk for unpressurizeD solAr connection
DOmESTIC HOT WaTER TaNk EkHWP300B EkHWP500B
Casing Material ImpactresistantpolypropyleneWeight Unit Empty kg 59 92
Heatexchanger
Domestichotwater
Tubematerial Stainlesssteel(DIN1.4404)Facearea m² 5.7 5.9Internalcoilvolume l 27.8 28.4Operatingpressure bar 6Averagespecifcthermaloutput W/K 2,795 2,860
Charging
Tubematerial Stainlesssteel(DIN1.4404)Facearea m² 2.5 3.7Internalcoilvolume l 12.3 17.4Averagespecifcthermaloutput W/K 1,235 1,809
Auxiliarysolarheating
Tubematerial Stainlesssteel(DIN1.4404)Facearea m² - 1.0Internalcoilvolume l - 5
Averagespecifcthermaloutput W/K - 313Powersupply Phase -
TankWatervolume l 300 500Maximumwatertemperature °C 85
SOLaR CONNECTION EkSOLHWaV1
Dimensions Unit HeightxWidthxDepth mm 770x305x270Weight Unit kg 8
Operationrange Outdoortemperature Min.~Max. °C 1~35Soundpressurelevel Nom. dBA 27
Thermalperformance Zerolosscollectorefficiencyη0 % -Powersupply Phase/Frequency/Voltage Hz/V 1~/50/220-240Powersupplyintake Indoorunit
aCCESSORY EkSR3Pa
Mounting OnwallDimensions Unit HeightxWidthxDepth mm 332x230x145Thermalperformance Zerolosscollectorefficiencyη0 % -
ControlType DigitaltemperaturedifferencecontrollerwithplaintextdisplayPowerconsumption w 2
Sensor
Solarpaneltemperaturesensor Pt1000Storagetanksensor ptc
Returnflowsensor ptc
Feedtemperatureandflowsensor Voltagesignal(3.5VDC)Powersupply Frequency/Voltage Hz/V 50/230
solAr connection - pressurizeD system
SOLaR CONNECTION EkSRPS3
Dimensions Unit HeightxWidthxDepth mm -
ControlType DigitaltemperaturedifferencecontrollerwithplaintextdisplayPowerconsumption w -
Mounting Onsideoftank
Sensor
Solarpaneltemperaturesensor Pt1000Storagetanksensor ptc
Returnflowsensor ptc
Feedtemperatureandflowsensor Voltagesignal(3.5VDC)
solAr connection - unpressurizeD system
Note:greycellscontainpreliminarydata
43
SOLaR COLLECTOR EkSV26P EkSH26P
Dimensions Unit HeightxWidthxDepth mm 2,000x1,300x85 1,300x2,000x85Weight Unit kg 43Volume l 1.7 2.1
SurfaceOuter m² 2.601Aperture m² 2.364Absorber m² 2.354
Coating Micro-therm(absorptionmax.96%,Emissionca.5%+/-2%)Absorber Harp-shapedcopperpiperegisterwithlaser-weldedhighlyselectivecoatedaluminiumplateGlazing Singlepanesafetyglass,transmission+/-92%Allowedroofangle Min.~Max. ° 15~80Operatingpressure Max. bar 6Standstilltemperature Max. °C 200
Thermalperformance
Zerolosscollectorefficiencyη0 % 78.7Heatlosscoefficienta1 W/m².K 4.270Temperaturedependenceoftheheatlosscoefficienta2 W/m².K² 0.0070Thermalcapacity kJ/K 6.5Incidentanglemodifier AMat50° 0.94
Installedposition Vertical Horizontal
solAr collector
WIRELESS ROOm THERmOSTaT EkRTR1
DimensionsThermostat Height/Width/Depth mm 87/125/34Receiver Height/Width/Depth mm 170/50/28
WeightThermostat g 210Receiver g 125
Outsidetemperature
Storage Min./Max. °C -20/60Operation Min./Max. °C 0/50
Temperaturesettingrange
Heating Min./Max. °C 4/37Cooling Min./Max. °C 4/37
Clock YesRegulationfunction Proportionalband
Powersupply
Thermostat Voltage v Batterypowered3xAA-LRG(alkaline)Receiver Voltage v 230Frequency Hz 50Phase 1~
ConnectionThermostat WirelessReceiver Wired
Maximumdistancetoreceiver
Indoor m approx.30mOutdoor m approx.100m
WIRED ROOm THERmOSTaT EkRTWa
Dimensions Unit Height/Width/Depth mm 87/125/34Weight Unit g 215Outdoortemperature
Storage Min./Max. °C -20/60Operation Min./Max. °C 0/50
Temperaturesettingrange
Heating Min./Max. °C 4/37Cooling Min./Max. °C 4/37
Clock YesRegulationfunction ProportionalbandPowersupply Voltage v Batterypowered3*AA-LR6(alkaline)Connection Type Wired
room thermostAt
INDOOR UNITS FWXV20aVEB FWXV15aVEB
Heatingcapacity Totalcapacity Nom. kW 2.0 1.5
CoolingcapacityTotalcapacity Nom. kW 1.7 1.2Sensiblecapacity Nom. kW 1.4 0.98
PowerinputHeating Nom. kW 0.015 0.013Cooling Nom. kW 0.015 0.013
Dimensions Unit Height/Width/Depth mm 600/700/210Weight Unit kg 15Pipingconnections Drain/OD/Inlet/Outlet mm/inch 18/G1/2/G1/2Soundpressurelevel
Heating Nom. dBA 29 19Cooling Nom. dBA 29 19
Powersupply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
heAt pump convector
(1)Cooling: indoor temp. 27°CDB, 19°CwB; entering water temp. 7°C, water temperature rise 5k.(2)heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5k.
Dimensions Unit HeightxWidthxDepth mm 770x305x270Weight Unit kgOperationrange Outdoortemperature Min.~Max. °C 1~35Soundpressurelevel Nom. dBAThermalperformance Zerolosscollectorefficiencyη0 % -Powersupply Phase/Frequency/Voltage Hz/V 1~/50/220-240Powersupplyintake Indoorunit
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Daikinproductsaredistributedby:
fsc
ECPEN13-724_P
Daikin’s unique position as a manufacturer of airconditioning equipment, compressors and refrigerantshasledtoitscloseinvolvementinenvironmentalissues.ForseveralyearsDaikinhashadtheintentiontobecomea leader in the provision of products that have limitedimpact on the environment. This challenge demandsthe eco design and development of a wide rangeof products and an energy management system,resulting in energy conservation and a reduction ofwaste.
ECPEN13-724_P
•XX
X•01/13•Co
pyrig
htDaikin
Thepresen
tpub
licationsupe
rsed
esECP
EN12-724
Printedon
non
-chlorinated
pap
er.Prepa
redbyl
a m
ov
ida
, Belgium
Resp.Ed.:D
aikinEurope
N.V.,Z
andvoo
rdestraat3
00,B-8400Oostend
e
Daikin Europe N.V. participates in the EuroventCertification programme for Air conditioners(AC), Liquid Chilling Packages (LCP) and Fan coilUnits (FCU), Check ongoing validity of certificateonline: www.eurovent-certification.com or using: www.certiflash.com
The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. hascompiledthecontentofthisleaflettothebestofitsknowledge.Noexpressorimpliedwarranty is given for the completeness, accuracy, reliability or fitnessforparticularpurposeof its content and theproducts and servicespresentedtherein.Specificationsaresubjecttochangewithoutpriornotice.DaikinEuropeN.V.explicitlyrejectsanyliabilityforanydirectorindirectdamage,inthebroadestsense,arisingfromorrelatedtotheuseand/orinterpretationofthisleaflet.AllcontentiscopyrightedbyDaikinEuropeN.V.
Daikin altherma is the market creator of
the air-to-water heat pump business
• irstinverter-drivensplitlow-temperatureheatpumpsystem• irstheatpumpsystemfortruehigh-temperatureapplications• first inverter-driven split heat pump system for apartment and
commercialapplications• full range of heating solutions for any kind of application, including
solar collectors, domestic hot water tanks, under-floor heating, heatpumpconvectoretc.
Daikin altherma is the reference
on quality and reliability
• 50yearsofheatpumpexperience• 6yearsofair-to-waterheatpumpexperience• Daikin Altherma is the most sold air-to-water heat pump system
throughoutEurope,withover150,000systemssold
a clean environment
In producing your customer’s climate-control system, we strive forsustainable energy consumption, product recycling and waste reduction.Daikinrigorouslyappliestheprinciplesofeco-design,thusrestrictingtheuseofmaterialsthatareharmfultoourenvironment.
Daikin altherma
&Daikin in general
Daikin is known worldwide as
one of the biggest aC players,
with a wide product range
for residential, commercial and
industrial applications
Today, Daikin leads the way towards more efficient, cost-effective and environmentally friendly comfort solutions, introducingproducts optimised for all seasons. In fact, Daikin products reduce energy and costs in a smart way. They are designed toperform under all conditions and reflect the actual performance you can expect over an entire heating and cooling season. So,withDaikinyoumaketherightchoiceforyourwallet...andtheenvironment.