cs 3: harvard science center library - ningapi.ning.com/files/7ergvsk6zfpn0*vjjc5qufi3mibkra... ·...

44
DIVA DAY 2012 Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras RETROFITTING LIBRARIES FOR DAYLIGHTING WORK ENVIRONMENTS/TRANSITION SPACES case study: Harvard Cabot Science Library HARVARD_MIT

Upload: phamtruc

Post on 18-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

DIVA DAY 2012

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

RETROFITTING LIBRARIES FOR DAYLIGHTING WORK ENVIRONMENTS/TRANSITION SPACES

case study: Harvard Cabot Science Library

HARVARD_MIT

DIVA DAY 2012

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

MIT 4.430: Daylighting

HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

DESCRIPTION OF THE PROJECT _DAYLIGHT IN LIBRARIES

HELSINKY PENSIONS INTITUTE

SEINAJOKI PUBLIC LIBRARY

DIVA DAY 2012 HARVARD_MIT

DESCRIPTION OF THE PROJECT _LIBRARIES_REQUIREMENTS

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

1 foot candle (ftcd, fcd) = 1 lumen / sq ft = 10.752 lux

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

DESCRIPTION OF THE PROJECT _LIGHT TRANSITION IN LIBRARIES

VIIPURI PUBLIC LIBRARY

Alvar Aalto

1935

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

DESCRIPTION OF THE PROJECT _LIGHT TRANSITION IN LIBRARIES

MICHELANGELO

ASPLUND

AALTO

DIVA DAY 2012 HARVARD_MIT

DESCRIPTION OF THE PROJECT _LIBRARIES_CONTEXT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

IMPORTANCE OF DAYLIGHTING INHERITED FROM TRADITIONAL LIBRARY, BECAUSE OF A HIGH REQUIREMENT FOR READING.

DIGITAL MEDIA AND INFORMATION PRODUCED A

WHY LIBRARIES?

DOUBLE SHIFT

A L

L

L

M

L.A.M

BOOK USER

RETROFIT PROCESS

DIVA DAY 2012 HARVARD_MIT

HARVARD UNIVERSITY_LIBRARY PROJECT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

_SUSTAINABILITY GOALS

‘College Library Offices Meet Green Office Challenge.’

Harvard Gazette, 12 Feb 2011

‘Harvard is making public the information on more than 12 mil. books inside its 73 libraries.’

New York Times, 24 Apr 2012

DIVA DAY 2012 HARVARD_MIT

HARVARD LIBRARIES_SEARCH OF THE CASE STUDY

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

��

_THE BUILDING

DIVA DAY 2012 HARVARD_MIT

CASE STUDY_THE SCIENCE CENTER LIBRARY

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

HARVARD GSD J.Andrews 1972

LANGDEL HALL SR&C 1907

WIDENER LIBRARY J.F.Abele 1915

SCIENCE-CENTER J.L.Sert 1970

_THE BUILDING

DIVA DAY 2012 HARVARD_MIT

CASE STUDY_THE SCIENCE CENTER LIBRARY

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

LIBRARY+READING Original 1970

HISTORY OF SCIENCE Addition 2005

Existing: 291,000 sq. ft Additions: 26,814 sq. ft.

_THE BUILDING

DIVA DAY 2012 HARVARD_MIT

CASE STUDY_THE SCIENCE CENTER LIBRARY

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

_READING ROOMS PLANS

FLOORPLAN 2 Main reading room, study and stacks

FLOORPLAN 1 Access, stacks, reading and office

READ STACK GROUP

ACCESS

READ STACK

OFFICE ACCESS

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

CASE STUDY_THE SCIENCE CENTER LIBRARY _READING ROOMS

FLOORPLAN 2 Main reading room, study and stacks

FLOORPLAN 1 Access, stacks, reading and office

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

CASE STUDY_THE SCIENCE CENTER LIBRARY _READING ROOMS

FAÇADE READING AREA 18 MARCH 2012, 17:00 h

SECTION AA

350 lux

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

CASE STUDY_THE SCIENCE CENTER LIBRARY _READING ROOMS

INTERIOR READING AREA 2 18 MARCH 2012, 17:00 h

SECTION AA

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

CASE STUDY_THE SCIENCE CENTER LIBRARY _TRANSITION SPACES

1500 LUX

400 LUX

350 LUX

1200 LUX

250 LUX

100 LUX

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

INTRODUCE DAYLIGHT TO THE DEEP PLAN

Obtain a minimun illuminance of 500 lux for the whole reading room area, and distribute uses accordingly.

ADAPT SPACE FOR COMPUTER USE

Avoid all direct sunlight coming from the façade by redesigning the shading system. Reduce space contrast and glare for work spaces using an dynamic facade

CASE STUDY_THE SCIENCE CENTER LIBRARY _OBJECTIVES

DESIGN A TRANSITION SPACE

Use the existing library distribution to generate a sequence of exposures to daylighting from the dark entrance to the extremely bright reading areas.

REDUCE THE ENERGY USE FOR LIGHTING

Quantify the reduction of electricity use with the introduction of daylighting.

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

METHODOLOGY PROCESS FOR LIBRARY REDESIGN

SPACE ASSESMENT OF THE READING ROOM

1. Illuminance levels simulation (DIVA for Rhino) 2. Shading system study (Ecotect, DIVA for Rhino) 3. Glare DGP analysis (DIVA + Evaglare) 4. User behaviour survey

A.

NEW READING ROOM PROPOSAL B. 1. Façade shading redesign 2. Skylight design 3. Physical model heliodon study

ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS C. 1. Façade shading illuminance study (DIVA for Rhino) 2. Dynamic façade and glare study (DIVA for Rhino + Evaglare) 3. Skylight variation performance (DIVA for Rhino) 4. Daylight autonomy study for new design (DIVA for Rhino)

TRANSITION SPACE PROPOSAL D.

ENERGY SAVING ESTIMATION E.

CASE STUDY_THE SCIENCE CENTER LIBRARY _METHODOLOGY

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

A.SPACE ASSESMENT _ILLUMINANCE LEVELS SIMULATION

CASE0: ORIGINAL STATE Description scpace

FLOOR PLAN (2ndroom)

SECTION(2ndroom)

Bookshelf Dark Grey plastic

0.4,0.4,0.4

Interior Wall White Paint

0.65,0.65,0.65

Glazing Double clear

85%

Structure White Paint 0.7,0.7,0.7

Furniture Wood Clear 0.30,0.25,0.16

Flooring Grey Carpet 0.12,0.11,0.09

Mullions White Paint 0.7,0.7,0.7

Louvers and fin White Reflecting

0.75,0.75,0.75

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

A.SPACE ASSESMENT _ILLUMINANCE LEVELS SIMULATION

12:00 21DEC

12:00 21SEP

12:00 21JUN 300

2500

CASE0: ORIGINAL STATE

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

20-35%

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

A.SPACE ASSESMENT _SHADING SYSTEM STUDY

CASE0: ORIGINAL STATE

Shading analysis with addition of shading satus along line parallel to facade

0.5 m Line A

1.5 m Line B

3.5 m Line C

5.0 m Line D

D

C

B

A

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

A.SPACE ASSESMENT _GLARE ANALYSIS IN WORK SPACES

CASE0: ORIGINAL STATE

DGP glare study with DIVA ab 4 ad 1000 as 20 ar 100 aa 0.1

A

B

DGP 100 21DEC 9:00

DGP 45 21DEC 12:00

DGP 100 21DEC 9:00

DGP 45 21DEC 12:00

A

B

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

A.SPACE ASSESMENT _SURVEY ON USERS

FLOORPLAN 2

FLOORPLAN 1

_WHERE DO PEOPLE SIT?

Close to windows Far from windows

50% 70% 30%

_WHY THERE?

Close

Far

50% Views

70% More light

30% Less distraction

20%

20%

More privacy

Less glare

_DISCOMFORT CLOSE TO WINDOWS?

40% Lack of light

45% Excess of light

_TYPES OF USERS

Laptop

Laptop Notes, books

Notes, books

L + N/B

DURING THE SEMESTER

EXAM PERIOD

• PEOPLE SITTING CLOSE TO THE WINDOWS LEAVE FASTER

• SMALL AMOUNT OF TASK LIGHTS AVAILABLE_USED

• COMPLAINTS CLOSE TO WINDOWS ABOUT EXCESS/LACK OF LIGHT

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

B.NEW READING ROOM PROPOSAL _PROPOSAL DESCRIPTION

FLOORPLAN 2 Main reading room, study and stacks

READ WORK

GROUP ACCESS

MEZZANINE New reading/working area

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

B.NEW READING ROOM PROPOSAL

SECTION A SECTION C

SECTION B

C B A

1

2 3

_PROPOSAL DESCRIPTION

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

B.NEW READING ROOM PROPOSAL

A

B

C

_PROPOSAL DESCRIPTION

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

B.NEW READING ROOM PROPOSAL _SKYLIGHT DESIGN

Tilted surface to optimize the light capture, according to the summer solar angle

Interior parabolic reflective surface to improve the channel of the sunlight to the interior space

Optimized exterior operable louvers in distance and size, to avoid the direct sunlight

FINAL SKYLIGHT DESIGN

Horizontal louvers_ Still direct sunlight in winter with low angles Louvers at 45º_ Avoid direct sunlight with low angles

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

B.NEW READING ROOM PROPOSAL _HELIODON ANALYSIS

INTERIOR MODEL

FACADE PROPOSAL

SOUTH

NORTH

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

������� �������� �������

������� �������� �������

Measurements – 22nd June

B.NEW READING ROOM PROPOSAL _HELIODON ANALYSIS

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _FACADE SHADING AND ILLUMINANCE ANALYSIS

1.5 m Line A

5.0 m Line B

1.5 m Line A

5.0 m Line B

CASE1: OPEN LOUVERS

CASE2: CLOSED LOUVERS

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _ILLUMINANCE LEVELS SIMULATION

300

2500

12:00 21DEC

12:00 21SEP

12:00 21JUN

CASE1: FAÇADE + HORIZONTAL LOUVERS

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

15-25%

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _ILLUMINANCE LEVELS SIMULATION

300

2500

12:00 21DEC

12:00 21SEP

12:00 21JUN

CASE2: FAÇADE + LOUVERS 45 DEGREES

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

10-20%

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _SKYLIGHT VARIATION PERFORMANCE

300

2500

12:00 21DEC

12:00 21SEP

12:00 21JUN

CASE1: NORTH SKYLIGHT

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

35%

500

500

500

500

90% 100%

2500

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _SKYLIGHT VARIATION PERFORMANCE

300

2500

12:00 21DEC

12:00 21SEP

12:00 21JUN

CASE2A: SOUTH SKYLIGHT 00

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

100% 90% 100%

500 500

2500

2500 2500

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _SKYLIGHT VARIATION PERFORMANCE

300

2500

12:00 21DEC

12:00 21SEP

12:00 21JUN

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

CASE2B: SOUTH SKYLIGHT 45

100% 100% 100%

500 500

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _DYNAMIC FAÇADE AND GLARE STUDIES

DGP 23 21DEC 9:00

DGP 25 21DEC 09:00

DGP 37 21JUN 09:00

DGP 27 21JUN 09:00

A B

DGP 38 21DEC 09:00

DGP 21 21JUN 09:00

C

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _DYNAMIC FAÇADE AND GLARE STUDIES

CASE2A. BACK TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

CASE2B. BACK TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

CASE2 A+B. BACK TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _DYNAMIC FAÇADE AND GLARE STUDIES

CASE2A. FRONT TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

CASE2B. FRONT TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

CASE2 A+B. FRONT TABLE: ANNUAL GLARE DGP DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _DAYLIGHT AUTONOMY STUDY FOR NEW DESIGN

0

100

Average 66%

DYNAMIC SHADING 2 STATE: 0deg/45deg

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1 9 hours

80% (over 50%DA)

500-2500

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

C.ILLUMINANCE AND GLARE QUANTITATIVE ANALYSIS _DAYLIGHT AUTONOMY STUDY FOR NEW DESIGN

0

100

Average 80%

DYNAMIC SHADING 3 STATE: 0deg/40deg/50deg

DIVA simullation ab 4 ad 1000 as 20 ar 100 aa 0.1 15 hours

99% (over 50%DA)

500-2500-3000

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

D. TRANSITION SPACES _MEAN ILLUMINANCE

21 JUNE 12pm

1018 lux/m2 (0-1000)

177 lux/m2 (0-500)

674 lux/m2 (0-1000)

199 lux/m2 (0-500)

71 lux/m2 (0-500)

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

E.ENERGY SAVING ESTIMATION _ENERGY SAVING ESTIMATION

1

2 3

1

��

�����

�����

�����

�����

����

����

�����

�����

����

������

9000

1500

800

kWh/year

A B C

A. ORIGINAL. NO DIMMING B. ORIGINAL. DIMMING C. NEW. DIMMING

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

E.ENERGY SAVING ESTIMATION _ENERGY SAVING ESTIMATION

ZONE 1: WINDOW AREA 1200 W installed (15 W/m2)

340 kWh year

ZONE 2: BELOW PLATFORM 540 W installed (15 W/m2)

280 kWh year

ZONE 3: INTERIOR 810 W installed (15 W/m2)

193 kWh year

DIVA DAY 2012 HARVARD_MIT

Day-lighting in library retrofitting_ Transition spaces: Harvard SCIENCE CENTER_ Carlos Cerezo | Natalia Escobar | Amaia Puras

Thank you

Carlos Cerezo Master in Design Studies_ Energy and Environments

[email protected]

Natalia Escobar Master in Design Studies_ Critical Conservation

[email protected]

Amaia Puras Master in Design Studies_ Energy and Environments

[email protected]

HARVARD_MIT DIVA DAY 2012