Page 1: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Current Floor Plan

N

Page 2: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay in place however the wall removed

Page 3: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

N

Demolition Plan

1. Steel load bearing pillars at each end of current exterior wall will remain

2. Minimal demolition required Wall adjoining steel columns (1) will be demolished. All other components will simply be moved. The current timber privacy screens will be moved and replaced completely intact on the outer edge of the boundary line. Privacy screens will remain as agreed by the Body Corp to ensure that the exterior look and feel of the building is maintained.

3. The air-conditioning unit will be moved to the south side of the property to ensure access and the required ventilation to meet industry standards

LEGEND

Extent of demolition

1

2

3

Page 4: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

N

Extension Required - New Floor Plan

1. The current exterior wall adjoining the sliding doors and windows has a load bearing steal pillar on each end measuring 89 x 89 x5.0. Will retain the steel columns and remove the middle section of the wall

2. Existing sliding doors and windows will be reused. They will be moved 1.55m East (forwards) and 1.66m and south (down).

3. New all 1.66m to be built on far north end of extension (opposite side of balcony to where it currently is)

4. Air conditioning unit to be positioned in the same position but at the other end of the balcony

5. Privacy screens to remain to ensure exterior look of complex remains intact

6. New fixed window to be installed measuring 2.4h x 1.5w

1

2

3

4

5

6

Page 5: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Proposed Floor Plan (close-up view of dimensions from new exterior wall to property boundary)

Existing wire mesh balcony fence

Enough room between new exterior wall and the timber privacy screens to be able to open and close

Drawn to scale horizontally ONLY. Vertical representation is to put it in context ONLY

Room to ensure that privacy blinds do not bang against existing wire mesh fence

X2 structural steel pillars to remain and wall to be removed

Page 6: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Privacy screens will be moved further out towards the current mess fence

East side where extension is proposed – photo showing rendered wall already

built right to boundary line. When driving down Little Nicholson St from

the North the outside of the building will not look significantly different as all you

currently see is the rendered wallAir conditioner unit will be placed in the same position but will be moved to the

other end of the balcony

Page 7: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Pictures bottom left and right showing view from south side. New fixed window proposed to be installed upto where the

priviacy screens currently are to continue the look

and feel of the south side of the development. New fixed window will have the glass doors and windows already installed both in

size and colour

The current overhang from the 2nd level is the same height as the existing interior roof so minor changes required. Proposal to

remove soild brick wall and move existing glass sliding doors down

where wall currently is. 1.66m solid wall to be build where air-

conditioner unit currently is

Page 8: Current Floor Plan N. Marking C1 indicates that a load bearing steal beam is present at each end of the existing exterior wall which both need to stay

Above – sliding doors from inside. Wall measuring 1.66m in picture to left will be moved to align with closed bind in picture

above.

Above – interior view looking south east. Wall to be removed. New corner 1.55m

further forwards to be glass.