cta professional user remote touch-screen interface for

4
CRIOTHERM ZETA PLUS SRL sede legale e amministrativa di MONTEBELLUNA: Vicolo Boccacavalla, 16 - 31044 Montebelluna (TV) Tel. 0423 603451 sede di PIOVE DI SACCO: Via O. da Molin, 2 - 35028 Piove di Sacco (PD) Tel. 049 5842254 Fax 049 9708415 www.criotherm.com [email protected] NABLA PRO (cucine) incasso funzionalità eng - rev. 00 - 26/03/2019 Copyrights © 2016 3. TIME BANDS It displays the operang status according to me bands set directly by the display on the machine, and if the me bands is acve it allows to force the mode (ECONOMY, COMFORT, USER) up to the next instant of me band change. The choice of the temporary mode is made through a special screen on the touch-screen display. CTA PROFESSIONAL user remote touch-screen interface for KITCHEN application NABLA PRO KITCHENS 1. ON/OFF Allows the AHU to be turned on/off like the display on the machine. winter summer hot cold humid. dehumid. 2. OPERATING MODE It allows you to view the acve operang mode (heang/cooling) and show if a humidificaon or dehumidificaon acon is in progress. 4. SET-POINT CHANGE Allows to change the acve temperature set-point through a specific screen acvated by clicking on the displayed temperature. Similarly for the humidity set-point, if this type of regulaon is acve on the units. 5. SEASON CHANGE Allows to change the operang mode for temperature control. 1 2 3 4 5 7 6 6. FAN SPEED CHANGE Allows fan speed change. 70%

Upload: others

Post on 13-Nov-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CTA PROFESSIONAL user remote touch-screen interface for

CRIOTHERM ZETA PLUS SRLsede legale e amministrativa di MONTEBELLUNA: Vicolo Boccacavalla, 16 - 31044 Montebelluna (TV) Tel. 0423 603451sede di PIOVE DI SACCO: Via O. da Molin, 2 - 35028 Piove di Sacco (PD) Tel. 049 5842254 Fax 049 9708415www.criotherm.com [email protected]

NA

BLA

PR

O (c

ucin

e) in

cass

o fu

nzio

nalit

à en

g -

rev.

00

- 26

/03/

2019

Copyrights © 2016

3. TIME BANDSIt displays the operating status according to time bands set directly by the display on the machine, and if the time bands is active it allows to force the mode (ECONOMY, COMFORT, USER) up to the next instant of time band change. The choice of the temporary mode is made through a special screen on the touch-screen display.

CTA PROFESSIONAL user remote touch-screen interface for KITCHEN application NABLA PRO KITCHENS

1. ON/OFFAllows the AHU to be turned on/off like the display on the machine.

winter summer

hot cold

humid. dehumid.

2. OPERATING MODEIt allows you to view the active operating mode (heating/cooling) and show if a humidification or dehumidification action is in progress.

4. SET-POINT CHANGEAllows to change the active temperature set-point through a specific screen activated by clicking on the displayed temperature. Similarly for the humidity set-point, if this type of regulation is active on the units.

5. SEASON CHANGEAllows to change the operating mode for temperature control.

1

2

3

4

5 7

6

6. FAN SPEED CHANGEAllows fan speed change.70%

Page 2: CTA PROFESSIONAL user remote touch-screen interface for

CRIOTHERM ZETA PLUS SRLsede legale e amministrativa di MONTEBELLUNA: Vicolo Boccacavalla, 16 - 31044 Montebelluna (TV) Tel. 0423 603451sede di PIOVE DI SACCO: Via O. da Molin, 2 - 35028 Piove di Sacco (PD) Tel. 049 5842254 Fax 049 9708415www.criotherm.com [email protected]

NA

BLA

PR

O (c

ucin

e) in

cass

o fu

nzio

nalit

à en

g -

rev.

00

- 26

/03/

2019

Copyrights © 2016

7. VISUALIZATION OF ALARMSThe presence of active alarms is signaled by showing the red triangle with the alarm symbol in the upper right corner of the display. With a click in this area it is possible to show the description of the type of active alarm.Below are the various categories in which the alarms managed by the unit are grouped:

Probe alarm•Zone alarm•Belimo alarm•Blocking alarms•Alarms Filters•Alarms Motors 1-2-3-4•

Supply fan alarms•Ventilation alarms recovery•Antifreeze alarm•Adjustment alarm•

MAIN DISPLAY AND NAVIGATION

Main mask Temperature set-point change page (using the + and - keys on the sides of the screen)

Time band mode change page (USER, COMFORT, ECONOMY, OFF, PRE-TREATMENT)

Active alarm page (with the arrow on the right and left of the screen you can view the other active alarms)

Page 3: CTA PROFESSIONAL user remote touch-screen interface for

CRIOTHERM ZETA PLUS SRLsede legale e amministrativa di MONTEBELLUNA: Vicolo Boccacavalla, 16 - 31044 Montebelluna (TV) Tel. 0423 603451sede di PIOVE DI SACCO: Via O. da Molin, 2 - 35028 Piove di Sacco (PD) Tel. 049 5842254 Fax 049 9708415www.criotherm.com [email protected]

NA

BLA

PR

O (c

ucin

e) in

cass

o fu

nzio

nalit

à en

g -

rev.

00

- 26

/03/

2019

Copyrights © 2016

TECHNICAL DATA

Resistive color touch-screen display 3,4”Display resolution 320 x 240In-wall installationDimensions 134 x 96 x 32,55 mm

Power supply 24 Vac/VdcOperating temperature 0..+50°CDegree of frontal protection: IP65 (installed)

DIAGRAM OF ASSEMBLY HOLES

86,5 mm

119,5 mm

< 9 mm

60 mm

2xØ6 mmpanel

(flush-mounted box)

86,5 mm

32,5 mm134 mm

120 mm

96 mm

Page 4: CTA PROFESSIONAL user remote touch-screen interface for

CRIOTHERM ZETA PLUS SRLsede legale e amministrativa di MONTEBELLUNA: Vicolo Boccacavalla, 16 - 31044 Montebelluna (TV) Tel. 0423 603451sede di PIOVE DI SACCO: Via O. da Molin, 2 - 35028 Piove di Sacco (PD) Tel. 049 5842254 Fax 049 9708415www.criotherm.com [email protected]

NA

BLA

PR

O (c

ucin

e) in

cass

o fu

nzio

nalit

à en

g -

rev.

00

- 26

/03/

2019

Copyrights © 2016

EXAMPLE OF RECESSED INSTALLATION ON PANEL

EXAMPLE OF WALL MOUNTED INSTALLATION

The NABLA PRO remote display can be mounted horizontally on a vertical panel.

The NABLA PRO remote display can be mounted horizontally on a vertical surface using a flush-mounted box.