Page 1 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

QUICK START

Connection and Control Interface

Item Description

1 Grounding Stub.

2 DC +5V: +5VDC external power supply.

3 BTS: Donor antenna port, uplink and downlink signals to base station.

4 Power Indicator. Green: Power on; Off: Power off.

5 ATT(Attenuation) switch panel, adjust the uplink and downlink gain.

6 RUN: Down link signal level indicator. Green: ALC not activated; Orange: ALC activated in 5-10dB;

Red: ALC activated in 15-20dB. Off: Equipment fault.

7 MS: Service antenna port, uplink and downlink signals to mobiles.

ATT(Attenuation) Switch Panel

Switch 1-5: Uplink

Switch 6-10: Downlink

Examples:

If Switch 7 &9 are set to ON, 6, 8&10 are at off position,

then the downlink gain=75-8-2=65dB.

If Switch 1 is set to ON, 2,3,4&5 are set to off position,

then the uplink gain=70-16=54dB.

Page 3: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 2 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

Wall Mount Method

Wall mount method and mounting hole positions in millimetres

1. Use percussion drill to make four holes on the wall following the pattern in the above diagram.

2. Push the wallboard anchors to the holes.

3. Hold the BDA and push against the wall. Align the 4 holes on the BDA with the anchor holes.

4. Drive two M6x60 screws into the holes on the top line. Do not fully tighten the screws.

5. Drive the other screws into the two holes on the bottom line. Do not fully tighten the screws.

6. Check BDA alignment and tighten the 4 screws one by one.

7. Ground the BDA properly to complete the installation.

Warning Message

Do NOT Power ON the BDA Before the BTS and MS Ports Are Connected to

Feedlines.

Install the BDA Only in A Normal Indoor Environment.

The Dismantlement, Modification or Use of Any Object or Device to Alter or

Limit the Functionality, Permanently or Temporarily, of Any BDA Structure

Are Prohibited.

Page 4: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 3 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

Customer Manual

Section 1 Product Description and List of Features

ER800PS-P27G75-I is a 27dBm fixed band indoor signal booster with factory preset uplink and downlink

band within 806-824MHz and 851-869MHz. 27dBm maximum output power and 75dB gain allow small to

medium size indoor areas have reliable radio communications for first responders. Automatic gain control

allows stable output power even when the handheld is close to the BDA, which protects the donor site

from interruption. The unit is housed by a compact and light alumina casting enclosure.

The built-in external switches accessible from the bottom of the enclosure allow the uplink and down link

gains be configured and optimized easily on site without additional tool. Signal strength indicator helps

find donor signal source and set up the system in the field without additional equipment.

Uplink/downlink frequency 806-824MHz/851-869MHz full range, or custom bands Built-in Saw filter provides high out of band rejection 20dBm and 27dBm maximum uplink and downlink power Built-in switches and signal strength indicator allow find donor signal source and set up the

system on site without additional equipment External 100-240VAC universal power supply Indoor wall mount Heatsink convection cooling and low power consumption Built-in ALC provides stable output power even when the handheld is close to the BDA to

minimize the interference to the donor site

Section 2 Parts Check List

Please make sure the following items are included in the box delivered to you. If any item is missing,

contact your sales representative.

Table.1 Parts check list

Item Quantity

The BDA, ER800PS-P27G75-I 1

External Power Adaptor 1

M6x40mm Screw with wallboard anchor 4

Customer Manual* 1 *Excelwave Technologies may choose to ship the product along with a hardcopy of this manual, or make it available electronically through website

download or email.

Page 5: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 4 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

Section 3 Before Installation

Please verify the uplink and downlink frequencies labeled on the equipment, ensure they match with your

PO and your system requirements. Please contact your sales representative if you find any discrepancy.

Read this manual before installation.

Install the equipment only in a normal indoor environment.

The built-in signal strength indicator supports quick deployment without additional tool and equipment.

However, we highly recommend that if possible, always use spectrum analyzer and other equipment to

assist the installation. Ideally, donor signal strength should have been measured prior to the installation

and the link budget and coverage have been calculated by certified RF system design engineer. BOM, test

plan and other documents must be in place prior to the installation.

Section 4 Safety Information and Regulations

Do not dismantle the equipment.

Do not add extra pressure to BDA enclosure or attach anything to the surface.

Use only the power adaptor supplied with the BDA, not any alternative.

The unit is for normal indoor environment application. Do not install the BDA in a strong electric,

high-intensity magnetic, corrosive, moist, excessive temperature and other harsh environments.

Install the BDA in a place that is not accessible by kids and unauthorized individuals. Install and ground the unit following local inbuilding and communication site construction codes.

It is your responsibility to ensure the use of BDA complies with FCC and other regulations.

Do not power on the BDA before BTS and MS ports are connected.

Section 5 System Diagram

Fig.1 System Diagram

Page 6: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 5 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

Section 6 Step by Step Installation Instruction

Fig.2 Installation Procedure

1. Find a proper indoor position where a good grounding path is available, usually on a wall, and

install the BDA following the steps given in the QUICK START.

2. Follow the system design documents to locate the donor antenna ad service antennas. The donor

antenna and service antennas must have sufficient isolation, and 90dB minimum is recommended

to ensure the device is working normally. Donor antenna is typically installed on the rooftop or

outside wall with high elevation, avoiding any obstacle and in line of sight with the base station

antenna. The positions and number of service antennas must be designed properly by a qualified

system design engineer with proper RF planning tool.

3. Route the feed lines from the donor antenna to the BDA and service antennas to the BDA

following the system design documents. Connect the feed line to donor antenna, and feed line to

service antenna. Waterproof the connections. Do not connect the feedlines to the BDA.

4. Verify isolation between donor antenna and service antennas. If a network analyzer is available,

it is recommended to verify the isolation between the donor antenna and service antenna by

bypassing the BDA and testing the transmission between the port of the feedline to donor

antenna and the port of the feedline to service antenna. Minimum of 90dB is preferred. If the

isolation is less than 85dB, report to your project manager and system design engineer. Relocate

Page 7: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 6 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

the donor antenna, or service antenna might be necessary. If both options are not applicable,

then the BDA gain needs to be adjusted to avoid self oscillation which needs approval from the

project manager and system design engineer, refer to step 12.

5. Adjust the donor antenna orientation.

5.1. If spectrum analyzer or other equivalent RF signal strength measurement equipment is

available (Highly recommended):

5.1.1 Set the spectrum analyzer's frequency range, bandwidth and other parameters.

5.1.2 Connect donor antenna to the input port of spectrum analyzer.

5.1.3 Adjust donor antenna direction until -45dBm to -55dBm signal strength is measured.

5.1.4 Connect the donor antenna port to the BDA ‘BTS’ port.

5.2. Install the donor antenna without spectrum analyzer:

In case spectrum analyzer or other equivalent RF signal strength measurement equipment is not

available, the “RUN” indicator on the front panel can be used to adjust the donor antenna

direction. When signal strength received from the donor antenna is lower than-48dBm, the

indicator is green; when the received signal strength is higher than -35dBm, the indicator is red;

when the received signal strength is between-45dBm and -38dBm, the indicator is orange. It is

suggested to adjust the direction of the donor antenna to make the indicator just change from

green to orange which indicates the received signal strength is around -48dBm.

5.2.1 Adjust the donor antenna direction until the “RUN” indicator just change from green to

orange.

5.2.2 Connect the donor antenna port to the BDA “BTS” port.

If the “RUN” indicator stays green when you change the donor antenna direction, this means the

donor signal is too weak and you will get degraded coverage even no coverage. Following are

what you need to do

5.2.3 Immediately report to the project manager and system design engineer.

5.2.4 Recommend to confirm the signal strength using a spectrum analyzer if possible.

5.2.5 Work with your project manager and system engineer, check if you can replace the donor

antenna by a higher gain antenna to get better signal.

5.2.6 Work with your project manager and system engineer, check if you can relocate the donor

Page 8: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 7 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

antenna to get better signal.

6. Connect the service antenna to BDA’s “MS” port.

7. Set all attenuation switches on the ATT switch panel to off position, unless the system design

document requires to reduce the uplink and down gains from factory default values.

8. Check and ensure “BTS” and “MS” ports are connected to feedlines.

9. Connect the power adapter, and plug in the power supply.

10. Follow the test plan, walk test the call quality in the service area.

11. When it is needed, service antennas may be relocated to satisfy coverage requirement. You will

need to get approval from your project manager and system design engineer.

12. During the walk test, if self oscillation (Refer to Section 9) is observed, this means either the donor

signal is too strong or antenna isolation is insufficient. Report to the project manager and system

design engineer. Repeat Step 4, 5 and 10 if possible. If the self oscillation still occurs, then

13. The gain of uplink or the downlink, or both needs to be reduced. Use the combination of switches

1-5 for uplink and 6-10 for downlink to reduce the uplink and downlink gain respectively. Repeat

the walk test until the coverage is acceptable. Document and report to project manager and

system design engineer on the gain value settlement.

14. Document the installation and test reports, and submit to project manager for approval.

Section 9 Notices

1. Never power on the equipment before both “BTS” and “MS” are connected to feedlines.

2. Always remove excessive feed lines from the equipment to donor antenna and service antenna

to minimize the cable loss.

3. Always install the donor antenna at the most available highest position and keep distance from

the service antenna to maximize the isolation between each other. The vertical distance between

donor and service antenna should be more than 3 meters.

4. Certain isolation between donor antenna and service antenna are required to avoid self-

oscillation. In case self-oscillation happens, reposition is required for the antennas.

5. The donor antenna must be placed at least 2 meters away from other antennas on the same site.

6. All feed line connections must be waterproofed.

Page 9: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 8 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

7. Self oscillation: During the walk test, if handheld indicates there is signal but no communication,

this often means self oscillation occurs. Check the RUN indicator, if it is red, this means the donor

signal is too strong or antenna isolation is insufficient. Adjust the downlink attenuation, if the red

indicator disappears, then this means the donor signal is too strong. If the red indicator does not

disappear, or the red indicator disappears only if both uplink and downlink ATT switches are on,

this indicates that there is no sufficient isolation between the donor antenna and service antennas.

Section 10 Troubleshooting

1. The power LED is OFF

Cause Action

Power supply cord has not been connected or

faulty

Check power supply connection

2. The power LED is ON (Green), but no signal transmits

Cause Action

Signal cable from service antenna has not been

connected

Check all connections

Signal cable is connected but cable is damage or

connector is broken

Make sure there is no sharp bends or breaks in

the cable, and check connectors to see whether

they are fixed firmly or not

3. Output power is not enough (Green)

Cause Action

Input signal is too weak and unstable (The “RUN”

indicator is green).

Adjust the donor antenna’s position and direction

to make sure the input signal is moderate.

4. Output power is full (Orange)

Cause Action

The BDA is working in linearity (The “RUN”

indicator is Orange).

This is the best working condition for the BDA. Do

not need to take any action.

5. Signal Oscillation (Red)

Cause Action

Over accepting of donor antenna or strong

interference (The “RUN” indicator is red).

Adjust the donor antenna’s position and direction

to make sure the input signal is moderate.

The isolation between donor antenna and service

antenna is not enough (The “RUN” indicator is

red).

Increase the distance between the two antennas

to make sure the isolation is more than 85dB.

Page 10: Customer Manual - excelwavetechnologies.com

CM-ER800PS-P27G75-I

Page 9 of 9 [email protected] www.excelwavetechnologies.com 1-888-329-2878(Tel) 1-888-318-5528(Fax) Rev.2 ©All rights reserved, 2016

Section 11 Product Specifications

Model Number ER800PS-P27G75-I

Items Uplink Downlink

Frequency Range 806-824MHz 851-869MHz

Bandwidth factory preset range 2-18MHz 2-18MHz

Output Power 20±2dBm 27±2dBm

Gain 70±3dB 75±3dB

Ripple ≤6dB ≤6dB

VSWR 2:1 2:1

Max. Input Power Without Damage -10dBm -10dBm

ATT step of 1dB

1-10dB ∣△∣≤1dB ∣△∣≤1dB

10-20dB ∣△∣≤1dB ∣△∣≤1dB

20-25dB ∣△∣≤1.5dB ∣△∣≤1.5dB

ALC Active 10dB ∣△∣≤2dB ∣△∣≤2dB

Out of Band Gain

±600kHz ≤ 40dB ≤ 50dB

±1MHz ≤ 30dB ≤ 35dB

±5MHz ≤ 25dB ≤ 30dB

Intermodulation Products ≤ -45dBc ≤ -40dBc

Spurious Emission 9KHz-1GHz ≤ -30dBm ≤ -30dBm

1GHz-12.75GHz ≤ -30dBm ≤ -30dBm

Noise Figure @ max. gain ≤ 8dB ≤ 8dB

Time Delay ≤ 5μs ≤ 5μs

Alarm

ALC not Active — Green

ALC Active 5-10dB — Orange

ALC Active 15-20dB — Red

Power LED Power ON Green

Power OFF No Light

Power Supply External AC power adaptor, 100-240VAC to 5V 4A

Power Consumption ≤15W

Dimensions 10.55”x6.10”x2.36” (268mmx155mmx60mm)

Shipping Dimensions 12”x10”x3.8”(305mmx254mmx97mm)

Weight 4.41lbs(2Kg)

Shipping Weight 6.75lbs(3.06Kg)

RF Connector N-Female

Environment Conditions IP40

Humidity < 90%

Operating Temperature -10℃- +55℃