d205 mvb interfaces development board - duagon ag · d205 mvb interfaces development board ... x1...

20
www.duagon.com duagon AG Riedstrasse 12 CH-8953 Dietikon Phone +41 44 743 73 00 Fax +41 44 743 73 15 D205 MVB interfaces development board Data Sheet The D205 is a development board for two duagon MVB interfaces (D013 and D015) with serial connection. It allows a fast start with D013 and D015 integration. It is intended for laboratory use only.

Upload: lamliem

Post on 12-May-2018

374 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

www.duagon.com

duagon AGRiedstrasse 12CH-8953 DietikonPhone +41 44 743 73 00Fax +41 44 743 73 15

D205MVB interfacesdevelopment boardData Sheet

The D205 is a development board for two duagon MVB interfaces (D013 and D015) with serial connection. It allows a fast start with D013 and D015 integration. It is intended for laboratory use only.

Page 2: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

duagon Data Sheet Preamble

On having purchased products described in this data sheet, the customer acquires the right to use the products according to its specified purpose and in accordance with all operation, service and maintenance instructions. All other rights to the product, duagon's intangible assets rights in particular, belong solely to duagon andmay not be deemed to have been assigned along with the sale of the products.

All product properties are fully described in the data sheet under express exclusion of any warranty for other properties. Of decisive relevance is the data sheet valid at the time of the order being placed. duagon provides a warranty that the product properties are retained during the period of warranty. Evidence that the properties of the product have been retained will be brought, always and exclusively, on duagon premises by means of a test construction pursuant to the type test.

The customer is obliged to inspect whether the products themselves are suitable forthe application intended. In particular, that inspection must include the integration of the products into the intended system configuration and a check on whether the properties as per data sheet can be fulfilled once integrated into the system configuration as planned by the customer. Since the products are not certificated for operation with security applications, the customer must take appropriate measures to ensure that any malfunctions that may occur in a system configuration with other products will be absorbed by supplementary security measures.

The period of warranty for the products is 24 months and it begins on the date the products are shipped from the factory.

The warranty that duagon assumes for the products will, at duagon's discretion, be limited either to the repair of or the replacement of the products at the duagon factory. The warranty solely covers the products or parts thereof which, despite professional handling, have become defective or unusable and which arrive at the duagon factories for repair or replacement during the period of warranty. The extentof duagon's warranty is fully set out in this data sheet. duagon cannot be held liable for consequential damage caused by a defect or for indirect damage or for consequential damage of any kind. Therefore the customer bears all and any costs that occur due to production downtime, for example, or due to the installation or dismantling of products or due to their transportation to duagon and back.

duagon's liability and warranty do not obtain if evidence cannot be brought that theproducts were being operated according to its specified purpose and in accordance with all operation, service and maintenance instructions as issued by duagon.

These provisions form an integrated part of the product properties. duagon products cannot be acquired with other or more extensive degrees of warranty and liability on the part of duagon.

This data sheet is to be evaluated in accordance with Swiss law. The court of jurisdiction is the seat of the vendor. The applicability of the UN agreement as to international sales of goods (also known as "Viennese Purchasing Convention") is herewith expressly excluded.

duagon AG, Riedstrasse 12, CH-8953 Dietikon, Switzerland

Phone: +41 44 743 73 00, Fax: +41 44 743 73 15, www.duagon.com

Document history:

Creator Creator Released ReleasedRev. Date Name Date Name Comments Ident-Number1 09 Apr. 2013 Ratajski 25 Apr. 2013 MRA See chapter

"DocumentHistory"

d-007510-0140902 25 Apr. 2013 Ratajski 13 May 2013 MRA d-007510-0141953 13 May 2013 Ratajski 19 Feb 2014 DZ d-007510-014287

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 2/20

Page 3: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

Table of Contents

1. General Safety Summary.........................................................................4

2. Overview...................................................................................................52.1 Features............................................................................................................................ 52.2 Block diagram................................................................................................................. 5

3. Technical Specifications...........................................................................63.1 Board layout.................................................................................................................... 63.2 Connectors....................................................................................................................... 6

3.2.1 D013 (X1, X2).......................................................................................................................... 63.2.2 D015 (X3, X4).......................................................................................................................... 73.2.3 MVB (X5, X6)............................................................................................................................ 73.2.4 Power supply.......................................................................................................................... 83.2.5 Serial channels (X8, X9, X10, X12, X13, X14).................................................................93.2.6 Reference clock RXTXC (X11).......................................................................................... 123.2.7 JTAG........................................................................................................................................ 12

3.3 Configuration switches.............................................................................................133.3.1 MVB configuration (SW1, SW2)...................................................................................... 133.3.2 General configuration (SW3 and SW6)........................................................................13

3.4 Push buttons................................................................................................................. 143.5 Status LEDs.................................................................................................................... 15

4. Standards References............................................................................16

5. Links to other duagon Documents........................................................17

6. D205 Order Information........................................................................18

7. Document History..................................................................................19

Appendix A: Document Numbering System............................................20

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 3/20

Page 4: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

1. General Safety SummaryReview the following safety precautions to avoid injury and prevent damage to this product or those connected to it. To avoid potential hazards, use this product only as specified.

Only qualified personnel should perform installation, maintenance and service procedures

To avoid fire or personal injury

Connect and disconnect properly. This data sheet contains all relevant information for connecting the device.

Power On only with all connections made. All connectors on the device must be connected (unused connections should be covered with a dummy connector).

Ground the product. Ground connection is located on the device.

Observe all terminal ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult this data sheet before making connections to the product.

Avoid exposed circuitry. Do not touch exposed connections and components when power is present.

Do not operate with suspected failures. If you suspect there is a damage to this product, have it inspected by qualified service personnel, or return it to duagon AG.

Safety Terms and Symbols

Terms in this data sheet. These terms may appear in this data sheet.

WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.

CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.

Service Safety Summary

Only qualified personnel should perform installation, maintenance and service procedures

Do not service with Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leadsbefore removing protective panels, soldering, or replacing components.

To avoid electric shock, do not touch exposed connections.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 4/20

Page 5: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

2. OverviewThe D205 is an evaluation board for two duagon MVB controllers (D013 and D015). Itallows full access to MVB controller through serial interface, without any hardware development.

2.1 Features• MVB EMD or ESD operation

• D013/D015 serial interface

• Wide power supply range (5V to 15V)

• Flexible interfacing possibilities (LVTTL, RS-232 or RS-485)

• exposed duagon Command Line Interface of D013/D015– for example for software updates

• exposed JTAG interface of D013/D015

2.2 Block diagram

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 5/20

X1

D013 host

X3, X4

D015 host

X8CH0 (RS232)

X12CH0 (LVTTL)

X9CH1 (RS232)

X13CH1 (LVTTL)

X10CLI / RESETN (RS232)

X14CLI / RESETN (LVTTL)

X2

D013 MVB

X5, X6

MVB

X7 / X15

Power

X11

Reference clock

D013

D015

RS232RS485

RS232

RS232

Power supply

X16JTAG

Page 6: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

3. Technical Specifications

3.1 Board layout

3.2 Connectors3.2.1 D013 (X1, X2)

X1

X2

X1 and X2 connectors correspond to D013 connectors X1and X2 (respectively). Check D013 data sheet (d-001030-nnnnnn) for detailed pin out.

CAUTION. It is allowed to have only one MVB interface module (D013 OR D015) at the time.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 6/20

D013

D015

Pow

er s

uppl

y

CH0

RS23

2 / R

S485

Config.

HO

LD_T

X

MV

B co

nnec

tors

CH1 - RS232

MV

B co

nfig

urat

ion

UA

RT c

lock

ex

tern

al i

nput

Stat

us L

EDs

CLI /

RES

ETN

RS

232

CLI -

LV

TTL

CH0

- LV

TTL

CH1 - LVTTL

D01

3 X1

D01

3 X2

JTAG

Reset

Page 7: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

3.2.2 D015 (X3, X4)

X4

X3

X3 and X4 connectors correspond to D015 connectors X2 and X4 (respectively). Check D015 data sheet (d-002190-nnnnnn) for detailed pin out.

CAUTION. It is allowed to have only one MVB interface module (D013 OR D015) at the time.

3.2.3 MVB (X5, X6)Note: It is applicable for use with D013 MVB interface only.

X6

X5

ESD+ Configuration

Pin #Pin Shortcut

Input / Outputas seen from the D205

Description

1 A.data.P

bidirectional

non- inverted MVB bus line, with RS485- level

2 A.data.Ninverted MVB bus line, with RS485- level

3 NC - Not connected

4 B.data.P

bidirectional

non- inverted MVB bus line, with RS485- level

5 B.data.Ninverted MVB bus line, with RS485- level

6 A.0V.term

power outputpower supply from D503_PCB to external terminator

8 A.5V.term

7 B.0V.term

9 B.5V.term

shell Shield - Connection to shield resp. housing.

Note: Both connectors have the same pinout, and all pins except pin "NC" are routed from one connector to the other.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 7/20

Page 8: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

EMD Configuration

Pin #Pin Shortcut

Input / Output as seen from the D205

Description

1 A.data.Pbidirectional

non- inverted MVB bus line

2 A.data.N inverted MVB bus line

3 NC - Not connected

4 B.data.Pbidirectional

non- inverted MVB bus line

5 B.data.N inverted MVB bus line

6, 7 A.termPassive resistor Termination resistor between two pins

8, 9 B.term

Shell Shield - Connection to shield resp. housing.

Note: Both connectors have the same pinout, and all pins except pin "NC" are routed from one connector to the other.

3.2.4 Power supplyOption P1 (X7)

X7

Pin #Pin Shortcut

Input / Output as seenfrom the D205

Description

Center pin VIN power input Power supply input

Outer contact

GND power input Power ground

The connector is EIAJ-Standard compatible – JSBJ 4.

Dimensions Value

Outer diameter 5.5 mm

Inner diameter 3.3 mm

Diameter center pin 1.0 mm

Compatible plug: i.e. Lumberg 1636 04.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 8/20

Page 9: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

Option P2 (X15)

Pin #Pin Shortcut

Input / Output as seenfrom the D205

Description

1 GND power input Power ground

2 VIN power input Power supply input

Compatible plug: i.e. Phoenix Contact MSTB 2,5/ 2-ST-5,08 (1757019).

Power supply requirements

Min. Typ. Max.

Voltage 5 V 15 V

Current 1) 10 mA1) Consumption of the product it self. Power requirements of D013 and D015 must betaken into consideration as well.

3.2.5 Serial channels (X8, X9, X10, X12, X13, X14)

X8 (RS-232 mode)

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1, 4, 6, 9

n.c. - not connected

2 TX0 output RS-232 channel 0 transmit

3 RX0 input RS-232 channel 0 receive

5 GND - Signal ground

7 HOLD_TX0 input RS-232 channel 0 hold TX

8 HOLD_RX0 output RS-232 channel 0 hold RX

CAUTION. Use only with RS-232, Full-duplex mode. Not proper configuration may lead to damage of connected devices. Refer to 3.3.2 for more details.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 9/20

X15

X8

X13

X9

X10

X14

X12

Page 10: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

X8 (RS-485 mode)

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1, 4, 8, 9

n.c. - not connected

2 RX- inputinverted signal line, with RS485- level

3 TX- / RXTX- output/ bidirectionalinverted signal line, with RS485- level

5 GND - Signal ground

6 RX+ inputnon- inverted signal line, with RS485- level

7 TX+ / RXTX- output / bidirectionalnon- inverted signal line, with RS485- level

CAUTION. Use only with RS-485 mode. Not proper configuration may lead to damage of connected devices. Refer to 3.3.2 for more details.

NOTE: Transmitter must be enabled to use this connector. Refer to 3.3.2 for more details.

X9

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1, 4, 6, 9

n.c. - not connected

2 TX1 RS-232 channel 1 transmit

3 RX1 RS-232 channel 1 receive

5 GND - Signal ground

7 HOLD_TX1 RS-232 channel 1 hold TX

8 HOLD_RX1 RS-232 channel 1 hold RX

NOTE: Transmitter must be enabled to use this connector. Refer to 3.3.2 for more details.

X10

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1, 4, 6, 9, 8

n.c. - not connected

2 CLI_TX outputRS-232 debug interface trans-mit

3 CLI_RX input RS-232 debug interface receive

5 GND - Signal ground

7 EXT. RESET inputRS-232 level external reset in-put

Refer to d-002357-nnnnnn to get more details on CLI interface.

NOTE: Transmitter must be enabled to use this connector. Refer to 3.3.2 for more details.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 10/20

Page 11: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

X12

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1 GND - Signal ground

2 HOLD_RX0 output LVTTL channel 0 hold RX

3 n.c. - not connected

4 RXD0 input LVTTL channel 0 receive

5 TXD0 output LVTTL channel 0 transmit

6 HOLD_TX0 input LVTTL channel 0 hold TX

CAUTION. Do not drive inputs with enabled transmitter. It may lead to damage of the device. Refer to 3.3.2 for more details.

X13

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1 GND - Signal ground

2 HOLD_RX1 output LVTTL channel 1 hold RX

3 n.c. - not connected

4 RXD1 input LVTTL channel 1 receive

5 TXD1 output LVTTL channel 1 transmit

6 HOLD_TX1 input LVTTL channel 1 hold TX

CAUTION. Do not drive inputs with enabled transmitter. It may lead to damage of the device. Refer to 3.3.2 for more details.

X14

Pin # Pin ShortcutInput / Output as seenfrom the D205

Description

1 GND - Signal ground

2 n.c. - not connected

3 n.c. - not connected

4 CLI_RXD input LVTTL CLI interface receive

5 CLI_TXD output LVTTL CLI interface transmit

6 EXT. RESET input LVTTL external reset input

Refer to d-002357-nnnnnn to get more details on CLI interface.

CAUTION. Do not drive inputs with enabled transmitter. It may lead to damage of the device. Refer to 3.3.2 for more details.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 11/20

Page 12: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

3.2.6 Reference clock RXTXC (X11)

X11

Pin #Pin Shortcut

Input / Output as seen from the D205

Description

1 RXTXC inputSerial interface reference clock input, LVTTL level

CASE GND - Signal ground

3.2.7 JTAG

Pin #Pin Shortcut

Input / Output as seen from the D205

Description

1 TCK input Clock signal

2, 10 GND - Signal ground

3 TDO output Data from D013/D015

4 +3V3 output Target power supply

5 TMS input JTAG state machine control

6 +3V3 - Board power supply

7, 8 n.c. - not connected

9 TDI input Data to D013/D015

The connector is compatible with Altera USB-Blaster Download Cable

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 12/20

X16pin 1

Page 13: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

3.3 Configuration switches3.3.1 MVB configuration (SW1, SW2)

SW2 SW1

SW1

Pos. # ON OFF

1 to 10 EMD ESD+

SW2

Pos. # ON OFF

1 to 10 ESD+ EMD

3.3.2 General configuration (SW3 and SW6)

Pos. # ON OFF

SW3–1 to 7 not used

SW3–8 HOLD_TX0 line connected HOLD_TX0 line disconnected

SW3–9 HOLD_TX1 line connected HOLD_TX1 line disconnected

SW3–10 RTS line connected to RESETN RTS not connected

SW6–1 use RS-232/RS-485 serial interface

use LVTTL serial interface

SW6–2 use RS-485 serial interface use RS-232 serial interface

SW6–3 RS-485 half duplex RS-485 full duplex

SW6–4 RS-485 terminator disabled RS-485 terminator enabled

SW6–5 MODE0=1 (EMD) MODE0=0 (ESD+)

SW6–6 to 8 see Serial interface baud rate configuration

SW6–9 Parity Enabled Parity Disabled

SW6–10 Even Parity Odd Parity

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 13/20

SW6

SW3

Page 14: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

Serial interface baud rate configuration

SW3 Pos. 2

BAUD0

SW3 Pos. 3

BAUD1

SW3 Pos. 4

BAUD2

Baud rate

OFF OFF OFF 1200 bps

ON OFF OFF 4800 bps

OFF ON OFF 9600 bps

ON ON OFF 19200 bps

OFF OFF ON 38400 bps

ON OFF ON 57600 bps

OFF ON ON 115200 bps

ON ON ON Use RXTXC reference clock

3.4 Push buttons

Name Description

SW4 Force HOLD_TX0

SW5 Force HOLD_TX1

SW7 Force reset

CAUTION. Before using SW4 and SW5, make sure HOLD_TX lines are disconnected. Refer to 3.3.2 for more details.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 14/20

SW7

SW5

SW4

Page 15: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

3.5 Status LEDs

Name Description

RESETN External reset is applied

RXTXC External clock is applied

RXD1 Activity on channel 1 – receive

TXD1 Activity on channel 1 – transmit

RXD0 Activity on channel 0 – receive

TXD0 Activity on channel 0 – transmit

HOLD_RX1 HOLD_RX on channel 1 active

HOLD_RX0 HOLD_RX on channel 0 active

+3.3V Power supply is present

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 15/20

Page 16: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

4. Standards ReferencesThe D205 is intended for use for engineering development or evaluationpurposes only. It is not considered by duagon to be a product fit for generalconsumer use. It shall be handled by qualified personnel only.

The D205 does not fall within the scope of the European Union directives regardingelectromagnetic compatibility, recycling (WEEE), FCC, CE or UL, and therefore maynot meet the technical requirements of these directives or other related directives.

MVBThe D205 has been designed to meet IEC61375-1:2007, International Electrotech-nical Commission, "Electric Railway Equipment, Train bus, Train Communication Network": Clause 3 describes the MVB "Multifunction Vehicle Bus".

ManufacturingThe product complies to the European Union directive EC/2002/95 (RoHS compliance).

REACHConcerning the European Union directive EC/1907/2006 (REACH compliance),duagon does not need to register any substance. duagon's products do not usequantities of more than 1 ton of a certain substance and the substances are notreleased under normal conditions of use. For a registration, both criteria would haveto be fulfilled.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 16/20

Page 17: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

5. Links to other duagon DocumentsIn general, most of the documents are located on www.duagon.com, and may be downloaded from there in the most up to date version.

D013 MVB Controller Component – Data Sheet, d-001030-nnnnnnA data sheet for the D013 is an MVB Controller Component on a 48×50 mm size footprint. The D013 can be considered as an MVB communication chip for integration on board of a customer PCB.

The D013 fully complies to the TCN standard IEC61375 as well as the more general EN50155.

D015M PC/30 MVB Interface – Data Sheet, d-002190-nnnnnnA data sheet for the D015M is a multi-purpose MVB interface on a 40×85mm size footprint (PC/30).

MVB UART Emulation Protocol, Data Sheet, d-000206-002678This document describes the interface (referred to as "UART emulation") between a host processor system and a duagon MVB interface product.

Command Line Interface (CLI) - Data Sheet, d-002357-nnnnnnThis document describes the features of the Command Line Interface (CLI) available on Duagon products.

Labeling and Packaging – Specification, d-000778-nnnnnnnThis document describes all product labels (e.g. serial number label) used in relation with customers. It describes furthermore how duagon packs the products for shipment.

Material and Components for Wiring – Technical Note, d-000842-nnnnnnThis document is intended for engineers to help them select the right connectors, etc.

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 17/20

Page 18: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

6. D205 Order InformationThere product is available in one version.

D205 -P2

Product Type:MVB Interface Development Board D205

Power Connector:EIAJ-Standard compatible -P1

Phoenix Contact compatible -P2

MVB Type:EMD or ESD+ <empty>

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 18/20

Page 19: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

7. Document Historyd-007510-014287

• Full data sheet

d-007510-014195• Product name changed

d-007510-014090• First draft data sheet

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZPage 19/20

Page 20: D205 MVB interfaces development board - duagon AG · D205 MVB interfaces development board ... X1 and X2 connectors correspond to ... It is applicable for use with D013 MVB interface

d-007510-014287

Appendix A: Document Numbering Sys-tem

All duagon documents have a unique identification number. The identification number has a certain internal structure in order to ease the tracking of different documents. In general, there are two parts:

Prefix Document number Filing number

d -000310 -001952

Always constant

Specifies a certain purpose of a document with the intention to link several documents with different filing number.

Please note, that the purpose of the document number is not stored for each document number, but can be derived from the document title, which is stored for each Filing number.

The format is either 6 digits or not available.

Unique number, that identifies a particular document. Released in sequential manner as the documents are filed in the archive. A duagon- internal data base contains exactly one document title text for each filing number.

Always 6 digits.

Examples for identification numbers

Identification number

Document Title / Remarks

d-000310-001606

d-000310-001952

„DXIO data sheet Rev 2.2"

„DXIO data sheet Rev 2.3"

A document, that is updated from time to time: the document number has the purpose to link several versions of the „DXIO data sheet" together. The filing number distinguishes between different versions.

Please note, that the document number part is kept the same, as long as the basic intention of the early versions is still kept, for example during revisions due to debugging ormanufacturing updates.

In case a significant change happens, another document number would be applied.

d-000719 „Notes from prototype meeting ..."

A document, that is obviously not updated after release. The „document number" part is missing and the filing number remains the only used part for identification.

Recommendation: In your order, you may specify for example "d-000584-nnnnnn" in order to get the "newest" version of a specific product. When you do not want to follow the sequence of newer versions, i.e. you want to stick to a specific version, then specify the full identification number like "d-000584-002043".

© duagon AG • Riedstrasse 12 • CH-8953 Dietikon • www.duagon.com released: 19 Feb 2014 / DZ Page 20/20