Head Office 599 Norris Court Kingston, On. K7P2R9 Toll Free T: 800-479-3875 Toll free F: 800-866-7690 Intl T: 613-384-4144 Intl F: 613-384-0167 E: [email protected] W: www.fusetek.com 2.75kV, 5.5kV & 8.3kV ‘R’ Rated Motor Fuses pub: MVR09-1 Printed in Canada Other Medium Voltage Products - ‘E’ Rated Distribution Fuse to 28.8kV - DIN Distribution Fuses to 38kV - Load Break Switches to 38kV - Capacitor Fuses - Adapter Kits & Live Parts - Remote Indicator Kits - Clips & Insulators - PT Fuses to 38kV Dimensions - Standard 15.88” 403mm 17.8” 457mm 19.3” 490mm 3” 76.2mm 3” 76.2mm .44” X .91” Slots (1.53” c.t.c.) 3” 76.2mm .63” max 16mm .63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions - GE Tags Dimensions for GE tags are dictated by the GE starters they fit into. 15.88” 403mm 15.88” 403mm 3” 76.2mm 3” 76.2mm .63” max 16mm 3” 76.2mm .63” max 16mm 6.31” 160mm 3” 76.2mm D DD ‘R’ Rated Motor Fuses

Upload: others

Post on 12-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

Head Office

599 Norris CourtKingston, On. K7P2R9

Toll Free T: 800-479-3875Toll free F: 800-866-7690

Intl T: 613-384-4144Intl F: 613-384-0167

E: [email protected]: www.fusetek.com

2.75kV, 5.5kV & 8.3kV ‘R’ Rated Motor Fuses

pub: MVR09-1 Printed in Canada

Other Medium Voltage Products

- ‘E’ Rated Distribution Fuse to 28.8kV

- DIN Distribution Fuses to 38kV

- Load Break Switches to 38kV

- Capacitor Fuses

- Adapter Kits & Live Parts

- Remote Indicator Kits

- Clips & Insulators

- PT Fuses to 38kV

Dimensions - Standard

15.88”403mm

17.8”457mm

19.3”490mm

3”76.2mm

3”76.2mm

.44” X .91” Slots(1.53” c.t.c.)

3”76.2mm

.63” max16mm

.63” max16mm

3”76.2mm

3.6”91.4mm

7.6”193mm

Front view

Dimensions - ‘B’ bolt-in

Dimensions - GE TagsDimensions for GE tags are dictated by the GE starters they fi t into.

15.88”403mm

15.88”403mm

3”76.2mm

3”76.2mm

.63” max16mm

3”76.2mm

.63” max16mm

6.31” 160mm

3”76.2mm

D

DD

‘R’ Rated Motor Fuses

Page 2: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

KNOWLEDGE, SERVICE, SOLUTIONSMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor FusesMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor Fuses

‘R’ Rated Motor Fuses

MVR fuses are current and energy limiting fuses intended for the backup protection of medium voltage motor control. They are non-venting.

MVR fuses have integral striker/indicators and have standardized dimensions compatible with today’s 5.5kV motor control gear. They are fully interchangeable with other manufacturers’ fuses of the same type and rating.

They feature a ‘fi eld toughened’ element design which makes them less susceptible to mechanical damage during shipping and installation while also providing superior cycling characteristics.

Features

• Integral indicating pin

• Standard “R” Ratings

• Toughened element design

• Fully plated parts

Standard Hook-eye Bolt-in Extended

1B

GE 1B-Bolt-in

1iB

GE 1iB-bolt-inInverted

MVR Series General Specifi cationsSeries Vac I.R Clip Diam Clip centers Ratings OptionsMVR2 2.75kV

50kA rms symm 3”

7” (178mm) 25A, 30A, 2R, 3R, 4R, 5R, 6R, 9R, 12R, 18R,

24R, 36R

B,Y,SMVR5 5.5kV 12” (305mm) B,Y,S,X,1B,1iBMVR8 8.3kV 12” (305mm) B,Y,S

Options

Standard fuses are clip-in design with 3” diameter barrels (18R - 36R are double barrel designs) and have an integral striker/in-dicator pin. Several options are available to make them compatible with other manufacturers’ specialized designs. Add suffi xes to the part number as required. More than one option can be specifi ed.

All options are not available in some voltages.

Medium voltage LED line Indicators

Bolt these line indicators onto any convenient live part and the high brightness LED cluster will fl ash to indicate presence of voltage. Rated for 2.5kV - 38kV

Epoxy Resin Insulators

We carry a range of epoxy resin insulators from 7.2kV to 38kV. Tapped brass inserts can accomodate a wide range of equipment.

HV Accessories600 Amp clip for 3” diameter barrels

Steel backup spring for high pressure contact.Compatible with any 3” diameter fuse.

p/n. FC3R

Hookeye Add on

Hookeye kit is compatible with any 3” diameter fuse. May be ordered separately.

p/n. Hookeye

p/n. KF22-12

p/n. refer to Fusetek

Medium Voltage Microswitch

Need more than visual indication? Our remote mount microswitch is good for all systems up to 38kV. The insulated Bowden cable is actu-ated by the fuse striker which then actuates the microswitch at the other end.

p/n. 3100110

Medium voltage bases

Fusetek can supply single or 3 pole bases for most of the medium voltage fuses we supply.

p/n. refer to Fusetek

Page 3: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

KNOWLEDGE, SERVICE, SOLUTIONSMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor FusesMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor Fuses

Part Number System

MV R 5 / 09R - DI XYS

Installation Notes:

1. When replacing ‘R’ fuses, always replace with the same ‘R’ rating to maintain coordination and motor starting capability.

2. These fuses can replace any manufacturers’ fuse of same ‘R’ rating.

3. Ensure that fuse clips have good tension. (if you can spin the fuse in the clips easily, clips should be replaced.)

4. Clean all contact surfaces before installation.

5. Install with striker pin facing up.

6. Unless the cause of fuse failure is known to have been confi ned to 1 phase, fuses should be replaced in sets of 3 to ensure ‘As new’ performance.

R Rating Defi ned

The ‘R’ rating of a fuse is established by dividing the 20-35s melt current of the fuse by 100.

Fuses of the same ‘R’ rating will have the same time current characteristics and ensure identical motor start-ing performance and coordination with the overload relays.

Technical data presented.

Amp Rating

Each fuse has both an assigned ‘R’ and amp rating. It is the ‘R’ rating of the fuse that governs the motor starting capability and coordination with the overload relays. To maintain the same capabilities, fuses should be replaced with matching ‘R’ ratings.

On direct across the line starts, the necessity of passing the motor starting current results in a fuse selection with an assigned amp rating well above the nominal motor full load amps.

However, applications using reduced voltage starts, variable frequency drives or other methods to reduce the motor starting current, can result in a fuse rating with an amp rating too close to the motor F.L.A. As a check, the fuse’s as-signed full load amp rating should be a minimum of 140% of the nominal full load amps of the motor.

MV Series 5 09R DI XYSMedium Voltage R Motor Fuse Voltage Class Rating Body Size Option Modifi er

2 = 2.75kV 25A, 30A2R, 3R4R, 5R6R, 9R

12R, 18R24R, 36R

D = Single 3” I = Striker (standard)X = 2” extensionB = Bolt-inS = Div. 1, class llY = Hookeye1B = GE Tags1iB = GE inverted tags

5 = 5.5kV DD = Double 3”8 = 8.3kV

9R200A

RMS Amperes

1000.01

0.1

10

100

1

1000 10000 100000

8.3kV Total Clearing Time Current Characteristics

2R3R4R5R6R9R12R18R24R36R

Tim

e in

Sec

onds

Page 4: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

KNOWLEDGE, SERVICE, SOLUTIONSMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor FusesMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor Fuses

Total Clearing time current characteristics

0.01

0.1

10

100

1

Tim

e in

Sec

onds

100 1000 10000 100000

30A2R3R4R5R6R9R12R18R24R36R

5.5kV Total Clearing Time Current Characteristics

RMS Amperes

5.5kV Total Clearing Time Current Characteristic

Peak Let-thru Characteristics

Use these characteristics to evaluate busbar bracing requirements and withstand capability of down-the-line components.

Read RMS fault value on lower scale and read up to where it intersects the line for the fuse you are evaluating. From this intersec-tion point, read across to the left hand scale to obtain the peak current let-thru. Note: this value is in peak asymmetrical amperes. To convert to RMS symmetrical, divide by 2.3. Peak let-thru graph is valid for all voltage classes.

Time current Characteristic curves.

Time current curves shown on pages 4-6 are minimum melting curves. For total clearing, please refer to the curves on pages 7-9.

Characteristic curves are generated with the fuse at an ambient temperature of 24-26 C. Ambient temperatures higher than 30 C may require fuse de-rating. Please contact Fusetek in this instance.

24R (450A)

18R (390A)12R (230A)

9R (200A)

6R (170A)5R (150A)4R (130A)3R (100A)

2R (700A)

25A/30A

RMS Symmetrical Amperes

Peak

Let

-Thr

u - A

ssym

met

rical

Am

pere

s X

1000

5 6 7 8 9 10 20.01

.02

.03

.04

.05

.06

.07

.08

.09

1

2

3

4

56789

1

.2

.3

.4

.5

.6

.7

.8

.9

10

20

30

40

5060708090

100

30 40 50 60 70 80 90 100

200

300

400

500

600

700

800

900

1000

2000

3000

4000

5000

6000

8000

9000

1000

0

2000

0

3000

0

4000

0

5000

060

000

7000

080

000

9000

010

0000

7000

Motor Application Tables.

Standard duty is defined as: 2 evenly spaced starts per hour, 25o C ambient temperature, 10 second run-up time and a starting current of no more than 6X the nominal full load amp of the motor.

If any of these parameters are exceeded - use the heavy duty (HD) column.

• Select the appropriate HP rating in the left column

• Read across to the appropriate voltage and duty column (Std or HD)

• Use the ‘R’ rating of fuse specified

• 5.5kV fuses may be used on 2.3kV control.

The graphic on the right is a screen shot from our free Fusesoft 5.0 fuse selection software and shows the ideal coordination between the fuse, overload relay and motor starting current. The motor starting tables were generated using this software. Fusesoft 5.0 can be downloaded at no charge by visiting www.fusetek.com

o o

Page 5: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

KNOWLEDGE, SERVICE, SOLUTIONSMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor FusesMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor Fuses

Total Clearing time current characteristics

These time current curves have been plotted to maximum test points so any variations should be negative. Curves are based on tests at an ambient of 25 C with fuses starting from cold with no initial load.

Tim

e in

Sec

onds

25A2R3R4R5R6R9R

12R18R24R

2.75kV Total Clearing Time Current Characteristics

0.01

0.1

10

100

1

100 1000 10000 100000RMS Amperes

2.75kV Total Clearing Time Current Characteristic

o

2.75kV Peak Current Let-through

Available Current in Amperes

Peak

inst

anta

neou

s Le

t Thr

ough

cur

rent

in K

ilo A

mpe

res

24R

25A

18R

9R/12R6R5R4R3R2R

.2

.3

.4

.5

.6

.7

.8

.91

2

345678910

20

30

405060708090

100

100

200

300

400

500

600

700

800

900

1000

2000

3000

4000

5000

6000

7000

8000

9000

1000

0

3000

0

2000

0

4000

050

000

6000

070

000

8000

090

000

1000

00

2.75kV Motor Fuses - 7” clip center

General Specifi cationsPart

Number A F.L.A. D x L(inches)

I.RkA

Avail.Options

MVR2/025A-DI 25A 25A 3 10.8

50kArms B,Y,S

MVR2/02R-DI 2R 70 3 10.8MVR2/03R-DI 3R 100 3 10.8MVR2/04R-DI 4R 130 3 10.8MVR2/05R-DI 5R 150 3 10.8MVR2/06R-DI 6R 170 3 10.8MVR2/09R-DI 9R 200 3 10.8MVR2/12R-DI 12R 230 3 10.8

MVR2/18R-DDI 18R 390 2X3 10.8MVR2/24R-DDI 24R 450 2X3 10.8

2.75kV Minimum Melt Time Current Characteristics

Fuse selection for Motors rated at 2.75kV or less

Motor HPFuse ‘R’ rating

Standard Duty Heavy Duty100 2R 2R150 3R 3R200 4R 5R250 4R 5R300 5R 6R350 6R 6R400 9R 9R450 9R 9R500 9R 12R600 12R 12R700 12R 18R800 18R 18R900 18R 18R1000 18R 24R1250 24R 24R

25A2R3R4R5R6R9R12R18R24R

RMS Amperes

Tim

e in

sec

onds

100 1000 10000 1000000.01

0.1

1

10

100

2.75 kVPeak Current Let-through

10.88”276.35mm

10.88”276.35mm

3”76.2mm

3”76.2mm

.63” max16mm

3”76.2mm

.63” max16mm

6.31” 160mm

3”76.2mm

D

DD

Page 6: D ‘R’ Rated Motor Fuses - Fusetek - 1-800-479-3875....63” max 16mm.63” max 16mm 3” 76.2mm 3.6” 91.4mm 7.6” 193mm Front view Dimensions - ‘B’ bolt-in Dimensions -

KNOWLEDGE, SERVICE, SOLUTIONSMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor FusesMVR ‘R’ Rated Motor Fuses MVR ‘R’ Rated Motor Fuses

5.5kV Motor Fuses - 12” clip center

General Specifi cationsPart

Number A F.L.A. D x L(inches)

I.RkA

Avail.Options

MVR5/030A-DI 30A 30A 3 15.8

50kArms

B.Y.S,X

MVR5/02R-DI 2R 70 3 15.8MVR5/03R-DI 3R 100 3 15.8MVR5/04R-DI 4R 130 3 15.8MVR5/05R-DI 5R 150 3 15.8MVR5/06R-DI 6R 170 3 15.8MVR5/09R-DI 9R 200 3 15.8MVR5/12R-DI 12R 230 3 15.8

MVR5/18R-DDI 18R 390 2X3 15.8MVR5/24R-DDI 24R 450 2X3 15.8MVR5/36R-DDI 36R 650 2X3 15.8

Fuse selection for Motors rated at 5.5kV or less

Motor HPFuse ‘R’ rating

Standard Duty Heavy Duty

100 30A 30A

150 2R 2R200 2R 2R250 3R 3R300 3R 3R350 3R 4R400 4R 5R450 4R 5R500 5R 6R600 5R 6R700 6R 9R800 9R 9R900 9R 12R1000 9R 12R1250 12R 18R1500 18R 18R

30A2R3R4R5R6R9R12R18R24R36R

100 1000 10000 1000000.01

0.1

1

10

100

RMS Amperes

Tim

e in

sec

on

ds

5.5kV Minimum Melt Time Current Characteristics

5.5 kV Peak Current Let-through

15.88”403mm

15.88”403mm

3”76.2mm

3”76.2mm

.63” max16mm

3”76.2mm

.63” max16mm

6.31” 160mm

3”76.2mm

D

DD

2.75kV Peak Current Let-through

Available Current in Amperes

Peak

inst

anta

neou

s Le

t Thr

ough

cur

rent

in K

ilo A

mpe

res 36R

24R

30A

18R

9R/12R6R5R4R3R2R

.2

.3

.4

.5

.6

.7

.8

.91

2

345678910

20

30

405060708090

100

100

200

300

400

500

600

700

800

900

1000

2000

3000

4000

5000

6000

7000

8000

9000

1000

0

3000

0

2000

0

4000

050

000

6000

070

000

8000

090

000

1000

00

8.3kV Motor Fuses - 12” clip center

General Specifi cationsPart

Number A F.L.A. D x L(inches)

I.RkA

Avail.Options

MVR8/02R-DI 2R 70 3 15.8

50kArms B.Y.S

MVR8/03R-DI 3R 100 3 15.8MVR8/04R-DI 4R 130 3 15.8MVR8/05R-DI 5R 150 3 15.8MVR8/06R-DI 6R 170 3 15.8MVR8/09R-DI 9R 200 3 15.8MVR8/12R-DI 12R 230 3 15.8

MVR8/18R-DDI 18R 390 2X3 15.8MVR8/24R-DDI 24R 450 2X3 15.8MVR8/36R-DDI 36R 650 2X3 15.8

Fuse selection for Motors rated at 8.3kV or less

Motor HPFuse ‘R’ rating

Standard Duty Heavy Duty

250 2R 2R

300 2R 2R350 2R 2R400 2R 3R450 3R 3R500 3R 4R600 3R 4R700 4R 5R800 4R 5R900 5R 6R1000 5R 6R1250 6R 9R1500 9R 12R

1000.01

0.1

1

10

100

1000 10000 100000

2R3R4R5R6R9R

12R18R24R36R

RMS AMPERES

Tim

e in

sec

on

ds

8.3 kVPeak Current Let-through

8.3kV Minimum Melt Time Current Characteristics

8.3kV Peak Current Let-through

Available Current in Amperes

Peak

inst

anta

neou

s Le

t Thr

ough

cur

rent

in K

ilo A

mpe

res 36R

24R18R

9R/12R6R5R4R3R2R

.2

.3

.4

.5

.6

.7

.8

.91

2

345678910

20

30

405060708090

100

100

200

300

400

500

600

700

800

900

1000

2000

3000

4000

5000

6000

7000

8000

9000

1000

0

3000

0

2000

0

4000

050

000

6000

070

000

8000

090

000

1000

00

15.88”403mm

15.88”403mm

3”76.2mm

3”76.2mm

.63” max16mm

3”76.2mm

.63” max16mm

6.31” 160mm

3”76.2mm

D

DD