c:usersjeffdocumentshawthorne elementary - … · 2019. 1. 28. · ansi/tia -526 -14 -c,...
TRANSCRIPT
PRINCIPAL
407
LOUNGE
412
COUNSELOR
411
NURSE
409
MAIL / WORK
408
RECEPTION
406
ENTRANCE
404
1ST GRADE
403
K2
EXTENDED
402
MUSIC /
ORCH
204
3RD GRADE
423
MUSIC /
ORCH
211
SERVING
200
MULTIPURPOSE
414
I.T.
416
SPECIAL ED
122
2ND GRADE
112
BREAKOUT
219A
BREAKOUT
231
2ND GRADE
110
2ND GRADE
111
ELEVATOR
417-1
KITCHEN
PREP
203
KINDERGARTEN
118
KINDERGARTEN
120
KINDERGARTEN
121
1ST GRADE
116
1ST GRADE
115
1ST GRADE
108
2ND GRADE
109
3/5
EXTENDED
221
5TH GRADE
234
3RD GRADE
232
3RD GRADE
219
CO
RR
IDO
R 5
15
CO
RR
IDO
R 1
11
CORRIDOR 3
13
TITLE 1
233
JANITOR
205
HALL
12
HALL
18
CLOSET
230STAIR 1
20
CHASE/DATA
205A
STORAGE
218
BR
EA
KO
UT
426
BREAKOUT
425
OPEN
OFFICE
410
ART/KILN
415
CONFERENCE
ROOM
413
LIBRARY
427
CSCT
422
SENSORY
402B
OT
402C
PT
221.1
CORRIDOR 4
14
BOILER
214
GYM
223
3/5 COATS
221D3/5
BREAKOUT
221A
3/5
STORAGE
221C
TECHNOLOGY
114
FRC
424
LIBRARY
113
FLAGSHIP
424A
PRINTING
406B
BICYCLE
STORAGE
228
24
23
22
21
20
19
66
5
4
3
13 15 16 17 18
T3-61
T3-41
T3-51
T3-31
RR J
402A
PRACTICE 2
211APRACTICE 1
211B
JANITOR
437
T7-11
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:1
0 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-1
01 22 19
TELECOMM
PLAN - FIRST
FLOOR -
OVERALL
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/16" = 1'-0"1
TELECOMM PLAN - FIRST FLOOR -OVERALL
1979
2008
1951
2018
20182018
2018
N
CORRIDOR 6
16
4TH GRADE
430
BREAKOUT
306
JANITOR
432
BOYS
433
GIRLS
434
5TH GRADE
302
5TH GRADE
309
4TH GRADE
307
4TH GRADE
304
HVAC 1972
183
TITLE 1
308
BREAKOUT
304A
BREAKOUT
302A
ELEV HALL
431
ELEVATOR
417-2
SPEECH
435
CORRIDOR 7
17
24
23
22
21
20
19
6
5
4
3
13 15 16 17 18
T3-71
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:1
4 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-2
01 22 19
TELECOMM
PLAN -
SECOND
FLOOR -
OVERALL
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/16" = 1'-0"1
TELECOMM PLAN - SECOND FLOOR -OVERALL
1979 1951
N
24
23
22
21
20
19
6
5
13 18
2
POS
2
FOR ELEVATOR CONTROL PANEL,COORDINATE LOCATION w/ ELEVATOR CONTRACTOR. TERMINATE CABLE IN DEMARC IN CHASE/DATA 205A.
MUSIC /
ORCH
204
MUSIC /
ORCH
211
SERVING
200
MULTIPURPOSE
414
GIRLS
210
BOYS
208
I.T.
416
ELEVATOR
417-1
HALL
436
GIRLS
206
BOYS
207
KITCHEN
PREP
203
CORRIDOR 3
13
JANITOR
205
HALL
12
HALL
18
CHASE/DATA
205A
ART/KILN
415
GYM
STORAGE
215
HALL
216
PE OFFICE
217A
CSCT
217B
CSCT
217C
BOILER
214
HALL
217
GYM
223
2
2
2
1
1
2
COORDINATE LOCATION w/ MECHANICAL
4
21
(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3, BY CABLING CONTRACTOR.
9
(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211.LOCATED @ ±9'-0" A.F.F. , BY CABLING CONTRACTOR.
7
(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.
LOCATED @ ±9'-8" A.F.F.
CA
M
120"
AF
F
LB
1
42" AFF
CAM
120" AFF
CAM
120" AFF
(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACES IN IT 416. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.
6
6
6
2
48" AFF
2
4
4
1
2
2
4
4
2222
2
2
4
4
4 4 4 4
PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE
PROVIDE AND INSTALL OBERON 1015-C WIRELESS AP ENCLOSURE
1" EMT CONDUIT SLEEVE STUBBED 3" INTO CEILING SPACE ABOVE HALL 12 AND STUBBED 3" INTO HVAC 183A.
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
X
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.
4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
5. NOT USED
6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
X
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:2
5 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-3
01 22 19
TELECOMM
PLAN -
KITCHEN/MUSIC/
CORE
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/8" = 1'-0"1
TELECOMM PLAN - ENLARGED -MUSIC/DINING
1951
2018
N
6
2
222
2
2AC2AC
2
2
2
2
2
4
4
4
4
2
4
4
2
AC
2
AC
2
4
(E)
2
(E)
2(E)
(E)
2
2(E)
2(E)
2
(E)
(E)
(4)-2" EMT CONDUIT SLEEVES BETWEEN CEILING SPACE ABOVE CORRIDOR 11 AND CEILING SPACE ABOVE HALL 12, BY CABLING CONTRACTOR.
ENTRANCE
404
1ST GRADE
403
K2
EXTENDED
402
SPECIAL ED
122
2ND GRADE
110
2ND GRADE
111
1ST GRADE
116
1ST GRADE
115
1ST GRADE
108
2ND GRADE
109
CORRIDOR 5
15
CORRIDOR 1
11
HALL
12
WOMENS
202
BREAKOUT
426
BREAKOUT
425
LIBRARY
427
SENSORY
402B
OT
402C
TECHNOLOGY
114
FRC
424
LIBRARY
113
FLAGSHIP
424A
22
(E)
2
(E)
2
2
(E)
4
4
4
4
1
1
1
11
1
1
1
1
44
4
4
4
4
4
4
4
4
4
4
2
4
2 1
2 1
2 1
2(E)
2(E)
(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.
9
(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN 2ND GRADE 111 AND ACCESSIBLE CEILING SPACE IN CORRIDOR 5, BY CABLING CONTRACTOR.
77
7
7
(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN CORRIDOR 5 AND ACCESSIBLE CEILING SPACE IN FIRST GRADE 115, BY CABLING CONTRACTOR.
(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN FIRST GRADE 116 AND ACCESSIBLE CEILING SPACE IN FIRST GRADE 115, BY CABLING CONTRACTOR.
9
9
(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN 2ND GRADE 111 AND CEILING SPACE IN CORRIDOR 5, BY CABLING CONTRACTOR.
LB
LB
LB
4
1
1
CONDUIT FED THROUGH NEW WALL FRAMING INTO ACCESSIBLE CEILING SPACE IN SPECIAL ED 122.
JANITOR
205
RR J
ENTRANCE
CONDUIT FED THROUGH NEW WALL FRAMING INTO ACCESSIBLE CEILING SPACE IN SECOND GRADE 112.
2ND GRADE
112
CAM
6
2AC
4
2AC
4
10
10
10
120" AFF
(E)
X
X
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.
4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
5. NOT USED
6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
10. IN AREAS INDICATED, RELOCATE PATCH PANEL TERMINATIONS IN EXISTING DATA 205A TO IT 416. RETERMINATE ONTO NEW PATCH PANELS.
X
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:3
2 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-4
01 22 19
TELECOMM
PLAN -
NORTHWEST
AREA/LIBRARY
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/8" = 1'-0"1
TELECOMM PLAN - ENLARGED -NORTHWEST
1979
2018
N
2
2
AC
2
AC
2
AC
2
AC4AC6AC2
2(E)
2
(E)
(E)
2
4
2
(E)
PRINCIPAL
407
LOUNGE
412
COUNSELOR
411
NURSE
409
RR M
406A
MAIL / WORK
408
RECEPTION
406
ENTRANCE
404
KINDERGARTEN
118KINDERGARTEN
119
KINDERGARTEN
120
KINDERGARTEN
121
OPEN
OFFICE
410
CONFERENCE
ROOM
413
PRINTING
406B
2(E)LB
2
2
2
2(E)
2
2
(E)
AC
2
2(E)
2
(E)
2
4
4
4
4
4 4
4
4
2
9
(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN CORRIDOR 1 AND ACCESSIBLE CEILING SPACE IN KINDERGARTEN 121, BY CABLING CONTRACTOR.
EXISTING (1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN KINDERGARTEN 118 AND ACCESSIBLE CEILING SPACE IN PRINTING 406B
7
7
8
7
7
77
CAM
CAM120" AFF
2(E)FOR FIRE ALARM CONTROL PANEL.COORDINATE LOCATION w/ ELECTRICAL AND FIRE ALARM CONTRACTOR.
(E)
120" AFF
(E)
10
10
10
10
10
10
10
10
10
(E)
(E)
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
X
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.
4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
5. NOT USED
6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
10. IN AREAS INDICATED, RELOCATE PATCH PANEL TERMINATIONS IN EXISTING DATA 205A TO IT 416. RETERMINATE ONTO NEW PATCH PANELS.
X
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:3
3 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-5
01 22 19
TELECOMM
PLAN - ADMIN
AREA
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/8" = 1'-0"1
TELECOMM PLAN - ENLARGEDADMIN/KINDERGARTEN
1979
2018
N
5
4
3
13 15 16 17 18
2
2
(1)-4" EMT CONDUIT BETWEEN FIRST FLOOR AND SECOND FLOOR, BY CABLING CONTRACTOR.
2
2
(N) 2"x6" CABLE TRAY, BY CABLING CONTRACTOR.
2
2
2
2
2
2
3
2
2
1
1
2
2
3RD GRADE
423
BREAKOUT
219A
BREAKOUT
231
3/5
EXTENDED
221
5TH GRADE
234
3RD GRADE
232
3RD GRADE
219
CORRIDOR 3
13
TITLE 1
233
CLOSET
230STAIR 1
20
STORAGE
218
CSCT
422
PT
221.1
CORRIDOR 4
14
3/5 COATS
221D
3/5
BREAKOUT
221A
3/5
STORAGE
221C
RR G
221B
4
1
1
11
1
1
4
4
4
4
4
(1)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3, BY CABLING CONTRACTOR.
7
7
7
77
9
7 7
LB
4
CAM
MOUNT CAMERA TO BOTTOM OF CONCRETE CANOPY
CA
M
66
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
X
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. FLOOR BOX w/ 1" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.
4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
5. NOT USED
6. ACCESS CONTROL DOOR(S). CABLING SUPPLIED BY OTHERS. CABLING CONTRACTOR SHALL PROVIDE CABLE INSTALLATION ONLY. COORDINATE LOCATION w/ ELECTRICAL AND SECURITY CONTRACTOR.
7. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
8. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
9. INDICATES A 4" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
X
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:3
9 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-6
01 22 19
TELECOMM
PLAN -
NORTHEAST
AREA
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/8" = 1'-0"1
TELECOMM PLAN - ENLARGED -NORTHEAST
1951
2018
N
20
19
6
55
4
3
13 15 16 17 18
(1)-4" EMT CONDUIT BETWEEN FIRST FLOOR AND SECOND FLOOR, BY CABLING CONTRACTOR.
22
2 2
2
2
2
2
2
3
CORRIDOR 6
16
4TH GRADE
430
BREAKOUT
306
JANITOR
432
5TH GRADE
302
5TH GRADE
309
4TH GRADE
307
4TH GRADE
304
HVAC 1972
183
TITLE 1
308
STAIR 2
21
BREAKOUT
304A
BREAKOUT
302A
ELEV HALL
431
ELEVATOR
417-2
SPEECH
435
CORRIDOR 7
17
2
2
1
1
1" EMT CONDUIT SLEEVE STUBBED 3" INTO CEILING SPACE ABOVE HALL 12 AND STUBBED 3" INTO HVAC 183A.
11
11
1
1
2
2
2
2
2
COORDINATE LOCATION w/ MECHANICAL
6
5
5
5
5
LB
4
22
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
X
X
X
INDICATES WALL MOUNTED WORK AREA OUTLET.
INDICATES FLOOR MOUNTED WORK AREA OUTLET, BY ELECTRICAL.
INDICATES CEILING MOUNTED WORK AREA OUTLET WITH DUPLEX CATEGORY 6 OUTLET. OUTLETS IN T-BAR CEILING SHALL TERMINATE IN BISCUIT BLOCK ABOVE CEILING. LABEL T-BAR AND BISCUIT. OUTLETS LOCATED IN GYP. BOARD OR OPEN TO STRUCTURE SHALL HAVE CONDUIT RUN TO NEAREST ACCESSIBLE T-BAR CEILING SPACE.
X = NUMBER OF CATEGORY 6 JACKS IN OUTLETS
LEGEND:
LBLOCKDOWN BUTTON. PROVIDE A 2 1/8" DEEP 4" SQUARE BOX WITH A SINGLE GANG MUD RING AND 3/4" CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL. COORDINATE LOCATION w/ DISTRICT SECURITY CONTRACTOR.
INDICATES FIRE RATED STI READY CONDUIT SLEEVE OR EMT CONDUIT. SEE PLANS FOR ADD'L INFO.
CAMSIMPLEX CATEGORY 6 OUTLET FOR IP CAMERA. TERMINATE INSIDE BUILDING. PROVIDE 1" SLEEVE FLUSH w/ BUILDING TO BUILDING EXTERIOR AND WEATHERPROOF SLEEVE, WHEN APPLICABLE. SLEEVE TO BE LOCATED MIN. 9'-6" A.F.F.
KEYED NOTES:
1. 2 1/8" DEEP x 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL.
2. PROVIDE WIREMOLD RACEWAY FROM NEAREST CORRIDOR TO OUTLETS.
3. 3" FIRE RATED STI READY SLEEVE LOCATED 6" ABOVE CEILING. INSTALLATION BY CABLING CONTRACTOR.
4. SURFACE RACEWAY AND OUTLET BOX BY CABLING CONTRACTOR.
5. INDICATES A 1" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
6. INDICATES A 2" FIRE RATED STI READY SLEEVE BY CABLING CONTRACTOR.
X
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:4
4 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T3-7
01 22 19
TELECOMM
PLAN -
SECOND
FLOOR -
NORTHEAST
AREA
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
1/8" = 1'-0"1
TELECOMM PLAN - SECOND FLOOR -NORTHEAST/IT CLOSET 183A
1951
2018
N
19
5
I.T.
416
CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.
CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)
(2)-4" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO CABLE TRAY IN CORRIDOR 3
(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND STUBBED TO ACCESSIBLE CEILING SPACE IN 2ND GRADE 112, BY CABLING CONTRACTOR.
(2)-4" EMT CONDUITS BETWEEN ACCESSIBLE CEILING SPACES IN IT 416. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.
(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211. LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.
CORNING 2U FIBER OPTIC PATCH PANEL,PART# CCH-02U
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
ETHERNET SWITCH, BY OWNER
CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.
APC, SMT2200RM2UNCUNITERRUPABLE POWER SUPPLY (UPS)
CHATSWORTH UNIVERSAL CABLE RUNWAY (1 1/2"H x 12"W)
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
ETHERNET SWITCH, BY OWNER
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
ETHERNET SWITCH, BY OWNER
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
CHATSWORTH, GLOBAL STANDARD PACKPART #57004-703, TYP.
(1)-2" EMT CONDUIT BETWEEN ACCESSIBLE CEILING SPACE IN IT 416 AND CEILING SPACE IN MUSIC/ORCH 211.LOCATED @ ±9'-0" A.F.F., BY CABLING CONTRACTOR.
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
COMMSCOPE CATEGOY 6 48-PORT PATCH PANEL,PART #1375015-2
ETHERNET SWITCH, BY OWNER
COMMSCOPE HORIZONTAL WIRE MANAGER,PART# 1375163-1
APC, SMT2200RM2UNCUNITERRUPABLE POWER SUPPLY (UPS)
1. THIS PROJECT IS TO CONFORM TO THE LATEST LOCALLY ADOPTED VERSION OF THE ELECTRICAL CODE AND THE LATEST REVISION OF:
ANSI/TIA-526-7-A, Measurement of Optical Power Loss of Installed Single-Mode Fiber Cable Plant, and its published addenda.ANSI/TIA-526-14-C, Measurement of Optical Power Loss of Installed Multimode Fiber Cable Plant, and its published addenda.ANSI/TIA-568.0-D, Generic Telecommunications Cabling for Customer Premises, and its published addenda. ANSI/TIA-568.1-D, Commercial Building Telecommunications Infrastructure Standard, and its published addenda.ANSI/TIA-568.2-D, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, and its published addenda. ANSI/TIA-568.3-D, Optical Fiber Cabling and Components Standard, and its published addenda.ANSI/TIA-569-D, Telecommunications Pathways and Spaces, and its published addenda ANSI/TIA 598-D Optical Fiber Cable Color CodingANSI/TIA-606-C, Administration Standard for Telecommunications Infrastructure, and its published addenda ANSI/TIA-607-C, Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises, and its published addenda. ANSI/TIA-758-B, Customer Owned Outside-Plant Telecommunications Infrastructure Standard, and its published addenda.
2. SEE SPECIFICATIONS FOR ADDITIONAL CONTRACTOR QUALIFICATIONS, PRODUCT INSTALLATION, AND QUALITY REQUIREMENTS.
3. ALL CABLES SHALL BE RUN IN CEILING SPACE SUPPORTED EVERY 48" O.C. MAX BY J-HOOKS OR BY CABLE TRAY.
4. ALL CABLING, J-HOOKS, FACE PLATES, JACKS, PATCH PANELS, RACKS, LADDER RACK, AND PATCH CABLES BY CABLING CONTRACTOR.
5. ALL OUTLET LOCATIONS SHALL HAVE A 2 1/8" DEEP BY 4" SQUARE BOX w/ A SINGLE GANG MUD RING AND A 1" EMT CONDUIT STUBBED TO NEAREST ACCESSIBLE CEILING SPACE, BY ELECTRICAL, U.N.O.
6. ALL PATHWAY AND RACEWAY INCLUDING CONDUIT SLEEVES, FLOOR BOXES, OUTLET BOXES AND CONDUIT BY ELECTRICAL, U.N.O.
7. CABLING CONTRACTOR SHALL INSTALL OWNER PROVIDED WIRELESS ACCESS POINTS.
8. CABLING CONTRACTOR SHALL DEMO ALL EXISTING CAT 5/5e CABLING, U.N.O. COORDINATE WORK w/ GENERAL CONTRACTOR.
PLAN NOTES:
DS
A,
P.C
.
CO
PY
RIG
HT
DRAWN BY:
PROJECT:
REVISIONS:
JG
2300 R
EG
EN
T S
T.,
Suite 2
07
Mis
soula
, M
T
59801
ph:
406.3
27.0
62
9fa
x:
406.5
41.9
881
access-c
onsultin
g.n
et
1/2
2/2
019 1
0:5
3:4
5 A
MY
:\2
018\ M
CP
S\H
aw
tho
rne E
lem
enta
ry\D
r aw
ings\R
evit\T
el e
com
m\H
aw
thorn
eE
lem
ent a
ry -
Tele
com
munic
ations -
Cabli n
g v
18.r
vt
T7-1
01 22 19
TELECOMM
ELEVATION -
IT 416
HA
WT
HO
RN
E S
CH
OO
L
2835 S
3rd
St
WM
issoula
, M
T 5
9804
10
0%
CO
NS
TR
UC
TIO
N D
OC
UM
EN
T S
ET
17-533
N
1/4" = 1'-0"1
TELECOMM PLAN - IT 4162
TELECOMM ELEVATION - IT 416