GENERAL NOTES1. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED
DIMENSIONS. DO NOT SCALE THE DRAWINGS.2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES LISTED.3. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS UNLESS NOTED OTHERWISE.4. ALL ELECTRICAL AND PLUMBING WORK SHALL BE INSTALLED BY LICENSED
PROFESSIONAL(S) AND SHALL CONFORM WITH CURRENT CODES.5. CONFIRM AND COORDINATE LOCATIONS OF ALL UTILITIES WITH
CONTRACTOR.6. CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY OF ANY
DESCREPENCIES IN THE DRAWINGS.
INFORMATION CONTAINED IN THIS DRAWING SET HAS BEEN PREPARED FOR THEUSE OF A PROFESSIONAL, LICENSED CONTRACTOR WHO IS FAMILIAR WITHBUILDING CODE AND OTHER LEGAL REQUIREMENTS WITHIN THE PROJECT'SJURISDICTION. NO WARRANTIES, EXPRESSED OR IMPLIED, ARE GIVEN ORINTENDED BY THE PREPARATION OF THESE DRAWINGS.
ADOPTED CODES:2012 INTERNATIONAL RESIDENTIAL CODE 2012 UNIFORM PLUMBING CODE2012 INTERNATIONAL MECHANICAL CODE 2014 NATIONAL ELECTRIC CODE2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY
CONSERVATION CODE (IECC)
CO
NC
RETE
APR
ON
PER
C.O
.B.S
TAN
DA
RDD
WG
0252
9-11
CO
NC
RETE
PATI
O
WATER SERVICE LINE-CONFIRM LOCATION
SEWER SERVICE LINE-LOCATION T.B.D.
BOU
LEV
ARD
TREE
-PER
SUBD
IVIS
ION
STA
ND
ARD
S
CO
NC
RETE
SID
EWA
LK
SOD TYP.
CO
NC
RETE
DRI
VE
&A
PRO
N
GU
TTER
CONT. RIDGE VENT, TYP.
ALL LANDSCAPING SHALL BEINSTALLED PER SUBDIVISIONREQUIREMENTS, TYPICAL
NOTE: CONTRACTORRESPONSIBLE FOR VERIFYINGUTILITY/ SERVICE LOCATIONS
LOT SHALL BE GRADED TODRAIN SURFACE WATER AWAYFROM FOUNDATION WALLS.THE GRADE SHALL FALL AMINIMUM OF 6 INCHES WITHINTHE FIRST 10 FEET PER IRC R401.3
INSTALL SPARK ARRESTORPER IRC R1001.6.1
PROVIDE & INSTALL RAINGUTTERS & DOWNSPOUTS PEROWNER OR BUILDER DISCRETION
6"
/12"
6"
/12"
6" / 12"6" / 12"
6"
/12"
54'-
0"
31'-
6"
6"
/12"
6" / 12"
SID
EWA
LKTO
BEA
MIN
.O
F6"
@D
RIV
EWA
Y
GAS SERVICE
ELECTRICAL SERVICE
CO
NT.
RID
GE
VEN
T,TY
P.
GUTTER
GUTTER
GUTTER
GU
TTER
GU
TTER
GU
TTER
GUTTER
1' - 6"
1'-6
"
1'-6
"
1' - 6"
1' - 6"
1'-6
"
1'-6
"
SOD TYP.
BOU
LEV
ARD
TREE
-PER
SUBD
IVIS
ION
STA
ND
ARD
S
115.00'PROPERTY LINE
115.01'PROPERTY LINE
112.
88'
PRO
PERT
YLI
NE
111.
62'
PRO
PERT
YLI
NE
ELECT. BOX
20'-
0"
10' - 0"
CO
R NE R
S ETB
AC
K
15'-
0"
UT I
LIT Y
E AS E
MEN
T
10'-
0"UTILITY EASEMENT
10' - 0"
FRONT SETBACK
25' - 0"
REAR SETBACK
20' - 0"
SID
ESE
TBA
CK
8'-0
"
26' - 6"
18'-
6"
34' - 6"
PENWELL BRIDGE ROAD
PPO
WER
SBL
VD
.
DRAINAGE DITCHDO NOT FILL OR OBSTRUCT THE FLOW
MAINUTILITYBOX
CONSTRUCTION NOTES1. ALL LUMBER IN CONTACT w/ CONCRETE or MASONRY or WITHIN 8" OF
GRADE SHALL BE PRESSURE TREATED.2. FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10
FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8).3. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT,
FURNISHINGS, ETC.4. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS
WITH PLUMBING- FRAMING CONTRACTOR TO VERIFY.5. CONTRACTOR SHALL VERIFY FLOOR JOISTS FOR DESIRED FLOOR STIFFNESS,
TYP.6. GARAGE SHALL HAVE 5/8" TYPE 'X' GYP BD AT CEILING AND 1/2" GYP BD
AT WALLS, UNLESS NOTED OTHERWISE.7. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE.8. PROVIDE SELF-ADHERING ICE AND WATER PROTECTION MEMBRANE AT
ALL EAVES TO A POINT 24" INSIDE THE EXTERIOR WALL FACE.9. WINDOWS IDENTIFIED AS "EGRESS" SHALL HAVE MINIMUM CLEAR WIDTH
OF 20", MINIMUM CLEAR HEIGHT OF 22", AND MINIMUM CLEAR AREA OF5.7 SQ FT. SILL HEIGHT TO BE 44" MAXIMUM ABOVE FLOOR.
10. ALL PENETRATIONS GREATER THAN 100 SQ INCHES IN COMMON/SHAREDGARAGE WALL SHALL BE UL1479 LISTED, UNLESS NOTED OTHERWISE.
11. CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS,UNLESS NOTED OTHERWISE.
12. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/8" MINIMUM TO 1/4" MAXIMUMOPENINGS.
13. FURNACE MUST BE LOCATED WITHIN 20' OF CRAWL SPACE ACCESS IFINSTALLED IN CRAWL SPACE. PROVIDE 27 SQ INCHES COMBUSTION FLUETO OUTSIDE, SUSPEND 6" MIN. ABOVE GRADE (ASSUMED 80k BTU/H)
14. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR,IN WALLS CONTAINING SHOWERS AND BATHTUBS, WHERE AN INDIVIDUALPANE IS LARGER THAN 9 SQUARE FEET, AND ANY GLAZING WHERE THEBOTTOM EDGE IS LESS THAN 18" ABOVE THE ADJACENT WALKINGSURFACE SHALL BE SAFETY GLAZING.
15. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE w/ IRCSECTION R316
1. EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2x6 STUDS @ 16" o.c.WITH R-21 INSULATION, UNLESS NOTED OTHERWISE. ALL EXTERIORSHEATHING TO BE 1/2" NOMINAL CONTINUOUS STRUCTURAL RATEDPANEL.
2. INTERIOR WALLS SHALL BE CONSTRUCTED OF 2x4 STUDS @ 16" o.c.,UNLESS NOTED OTHERWISE. PROVIDE 2x6 WALLS AT ALL POCKETDOORS. INTERIOR WALLS TO RECEIVE 1/2" GYP BD, UNLESS NOTEDOTHERWISE.
3. FLOOR JOISTS TO BE 11-7/8" TJI 210 @ 19.2" o.c. WITH 1-3/4"MIN BEARING, UNLESS NOTED OTHERWISE
4. FLOOR DECK TO BE 3/4" TONGUE-AND-GROOVE, STRUCTURALRATED PANEL (48/24 CDX) UNLESS NOTED OTHERWISE.
5. ALL LUMBER SHALL BE NO. 2 GRADE OR BETTER.6. ALL HEADERS (6' MAX SPAN) AT EXTERIOR WALLS SHALL BE (2) 2x10
HF#2 OR BETTER w/ (2) JACK STUDS AT EACH END, UNLESS NOTEDOTHERWISE.
7. PROVIDE BLOCKING BETWEEN TRUSSES AT ALL BEARING LOCATIONS.
STRUCTURAL NOTES
ALL LANDSCAPING SHALL BEINSTALLED PER SUBDIVISIONREQUIREMENTS, TYPICAL
ALL SOD & PLANTING BEDSSHALL BE IRRIGATED WITHTIMED IRRIGATION SYSTEM
CONCRETE PATIO
BOU
LEV
ARD
TREE
-PER
SUBD
IVIS
ION
STA
ND
ARD
SSO
DBL
VD
.
SOD TYP.
SOD TYP.
BOU
LEV
ARD
TREE
-PER
SUBD
IVIS
ION
STA
ND
ARD
S
WATER SERVICE LINE- CONFIRMLOCATION
SEWER SERVICE LINE- LOCATION T.B.D.
GAS SERVICE
31'-
6"
20'-
0"
ELECTRICAL SERVICE
115.00'PROPERTY LINE
115.01'PROPERTY LINE
112.
88'
PRO
PERT
YLI
NE
111.
62'
PRO
PERT
YLI
NE
ELECT. BOX
CO
RNE R
S ETB
AC
K
15'-
0"
UT I
LIT Y
E AS E
MEN
T
10'-
0"
UTILITY EASEMENT
10' - 0"
REAR SETBACK
20' - 0"
PENWELL BRIDGE ROAD
PPO
WER
SBL
VD
.
MAINUTILITYBOX
DRAINAGE DITCHDO NOT FILL OR OBSTRUCT THE FLOW
PLANT LEGENDSPECIES
GREEN ASH, ELM, LINDENBOULEVARD TREE
CANADA RED, CRAB APPLEYARD TREE
LILAC, DOGWOODBUSH
JUNIPER, EVERGREENSHRUBS
POTENTILLA SHRUB
SOD
PLANTING BED (WASHED 1 1/2"MINUS ROCK) W/ PLASTIC ORMETAL EDGING
SPIRALIS
1/8" = 1'-0"1
SITE PLAN
DRAWING NUMBER:
PHASE:
DATE:
DRAWING TITLE:
PROJECT NUMBER:
DRAWN BY / CHECKED BY:
REVISIONS:
0"1"
2"11/1
2/2
015
9:3
9:3
2A
M
1710 POWERS BLVDBLOCK 4, LOT 2
RYEN GLENNBELGRADE MT
A1.1
SITE PLAN
15.066
BEN NISTLER406-570-7345PLAN NAME:MOONLIGHT
NOVEMBER 12, 2015
EML STH
CONSTRUCTION
1/16" = 1'-0"2
LANDSCAPE PLAN
NO. DESCRIPTION DATE
WH
W D
FD
DW
REF.
CONSTRUCTION NOTES1. ALL LUMBER IN CONTACT w/ CONCRETE or MASONRY or WITHIN 8" OF
GRADE SHALL BE PRESSURE TREATED.2. FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10
FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8).3. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT,
FURNISHINGS, ETC.4. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS
WITH PLUMBING- FRAMING CONTRACTOR TO VERIFY.5. CONTRACTOR SHALL VERIFY FLOOR JOISTS FOR DESIRED FLOOR STIFFNESS,
TYP.6. GARAGE SHALL HAVE 5/8" TYPE 'X' GYP BD AT CEILING AND 1/2" GYP BD
AT WALLS, UNLESS NOTED OTHERWISE.7. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE.8. PROVIDE SELF-ADHERING ICE AND WATER PROTECTION MEMBRANE AT
ALL EAVES TO A POINT 24" INSIDE THE EXTERIOR WALL FACE.9. WINDOWS IDENTIFIED AS "EGRESS" SHALL HAVE MINIMUM CLEAR WIDTH
OF 20", MINIMUM CLEAR HEIGHT OF 22", AND MINIMUM CLEAR AREA OF5.7 SQ FT. SILL HEIGHT TO BE 44" MAXIMUM ABOVE FLOOR.
10. ALL PENETRATIONS GREATER THAN 100 SQ INCHES IN COMMON/SHAREDGARAGE WALL SHALL BE UL1479 LISTED, UNLESS NOTED OTHERWISE.
11. CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS,UNLESS NOTED OTHERWISE.
12. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/8" MINIMUM TO 1/4" MAXIMUMOPENINGS.
13. FURNACE MUST BE LOCATED WITHIN 20' OF CRAWL SPACE ACCESS IFINSTALLED IN CRAWL SPACE. PROVIDE 27 SQ INCHES COMBUSTION FLUETO OUTSIDE, SUSPEND 6" MIN. ABOVE GRADE (ASSUMED 80k BTU/H)
14. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR,IN WALLS CONTAINING SHOWERS AND BATHTUBS, WHERE AN INDIVIDUALPANE IS LARGER THAN 9 SQUARE FEET, AND ANY GLAZING WHERE THEBOTTOM EDGE IS LESS THAN 18" ABOVE THE ADJACENT WALKINGSURFACE SHALL BE SAFETY GLAZING.
15. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE w/ IRCSECTION R316
GENERAL NOTES1. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED
DIMENSIONS. DO NOT SCALE THE DRAWINGS.2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES LISTED.3. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS UNLESS NOTED OTHERWISE.4. ALL ELECTRICAL AND PLUMBING WORK SHALL BE INSTALLED BY LICENSED
PROFESSIONAL(S) AND SHALL CONFORM WITH CURRENT CODES.5. CONFIRM AND COORDINATE LOCATIONS OF ALL UTILITIES WITH
CONTRACTOR.6. CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY OF ANY
DESCREPENCIES IN THE DRAWINGS.
INFORMATION CONTAINED IN THIS DRAWING SET HAS BEEN PREPARED FOR THEUSE OF A PROFESSIONAL, LICENSED CONTRACTOR WHO IS FAMILIAR WITHBUILDING CODE AND OTHER LEGAL REQUIREMENTS WITHIN THE PROJECT'SJURISDICTION. NO WARRANTIES, EXPRESSED OR IMPLIED, ARE GIVEN ORINTENDED BY THE PREPARATION OF THESE DRAWINGS.
ADOPTED CODES:2012 INTERNATIONAL RESIDENTIAL CODE 2012 UNIFORM PLUMBING CODE2012 INTERNATIONAL MECHANICAL CODE 2014 NATIONAL ELECTRIC CODE2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY
CONSERVATION CODE (IECC)
A3.12
A3.1
3
A3.1 1
A3.1
4
ELECTRIC WATER HEATER(CONTRACTOR TO CONFIRMSIZE)- SECURE w/ STRAPS
PROVIDE GALV PAN w/ 3/4"DRAIN
UFER GROUND
ELECT SERVICE(200A) w/ 30x36CLEAR WORKAREA
22x30 ATTICACCESS
KITCHEN DESIGNBY OTHERS
GAS FIREPLACEw/ DIRECT VENT
16" RAISEDHEARTH
MAIN (HEATED): 1553 SF GROSS (INC. EXT. WALLS)GARAGE: 739 SF NET
ELECT SERVICE w/30x36 CLEAR WORKAREA
GAS SERVICE
1/2" GYP BD @ GARAGEWALLS- TYP
1/2" TYPE "X" GYP BD @GARAGE CEILING- TYP
ALL PENETRATIONS GREATER THAN100 SQ INCHES INCOMMON/SHARED GARAGEWALL SHALL BE UL1479 LISTED- TYP
6X6 DFPOST, TYP.
SIMPSON LSTA15 @ EASIDE- TYP @ POST/BEAMCONNECTIONS
ELEVATE WATER HEATER 18"MINIMUM ABOVE GARAGESLAB TO ANY ELEMENT ORSWITCH THAT MAY SPARK
CHIMNEY FRAMING- PROVIDE 1"CLEARANCE FROM FLUE TO COMBUSTIBLEMATERIAL
10'-
0"24
'-0"
6'-0
"12
'-0"
2'-0
"
50' - 0"
10'-
0"16
'-4"
15'-
8"12
'-0"
6' - 1" 2' - 0" 22' - 0" 24' - 0"
21' - 0"3' - 0"6' - 4"3' - 8"5' - 10"6' - 2"8' - 0"
11' - 0" 11' - 0" 6' - 0" 6' - 0" 12' - 0"
5'-1
0"3'
-8"
2'-1
0"4'
-0"
5'-4
"2'
-4"
11' - 10" 2' - 2" 6' - 0" 10' - 0" 10' - 0" 10' - 0" 3' - 9"
3'-0
"3'
-0"
36" x 80"20 MIN- SELF
CLOSING
4'-8
"5'
-4"
8'-2
"8'
-2"
3'-6
"5'
-6"
6'-8
"3'
-9"
12'-
0"12
'-0"
4'-1
0"5'
-2"
739 SF
GARAGE
MSTR BEDROOM11'-6" x 15'-7"
MSTR CLOSET5'-8" x 8'-7"
BEDROOM 19'-8" x 12'-0"
BEDROOM 211'-4" x 11'-1"
MSTR BATH5'-8" x 11'-0"
LAUNDRY5'-6" x 6'-6"
BATHROOM5'-3" x 9'-5"
36" x 80"
3'-8
"6'
-2"
30x30 CRAWLSPACE ACCESS
DINING9'-6" x 12'-0"
KITCHEN10'-0" x 14'-8"
LIVING ROOM20'-6" x 15'-2"
STH D14 HOLDDOWNS, TYP.
STH D14 HOLDDOWNS, TYP.
STH D14 HOLDDOWNS, TYP.
SDCMD
SDCMD
SDCMD
SDCMD
SDCMD
ROD & SHELF
ROD
&SH
ELF
ROD & SHELF
CABINETS ABOVE
ROD
&SH
ELF
16'-0
"Wx
7'-0
"H
8'-0
"Wx
7'-0
"H
36" x 80"
30" x 80"
24" x 80"
36"x
80"
POC
KET 30" x 80"
72"x
80"
SLID
ER
60" X 48"SLIDEREGRESS
(7' - 0") HEAD
60" x 80"BIFOLD
30" x 80"
30"x
80"
72"x
80"
BIFO
LD
60"X
48"
SLID
EREG
RESS
(7'-
0")
HEA
D
36" x 80"
30" x 80"
60"X
48"
SLID
EREG
RESS
(7'-
0")
HEA
D
96"X
60"
(7'-
0")
HEA
D
6X6 DFPOST, TYP.
SIMPSON LSTA15 @ EASIDE- TYP @ POST/BEAMCONNECTIONS
2'-4
"5'
-2"
12' - 0"
4' - 0"
5' - 2"4' - 10"5' - 2"4' - 10"
6'-0
"6'
-0"
6' - 0"6' - 0"4' - 5"1' - 7"
48" X 24"FIXED
(7' - 0") HEAD
24" X 36"AWNING
(7' - 0") HEAD
48" X 48"SLIDER
(7' - 0") HEAD
60" X 48"SLIDER
(7' - 0") HEAD
OPTIONAL
5'-0
"
INSULATION REQUIREMENTSCONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE INACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC) INCLUDING MONTANA AMENDMENTS.
APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS:CEILING: R-49 (UNCOMPRESSED R-38 ALLOWED AT EAVES)EXTERIOR WALL: R-21 (or R-13 + R-5 CONTINUOUS INSULATION)BASEMENT WALL: R-19 (or R-15 CONTINUOUS INSULATION) - SEE NOTE ASLAB PERIMETER: R-10 (or R-15 IF HEATED SLAB)CRAWLSPACE WALL: R-19 (or R-15 CONTINUOUS INSULATION)WINDOW / DOOR: U-0.32 (R-3)
NOTE A: RES-CHECK ANALYSIS MAY ALLOW LOWER R-VALUE (R-10 MINIMUM)
BRACED PANEL SCHEDULETYPE SUPPORTS FASTENERS SPACINGA. STUDS @ 16" o.c. 8d NAILS 6" o.c. (EDGE) & 12" o.c. (FIELD)B. STUDS @ 16" o.c. MAX 1-1/4" SCREWS 4" o.c. (EDGE) & 8" o.c. (FIELD)C. STUDS @ 16" o.c. MAX 1-1/4" SCREWS 4" o.c. (EDGE) & 8" o.c. (FIELD)
ALL BRACED WALLS SHALL BE TYPE 'A' - UNLESS NOTED OTHERWISEMINIMUM REQUIRED LENGTH OF BRACED WALL PANEL NOTED ON PLAN(PER SECTION R602.10).
TYPE ATYPE B - 1/2" GWB - BOTH SIDESTYPE C - 1/2" GWB - ONE SIDE
1/2" NOMINAL OSB
NOTE: CONNECT ALL INTERIOR BRACED WALL PANELS TO STRUCTURALFRAMING IN ACCORDANCE w/ R602.10.6 & TABLE R602.3(1). PROVIDEFULL HEIGHT BLOCKING AS NEEDED.
ONE SIDE
BEAM SCHEDULERB1 XXX
1. EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2x6 STUDS @ 16" o.c.WITH R-21 INSULATION, UNLESS NOTED OTHERWISE. ALL EXTERIORSHEATHING TO BE 1/2" NOMINAL CONTINUOUS STRUCTURAL RATEDPANEL.
2. INTERIOR WALLS SHALL BE CONSTRUCTED OF 2x4 STUDS @ 16" o.c.,UNLESS NOTED OTHERWISE. PROVIDE 2x6 WALLS AT ALL POCKETDOORS. INTERIOR WALLS TO RECEIVE 1/2" GYP BD, UNLESS NOTEDOTHERWISE.
3. FLOOR JOISTS TO BE 11-7/8" TJI 210 @ 19.2" o.c. WITH 1-3/4"MIN BEARING, UNLESS NOTED OTHERWISE
4. FLOOR DECK TO BE 3/4" TONGUE-AND-GROOVE, STRUCTURALRATED PANEL (48/24 CDX) UNLESS NOTED OTHERWISE.
5. ALL LUMBER SHALL BE NO. 2 GRADE OR BETTER.6. ALL HEADERS (6' MAX SPAN) AT EXTERIOR WALLS SHALL BE (2) 2x10
HF#2 OR BETTER w/ (2) JACK STUDS AT EACH END, UNLESS NOTEDOTHERWISE.
7. PROVIDE BLOCKING BETWEEN TRUSSES AT ALL BEARING LOCATIONS.
STRUCTURAL NOTES
DRAWING NUMBER:
PHASE:
DATE:
DRAWING TITLE:
PROJECT NUMBER:
DRAWN BY / CHECKED BY:
REVISIONS:
0"1"
2"11/1
2/2
015
9:3
9:3
3A
M
1710 POWERS BLVDBLOCK 4, LOT 2
RYEN GLENNBELGRADE MT
A2.1
MAIN FLOOR
15.066
BEN NISTLER406-570-7345PLAN NAME:MOONLIGHT
NOVEMBER 12, 2015
EML STH
CONSTRUCTION
1/4" = 1'-0"1
1.0 MAIN LEVEL
NO. DESCRIPTION DATE
GENERAL NOTES1. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED
DIMENSIONS. DO NOT SCALE THE DRAWINGS.2. ALL WORK SHALL COMPLY WITH APPLICABLE CODES LISTED.3. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS UNLESS NOTED OTHERWISE.4. ALL ELECTRICAL AND PLUMBING WORK SHALL BE INSTALLED BY LICENSED
PROFESSIONAL(S) AND SHALL CONFORM WITH CURRENT CODES.5. CONFIRM AND COORDINATE LOCATIONS OF ALL UTILITIES WITH
CONTRACTOR.6. CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY OF ANY
DESCREPENCIES IN THE DRAWINGS.
INFORMATION CONTAINED IN THIS DRAWING SET HAS BEEN PREPARED FOR THEUSE OF A PROFESSIONAL, LICENSED CONTRACTOR WHO IS FAMILIAR WITHBUILDING CODE AND OTHER LEGAL REQUIREMENTS WITHIN THE PROJECT'SJURISDICTION. NO WARRANTIES, EXPRESSED OR IMPLIED, ARE GIVEN ORINTENDED BY THE PREPARATION OF THESE DRAWINGS.
ADOPTED CODES:2012 INTERNATIONAL RESIDENTIAL CODE 2012 UNIFORM PLUMBING CODE2012 INTERNATIONAL MECHANICAL CODE 2014 NATIONAL ELECTRIC CODE2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY
CONSERVATION CODE (IECC)
CONSTRUCTION NOTES1. ALL LUMBER IN CONTACT w/ CONCRETE or MASONRY or WITHIN 8" OF
GRADE SHALL BE PRESSURE TREATED.2. FIREBLOCKING TO BE INSTALLED IN ALL WALL CAVITIES GREATER THAN 10
FEET TALL AND AS APPLICABLE PER CODE REQUIREMENTS (R602.8).3. PROVIDE BLOCKING AS NEEDED FOR ALL WALL MOUNTED EQUIPMENT,
FURNISHINGS, ETC.4. CONFIRM STARTING POINT OF FLOOR FRAMING TO REDUCE CONFLICTS
WITH PLUMBING- FRAMING CONTRACTOR TO VERIFY.5. CONTRACTOR SHALL VERIFY FLOOR JOISTS FOR DESIRED FLOOR STIFFNESS,
TYP.6. GARAGE SHALL HAVE 5/8" TYPE 'X' GYP BD AT CEILING AND 1/2" GYP BD
AT WALLS, UNLESS NOTED OTHERWISE.7. INTERIOR CEILINGS TO RECEIVE 5/8" GYP BD, UNLESS NOTED OTHERWISE.8. PROVIDE SELF-ADHERING ICE AND WATER PROTECTION MEMBRANE AT
ALL EAVES TO A POINT 24" INSIDE THE EXTERIOR WALL FACE.9. WINDOWS IDENTIFIED AS "EGRESS" SHALL HAVE MINIMUM CLEAR WIDTH
OF 20", MINIMUM CLEAR HEIGHT OF 22", AND MINIMUM CLEAR AREA OF5.7 SQ FT. SILL HEIGHT TO BE 44" MAXIMUM ABOVE FLOOR.
10. ALL PENETRATIONS GREATER THAN 100 SQ INCHES IN COMMON/SHAREDGARAGE WALL SHALL BE UL1479 LISTED, UNLESS NOTED OTHERWISE.
11. CONCRETE SIDEWALKS TO HAVE TOOLED 3/4" JOINT AT 5' INTERVALS,UNLESS NOTED OTHERWISE.
12. ATTIC VENTILATION OPENINGS SHALL BE COVERED WITH CORROSION-RESISTANT METAL MESH WITH 1/8" MINIMUM TO 1/4" MAXIMUMOPENINGS.
13. FURNACE MUST BE LOCATED WITHIN 20' OF CRAWL SPACE ACCESS IFINSTALLED IN CRAWL SPACE. PROVIDE 27 SQ INCHES COMBUSTION FLUETO OUTSIDE, SUSPEND 6" MIN. ABOVE GRADE (ASSUMED 80k BTU/H)
14. ALL GLAZING WITHIN A DOOR PANEL, WITHIN 24" OF A SWINGING DOOR,IN WALLS CONTAINING SHOWERS AND BATHTUBS, WHERE AN INDIVIDUALPANE IS LARGER THAN 9 SQUARE FEET, AND ANY GLAZING WHERE THEBOTTOM EDGE IS LESS THAN 18" ABOVE THE ADJACENT WALKINGSURFACE SHALL BE SAFETY GLAZING.
15. SPRAY FOAM INSULATION SHALL BE PROTECTED IN ACCORDANCE w/ IRCSECTION R316
INSULATION REQUIREMENTSCONTRACTOR SHALL BE RESPONSIBLE FOR INSULATING THE RESIDENCE INACCORDANCE WITH THE 2012 INTERNATIONAL ENERGY CONSERVATION CODE(IECC) INCLUDING MONTANA AMENDMENTS.
APPLICABLE PRESCRIPTIVE PATH REQUIREMENTS:CEILING: R-49 (UNCOMPRESSED R-38 ALLOWED AT EAVES)EXTERIOR WALL: R-21 (or R-13 + R-5 CONTINUOUS INSULATION)BASEMENT WALL: R-19 (or R-15 CONTINUOUS INSULATION) - SEE NOTE ASLAB PERIMETER: R-10 (or R-15 IF HEATED SLAB)CRAWLSPACE WALL: R-19 (or R-15 CONTINUOUS INSULATION)WINDOW / DOOR: U-0.32 (R-3)
NOTE A: RES-CHECK ANALYSIS MAY ALLOW LOWER R-VALUE (R-10 MINIMUM)
FOUNDATION NOTES
1. SOILS ENGINEER TO REVIEW SOIL CONDITIONS FOLLOWING EXCAVATION ANDVERIFY FOOTING DESIGN (DESIGN ASSUMES 2500 PSI).
2. SOILS ENGINEER TO PERFORM INSPECTION AND PROVIDE APPROVAL OF THEFOUNDATION DESIGN PRIOR TO CITY PERMIT INSPECTION.
3. FOOTINGS ARE TO BEAR ON UNDISTURBED, LEVEL SOIL DEVOID OF ANYORGANIC MATERIAL.
4. STEP FOOTINGS AS NEEDED TO MAINTAIN REQUIRED DEPTH BELOW FINALGRADE.
5. ALL GRANULAR FILL SHALL BE COMPACTED TO 95% DENSITY, UNLESS NOTEDOTHERWISE.
6. SLOPE FLOOR OF GARAGE TO OPENING(S) AT 1/8" PER FOOT MINIMUM.7. CONCRETE SLABS ON GRADE SHALL HAVE CONTROL JOINTS AT MIMIMUM 12'
INTERVALS EACH WAY, UNLESS NOTED OTHERWISE.8. REINFORCING STEEL SHALL BE A-615 GRADE 60. PROVIDE MINIMUM 40 BAR
DIAMETER LAP AT SPLICES, CORNERS, AND INTERSECTIONS.9. DAMPPROOF FOUNDATION BEFORE BACKFILLING.10. FINAL GRADE SHALL BE SLOPED AWAY FROM STRUCTURE AT 2% MINIMUM FOR
5' MINIMUM AT FOUNDATION PERIMETER.
BRACED PANEL SCHEDULETYPE SUPPORTS FASTENERS SPACINGA. STUDS @ 16" o.c. 8d NAILS 6" o.c. (EDGE) & 12" o.c. (FIELD)B. STUDS @ 16" o.c. MAX 1-1/4" SCREWS 4" o.c. (EDGE) & 8" o.c. (FIELD)C. STUDS @ 16" o.c. MAX 1-1/4" SCREWS 4" o.c. (EDGE) & 8" o.c. (FIELD)
ALL BRACED WALLS SHALL BE TYPE 'A' - UNLESS NOTED OTHERWISEMINIMUM REQUIRED LENGTH OF BRACED WALL PANEL NOTED ON PLAN(PER SECTION R602.10).
TYPE ATYPE B - 1/2" GWB - BOTH SIDESTYPE C - 1/2" GWB - ONE SIDE
1/2" NOMINAL OSB
NOTE: CONNECT ALL INTERIOR BRACED WALL PANELS TO STRUCTURALFRAMING IN ACCORDANCE w/ R602.10.6 & TABLE R602.3(1). PROVIDEFULL HEIGHT BLOCKING AS NEEDED.
ONE SIDE
30x30 CRAWLSPACE ACCESS
11-7
/8"T
JI21
0I-J
OIS
TS@
16"o
.c.-
TYP
4' SHEAR PANEL "A"
12" dia. CONC. PIER w/ (2)#4 VERT. on 2'-0"x2'-0"x8"FOOTING w/ (3) #4 EA.WAY- TYP
SIMPSON CB66TYP. @ ALLPOSTS
24"x8" THICKENED EDGEw/ (2) #4 CONT.
BLK OUT @GARAGE DOORS-TYP
4" CONC. SLAB w/ 6x610/10 WWM- SLOPE TODOORS
2x6 TREATED PONY WALLon 16"x8" FOOTING w/ (2) #4 CONT. TYP. - PROVIDECONT. BLK'G BETWEENJOISTS
6" CONC. WALL w/ #4VERT. @ 18" o.c. AND #4HORIZ @ 18" o.c.- TYP.
16"x8" CONC. FOOTINGw/ (2) #4 CONT.- TYP.
GAS-FIRED FORCED AIR FURNACE(CONTRACTOR TO CONFIRM SIZE& LOCATION)- PROVIDECOMBUSTION FLUE TO OUTSIDE-SUSPEND 6" MIN. ABOVE GRADE
CONTRACTOR SHALL VERIFYFLOOR JOISTS FOR DESIREDFLOOR STIFFNESS, TYP.
NOTE:
1. ALL STRUCTURAL CALCULATIONS ARE THERESPONSIBILITY OF THE BUILDER. ALL STRUCTURALCOMPONENTS SHOWN INCLUDING JOISTS, BEAMS,FOUNDATION WALLS & FOOTINGS SHALL BE VERIFIED BYTHE BUILDER FOR COMPLIANCE WITH CURRENT IRCREQUIRMENTS AND AUTHORITIES HAVING JURISDICTIONPRIOR TO CONSTRUCTION.
2. BUILDER SHALL SIZE ALL CONCRETE FOUNDATIONWALLS & FOOTINGS BASED ON GEOTECHNICALENGINEER'S REPORT & RECOMMENDATIONS.
PAD FOOTINGS SHOWN ASSUME 2,500 PSF SOILBEARING PRESSURE. CONTRACTOR TO VERIFYFOOTING SIZES W/ GEOTECHNICAL REPORT,TYPICAL.
STH D14 HOLDDOWNS, TYP.
NOTE:TOP OF FOUNDATION SHALL BE 18" MIN. ABOVE TOP OF CURB
NOTE:ALL LUMBER WITHIN 8" OF GRADE OR IN CONTACTw/ CONCRETE SHALL BE TREATED
6" CONC. WALL w/ #4VERT. @ 18" o.c. AND #4HORIZ @ 18" o.c.- TYP.
16"x8" CONC. FOOTINGw/ (2) #4 CONT.- TYP.
36' - 0"14' - 0"
2'-0
"12
'-0"
6'-0
"24
'-0"
10'-
0"
24' - 0"22' - 0"
4' SHEAR PANEL "A"
6'-0
1/2"
13'-
51/
2"
4' SHEAR PANEL "A"
4' SHEAR PANEL "A"4' SHEAR PANEL "A"
11-7
/8"T
JI21
0I-J
OIS
TS@
16"o
.c.-
TYP
11-7
/8"T
JI21
0I-J
OIS
TS@
16"o
.c.-
TYP
2x6 TREATED PONY WALLon 16"x8" FOOTING w/ (2) #4 CONT. TYP. - PROVIDECONT. BLK'G BETWEENJOISTS
BLK OUT @GARAGE DOORS-TYP
BLK OUT @GARAGE DOORS-TYP
BLK OUT @GARAGE DOORS-TYP
STH D14 HOLDDOWNS, TYP.
STH D14 HOLDDOWNS, TYP.
15'-
0"14
'-6
1/2"
12'-
0"32
'-0"
10'-
0"
5' - 9"
6'-3
"
UFER GROUND
12" dia. CONC. PIER w/ (2)#4 VERT. on 2'-0"x2'-0"x8"FOOTING w/ (3) #4 EA.WAY- TYP
SIMPSON CB66TYP. @ ALLPOSTS
3' - 9"
4' - 0"
8' - 0"
2' - 0"
FRONT SETBACK
25' - 0" 1' - 6"
FRONT SETBACK
25' - 0" 9' - 6"
28'-
6"
SID
ESE
TBA
CK
8'-0
"
SID
ESE
TBA
CK
8'-0
"18
'-6"
DRAWING NUMBER:
PHASE:
DATE:
DRAWING TITLE:
PROJECT NUMBER:
DRAWN BY / CHECKED BY:
REVISIONS:
0"1"
2"11/1
2/2
015
9:3
9:3
4A
M
1710 POWERS BLVDBLOCK 4, LOT 2
RYEN GLENNBELGRADE MT
A2.3
FOUNDATION
15.066
BEN NISTLER406-570-7345PLAN NAME:MOONLIGHT
NOVEMBER 12, 2015
EML STH
CONSTRUCTION
1/4" = 1'-0"1
0.2 FOUNDATION
NO. DESCRIPTION DATE
MAIN LEVEL100' - 0"
T.O. WALL108' - 1 1/8"
SEE 1/A3.1 FOR TYPICAL NOTES
6"
12" 6"
12"6"
12"
SEE 1/A3.1 FOR TYPICAL NOTES
6"
12"
6"
12"
MAIN LEVEL100' - 0"
T.O. WALL108' - 1 1/8"
T.O. FOOTING96' - 0"
6"
12"
6"
12"
6"
12"
1"x10" SKIRT BOARD - PAINTED
INSULATED GARAGE DOORS - TYP
VINYL WINDOWS - TYP
3.5" MIRA-TEC CORNER TRIM
30 YR ASPHALT SHINGLES
CONT. RIDGE VENT - TYP
PAINTED FIBER CEMENT LAP SIDING w/8" EXPOSURE - TYP
1"x10" BELLY BAND - PAINTED
20'-
13/
4"
PAINTED FIBER CEMENTBOARD & BATT - TYP
STONE SIDING - TYP
8"x8" POST
MAIN LEVEL100' - 0"
T.O. WALL108' - 1 1/8"
SEE 1/A3.1 FOR TYPICAL NOTES
4"
12"6"
12"
6"
12"
NOTCH BLOCKING or PROVIDEHOLES FOR ATTIC VENTILATION
• ASPHALT SHINGLES over• SYNTHETIC ROOFING UNDERLAYMENT over• 5/8" OSB over• ENGINEERED WOOD TRUSSES w/ 12" ENERGY HEEL @ 24" o.c. w/ R-49
INSULATION• PROVIDE ICE & WATER SHIELD 2 FEET FROM THE INSIDE OF THE EXTERIOR
WALL AT ALL EAVES & 18" EACH SIDE OF EACH VALLEY
1X8 FASCIA W/ 1X4SHADOW BOARD, PAINTED
VINYL WINDOW- TYP. SEE PLANS &ELEVATIONS FOR TYPE & SIZE
1/2" GYP BD overVAPOR BARRIER
5/8" GYP BD overVAPOR BARRIER
PAINTED COMPOSITE TRIM- TYP
1/2" dia. ANCHOR BOLT w/ 3x3x1/4PLATE WASHER @ 48" o.c.- TYP (BOLTSTO BE LOCATED NOT MORE THAN 12"OR LESS THAN 7 BOLT DIAMETERS FROMPLATE SECTIONS)- EMBED 7" MIN
BITUMINOUS DAMPPROOFING TOGRADE
16"x8" CONC. FOOTING w/ (2) #4 CONT.-TYP, VERIFY WITH GEOTECHNICAL REPORT
R-19 MIN OR R-15 CONT. INSULATION w/CONT. VAPOR BARRIER
6" CONC. WALL w/ #4 HORIZ. &VERT. @ 18" o.c.- TYP
9'-1
1/8"
SEISMIC CLIP (SIMPSON H1,H2.5A, or SIM) AT EA TRUSS-TYP
TYPI
CA
LH
EAD
HEI
GH
T(C
ON
FIRM
CLE
AR
OPE
NIN
GO
FEG
RESS
WIN
DO
WS
44"A
FFM
AX.
)
7'-4
"
(2) 2X10- TYP- U.N.O.
FASTEN SHEATHING TO SILLPLATE w/ 10d's @ 6" o.c.- TYP
6"M
IN3'
-6"
SIDING (SEE ELEVATIONS) on AIR INFILTRATION BARRIER on 1/2" OSB SHEATHING (SEE SHEAR WALL SCHEDULE) on 2x6 WOOD STUDS @ 16" o.c. w/ R-21 INSULATION3/4" PLYWOOD SUBFLOOR GLUED &SCREWED TO 11-7/8" I-JOISTS @ 19.2" o.c.-TYPSPRAY FOAM INSULATION AT RIMJOISTPAINTED COMPOSITE TRIMWHERE SHOWN ONELEVATIONS2X6 P.T. SILL PLATE W/ SILL SEAL
2X BLOCKING EA. TRUSS BAY
BAFFLE TO MAINTAIN 1" MIN. CLEARVENT @ UNDERSIDE OF SHEATHING
SPRAY FOAM URETHANE ATEAVES
PRE-FINISHED VENTEDMETAL SOFFIT
PRE-FINISHEDMETAL DRIP
COMPACTED STRUCTURAL FILL UNDERFOOTINGS PER GEOTECHNICALRECOMMENDATIONS & REQUIREMENTS
VAPOR BARRIER, OVERLAP JOINTS6" MIN. & SEAL, EXTEND UP WALL 6"AND ATTACH TO WALL
2X SUBFASCIA
44"M
AX.
@EG
RESS
WIN
DO
WS
DRAWING NUMBER:
PHASE:
DATE:
DRAWING TITLE:
PROJECT NUMBER:
DRAWN BY / CHECKED BY:
REVISIONS:
0"1"
2"11/1
2/2
015
9:3
9:3
9A
M
1710 POWERS BLVDBLOCK 4, LOT 2
RYEN GLENNBELGRADE MT
A3.1
ELEVATIONS
15.066
BEN NISTLER406-570-7345PLAN NAME:MOONLIGHT
NOVEMBER 12, 2015
EML STH
CONSTRUCTION
1/8" = 1'-0"2
WEST
1/8" = 1'-0"3
SOUTH
1/4" = 1'-0"1
EAST
1/8" = 1'-0"4
NORTH1/2" = 1'-0"
5WALL SECTION - 1-STORY
NO. DESCRIPTION DATE