Cse & WTe 350FlaT bed uniT1 or 2 roW oF Fans

air cooLed condensed Unit | drY cooLer Unit

Page 2: Cse & WTe 350 - Aermec

AIR CONDENSER AND lIquID COOlERSwITH AxIAl fANS• Configuration: 1 exchangers• 1 or 2 circuits• 1 or 2 fans row• Wide range of capacity• 60 models available as condenser• 60 models available as dry coolers• Fan diameter: 350 mm• Number of fans: from 1 to 6• Vertical or horizontal installation

CONSTRuCTION CHARACTERISTICSThey are realized with technologies and material which guarantee strength against atmospheric agents.High efficiency finned block heat exchangers realized with copper tubes and alluminium fins. New generation axial fans with 350 mm diameter both available version AC and EC chosen for minimizing the energy consumption. Standard unit are supplied with cabled fans and electrical box with clamps.

AVAIlAblE fANSBM°: 4-poles 1-phaseSM°: 6-poles 1-phaseCMB: fan motor 1-phase EC high power CMS: fan motor 1-phase EC low noise level

ACCESSORIESCSE and WTE unit could be equipped with main switch, switchboard, cut phase fan speed regulator or EC controller and temperature sensor, pressure sensor or 0-10V signal.Anti-vibration device are also available for reducing machine’s vibrations.

Models

Model

Main switch

Switchboard

Phase cut regulatori

Controller ec

Probe Piedini

Anti-vibration

device

CSE-WTE BM° p p p p p

CSE-WTE SM° p p p p p

CSE-WTE CMB p p p p p p

CSE-WTE CMS p p p p p p

Cse condenser and WTe dry cooler’s serie meet equipment’s power requirements.They are available from 1 up to 6 fans both version aC and eC.

Page 3: Cse & WTe 350 - Aermec

CApACITYIn air condenser unit power range with refrigerant R134a is from 1.1 up to 17.5 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)

In air condenseer unit power range with refrigerant R410A is from 1.4 up to 20.4 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)

In dry cooler unit power range with ethylene glycol 30% is from 1.1 up to 16.1 tons (ambient air temperature +77°F, inlet liquid temperature +104°F outlet liquid temperature +95°F according to EN 1048)

TeChniCal draWinG

Quota a

- CSE/WTE° 301(3/4)

- CSE/WTE° 302(3/4)

- CSE/WTE° 303(3/4)

- CSE/WTE° 304(3/4)

- CSE/WTE° 306(3/4)

Quota a

12.1

3 in

22

mm

22.0

5 in

43.7

1 in

0 10 20 30 40 50 60 70

CMS

CMB

SM°

BM°

kW (T.air 25°C - T.cond 40°C)

CSE 350 R134a

0 10 20 30 40 50 60 70 80

CMS

CMB

SM°

BM°

kW (T.air 25°C - T.cond 40°C)

CSE 350 R410A

0 10 20 30 40 50 60

CMS

CMB

SM°

BM°

kW (T.air 25°C - T.liq 40/35°C)

WTE 350

24.01 in (single row of fans)

45.67 (single row of fans)

67.32 (single row of fans)

45.67 (double row of fans)

67.32 (double row of fans)