d impact area ûúwater infrastructure y ) · pdf fileservicing infrastructure...

6
! U Û Ú " ) 65w Rd Old Boundary Rd Rowan Lane 25 West Rd M ou br a y s Lan e 1 0 5 W e s t R d Murtcaim Rd Tyquins Lane 145 West Rd We s t T a n k s R d 40 So u t h R d 200 South Rd 120 South Rd 80 South Rd Live Bomb Range Rd 160 South Rd Galvin Rd Mcpherson Rd W e s t s R d Browns Rd Bul ban R d Station St Manor Rd Metropolitan Farm Rd Ball Rd Newtons Rd Alfred Rd W e rri bee Main R d L ittle Ri ver Rd Bulban Rd Princes Fwy Princes Fwy Princes Hwy L o l l y p o p C re e k L ittl e R i v e r Belfrages Wetland/swamp Pauls Wetland/swamp Note For all options, a water tapping at the existing CWW 150mm diameter pipe on the northern side of Little River Road is required. A private water pipe will run from this location to the YJC site along the proposed access road. Option 2 Upgrade the Little River Inlet between the Moubray Lane Pump Station and the Princes Freeway crossing (approximately 3000 m of new pipe) Option 1 Install a pressure sustaining valve at the tapping location and install water storage tanks on-site. Option 3 Refurbish the existing City West Water Moubray Lane Pump Station Matter: 25266, Date: 11 October 2017, Checked by: MSS, Drawn by: LDM, Last edited by: lmilne Location:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd Scale: 1:25,000 @ A3 Coordinate System: GDA 1994 MGA Zone 55 Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong Appendix D.1 Ancillary servicing infrastructure plans - existing and potential potable water supply options 0 250 500 750 1,000 1,250 Metres Legend Study area Impact area Water infrastructure " ) Maubray Lane pump station Existing City West Water 150mm potable water pipe Existing City West Water 225mm potable water pipe New private water pipe Sewer infrastructure Û Ú Existing City West Water sewer manhole ! U Proposed pump station Description Proposed rising main - Option 1 Proposed rising main - Option 2 Proposed rising main - Option 1 and 2 Proposed rising main - Option 4 Acknowledgements: State Government of Victoria - VicMap - Nearmap ± Note: Spatial data has been digitised from the Asset Owner Consultation Report (ARUP, June 2017)

Upload: truongkhanh

Post on 20-Mar-2018

223 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

!U

ÛÚ

")

65w

Rd

Old Boundary Rd

Rowan Lane

25 W

est R

d

Moub

r ays L

ane

105 W

estR

d

Murtcaim Rd

Tyqu

ins La

ne

145 W

est R

d

WestTan

ksRd

40 South Rd

200 South Rd

120 South Rd

80 South Rd

Live B

omb R

ange

Rd

160 South Rd

Galvin Rd

Mcpherson Rd

Wests

Rd

Brow

ns Rd

Bulban Rd

Station St

Manor Rd

Metro

polita

n Farm

Rd

Ball R

d

Newt

ons R

d

Alfred Rd

Werribee Main Rd

Little River Rd

Bulban Rd

Princes Fwy

Princes Fwy

Princ

es Hw

y

Lollypop Creek

Little River

Belfrages Wetland/swampPauls Wetland/swamp

NoteFor all options, a water tapping at theexisting CWW 150mm diameter pipe on the northernside of Little River Road is required. Aprivate water pipe will run from this locationto the YJC site along the proposed access road.

Option 2Upgrade the Little RiverInlet between theMoubray Lane PumpStation and thePrinces Freeway crossing(approximately 3000 mof new pipe)

Option 1Install a pressuresustaining valveat the tappinglocation and installwater storage tankson-site.

Option 3Refurbish theexisting CityWest WaterMoubray LanePump Station

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:25,000 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.1 Ancillary servicing infrastructure plans - existing and potential potable water supply options

0 250 500 750 1,000 1,250

Metres

LegendStudy areaImpact area

Water infrastructure") Maubray Lane pump station

Existing City West Water 150mm potable water pipeExisting City West Water 225mm potable water pipeNew private water pipe

Sewer infrastructure

ÛÚExisting City West Water sewer manhole

!U Proposed pump stationDescription

Proposed rising main - Option 1Proposed rising main - Option 2Proposed rising main - Option 1 and 2Proposed rising main - Option 4

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)

Page 2: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

!U

¬O

ÛÚ

65w

Rd

Old Boundary Rd

Hill L

ane

Tinklers Lane

Rowan Lane

25 W

est R

d

Cliff Rd

Moub

raysL

a ne

1 05 W

estR

d

Murtcaim Rd

Tyqu

ins La

ne

145 W

est R

d

WestTa

nks

Rd

40 South Rd

200 South Rd

Flume Rd

120 South Rd

15 Ea

st Rd

55 Ea

st Rd

80 South Rd

Adve

ntRd

Metro

polita

n Farm

RdCh

arter

Rd

Galvin

Rd

Supple St

Farm

Rd Dequin Ct

160 South Rd

WestleighDr

Dutch

elm Av

Timba

rraDr

Delmont

S t

Trami

ner R

ow

Doolan St

Bloom St

Una CtHopetoun

Rd

Distric

t Av

New Farm Rd

Kayden CtVineyard Tce

Lexington CtNoe lhurst Ct

Belmarino Ct

Cano

py Way

Foca l

Rd

Newmarket Rd

Ribera Ct

Mcgra

th Rd

Wests Rd

Tesron CtCoulton Ct

Killara

Ct

Brow

ns Rd

Bulban Rd

Beldale Av

Station StManor Rd

Main Dr

Alfred RdBall R

d

Werribee Main Rd

Little River Rd 160 South Rd

Bulban Rd

Princ

es Hw

y

Princes FwyLollypop Creek

Little Rive r

Option 4Construct newrising mainalong 100South Road

Option 1 and 2Construct new pumpstation on thedevelopment site

Option 1, 2 and 4Construct emergencystorage on thedevelopment site

Option 3Constructpackaged wastewatertreatment plant andland disposal fieldon developmentsite. No further sewerreticulation required

Option 1 and 2Construct new risingmain along newroads and along thenorthern side of thePrincess Freeway

Option 2Connect toMelbourneWater westerntrunk sewer(Distance 12km)

Option 1Connect to CityWest Water sewer(Distance 11km)

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:27,500 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.2 Ancillary servicing infrastructure plans - existing and potential sewerage supply options

0 250 500 750 1,000 1,250

Metres

LegendStudy areaImpact area

Sewer infrastructure

¬OExisting Melbourne Water sewer manhole

ÛÚExisting City West Water sewer manhole

!U Proposed pump stationDescription

Proposed rising main - Option 1Proposed rising main - Option 2Proposed rising main - Option 1 and 2Proposed rising main - Option 4

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)

Page 3: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

!(

#*

#*

)

!U

40 South Rd

65w

Rd

Old Boundary Rd

Moub

rays L

ane

1 05 W

estR

d

Murtcaim Rd

Tyquin

s Lan

e

145 W

est R

d

Wes tTa

nks

Rd

Rowan Lane

120 South Rd

80 South Rd

Live B

omb R

ange

RdGalvin Rd

160 South Rd

Ribera Ct

Ho petou n Rd

Lexington CtNoelhurst Ct

Belmarino Ct

Wests Rd

Mcgra

th Rd

Brow

ns Rd

Bulban Rd

Narraburra Rd

Station St

Metro

polita

n Farm

Rd

Mcpherson Rd

Manor Rd

Newt

ons R

d

Alfred RdBall R

d

Little River Rd160 South Rd

Bulban Rd

Werribee M ain Rd

Princes Hwy

Princes Fwy

Princes Fwy

Lollypop Creek

Little River

Pauls Wetland/swampBelfrages Wetland/swamp

Option 2Construct a new city gate off the existing APAtransmission main. Gate could be on either side of thefreeway. New distribution pipe from the gate to runalong the new public road and new private road tothe site A distribution pipe from the new citygate to the meter/regulator on the YJC site would beexpected to run along the proposed access road as shown

Option 1Construct a new distributionpipe off the existingWerribeeGas Network to the proposedmeter/regulator located onthe YJC site. (Pipe routeshown is indicative only)

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:25,000 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.3 Ancillary servicing infrastructure plans - existing and potential gas supply options

0 250 500 750 1,000 1,250

Metres

LegendStudy areaImpact area

Sewer infrastructure!U Proposed pump station

DescriptionProposed rising main - Option 1Proposed rising main - Option 2Proposed rising main - Option 1 and 2Proposed rising main - Option 4

Gas infrastructure

)Existing AusNet Gas distribution network

#*Proposed gas meter / regulator (on-site)

!( Proposed small gas city gateExisting APA 350mm transmission mainExisting APA 500mm transmission mainProposed AusNet gas distribution pipeProposed gas high pressure main

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)

Page 4: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

ÛÚ

!U

120 South Rd

Moub

r aysL

ane

Tyqu

ins La

ne

145 W

est R

d

Murtcaim Rd

West Ta

nks Rd

Wests Rd

160 South Rd

Station St

Morrisons Lane

Little River Rd160 South Rd

Princes FwyLollypop Creek

Lollyp

op

Creek

Tributary To Lollypop Creek

Pauls Wetland/swampBelfrages Wetland/swamp

Option 1Powercor HV Meter /Cubical to be installed atstart of proposed accessroad. All infrastructurelocated downstream ofthis is owned andmanaged by DJR

NoteHV pole located onthe northern sideof Prince Freeway, betweenthe existing on andoff ramps as shown

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:15,000 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.4 Ancillary servicing infrastructure plans - existing and potential electricity supply options -Option 1 HV Customer

0 250 500 750

Metres

LegendStudy areaImpact area

Sewer infrastructure!U Proposed pump station

DescriptionProposed rising main - Option 1 and 2Proposed rising main - Option 4

Electricity infrastructureÛÚ Proposed DJR kiosk substation

Existing Powercor 66kV overhead cableProposed 22 kV overhead cable - Option 1 - DJRProposed 22 kV overhead cable - Option 1 - Powercor

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)

Page 5: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

ÛÚ

!U

120 South Rd

Moub

r aysL

ane

Tyqu

ins La

ne

145 W

est R

d

Murtcaim Rd

West T

ank s

Rd

Wests Rd

160 South Rd

Station St

Morrisons Lane

Little River Rd160 South Rd

Princes FwyLollypop Creek

Lollyp

op Creek

Tributary To Lollypop Creek

Pauls Wetland/swampBelfrages Wetland/swamp

NoteHV pole located onthe northern sideof Prince Freeway, betweenthe existing on andoff ramps as shown

Option 2All HV infrastructurefrom the HV tee offpole to and includingthe kiosk substationis owned and managedby Powercor

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:15,000 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.5 Ancillary servicing infrastructure plans - existing and potential electricity supply options -Option 2 LV Customer

0 250 500 750

Metres

LegendStudy areaImpact area

Sewer infrastructure!U Proposed pump station

DescriptionProposed rising main - Option 1 and 2Proposed rising main - Option 4

Electricity infrastructure

ÛÚProposed Powercor kiosk substationExisting Powercor 66kV overhead cableProposed 22 kV overhead cable - Option 2 - Powercor

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)

Page 6: d Impact area ÛÚWater infrastructure y ) · PDF fileservicing infrastructure plans ... Biosis Pty Ltd Albury, Ballarat, Melbourne, Newcastle, Sydney, Wangaratta & Wollongong

!U

ÛÚ

65w

Rd

Old Boundary Rd

Rowan Lane

25 W

est R

d

M oub

raysL

ane

1 05 W

estR

d

Murtcaim Rd

Tyqu

ins La

ne

145 W

est R

d

TinklersLane

WestTa

n ks

Rd

40 South Rd

Live B

omb R

ange

Rd

15 Ea

st Rd

120 South Rd

80 South Rd

Adve

ntRd

Chart

erRd

Galvin Rd

Explor

ation

Av

160 South Rd

WestleighDr

Dutch

elm Av

Delmont

St

New Farm Rd

Newmarket Rd

Hopetoun Rd

Lexington CtNoelhu rst Ct

Belmarino Ct

Canopy

WayF o

calRd

JaniceCt RiberaCt

Metro

polita

n Farm

Rd

Wests Rd

Mcgr

ath Rd

Coulton Ct

Killara

Ct

Brow

ns Rd

Bulban Rd

Beldale Av

Station St

Manor Rd

Alfred RdBall R

d

Werribee Main Rd

Little River Rd160 South Rd

Bulban Rd

Princ

es Hw

y

Princes Fwy

Princes Fwy

LollypopCreek

Belfrages Wetland/swampPauls Wetland/swamp

Option 2 and 3A fixed copper connectionwould be constructedfrom the existingtelecommunications networkon Princes Freewayalong the proposed accessroad to the YJC site

Option 1 and 3For fixed wireless NBN no newsignificant infrastructure isrequired to beconstructed. An antenna andaccompanying connection boxwould be located on abuilding within the facility.

Matter: 25266,Date: 11 October 2017,Checked by: MSS, Drawn by: LDM, Last edited by: lmilneLocation:P:\25100s\25102\Mapping\25266_AppC_AncillaryInfrastructure.mxd

Scale: 1:25,000 @ A3Coordinate System: GDA 1994 MGA Zone 55

Biosis Pty LtdAlbury, Ballarat, Melbourne, Newcastle,

Sydney, Wangaratta & Wollongong

Appendix D.6 Ancillary servicing infrastructure plans - existing and potential communications supply options

0 250 500 750 1,000 1,250

Metres

LegendStudy areaImpact area

Sewer infrastructure

ÛÚExisting City West Water sewer manhole

!U Proposed pump stationDescription

Proposed rising main - Option 1Proposed rising main - Option 2Proposed rising main - Option 1 and 2Proposed rising main - Option 4

Communications infrastructureExisting Telstra communications conduitProposed Telstra copper cable

Acknowledgements: State Government of Victoria - VicMap - Nearmap

±

Note: Spatial data has been digitised from the AssetOwner Consultation Report (ARUP, June 2017)