csi building safety construction services inspections...construction services & inspections 411...

10
Construction Services & Inspections 411 W 1 st St Rm 100 Duluth MN 55802 218 730 5240 [email protected] BUILDING SAFETY DULUTHmn.gov CS&I Doc 090-0518 Manufactured (HUD) Home Installation Permit & Plan Review Application Home and Site Information New Home Address of Installation In a Park Private Site Reinstall Used Home Single Section Multi-Section Home Manufacturer’s Name Size Date of Manufacture Foundation Type: Engineered Slab Frost Depth Footings Ground Set Applicant Information Applicant Name Address City State Zip Applicant is: Licensed Installer Owner of Man’s Home Park Email Daytime Phone Installer Information Same as Applicant Installer Name Address City State Zip License No. Installer is responsible for: Email Foundation Anchoring Support Daytime Phone Plumbing Mechanical Means of Egress (Landings, Steps, Guards and Handrails Required) Plans must be submitted and reviewed and a separate permit issued at the same time the installation permit is issued. Who is responsible for construction of the Means of Egress? Licensed Contractor Park Owner of home, authorized in writing by park Name Address City State Zip Attach Plans for Means of Egress Email Daytime Phone Plumbing, Electrical and Mechanical Who is responsible for the following work (Separate permits required)? Plumbing Licensed Installer Plumber Name Daytime Phone Electrical (Must be MN licensed electrical contractor) Name Daytime Phone Mechanical Owner of Home Mech Contractor Name Daytime Phone Applicant Signature Signed Date I hereby certify that the information provided in this application is true and correct. All provisions of law and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not give authority to violate or cancel the provisions of any other state or local law regulation manufactured home installations. #manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 1 of 10

Upload: others

Post on 06-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 [email protected]

BUILDING SAFETY DULUTHmn.gov CS&I

Doc 090-0518

Manufactured (HUD) Home Installation Permit & Plan Review Application Home and Site Information

New Home Address of Installation In a Park Private Site

Reinstall Used Home Single Section

Multi-Section Home Manufacturer’s Name Size Date of Manufacture

Foundation Type: Engineered Slab Frost Depth Footings Ground Set

Applicant Information

Applicant Name Address City State Zip Applicant is:

Licensed Installer Owner of Man’s Home Park Email Daytime Phone

Installer Information Same as Applicant

Installer Name Address City State Zip

License No. Installer is responsible for:

Email

Foundation

Anchoring

Support

Daytime Phone

Plumbing Mechanical

Means of Egress (Landings, Steps, Guards and Handrails Required) Plans must be submitted and reviewed and a separate permit issued at the same time the installation permit is issued. Who is responsible for construction of the Means of Egress?

Licensed Contractor Park Owner of home, authorized in writing by park

Name Address City State Zip

Attach Plans for Means of Egress Email Daytime Phone

Plumbing, Electrical and Mechanical Who is responsible for the following work (Separate permits required)? Plumbing

Licensed Installer Plumber Name Daytime Phone

Electrical (Must be MN licensed electrical contractor) Name Daytime Phone

Mechanical Owner of Home Mech Contractor

Name Daytime Phone

Applicant Signature Signed Date

I hereby certify that the information provided in this application is true and correct. All provisions of law and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not give authority to violate or cancel the provisions of any other state or local law regulation manufactured home installations.

#manufacturedhome; #installation

I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 1 of 10

Page 2: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 2 of 10

DOUBLE-WIDE SUPPORT PIER PLAN (TYPICAL)

MANUFACTURER INFORMATION

Name

Home Size

Maximum I-Beam Spacing

Door Openings

I-Beam Loading PLF

Maximum End Support (I-Beam)

Ground Moisture Control Yes No

Mate Line Loads

Grading to Slope AWAY From Home

SOIL INFORMATION

Classification No.

Soil Bearing Capacity

FOOTING INFORMATION

I-Beam x x

Mate Line x x

’ “

’ ” - MAXIMUM END PIER SPACING ALLOWED REQUIRED DIMENSION

ORIENTATION MATE LINE PIER LOCATIONS

REQUIRED DIMENSIONS

” ’ -

’ ” - MAXIMUM END PIER SPACING ALLOWED REQUIRED DIMENSION

I-BEAM PIER LOCATIONS REQUIRED DIMENSIONS

” ’ -

PERIMETER PIER SUPPORT @ OPENINGS REQUIRED DIMENSIONS

I-B

EA

M S

PA

CIN

G

MA

X G

AP

ALLO

WE

D—

FL

OO

R

MA

X G

AP

ALLO

WE

D—

CE

ILIN

G

MA

X. G

AP

ALLO

WE

D--

RID

GE

Page 3: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 3 of 10

LO

NG

ITU

DIN

AL

AN

CH

OR

LO

CA

TIO

N

DOUBLE-WIDE ANCHORING PLAN (TYPICAL)

REQUIRED DIMENSION

MANUFACTURER INFORMATION

Name

Home Size

Maximum I-Beam Spacing

Maximum Anchor Spacing

SOIL INFORMATION

Classification No.

Soil Bearing Capacity

ANCHORING INFORMATION

Ext. Wall Height

Roof Pitch

Height From Ground to

Frame Connection

ANCHORING INFORMATION Cont.

Anchor Manufacturer

Lateral Anchors Req’d YES or NO

Anchor P.N.

Connector P.N.

Longitudinal Anchors Req’d YES or NO

Anchor P.N.

Connector P.N.

No. Per End

Mate Line

Lateral Anchors Req’d YES or NO

Anchor P.N.

Connector P.N.

* P.N. = Part or Product Number

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

’ - ”

’ - ”

’ ” - MAXIMUM END ANCHOR SPACING ALLOWED

MAXIMUM INTERMEDIATE ANCHOR SPACING ALLOWED REQUIRED DIMENSION

’ ” - MAXIMUM END ANCHOR SPACING ALLOWED REQUIRED DIMENSION

ORIENTATION

MATE LINE ANCHOR LOCATIONS REQUIRED DIMENSIONS

’ - ” MAXIMUM END ANCHOR SPACING ALLOWED REQUIRED DIMENSIONS

I-B

EA

M S

PA

CIN

G

LO

NG

ITU

DIN

AL

AN

CH

OR

LO

CA

TIO

N

Page 4: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 4 of 10

SINGLE-WIDE SUPPORT PIER PLAN (TYPICAL)

ORIENTATION

MANUFACTURER INFORMATION

Name

Home Size

Maximum I-Beam Spacing

Door Openings

I-Beam Loading PLF

Maximum End Support (I-Beam)

Ground Moisture Control Yes No

Grading to Slope AWAY From Home

SOIL INFORMATION

Classification No.

Soil Bearing Capacity

FOOTING INFORMATION

I-Beam x x

’ “

’ ” - MAXIMUM END PIER SPACING ALLOWED REQUIRED DIMENSION

I-BEAM PIER LOCATIONS REQUIRED DIMENSIONS

” ’ -

PERIMETER PIER SUPPORT @ OPENINGS REQUIRED DIMENSIONS

I-B

EA

M S

PA

CIN

G

Page 5: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 5 of 10

LO

NG

ITU

DIN

AL

AN

CH

OR

LO

CA

TIO

N

SINGLE-WIDE ANCHORING PLAN (TYPICAL)

REQUIRED DIMENSION

MANUFACTURER INFORMATION

Name

Home Size

Maximum I-Beam Spacing

Maximum Anchor Spacing

SOIL INFORMATION

Classification No.

Soil Bearing Capacity

ANCHORING INFORMATION

Ext. Wall Height

Roof Pitch

Height From Ground to

Frame Connection

ANCHORING INFORMATION Cont.

Anchor Manufacturer

Lateral Anchors Req’d YES or NO

Anchor P.N.

Connector P.N.

Longitudinal Anchors Req’d YES or NO

Anchor P.N.

Connector P.N.

No. Per End

* P.N. = Part or Product Number

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

’ - ”

’ ” - MAXIMUM END ANCHOR SPACING ALLOWED

MAXIMUM INTERMEDIATE ANCHOR SPACING ALLOWED REQUIRED DIMENSION

ORIENTATION

’ - ” MAXIMUM END ANCHOR SPACING ALLOWED REQUIRED DIMENSIONS

I-B

EA

M S

PA

CIN

G

LO

NG

ITU

DIN

AL

AN

CH

OR

LO

CA

TIO

N

Page 6: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 6 of 10

of TOP SOIL REMOVED

FROST DEPTH PIER SECTION VIEW FORM/DIAGRAM

CARDBOARD FORMING TUBE

EXISTING GRADE

DEPTH

”BELOW”

” GRADE ”

ALTERNATE

“BELLED”

FOOTING

” ”

SOIL CLASSIFICATION

SOIL BEARING CAPACITY PSF

FOOTING AREA SQ. IN.

SOILS TOTAL LOAD CAPACITY

PSI CONCRETE

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

Page 7: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 7 of 10

FRAME PIER SECTION VIEW FORM/DIAGRAM

TOTAL HEIGHT

FRAME HEIGHT

____”

____”

PIER HEIGHT

HARDWOOD SHIM

CAP MATERIAL

BLOCK TYPE

FOUNDATION TYPE

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

Page 8: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 8 of 10

Ref. MS 327.32 Subd 1e and 1f

Notice of Reinstalling of a Single-Section Used Manufactured Home Above the Frost-Line

WHICH MAY VOID WARRANTY

It is recommended that the single-section used manufactured home being reinstalled follow the instructions in the manufacturer's installation manual. By signing this notice, the owner(s) or purchaser(s) are acknowledging they have elected to use footings placed above the local frost line* in accordance with the Minnesota State Building Code. The seller or installer has explained the differences between the manufacturer's installation instructions and the installation system selected by the owner(s) or purchaser(s) with respect to possible effects of frost on the manufactured home.

The owner(s) or purchaser(s) acknowledge by signing this notice that there is no manufacturer's original warranty remaining on the home and recognize that any other extended or ancillary warranty could be adversely affected if any applicable warranty stipulates that the home be installed in accordance with the manufacturer's installation manual to remain effective.

After the reinstallation of the manufactured home, it is highly recommended that the owner(s) or purchaser(s) have a licensed manufactured home installer recheck the home's installation for any re-leveling needs or anchoring system adjustments each freeze-thaw cycle.

The owner(s) or purchaser(s) of the used manufactured home described below that is being reinstalled acknowledge they have read this notice and have been advised to contact the manufacturer of the home and/or the Department of Labor and Industry if they desire additional information before signing this notice.

It is the intent of this notice to inform the owner(s) or purchaser(s) that the owner(s) or purchaser(s) elected not to use a frost-protected foundation system for the reinstallation of the manufactured home as originally required by the home's installation manual.

*In Duluth, required footing depth for frost protection is 60 inches (5 feet)

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

Page 9: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 9 of 10

Plain language notice

I understand that because this home will be installed with footings placed above the local frost line, this home may be subject to adverse effects from frost heave that may damage this home.

Owner(s) or Purchaser(s) initials:

I understand that the installation of this home with footings placed above the local frost line could affect my ability to obtain a mortgage or mortgage insurance on this home.

Owner(s) or Purchaser(s) initials:

I understand that the installation of this home with footings placed above the local frost line could void my warranty on the home if any warranty is still in place on this home.

Owner(s) or Purchaser(s) initials:

Printed name(s) of Owner(s) or Purchaser(s)

Signatures of Owner(s) or Purchaser(s) Date

Street address and City of reinstallation of manufactured home

Name of Home Manufacturer

Model number Year of Manufacture

Serial Number

Name of licensed installer or homeowner responsible for installation

Installer license number

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518

Page 10: CSI BUILDING SAFETY Construction Services Inspections...Construction Services & Inspections 411 W 1st St Rm 100 Duluth MN 55802 218 730 5240 permittingservices@duluthmn.gov BUILDING

#manufacturedhome; #installation I:\DEVELOPMENT\ConstSvcs\FORMS and INFO OUT\Current Handouts\Form - Manufactured (HUD) Home Installation Permit & Plan Review Application 90.pdf Page 10 of 10

Manufactured Home Support Pier Requirements from Minnesota State Building Code Section 1350.3300

1350.3300 PIER SPECIFICATIONS.

Subpart 1. Piers less than 40 inches tall.

Copyright ©2010 by the Revisor of Statutes, State of Minnesota. All Rights Reserved.

Manufactured (HUD) Home Installation Permit & Plan Review Application

Doc 090-0518