Clinical solutions to meet the specific needs of your neonatal and pediatric ICU. Custom IV Sets & Connectors for Neonatal and Pediatric Applications > Custom IV Sets specifically designed for neonatal or pediatric applications. > Closed IV administration. > Choose from any of our needlefree connectors to best meet your needs.

Upload: others

Post on 26-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

Clinical solutions to meet the specific needs of your neonatal and pediatric ICU.

Custom IV Sets & Connectorsfor Neonatal and Pediatric Applications

> Custom IV Sets specifically designed for neonatal or pediatric applications.

> Closed IV administration.

> Choose from any of our needlefree connectors to best meet your needs.

Page 2: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

The patented technology in our complete line of needlefree IV connectors has been

clinically proven to provide an effective barrier against bacterial transfer and colonization,1,2

helping you keep your most precious patients safer from infection.

Common features of the line include:

> A single clinical protocol used with all patient populations, minimizing clinical training and in-servicing.

> Highly efficient flushing ability, helping you to completely clear the connectors of blood and blood components.

> A mechanically and microbiologically closed system, providing a safe and effective microbial barrier.

> Needlefree connector technology that has been chosen by clinicians more than twice as often as any other.3

Our newest addition to the family: NanoClave®

The NanoClave low-profile neutral displacement needlefree connector is specifically

designed with a small size and minimal residual volume to help you keep your delicate

neonatal and pediatric patients safe from infection while

effectively managing their fluids.

> Effectively clears blood and blood residual with low flush volumes.4

> Does not require a change in clinical practice or technique.

> Saline flush option can eliminate the use of heparin.

> Minimal blood reflux in the catheter tip.

A Commitment to Neonatal and Pediatric Patient SafetyWe know that improving neonatal and pediatric patient safety is a priority. And we’re here to help.

Page 3: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

NEW

NanoClave®

MicroClave®

MicroClave® Clear

Neutron®

Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific IV therapy needs?

Our custom IV set program allows facilities to maximize efficiencies by designing patient-ready sets, avoiding burdensome assembly of multiple sets and unnecessary storage of extra components.

Clinicians can choose from thousands of clinically-proven component options to design the perfect set to meet a specific need. Whether

consolidating existing sets or designing a new set from the ground up, we prove that customization does not have to cost more.

> Choice of standard IV administration or closed IV sets

> Choice of any of our needlefree neutral displacement connectors

> No long-term contracts for custom sets with standard components

> Non-sterile samples in one week, sterile samples in two weeks

> No minimum orders

> Quotes in 72 hours

Each connector is indicated for

use with a saline flush protocol.

Page 4: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

F L U J OF L O W

C L E A R S ID E

F L U J OF L O W

C L E A R S ID E

F L U J OF L O W

C L E A R S ID E

F L U JO

F L OW

C L E A R S ID E

FLUJOFLOW

FLUJO

FLOW

Closed IV Administration Sets

Item Length (in.) Priming volume (mL) Case Qty

B33303 127 9.30 50

Description: 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Anti-Siphon Valve, Smallbore Quadfuse Ext Set with MicroClave®, 4 Clamps (Blue, 2 Red, White), Tubing Clip, Rotating Luer, Non-DEHP Tubing

Description: 108” (274 cm) 10 Drop Primary Set with 2 BCV-Clave®, Clave® Clear, Remv 2 Gang Clave® Stopcock, Clave® Stopcock, NanoClave® T-Connector, 2 Ext, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

A1010 108 13.30 25

Description 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Quadfuse Ext Set with 3 MicroClave Clear® (Yellow,Green Rings), Anti-Siphon Valve, 3-0.2 Micron Filters, 1.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing

Description 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Trifuse Ext Set with 2 MicroClave Clear® (Yellow, Green Rings), Anti-Siphon Valve, 3 Clamps, 2-0.2 Micron Filter, 1.2 Micron Filter, Rotating Luer, Non-DEHP Tubing

Description 128” (325 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Bifuse Ext Set with MicroClave Clear® (Green Ring), Anti-Siphon Valve, 0.2 Micron Filter, Rotating Luer, Non-DEHP Tubing

Description: 127” (323 cm) Transfer Set with MicroClave® T-Connector, Check Valve, Smallbore Quadfuse Ext Set with 3 MicroClave® Clear (Yellow, Green Rings), Anti-Siphon Valve, 2-0.2 Micron Filter, 1.2 Micron Filter, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33334 127 12.20 50

Item Length (in.) Priming volume (mL) Case Qty

MC33333 127 11.80 50

Item Length (in.) Priming volume (mL) Case Qty

MC33332 128 11.40 50

Item Length (in.) Priming volume (mL) Case Qty

MC33331 127 11.85 50

Extension Sets

Description 8” (20 cm) Smallbore Ext Set with 2 NanoClave®, Clamp, Rotating Luer, Non-DEHP Tubing

Description 7” (18 cm) Smallbore Ext Set with MicroClave® Clear, Clamp, Rotating Luer, Non-DEHP Tubing

Description 4.5” (11 cm) Smallbore Ext Set with MicroClave® Clear, Clamp, Rotating Luer, Non-DEHP Tubing

Description 4” (10 cm) Smallbore Ext Set with NanoClave®, Clamp, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

A1061 8 0.34 50

Item Length (in.) Priming volume (mL) Case Qty

MC3302 7 0.24 50

Item Length (in.) Priming volume (mL) Case Qty

MC33191 4.5 0.18 50

Item Length (in.) Priming volume (mL) Case Qty

A1063 4 0.18 50

Page 5: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

0,2 µm

OFF

FLUJO

FLOW

Extension Sets (Cont)

Bifuse Extension Sets

Item Length (in.) Priming volume (mL) Case Qty

B33357 72 1.10 50

Description 72” (183 cm) Smallbore Ext Set with 4-Way Stopcock, 2 MicroClave®, Anti-Siphon Valve, Clamp, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33129 4 0.24 50

Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear, 2 Clamps, Rotating Luer, Non-DEHP Tubing

Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 NanoClave®, 2 Clamps, Rotating Luer, Non-DEHP Tubing

Description 7” (18 cm) Smallbore Ext Set with MicroClave® Clear (Green Ring), 0.2 Micron Filter, Clamp, Rotating Luer, Non DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

A1064 4 0.29 50

Item Length (in.) Priming volume (mL) Case Qty

A1014 8 0.51 50

Description 8” (20 cm) Smallbore Ext Set with MicroClave® Clear, 0.2 Micron Filter, NanoClave® T-Connector, Clamp, Rotating Luer, Non-DEHP Tubing

Description 33” (84 cm) Ext Set with 2 Clave® Clear, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33386 33 4.40 50

Item Length (in.) Priming volume (mL) Case Qty

MC33335 7 0.41 50

Description 7’’ (18 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear, Check Valve, 2 Clamps, Rotating Luer, Non-DEHP Tubing

Description 9” (23 cm) Smallbore Bifuse Ext Set with 3 NanoClave®, 3 Clamps, 0.2 Micron Filter, Rotating Luer, Non-DEHP Tubing

Description 4” (10 cm) Smallbore Bifuse Ext Set with 2 MicroClave® Clear (Green, Yellow Rings), 2 Clamps, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33576 7 0.49 50

Item Length (in.) Priming volume (mL) Case Qty

A1062 9 0.70 50

Item Length (in.) Priming volume (mL) Case Qty

MC33375 4 0.24 50

Page 6: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

Item Length (in.) Priming volume (mL) Case Qty

A1065 4 0.47 50

Description 4” (10 cm) Smallbore Trifuse Ext Set with 3 NanoClave®, 3 Clamps, Rotating Luer, Non-DEHP Tubing

Trifuse Extension Sets

Item Length (in.) Priming volume (mL) Case Qty

MC33098 4 0.40 50

Description 4” (10 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 3 Clamps, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

A1013 10 2.9 50

Description 10” (25 cm) Trifuse Ext Set with 3 MicroClave® Clear, Tri-Connector, NanoClave® T-Connector, 4 Clamps (Red, White, Blue), Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33192 6 0.39 50

Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Red, Green Ring), Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33377 5.5 .21 50

Description 5.5” (14 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Glow, Green, Yellow Rings), 4 Clamps, Rotating Luer, Non-DEHP Tubing

Description 7” (18 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 2 Check Valve, 3 Clamps, Rotating Luer, Non-DEHP Tubing

Description 7” (18 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear (Red, Glow Rings), 0.2 Micron Filter, 3 Clamps (Red, White, Blue), Rotating Luer, Non-DEHP Tubing

Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, Check Valve, 3 Clamps, Rotating Luer, Non-DEHP Tubing

Description 6” (15 cm) Smallbore Trifuse Ext Set with 3 MicroClave® Clear, 3 Clamps, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

MC33577 7 0.80 50

Item Length (in.) Priming volume (mL) Case Qty

MC33193 7 0.70 50

Item Length (in.) Priming volume (mL) Case Qty

MC33575 6 0.62 50

Item Length (in.) Priming volume (mL) Case Qty

MC33194 6 0.48 50

Page 7: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

Item Length (in.) Priming volume (mL) Case Qty

MC33340 6 1.40 50

Description 6” (15 cm) Smallbore Quadfuse Ext Set with 4 MicroClave® Clear (Yellow,3 Green Rings), 3-0.2 Micron Filters, 1.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing

Quadfuse Extension Sets

Item Length (in.) Priming volume (mL) Case Qty

A1066 4 0.57 50

Description 4” (10 cm) Smallbore Quadfuse Ext Set with 4 NanoClave®, 4 Clamps, Rotating Luer, Non-DEHP Tubing

Item Length (in.) Priming volume (mL) Case Qty

A1067 9 1.00 50

Description 9” (23 cm) Smallbore Quadfuse Ext Set with 5 NanoClave®, 0.2 Micron Filter, 4 Clamps, Rotating Luer, Non-DEHP Tubing

Page 8: Custom IV Sets & Connectors - ICU Medical€¦ · Why settle for stock IV sets for your NICU and PICU when ICU Medical lets you create your own custom configurations for your specific

FLUJOFLOW

FLUJO

FLOW

Want to create a custom set to meet a specific clinical need? Contact your local ICU Medical representative.

800.824.7890 | www.icumed.com©2013 ICU Medical Inc. | M1-1370 Rev. 03

“ Following the switch to MicroClave connectors and the implementation of a new closed IV system and smart infusion devices, infection rates were reduced by 60 percent and medication errors decreased by 54 percent. Much of this error reduction was ascribed to the use of the closed system, which ensures that nurses deliver intermittent IV medications via a single, consistent method.”Tanner J, Developing a Closed, Intravenous Medication System for a Neonatal Intensive Care Unit. Neonatal Intensive Care Journal, July–August 2012. (Set featured above.)

> Optimize and tightly control fluid volumes

> Standardize your process

> Help foster nursing compliance

The right closed IV administration system can provide the clinical benefits of continuous and scheduled medication delivery, while limiting your administration technique to a single delivery method with the fewest connections possible.

Learn how custom closed IV administration systems can improve patient care and reduce infection rates in neonatal and pediatric ICUs.

1 Ryder M, James G, Pulchini E, Bickle L, Parker A. Differences in bacterial transfer and fluid path colonization through needlefree connector-catheter systems in vitro. Presented at the Infusion Nursing Society Meeting, May 2011. 2 Moore C, RN, MBA, CIC. Maintained Low Rate of Catheter-Related Bloodstream Infections (CR-BSIs) After Discontinuation of a Luer Access Device (LAD) at an Academic Medical Center. Poster presented at the annual Association for Professionals in Infection Control and Epidemiology (APIC) Conference 2010, Abstract 4-028. 3 Global Healthcare Exchange(GHX) Market Intelligence data. Connectors, Needleless, Parenterals, [92-100]. Q1-Q4 2012. Includes stand-alone needlefree connectors and ancillary direct access devices (two-piece, hemodialysis, non-swab-able, and non-patient contact connectors excluded). 4Breznock E M, DVM, PhD, Diplomate ACVS, Sylvia C J, DVM, MS., BioSurg, Inc. The in vivo evaluation of the flushing efficiency of different designs of clear needlefree connectors, March 2011.