cummins brochure2010

20
7/26/2019 Cummins Brochure2010 http://slidepdf.com/reader/full/cummins-brochure2010 1/20 Cummins / Newage Range - 11 to 3300kVA

Upload: saad-zia

Post on 02-Mar-2018

264 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 1/20

Cummins / Newage Range - 11 to 3300kVA

Page 2: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 2/20

Page 3: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 3/20

Page 4: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 4/20

 Advanced Diesel Engineering Ltd. utilise technologies

which reduce the primary pollutants in the exhaust of 

a diesel generator set by approximately 80 percent.

Pollutants such as nitrogen oxides (NOx), hydrocarbons

(HC) and particulate matter (PM) from diesel engines are

precursors to smog and ozone in many populated areas

of the world. All our emissions-reduction technologiesare accomplished through in-cylinder design improvements

and precise control of the combustion process.

New technologies to reduce emissions

We are committed to meeting or exceeding clean air standards worldwide.

Low-Emissions Technologies

 Advanced Diesel Engineering lead the industry in the

development of cleaner, quieter and more efficient

diesel-powered generator sets. We are committed to

meeting or exceeding all global air quality regulatory

standards for stationary and none-road diesel-engine

generator sets through 2017 and beyond. This protects

public health and conserves vital natural resources.

Developing products for a cleaner tomorrow

Global Strength, Local Partnership

With nearly 20 years experience in power generation, we can match the right generating,transfer and control technologies with your power needs – be it continuous, prime, peaking,standby, cogeneration or a complete turnkey power plant.

What makes us different?

 ADE Ltd. Power Generation

is about more than innovative

technologies meeting your 

needs. The key is our people,

who live by a simple set of 

rules we call “The Three R’s”.

Relationships

 At ADE Ltd. you are in touch

with real people you can

trust and rely on. Wherever 

and whenever you need us,

we’ll be there for you.

Reliability

When you need real power 

you can depend on us to

deliver unrivalled reliability.

We do what we say we

will and more. We keep

our promises.

Responsiveness

We aim to provide same-day

answers, turnkey solutions,

quick delivery, split-second

start-up and alongside our

tailored service agreements,

a phone that is answered 24

hours a day, 7 days a week.

Fully integrated power systems

 Advanced Diesel Engineering Ltd, are leaders in the design

and manufacture of pre-integrated generator sets, ranging

from 8 to 3,300 kVA.

Most of our generator components – engine, alternator,transfer switches and control systems – are designed and

manufactured by Cummins CPG in the UK. Each element is

designed to work in harmony from the start.

Wherever possible our diesel generator sets meet US EPA

emissions standards and are European EU stage II compliant.

Models with optional sound-attenuated enclosures meet

or exceed EU noise regulation 2000/14/EC Step 2006.

We are ISO 9001:2008 certified.

Our renowned international manufacture and export, sales and

service facilities are well established and we guarantee a close

business relationship wherever our products are operating, providing

you with fast access to reliable service, engineering expertise and

parts support.

Page 5: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 5/20

Integrated design and manufacturing combine to give you unequalled reliability,power quality, rated performance and efficient operation.

Diesel Generator Sets

Delivering rugged, reliable mechanical and electrical

performance, our diesel generator sets are also suitedto utility peaking plants, distributed generation facilities,

peak shaving (or peak lopping) and power management

at large commercial or industrial sites.

Diesel-powered generator sets remain the best-value

choice worldwide for standby and emergency power

systems. Powered by heavy-duty Cummins engines,

our fuel-efficient generator sets are available in sizes

ranging from 8 to 3300 kVA and are known for their

responsive transient performance. Cooling systems

provide guaranteed performance in high ambient

temperatures.

High-performance, low-reactance Cummins

manufactured alternators provide good voltage

waveform and exceptional motor starting in demanding

applications such as data centres, hospitals and

industrial facilities.

Our generator sets are controlled by the world’s first

fully integrated microprocessor-based control system.

This seamlessly integrates governing, voltage

regulation, generator set control and protection

functions to provide:

• Rapid product availability

• Proven reliability and low life-cycle costs

• High efficiency and operational flexibility

• High-quality electrical performance

• Well-established service and fuel supply infrastructure

PowerCommand® InPowerTM for planned maintenance/

service capabilityPowerCommand® InPower™ for planned maintenance

and service provides both local and remote set-up and

diagnostics. The PC-based software allows a technician

to “talk to” a remote PowerCommand® system, determine

its status and make adjustments. An internet browser 

interface provides easy access to PowerCommand®

InPower’s™ useful functions.

• Strip charts – Obtain real-life recordings of changing

  conditions and performance

• Adjustments – Change system operating parameters

• Monitoring functions – Use real-time monitoring and data

  recording to simplify testing and diagnostics

• Report generation – Automatically record test data

  and formats for quick test reporting

• Fault simulations – Simulate warning & shutdown

conditions

C220 D5

QSK60

Page 6: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 6/20

C33 D5

X Series Generator Sets

The latest addition to the Cummins Power Generation range, these compact, rugged newgenerator sets provide the ideal prime or standby power solutions for small businesses,telecoms companies or agriculture.

Best in their class, X Series generator sets are lightweight,

easy to service and deliver cost-effective, reliable power 

from 8 kVA to 38 kVA @ 50 Hz and 7.5 kW to 35 kW

@ 60 Hz.

Several alternator sizes offer selectable motor starting

capacity. PowerCommand 1.1 electronic control comes

as standard to provide total system integration.

The X Series range is designed to meet ISO 8528

regulations. Optional sound-attenuated enclosures

optimise generator set cooling performance. Service points

are easily accessible and operators have plenty of room

for maintenance. In addition, X Series sets offer 500 hour 

oil change intervals using 15W40 premium Blue Ch4

grade oil.

The walls of the enclosures are insulated to provide quiet

operation and comply with the 75 dB(A) at 1 MTR at 75%

load sound levels. This ensures the lowest possible noise

levels without compromising performance.

 As with all Cummins Power Generation generator sets,

the X3.3 engine-powered X Series generator sets are

supported by a comprehensive warranty and worldwidedistributor network.

C11 D5

Please contact us for up to date information on the X series generator.

Page 7: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 7/20

Sound attenuated enclosures from Advanced Diesel Engineering meet even the most strictsound requirements and provide protection from inclement weather.

Page 8: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 8/20

The highly skilled ADE installation team can deliver, install, test and

• On site bulk fuel storage tanks

• High rise fuel pump & emergency dump systems

• Double walled pipe work

• Long run exhausts with noise damping systems

• Electrical distribution

• Building management system integration for 

Plant Room Installations

On site installation and complete plant room solutions.

warning alarms, fuel and security notifications

• Acoustic treatment for reflective surfaces

• Air flow ducts, louvres and acoustic baffles

commission plant room installations, including:

• Combined Heat and Power (CHP) systems

Internet Service Provider - Stand by generator 

Synchronised Cummins generators - Stand by system

Page 9: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 9/20

• Project management

• Site management

• M & E design and installation

• Commissioning

• Logistics

Generator Projects

 ADE’s Projects Department offersa comprehensive service to customers.

The Projects team incorporate all individual requirements

requested by the customer.

Services:

• Preventative maintenance

• Repairs and refurbishment

We offer a full range of servies from initial advice at the

feasibility and proposal stages, through to project

handover and lifetime support.

• Diesel & Gas generator installations

Data centre stand by power installation by ADE Ltd.

External radiator 

Page 10: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 10/20

50Hz  Open Generators - 10 to 3300kVA

Integrated design and manufacturing combine to give you unequalled reliability,power quality, rated performance and efficient operation.

706 4047 x 1608

825 4266 x 1879

825 4047 x 1608

900 4266 x 1879

1041 4297 x 1685

1110 4571 x 1702

1400 5105 x 2000

1675 5690 x 2033

1675 5690 x 2033

2063 6175 x 2286

2250 6175 x 2286

2500 6175 x 2494

  2750 5450 x 2251

C700 D5

C825 D5

C825 D5A

C900 D5

C1000 D5

C1100 D5

C1400 D5

C1675 D5

C1675 D5A

C2000 D5

C2250 D5

C2500 D5A

C2750 D5

C3000 D5  3000 7178 x 2254

5665

6528

6040

6680

6141

7374

10075

10626

10626

15152

15510

17217

25390

25390

Power output 50 Hz

Standby

kVA

50Hz

Model

565

660

660

720

833

888

1120

1340

1340

1650

1800

2000

2200

2400

Standby

kW

50Hz

640

750

750

820

939

1000

1250

1400

1500

1875

2000

2250

2500

2750

Prime

kVA

50Hz

512

600

600

656

751

800

1000

1120

1200

1500

1600

1800

2000

2200

Prime

kW

50Hz

4g

Emissions

50Hz

Open Set

Dimensions

(mm) L x W

 

Wet Weight

(kg)

 

Alternator 

VTA28G5

QSK23G3

VTA28G6

QSK23G3

QST30G3

QST30G4

KTA50G3

KTA50G8

KTA50GS8

QSK60G3

QSK60G4

QSK60G8

QSK78G9

QSK78G6

Engine

Type

ES17 D5  16.5 13 15 1305 x 680  554 X1.7G1

ES22 D5  22 18 20 1400 x 680  636 X2.5G1

ES28 D5  27.5 22 25 1515 x 680

12

16

20 651 X2.5G2

Power output 50 Hz

Power output 50 Hz

StandbykVA

50Hz

Model StandbykW

50Hz

PrimekVA

50Hz

PrimekW

50Hz

Open Set

Dimensions

(mm) L x W

 

Wet Weight

(kg)

 

Alternator Engine

Type

Model Tank

(L)

C11 D5

C15D5

C22D5 107

C33D5e 107

C38D5e 107

C44D5e 107

C55D5e 107

C80D5 107

C110 D5 107

C150 D5 310C150 D5e 513

C175 D5e 513

C200 D5e 513

C220 D5e 513

C250 D5 376

C275 D5 569

C300 D5 569

C330 D5 569

C350 D5

C400 D5 674

C440 D5 674

C500 D5 811

C550 D5

StandbykVA

50Hz

11

15

22

33

38

44

55

80

110

150150

175

200

220

250

275

300

330

350

400

440

500

550

StandbykW

50Hz

8.8

12

17.6

26.4

30.4

35.2

44

64

88

120120

140

160

176

200

220

240

264

280

320

352

400

440

PrimekVA

50Hz

10

13

20

30

35

40

50

72

100

136136

158

182

200

227

250

275

300

320

360

400

450

500

PrimekW

50Hz

8

10.4

16

24

28

31.68

40

58

80

109109

126

146

160

182

200

220

240

256

288

320

360

400

Emissions

50Hz

EU SII

EU SII

EU SII

EU SII

4g

EU SIIIA

EU SIIIA

EU SIIIA

EU SIIIA

4g

4g

4g

4g

EU SII

EU SII

Engine

Type

D1703-BG

D1703-BG

4B3.3G1

4BT3.3G3

4BT3.3G3

4BT3.3G3

4BT3.3G3

4BTA3.9G4

4-ISBeGI

6BTA5.9G2QSB7G5

QSB7G5

QSB7G5

QSB7G5

6CTAA8.3G2

QSL.9G5

QSL.9G5

QSL.9G5

NT855G6

NTA855G4

NTA855G7

QSX15G8

QSX15G8 811

Open Set

Dimensions

(mm) L x W

 1300 x 720

1300 x 720

1753 x 930

1753 x 930

1753 x 930

1753 x 930

1753 x 930

1950 x 1046

1977 x 1046

2404 x 11002656 x 1000

2656 x 1000

2656 x 1000

2656 x 1000

2686 x 1300

3135 x 1100

3135 x 1100

3135 x 1100

3594 x 1100

3594 x 1100

3594 x 1100

3433 x 1500

3433 x 1500

Alternator 

BC164B

BC164D

BC184E

BC184G

BC184H

UCI224D

UC224F

UC274C

UC274EUCI274E

UCI274F

UC274H

UC274H

UCD274J

UC274K

HC4D

HC4D

HC4E

HC4F

HC5C

HC5C

HC5D

Wet Weight

(kg)

 

376

385

609

645

705

776

776

1050

1200

12062027

2128

2226

2226

2000

2347

2570

2570

3386

3563

3683

4022

4220

Fuel

Consumption

Standby *

Fuel

Cons.

Prime **

FuelConsumption

Standby*

FuelCons.

Prime**

FuelConsumption

Standby*

FuelCons.

Prime**

* Litres Per Hour at 110% Load ** Litres Per Hour at 75% load

Fuel consumption shown in litres per hour * 110% Load ** 75% load

Fuel consumption shown in litres per hour * 110% Load ** 75% load

4

6

6.9

9.5

9.5

12.5

18.9

2729.8

34.7

37

39

42

45.8

50

55

61.6

72

81.4

90.2

3.6

5.4

6.2

8.4

8.4

12

17

2325.7

30

34

37

38.9

38.3

42

46

57

62

71.5

78.7

55.7 52

2.4 2.1

1.8 1.6

114

126.4

121

134

149.5

164.2

221

252.9

270

292

368

TBC

TBC

104

115.5

110

121

139

151

199

222

240

267

336

TBC

TBC

327.8 291

TBC

TBC

TBC

TBC

TBC

TBC

569

Page 11: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 11/20

Utilising the latest 3D realisation software we design and manufacture specialist

bespoke canopies and acoustic containers:

• Super silencing

• Synchronised & parallel operation with

multiple generators

• Ruggedised portable enclosures for

extreme site conditions

Bespoke Enclosures

Bespoke acoustic packaging to meet the most demanding criteria.

• Modified ISO containers

• Large scale drop-over canopies

• Low vibration enclosures for high rise installations

• Internal double skin steel fuel tanks

• External bulk fuel storage with duplex pump

options for filling local/internal fuel tank

Containerised 14MW synchronised power plant

2500kVA generator in silenced drop-over canopy

Air tight, stainless steel, fire proof pumping station enclosure

Super-Silenced 450kVA Generator enclosure, c/w

vertical acoustic, air inlet/outlet system

500kVA, zintec steel generator canopy

silenced to 60dB(A) @ 1 metre

Page 12: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 12/20

* @ 75% load unless otherwise stated 

** @ 100% load 

(x) - X Series product 

Standard Enclosed Sets 50Hz

Please refer to our website at for up to date stock levels and special offer prices on our Cummins

generator range.

By following the link on our website you can also join our mailing list to receive advance news of any offers before they

are posted online.

www.adeltd.co.uk

Standard enclosed generators up to 550kVA.

Model Dimensions

(mm) L x W x H

Wet Weight

(kg)

LWA Tank

(L)

Sound Levels

dBA @ 1m* dBA @ 7m*

Standby

kVA50Hz

 C11 D5 1454 x 769 x 1417 8811 638 72 62

C15 D5 1454 x 769 x 1417 8815 647 72 62

ES17 D5 1850 x 900 x 1375 9616.5 819 80** 63**

C22 D5 2244 x 969 x 1375 9422 933 10777 67

ES22 D5 1850 x 900 x 1375 9622 871 80** 63**

ES28 D5 1850 x 900 x 1375 9627.5 896 80** 63**

C33 D5(X) 2242 x 967 x 1513 9633 1235 75 65

C38 D5(X) 2242 x 967 x 1513 9638 1270 75 65

C38 D5e 2244 x 969 x 1575 9438 1029 10777 67

C44 D5e 2245 x 969 x 1575 9444 1029 10777 67

C55 D5e 2244 x 969 x 1575 9455 1100 10777 67

C80 D5 2280 x 1084 x 1478 9480 1690 10777 67

C110 D5 2343 x 1084 x 1478 98110 1840 10781 71

C150 D5 2920 x 1136 x 1710 96150 2102 31076 67

C150 D5e 3900 x 1100 x 2062 97150 2947 51377 69

C175 D5e 3900 x 1100 x 2062 97175 3108 51377 69

C200 D5e 3900 x 1100 x 2062 97200 3206 51377 69

C220 D5e 3900 x 1100 x 2062 97220 3206 51377 69

C250 D5 3581 x 1360 x 2170 96250 3296 37676 68

C275 D5 4254 x 1424 x 2215 97275 3924 56977 69

C300 D5 4254 x 1424 x 2215 97300 4147 56977 69

C330 D5 4254 x 1424 x 2215 97330 4147 56977 69

C350 D5 5110 x 1563 x 2447 98350 4798 76 69

C400 D5 5110 x 1563 x 2447 98400 4975 67476 69

5110 x 1563 x 2447 98C440 D5 440 5095 67476 69

C500 D5 5110 x 1563 x 2447 99500 5672 81178 71

C550 D5 550 5110 x 1563 x 2447 1005776 81179 72

C33 D5e 2244 x 969 x 1575 9433 1029 10777 67 C11 D5

C220 D5

Page 13: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 13/20

Power Generation Suppot Team

 ADE Power Generation Support Team provide specialist advice

technical support and assistance for:

• Generator Service Enquiries

• Maintenance (Planned and Unplanned)

• 24 / 7 Service and Repair - Contracted Customers

• Parts and Consumables

• Customer Service Contracts

• New Equipment Sales

Service

Our aim is to provide customers with world class service support that

is fast and responsive, flexible and convenient, and minimises equipment

downtime and costs.

We offer a range of services including

• Maintenance Scheduling - specifically designed to meet the service

• Rapid Response - 24 hour emergency call out as required

• General Servicing - all major makes and models of generator supported

Local Support on your Doorstep

With a national fleet of mobile service engineers, our highly trainedand skilled power generation service professionals have the capability,

expertise and experience to support you, wherever you may be.

Service Agreement

Each service agreement is tailor made to your specific requirements.

Once the optimised schedule of activities has been established,

our engineers will visit you via a pre-arranged appointment to undertake

the required servicing. A service agreement including regular testing,

preventative maintenance, routine servicing and optional oil sampling

will ensure that your generator continues to provide you with the vital

power you need.

For a quotation for a maintenance agreement or to arrange

contact our Power Generation Support Team who will be happy to assist.

Tel: 01977 658 100 - Email: [email protected]

Parts

For specialist advice and assistance on all products and to place your 

order for next day delivery on genuine Cummins parts and engine

consumables (including specialist coolant - with extended drain

interval, oil and filters), contct our National Parts Team.

Tel: 01977 658 100 - Email: [email protected]

Nationwide Service & Support

 ADE Ltd. provide comprehensive nationwidesupport on all generators across the UK.

needs of your business

Page 14: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 14/20

Page 15: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 15/20

• View displays of current alarms as well as alarm logs

• Set three levels of system security• Fully customise the monitoring an control system

• Monitor up to 60 devices at a site

• Remotely monitor up to 200 sites

Software and Networking

PowerCommand software and networking tools let you easily manage on-site and off-sitepower systems from one location.

Whether you’re using a desktop computer, a laptopor a mobile phone, PowerCommand iWatch™

and PowerCommand Pulse™ help you reduce power 

set-up time and maintenance.

PowerCommand Pulse for multiple power systems

PowerCommand Pulse is a full SCADA package.

Its enhanced graphical user interface quickly and easily

monitors multiple power systems.

PowerCommand Pulse features let you:

• Communicate via an ethernet connection, phone line

• Connect via an internet browser on a remote PC

• Send alarms to mobile phones, pagers

• Display voltage and frequency of each source

• Monitor one or two generator sets and up to four transfer 

• Monitor up to 30 generator sets and transfer switches

PowerCommand iWatch for reliableinternet-based monitoring

PowerCommand iWatch™ lets you monitor generator 

set and transfer switch functions via the internet.

PowerCommand iWatch™ features let you:

or available wireless configuration

or e-mail addresses

switches (PowerCommand iWatch™ 100)

(PowerCommand iWatch™ 200)

Page 16: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 16/20

Case Study

Cummins equipment utilised for dieselgenerator stand by power system at newstate-of-the-art hospital.

Equipment: Integrated 6 MVA Prime rated gen-sets providing

a standby power system with three individually controlled

Cummins Power Generation (C2250 D5) generator sets,

and a DMC 300 digital master control system.

Purpose: To deliver reliable emergency back up power for

the new state of the art Hospital in the event of a utility outage.

Covering a surface area of 95,383 square metres, the health-

care campus houses 612 beds and state-of-the-art facilities

including a high-tech diagnostics unit, an emergency care

centre, and a new mental health unit operated by the local

trust.

Continuous and reliable power is critical to the successful

treatment of patients at the new hospital, the NHS Foundation

Trust procured an emergency standby system to supply back-

up power to the hospital and health campus in the event of a

mains power outage.

Three 2000 kVA Prime rated, Model: C2250 D5

generator sets were installed which are 60 Litre V16

turbocharged QSK60-G4 engines, with fuel day tanks

fitted with a ‘double knock’ safety system to prevent

and minimise any spillages. Also supplied were air inlet

and discharge systems, exhaust gas silencers and flue

runs for the safe dispersal of emissions, fuel supply system

which included day tanks, pipe-work, leak detection

and fire wire monitoring.

Digital Master Control for simple

and autonomous operation

Each of the generator sets feature an on-board

synchroniser and controller, able to operate independently

from one another. When linked to the user-friendly touch

screen DMC 300 digital master control, that has been

configured specifically for new Edith Cavell Hospital,

allows the rapid paralleling of the mains supply and

generators, load management and the recording of data.

Uninterrupted power for critical operations

In the event of an electricity supply failure, power is

automatically restored to critical systems within 15 seconds

fulfilling C44 Hospital Specification. The digital master

control has been programmed to allow the first generator

to come on-line, and energise the whole 11 kV ring whilst

the remaining two units are synchronising with the first set.

The DMC 300 digital master control fitted with a “hot PLC

standby system” to eliminate a complete equipment failure

minimising any problems with the primary PLC.

Page 17: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 17/20

 

PowerCommand controls give you reliable, cost-effective solutions to integrateddigital paralleling.

Generator sets from Advanced Diesel Engineering are

available with industry-leading PowerCommand controls.Standard features include not only integrated digital

governing and voltage regulation, but also analogue

MainFeatures

General

 AVR

Electronic Governing

Glow plug control

Cycle cranking

Full authority engine control

Networking (LonWorks)

Networking (ModBus)

Fault history

Operator Interface

Manual start/stop

 Auto/remote start

Exercise function

 Auto LED

Not in Auto LED

Manual LED

Common Shutdown LED

Common Warning LED

Exercise LED

Fail to Start LED

Emergency stop (local and remote)

 Alphanumeric screen

Remote start input active LED

Fault reset

Measurement & Instrumentation

Oil Pressure

Oil Temperature

Water Temperature

Engine Speed

Hours Run

Number of Starts

Battery Voltage

Exhaust Temperature

Measurement & Instrumentation

3 Phase L-L & L-N Voltage & Frequency

3 Phase Current

kWhTotal kVA

Total kW & kVAr

PF

Per Phase kVAr, kW

Per Phase kVA

Shutdown Protection & Indication

Low Fuel Level

High Fuel Level

Low Oil Pressure

High Engine Coolant temperature

Failure to Crank Shutdown

Over Crank (Failure to Start)

Overspeed

PCC1301/PowerCommand 1.1

Generator controls

PowerCommand/PCC

 

- - -

- - - -

- - - -

- - - -

- - - -

- -

- - -

- -

- - -

- -

- - -

- - -

- - - -

PowerCommand 1.2

  - - -

- - -

  -

-

-

-

and digital metering, digital engine monitoring systems,

smart-starting systems, battery monitoring systems, AmpSentry™ true alternator protection and more.

MainFeatures

Shutdown Protection & Indication

Under & Over Voltage

Under & Over Frequency

Over Current

Earth Leakage

Reverse Power 

Reverse VAr 

Threshold Warning Indicators

Low Oil Pressure

Low Engine Coolant Temperature

High Engine Coolant Temperature

Low Coolant Level

Low Battery Voltage

High Battery Voltage

Batt. Alt. Charge Fault

Over Current

Over Load

Paralleling Capability

 Auto Synchronising (Isolated Bus)

kW & VAr Load Sharing Control

 Auto Synchronising (Utility Bus)

Base Load (Utility Bus)

Synchroscope

Peak Lopping

Power Transfer Function

Open Transition Transfer 

Hard Closed Transition

Soft Closed Transition (ramping)

Transfer & Base Load (Utility)

Gen/Mains Breaker Control

Gen/Mains Breaker Status Protection

Environment

Operating Temp. Range -40 C to +70 C° °

OperatingTemp.User Interface -20°C to +70°C

Humidity up to 95% (none condensing)

Codes & Standards

CE Compliant

NFPA110

UL508 Listed

UL Certified

Controller Inputs/Outputs

Relay Outputs

Configurable Input/Output

PCC3201

Digital Inputs (shutdown, warning or status)

Option Standard

PCC2100 with optional Bargraph fitted

- Not Available

Generator controls

PowerCommand/PCC

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2

2

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

4

2

N/A

-

-

-

-

-

-

-

-

-

-

-

-

-

-

4

4

PowerCommand 3.3

N/A

-

-

-

-

-

-

-

-

-

4

4

N/A

-

-

-

4

4

2

4

Page 18: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 18/20

Standard Gen-set

 Applicable for supplying power to varying electrical

load for the duration of power interruption of a reliable

utility source. Emergency Stand by Power (ESP)

is in accordance with ISO 8528. Fuel Stop power 

in accordance with ISO 3046, AS 2789, DIN 6271

and BS 5514.

Limited-Time Running Power (LTP):

 Applicable for supplying power to a constant electrical

load for limited hours. Limited Time Running Power (LTP)

is in accordance with ISO 8528.

Prime Power (PRP):

 Applicable for supplying power to varying electrical load

for unlimited hours. Prime Power (PRP) is in accordance

with ISO 8528. Ten percent overload capability is

available in accordance with ISO 3046, AS 2789,

DIN 6271 and BS 5514.

Base Load (Continuous) Power (COP)

 Applicable for supplying power continuously to a constant

electrical load for unlimited hours. Continuous Power 

(COP) in accordance with ISO 8528, ISO 3046, AS 2789,

DIN 6271 and BS 5514.

For comprehensive conditions of application including

COP and LTP, please refer to factory.

This document lists the main specifications and options

of the gen-set. For other customer specified

requirements, please contact us to discuss your

needs.

Standard O Optional x Not Available•(1) C22 D5 has only PCC 1301 control available

 2) C150 D5e has only PowerCommand 1.1 control available

Emergency Stand-by Power (ESP):

  Specifcations and OptionsC22-C55

(B3.3)C11-C15

  4 S troke water coo led D iese l eng ine Kubota Cummins  Mechanica l governing • •  Elec tronica l governing O O  Standard a ir f lter • •  Heavy Duty a ir f lter O O  Water j acket heater 220/240 v O O  Radia tor for 40°C ambient tempera ture x x  Radia tor for 50°C ambient tempera ture • •  Radia tor for 55°C ambient tempera ture x x  Antifreeze 25/75 (Ethylene glycol) • •  Antifreeze 50/50 (Ethylene glycol) O O  Deli vered w ithout coolant O O  Fan and belt guards • •  Core guards • •  Alternator single bearing T° = class H. Isol. = class H • •  Alternator heater O O  High humid ity i so la tion O O  Para lle li ng CT’s + 3 func tion governor x x  Exci te r vol tage regu la tor – PMG 3 phase sensing x x  PCC 1301 • • (1)

PCC 2100 x x  PCC 3100 x x  PCC 3201 x x  Power Comm and 1.1 x •  (1)  Power Comm and 1.2 x x  Power Comm and 3.3 x x  Alternator mounted (rear side) x x  Alternator mounted (right side from engine) x x

  Alternator mounted (left side from engine)

x x  Pedestal side mounted (le ft side f rom a lternator) x x  Ped estal end mount ed x x  Pedestal side mounted (r ight side from a lternator) • •  CE compliance x x  CSA/NRTL/C compl iance • •  3 po le Main Ci rcui t B reaker O O  4 po le Main Ci rcui t B reaker • •  Base Frame w ith AVM • •  Handl ing by 2 fork s lo ts i ntegra ted x x  4 d irect ion handing by pal le t j ack and fork slots • •  4 eyes fo r li ft ing • •  Manual handbook mul ti l anguage (Eng/Fre /Spa) • •  Manual ha ndbook, specify language O O  2 years warranty for standby app li ca tion, 1 year for Pr ime • •  5 years extension warranty fo r Standby app licat ion O O  2 years warranty – Pr ime power 6 ,000 hours O O  10 years majo r componen ts x x  Packing expor t box O O  Deli vered in Munse ll Green under p last ic shr inked • •  Oil tap • •  Oil sump pump x x  Attenuation industrial silencer delivered loose • •  Attenuation industrial silencer not delivered O O  Attenuation residential silencer delivered loose O O  Attenuation critical silencer x x  Silencer extension O O  Si lencer fex ib le O O  Stainless bel lows x x  Heat shields on open sets • •  Star ter and charge al te rnator • •  Star ting bat te ries w ith cab les and bracket • •  Star ting bat te ries and bracket no t deli vered, cables last O O  Large fuel tank integra ted in the base f rame (PVC type) x x  Large fuel tank integra ted in the base f rame (meta l t ype) x x  Large fue l tank integra ted in the base f rame (we lded) • •  Flu id catchment • •  Secondary containment x O  Fuel aut omatic make up x x  Fuel p re-f lter /water separa tor • •  500 li tres f ree-standing fuel tank de li vered loose x x  Silent Power canopy O O  Deli vered in Munse ll Green under p last ic shr inked • •  Special colour in replacement o f Munse ll Green O O  Modular st ructure in bolted sheet metal • •  Complete process with degreasing before powder co ating • •  Fit ti ng wi th seal to prevent water ingression • •  Numbers of po in t li ft 1 1  Fixed w indow for contro l panel • •  External emergency s top but ton • •  Res idential si lencer in tegrated to the canopy • •  Number o f doors w ith Sing le key latches 3 4  Power Box mode l ( see specic in form ation on page 11) x x  CSC approva l for shipment x x  Res idential si lencer in tegrated to the conta iner x x  Floor x x  Access doors x x  Weather l ouver air out le t x x  24 vol ts li gh t w ith t imer x x  Emergency l ight and secur it y fue l shut off va lve x x

  L ight ing/European standard outlets 220V x x  Fuel tank 500 lit res x x  Fuel tank none x x  Fuel tank 500 lit res, with u id ca tchment x x  Fuel tank, 2000 li tres (no t suitab le fo r c ri ti ca l s ta rt ) x x  Fuel tank double wall, 4000 litres (not suitable for critical start)   x x

    E   n   g    i   n   e

    R   a    d    i   a    t

   o   r

    A    l    t   e   r   n   a    t   o   r

    C   o

   n    t   r   o    l    P   a   n   e    l

    G   e   n   s   e    t

    O    i    l

    S    i    l   e   n   c   e   r

    B   a    t    t   e   r   y

    F   u   e    l

    S    i    l   e   n    t    E   n   c    l   o   s   u   r   e

    S    i    l   e   n    t    C   o   n    t

   a    i   n   e   r    (    P   o   w   e   r    B   o   x    )

Specifications

and Options

Page 19: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 19/20

C70-C80

(B3.9)

C100-C150

(ISBe-B5.9)

C150-C220

(QSB7)

C250

(6C) QSL

 

NT/NTA

 

QSX15

 

QSK23

 

VTA28 QST30 

K38

 

KTA50

QSK60

QSK78 

ummins ummins ummins ummins ummins ummins ummins ummins ummins ummins ummins ummins 

• x x x x x x x x x x xO • • • • • • • • • • •• • x • • • • • • •O O • O O O O O O O O OO O O O O O O O O O O Ox x x x x x x • • • • •• • • • • • • O O O O Ox x x x x x x x x x O x

• • • • • • • • • • • xO O O O O O O O O O O xO O O O O O O O O O O •• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • • • •O O O O O O O O O O O OO O O O O O O O O O O Ox x x x x x O O O O O OO O O O O O O O • • • •• • x • • x x x x x x xO O x O x • • • x x • xx x x x x x x x • • O xx x x x x x O O x x x •x x • x x x x x x x x xx x • (2) x x x x x x x x xx x O (2) x x x x x x x x xx x x x • • x • • • • x

• • x • x x x x O O x x

O O x O x x x x x x x xx x • x x x • x x x x •x x x x • • x x x x x xx x x x O O x x x x x x

• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • O O O O OO O O O O O O O O O O O

• • • • • • • • • • • •• • O • x x x x x x x xx x x x x x x x x x x x

• • • • • • • • • • • •• • • • • • • x x x x xO O O O O O O • • • • •• • • • • • • • • • • •O O O O O O O O O O O OO O O O O O O O O O O Ox x x x x x x O O O O OO O O O O O O O O O O O

• • • • • • • • • • • •

• • • • • • • • • • • •O O O O O O O O O O O O

• • • • • • • O O O O OO O O O O O O x x x x xO O O O O O O O O O O Ox x x x O O O O x x x xO O O O x x x x x x x xO O O O O O x x x x x xx x x x x x O O O O O O

• • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • O O O O OO O O O O O O x x x x x

• • x • x x x x x x x xO O x O x x x x x x x xx x • x • • • x x x x xx x • x O O O x x x x xx x O x O x x x x x x xx x O x O x x O O O O O

• • • • • • • • • • • •x x x x x x x O O O O OO O O O O O O x x x x x

• • • • • • • x x x x xO O O O O O O x x x x x

• • • • • • • x x x x x

• • • • • • • x x x x x

• • • • • • • x x x x xx x 2 2 2 2 2 x x x x x

• • • • • • • x x x x x

• • • • • • • x x x x x

• • • • • • • x x x x x4 4 4 4 4 4 4 x x x x xx x x x x x x x PB 20S PB 40S PB 40S PB40Xx x x x x x x x • • • •x x x x x x x x • • • •x x x x x x x x wood wood wood metalx x x x x x x x 2 2 2 5x x x x x x x x O O O •x x x x x x x x • • • •x x x x x x x x O O O O

x x x x x x x x O O O Ox x x x x x x x • • • •x x x x x x x x O O O Ox x x x x x x x x O O xx x x x x x x x x O O xx x x x x x x x x x x

Page 20: Cummins Brochure2010

7/26/2019 Cummins Brochure2010

http://slidepdf.com/reader/full/cummins-brochure2010 20/20