Page 1: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Curries Customer eBook

E119 Fire Resistive Solutions

Page 2: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

About This eBook…

This eBook is intended to provide an overview of E119 Fire Resistant Frame Solutions from CURRIES including:

E119 Frames

E119 Interior Curtain Walls

Narrow Stile Doors

To advance to the next slide, click the Green Arrow at the bottom right of the page.

To advance to a different section, click on the desired box at the bottom of the page.

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 3: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

What are “E119 Fire Resistive Frames”?

E119 refers to ASTM E119, “Standard Test Method for Fire Tests of Building Construction and Materials”. It specifically addresses “fire resistive glazing and frames”.

Fire resistive frames and interior curtain wall solutions block the passage of flames and unlike fire protective frames, also block the passage of radiant heat and thermal energy.

This type of solution is required by code when:

- Any frame has glass rated 1 hour or greater

- There is a design intent to replace a wall with glass.

- There is a 20 or 45 minute assembly that exceeds more than 25% of the area of a common wall with any room

- There is an assembly that is more than 25% of the wall length

E119 Products are tested as a wall.

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 4: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

What are ASSA ABLOY “E119 Fire Resistive Frame Solutions”

ASSA ABLOY has formed a strategic partnership with Vetrotech to produce Fire Resistive Frame Solutions

Exclusive agreement to supply Vetrotech Fire Resistive products to meet requirements of E119 and UL 263

Contraflam is a single or multi-chamber fire resistive glazing made of tempered safety glass and sealed to be completely moisture-resistant

In case of fire, the interlayers of the Contraflam glass absorb the energy from the fire, limiting the temperature rise to the non-fire side of the assembly providing protection to people and property

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 5: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Commercial Office Buildings

Hospitality

Healthcare

Entertainment

Other commercial or instructional public use facilities

Common Applications

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 6: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Fire Protection vs. Fire Resistive Know the Difference

Fire-Protection:

– Protects against smoke & flames but not radiant heat transfer

– Limited ratings beyond 45 minutes by code

– Should not exceed 25% of wall area

– Fire-protective product fire ratings

• Glass ceramic (20/45/60/90/180 Minute) (60, 90, and 180 Minute limited to 100 sqin. in doors)

• Wire glass (20, 45, 60 and 90 Minute) (60, and 90 Minute limited to 100 sq. in. in doors)

– Multiple Glass Brands may be used

– Frames have no temperature rise requirement

– Door may or may not be required to have a temperature rise rating for the first 30 minutes of the rating period

Fire-Resistive:

- Protects against smoke, flame AND radiant heat transfer.

- Allows safe evacuation without burn risk from 60-180 minutes

- Fire-resistive product fire ratings:

• 60/90/120/180

- Fire-resistant frames required

- 250o F temperature rise is required for the entire rating period for the glass AND the frame.

- Must use specific brand of glass with the frame. No substitutions

- Door may or may not be required to have a temperature rise rating for the first 30 minutes of the rating period

- Frame and glass thickness increases as hourly rating increases

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 7: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Fire Protection vs. Fire Resistive Know the Difference

Fire-Protection:

- Fire-rated glazing that can allow radiant heat transfer from one side to the opposite side (ceramic, wired glass, specialty glass)

- Glazing may or may not meet hose stream and/or temperature rise requirements

- Temperature rise requirements are only required for temperature rise door glazing (UL10b / UL10c / NFPA 252)

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 8: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Fire Protection vs. Fire Resistive Know the Difference

Fire-Resistive:

- Stops fire and radiant heat transfer

- Classified as a “fire resistive wall” rather than an “fire protective opening” and meets the same requirements as a gypsum or CMU type wall

- Both glass and framing system must block passage of heat

- May be used in multi story spans or floor to ceiling sizes, but glass may not exceed manufacturers tested size

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 9: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Fire Protection vs. Fire ResistiveKnow the Difference

Fire Protective Fire ResistiveStandards

Frames: UL 9/NFPA 257 UL 263/ASTM E119

Duration: 20 to 45 minutes 60 to 180

Glazing in excess of 100 sq.in. is not permitted

in doors within exit enclosures or passageways

Glazing in doors in excess of 100 sq.in. within

interior exit stairways, ramps and exit

passageways to be fire-resistance rated

Conditions of Acceptance (UL/NFPA)

Flaming: Limited Passage acceptableCannot be hot enough to ignite cotton waste

Hose Stream:Limited openings in the glass

(5% fall out) permitted

100% Retention required after fire

and hose straem test

Waived if glazing is used in 20 min applications

Temperature: None Temperature Rise = 250ºF + Ambient temp.

IBC 2015

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 10: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Fire Protection vs. Fire Resistive Know the Difference

Click On Video Image Below

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 11: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Why Fire Resistive Assemblies?

Code Requires Fire Resistive Assemblies when:

– Any frame has glass rated 1 hour or greater

– There is a design intent to replace a wall with glass.

– There is a 20 or 45 minute assembly that exceeds more than 25% of the area of a common wall with any room.

– There is an assembly that is more than 25% of the wall length

Remember, this product is considered as and tested as a wall

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 12: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Code Requirements

Glazing:

– 703.6 Fire-resistant-rated glazing. Fire-resistance-rated glazing, when tested in accordance with ASTM E119 or UL 263 and complying with the requirements of Section 707, shall be permitted. Fire-resistance-rated glazing shall bear a label marked in accordance with Table 716.3 issued by an agency and shall be permanently identified on the glazing.

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 13: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Code Requirements

Required Markings on Fire Rated Glass:

– Important: Note the D and H – required for fire resistive glass to be used in a door.

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 14: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Code Requirements

Fire Resistive and Fire Protective Applications:

– If a fire wall has a fire resistance rating of one hour or more only fire resistive frames and glazing can be used in sidelight or transom window frame applications

– Fire protection frames and glazing are not permitted in sidelight or transom window frame applications with a fire rating of greater than 45 minutes.

– Fire doors rated from 60 up to and including 90 minutes are permitted with fire protection glass equal to or less than 100 sq in.

– Fire doors and fire shutter assemblies are permitted

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 15: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Code Requirements

25% of the Wall Area Limitations:

– 716.6.7.2. Area limitations. The total area of the glazing in fire-protection-rated window assemblies shall not exceed 25 percent of the area of a common wall with any room.

– The phrase “common wall” will limit the size to the actual visible wall that is shared and can be seen in the two rooms. The area of the wall that continues through the interstitial space above a ceiling would not be included when determining the wall size. In addition, if the ceiling height differs on the two sides of the wall, the lowest ceiling height would be used to determine what is considered the “common wall”

25% of the Wall Length Limitations:

– 707.6 Openings. Openings in a fire barrier shall be protected in accordance with Section 716. Openings shall be limited to a maximum aggregate width of 25 percent of the length of the wall, and the maximum area of any single opening shall not exceed 156 square feet.

– Openings in enclosures for exit access stairways and ramps, interior exit stairways and ramps and exit passageways shall also comply with Sections 1019, 1023.4 and 1024.5 respectively.

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 16: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Code Requirements

25% of the Wall Length Exceptions

– Automatic sprinklers in use

– Opening is serving as a fire door in exit enclosures

– Tested to ASTM E119 or UL 263

– Permitted in Atrium separation walls

– Fire door in a fire barrier separating an enclosure for exits from an exit passageway

Adoption and Enforcement

– Some jurisdictions may not have adopted or just adopted a code edition that includes the requirement. Omaha, NE is an example.

– Many jurisdictions are just now beginning to enforce

– Some Architect’s do not have knowledge of the code requirements

Note: The requirement is not being uniformly enforced. As a result, AADG will NOT be dropping the current Fire PROTECTIVE listings and product

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 17: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Specification Sections to Watch

SECTION 084000 – Entrances, Storefronts, & Curtain Walls– 084100 Entrances and Storefronts– 084010 Metal-Framed Storefront (Includes Aluminum, Bronze, Stainless Steel, and Steel)– 084113 Aluminum Framed entrances and Storefronts – 084119 Stainless Steel Frames Entrances and Storefronts – 084123 Fire Rated Steel Storefronts– 084300 Storefronts – 084400 Curtain Wall and Glazed Assemblies – 084413 Glazed Aluminum Curtain Walls– 084419 Glazed Stainless-steel Curtain Walls

SECTION 085000 - Windows

SECTION 088000 - Glazing

Note: Have also seen as a reference on elevation Drawings. Designation varies

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 18: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Frame Technical Specifications

Contraflam fire resistive glass from Vetrotech

Tempered and Annealed Glass with Intumescent Interlayers

Non-combustible fire resistive Cementous material that drastically reduces the transfer of heat

KD or welded frame construction

16 gauge steel fire resistive frame prime painted or prefinished enamel over galvanized, chemically passivized (GVGC) steel

Fire resistive 60 min – 3 hours

Fixed jamb depths from 2-9/16” to 7-1/8” varying by fire rating

Sound rated glass up to STC 49

UL752 Level 3 bullet resistance using Contraflam Ultimax glass

Corner and angled frames available

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 19: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Frame Technical Specifications

For use with Contraflam glass and Contraflam Structure (no vertical mullions)

Corner and angled frames available

UL752 Level 3 bullet resistance available

If required, can weld multiple profiles together to create a 4” face head or a 10” sill

60 Minute

120 Minute

E119 Frame Attributes

Fire Rating Thickness Jamb Depth Face

Dimension Stop Height

Weight (lbs./lin. ft.)

60 Minute 16 ga. 2-9/16" 1-15/16" 13/16" 3.75 - 4.5

90 Minute 16 ga. 4-5/16" 1-15/16" 13/16" 6.33 - 6.63

120 Minute 16 ga. 4-5/16" 1-15/16" 13/16" 6.33 - 6.63

180 Minute 16 ga. 7-1/8" 1-15/16" 13/16" 14

Cementous Material

Angled Frame What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 20: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Interior Curtain Wall Technical Specifications

Contraflam fire resistive glass from Vetrotech

Tempered and Annealed Glass with Intumescent Interlayers

Fire resistive 60 min – 2 hours

Mullion depths of 2-15/16”, 3-9/16”, 4-5/16”, 5-1/8” or 5-7/8”

Sound rated glass up to STC 46

UL752 Level 3 bullet resistance using Contraflam Ultimax glass

Corner and angled frame available

16 gauge steel frame prime painted or prefinished enamel over galvanized, chemically passivized (GVGC) steel

Mullion face profiles of 1-3/4” or 2-3/8”

Self supporting construction

Cover profile shown with optional bevel

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 21: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Interior Curtain Wall Specifications

For use with Contraflam glass and Contraflam Structure (no vertical mullions)

For applications that require high span (greater than 12 feet tall)

Self supporting construction

Corner and angled frames available

UL752 Level 3 bullet resistance available

E119 Interior Curtain Wall Attributes

Fire Rating Thickness Mullion Depth Mullion Face Dimension

Weight (lbs./lin. ft.)

60 Minute 16 ga. 2-15/16” to 5-7/8” 1-3/4” or 2-3/8” 3.5-7

120 Minute 16 ga. 2-15/16” to 5-7/8” 1-3/4” or 2-3/8” 3.5-7

Angled Frame

Interior Curtain

Wall Cross Section

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 22: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Narrow Stile Door Technical Specifications

Contraflam fire resistive glass from Vetrotech must be used

Fire Rated 60 min – 90 min

Optional UL752 Level 3 bullet resistance rating

16 gauge steel prime painted or prefinished enamel over galvanized, chemically passivized (GVGC) steel

Hardware for narrow stile door must be used

Must be installed in E119 fire resistive frames or interior curtain wall

Singles and pairs available

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 23: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Narrow Stile Door Specifications

Contraflam glass must be used

Must be used with E119 fire resistive frames or curtain walls

UL752 Level 3 bullet resistance available

Hardware for narrow stile door must be used

Narrow Stile Door Attributes

Fire RatingSteel

Thickness Maximum Leaf

WidthMaximum Leaf

HeightWeight

(lbs./lin. ft.)

60 Minute 16 ga. 4’0” 10’0” 2

90 Minute 16 ga. 3’6” 8’0” 2

Door Vertical Cross Section

Pull Side

Push Side

Push Side

Pull Side

Door Meeting Edge

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 24: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Glass Technical Specifications

Intumescent filled and sealed glass assembly:

– Silicate-based material slows fire and heat

– Transparent until exposed to high intensity heat

– Activates in a fire, turns opaque, and expands

– Consumed by flames and heat, then the step is repeated at next pane of glass

Contraflam*

Fire Rating Thickness Max.

Exposed Width

Max. Exposed Height

Max. Exposed Area

(sq.ft. / sq.in.)

Weight (lbs./sq.ft.)

STC Rating

60 Minute 1-1/8" 94-13/16" 94-13/16" 22.8 / 3283 11.9 40

90 Minute 1-7/16" 94-13/16" 94-13/16" 30.8 / 4435 14.6 45

120 Minute 1-9/16" 94-5/8" 94-5/8" 30.8 / 4435 15.8 46

180 Minute 3-1/2" 48" 48" 16 / 2304 33 49

Contraflam Structure*

Fire Rating Thickness Max.

Exposed Width

Max. Exposed Height

Max. Exposed Area

(sq.ft. / sq.in.)

Weight (lbs./sq.ft.)

STC Rating

60 Minute 1-1/4" 138-1/2" 138-1/2" 52.6 / 7574 14 42

120 Minute 2-1/16" 126" 126" 31.5 / 4536 22.5 46

Annealed Glass

Intumescent layers

Tempered Glass

Tempered Glass

*UL752 Bullet resistant with Contraflam UltiMax glass

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 25: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Standard Features and Options

No maximum overall unit sizes since E119 Fire Resistant Frames and Interior Curtain Walls are tested and certified as wall assemblies

Protects against fire, smoke, radiant and conducted heat

Optically clear and “wire-free” aesthetics

Level 3 bullet resistant, STC ratings, frames without vertical mullions and corner and angled frames are available options

Narrow stile doors with Vetrotech Contraflam fire resistive glazing along with steel and wood doors can be used with, cylindrical and mortise locks, rim and concealed vertical rods exits including hardware mullions with butt and continuous hinges (Concealed overhead hardware cannot be applied)

Complete fire resistive wall system with Contraflam glazing from Vetrotech

Meets E119 and UL 263 and conforms to IBC fire safety requirements

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 26: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Resources - Tools

Website (Promo/Tech Sheet/FAQ)

– CURRIES

Installation instructions

– E119 Frame

– E119 Curtain Wall

• Quote Form

– CURRIES

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 27: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Resources - Who Can Help?

Quoting

– Pam Lathrop – 641-494-2967

Ordering

– Lisa Colombo - 641-494-2798

Technical questions

– Nelson Kraschel – 641-423-1334

– Branden Shank – 641-494-2926

Samples

– Lori Stewart - 641-494-2775

What are E119 Frames?

Codes and Differences

ResourcesDoor Tech

SpecificationsInt. Curtain Wall

Tech SpecificationsFrame Tech

SpecificationsGlass Tech

Specifications

Page 28: Curries Customer eBook.pdf · Internal Fire Protection vs. Fire Resistive Know the Difference Fire-Resistive:-Stops fire and radiant heat transfer-Classified as a “fire resistive

Internal

Thank youassaabloydss.com