cs-2000 technical brochure - 0714

6
Phone: 866.346.5665 | Fax: 314.426.1967 | www.dynaflex.com New Components! Class III Class II “The CS-2000 is an indispensable appliance in my treatment of Class III malocclusion.” Dr. Ted Bennion, DMD MS “A great appliance for Class II and Class III cases. Easy to place and highly effective!” Dr. Eric W. Brust, DDS MS Easy To Place Little To No Maintenance Increased Performance Increased Control Up to 5mm of Correction • 350 Grams of Low Continuous Force Industry leading system for more than 8 years with over 20,000 successful cases.

Upload: dynaflex

Post on 01-Apr-2016

232 views

Category:

Documents


2 download

DESCRIPTION

Updated version of the CS-2000 Class II & II Corrector

TRANSCRIPT

Page 1: CS-2000 Technical Brochure - 0714

CS-2OOO®

Phone: 866.346.5665 | Fax: 314.426.1967 | www.dynaflex.com

New Components!

Class III

Class II

“The CS-2000 is an indispensable appliance in my treatment of

Class III malocclusion.” Dr. Ted Bennion, DMD MS

“A great appliance for Class II and Class III cases. Easy to

place and highly effective!” Dr. Eric W. Brust, DDS MS

• Easy To Place

• Little To No Maintenance

• Increased Performance

• Increased Control

• Up to 5mm of Correction

• 350 Grams of Low Continuous Force

Industry leading system for more than 8 years with over 20,000 successful cases.

Page 2: CS-2000 Technical Brochure - 0714

Your Class II & Class III SolutionThis revolutionary system will guarantee results with your Class II and Class III orthodontic cases.

The CS-2000® Niti springs are a DynaFlex® exclusive, utilizing a patented, low-continuous force (350 grams), closed coil spring and a specially built “key-hole” end which fits over a

patented slotted base pivot similar to a Herbst® housing nut.

* For detailed information on Class III Correction, reference: “Class III correction using an inter-arch spring loaded module”.

Robert VanLaecken, DDS M.S., West Virginia University, Department of Orthodontics.

PUBLISHED ARTICLEClass III correction using an inter-arch

spring-loaded moduleVisit www.dynaflex.com/cs-2000-information/

Authors: Robert Vanlaecken, Michael O Williams, Thomas Razmus, Erdogan Gunel, Chris Martin, Peter Ngan

Journal: Progress in Orthodontics

Position (mm)

600

500

400

300

200

100

0

Load

(g)

10 20 30 40 50 60

CS-2000® SPRING

AFTER

Case photos compliments of Dr. Andy Hayes of St. Louis, MO

BEFORE

NEWLY RE-DESIGNED:The newly designed collared pivot allows for an arch wire to slide easily through the base

and reduces the possibility of abrasion. The new hybrid screw can be active or passive allowing you the ability to lock the pivot to the archwire, if desired. The pivot is designed to be used on the archwire or can also be welded to a band or crown for amazing versatility.

• Improved Performance• Simple• Effective• Guaranteed Results

Page 3: CS-2000 Technical Brochure - 0714

Easy 10 minute Step By Step Instructions for Archwire Placement

Class II Class IIISTEP 1:

Place 2 pivots on the upper archwire, position pivots distal

to the upper canines, insert and ligate archwire.

STEP 1: Place 2 pivots on the lower archwire, position pivots distal to the lower canines, insert and ligate archwire.

STEP 2: Outside the mouth, assemble two

spring, screw and pivot combinations. To guarantee pivot will slide onto

archwire, do not over tighten screw at this point. Place assembled components

onto the lower archwire. Insert and ligate archwire, positioning the pivots

mesial to the lower first molars. Now, tighten screw as needed.

STEP 2: Outside the mouth, assemble two spring, screw and pivot combinations. To guarantee pivot will slide onto archwire, do not over tighten screw at this point. Place assembled components onto the upper archwire. Insert and ligate archwire, positioning the pivots mesial to the upper first molars. Now, tighten screw as needed.

STEP 3: Using a hemostat, stretch spring eyelet onto the upper pivot and

secure in place with a screw.

STEP 3: Using a hemostat, stretch spring eyelet onto the lower pivot and secure in place with a screw.

UPPER ARCH

LOWER ARCH

For use in a passive position, simply break off the tip of the hybrid screw, allowing the pivot to move freely along archwire. For use in the active position, simply insert the screw into pivot and tighten to lock into desired position on the archwire.

Will actively lock on archwires larger than .016 x .022

TIPSAt subsequent visits,

reposition the pivots or change from 10mm springs to 7mm springs for

further activation.

In the resting jaw position the spring should have less than

2mm of activation.

Page 4: CS-2000 Technical Brochure - 0714

Example of Laboratory Options

There are multiple options to use CS-2000® in Class II & III along with upper and lower fixed appliances.

(upper view) (lower view)(laboratory option)

The CS-2000® Appliance has been used successfully for over 8 years with thousands of patients seeing remarkable

results with little to no compliance necessary.

Results Matter

Class III Treated Case

Class II Treated Case

Case photos compliments of Dr. Michael Williams of Gulfport, MS

BEFORE

AFTER

See CS-2000 educational animations

at www.dynaflex.com

Use your QR code reader to view or download a prescriptionor visit www.dynaflex.com.

BEFORE

PROGRESS

AFTER

Page 5: CS-2000 Technical Brochure - 0714

Sterilizable Allen Pencil (optional)

CS-2000® 5-Patient Kit

Wire inserted into pivot

Screw

Pivot

10 mm 7 mmNiti Springs

#3800-5E 5-Patient Kit - 10mm $349.00 includes 10 (10mm) CS-2000 Niti Springs, 20 slotted pivots, 20 hybrid screws & an Allen Pencil

#3815-7E 5-Patient Kit - 7mm $349.00 includes 10 (7mm) CS-2000 Niti Springs, 20 slotted pivots, 20 hybrid screws & an Allen Pencil

#3800-10E 10-Patient Kit - 10mm $649.00 includes 20 (10mm) CS-2000 Niti Springs, 40 slotted pivots, 40 hybrid screws & an Allen Pencil

#3809 CS-2000® Niti Spring 10mm $17.50 each

#3811 CS-2000® Niti Spring 7mm $17.50 each

#3810-E Pivot with Slotted Base .022 x .025 $10.00 each

#3815-5E Screw for pivot $1.95 each

#3823-E Allen pencil (sterilizable) $28.50

Part # Description Price

“The Dynaflex® CS-2000® appliance has greatly improved our abilities to correct Class III malocclusions. We love how easy it is to place and it is as durable a product as I have used for inter-arch correction. The design is excellent and we have improved our overall results while shortening our treatment time using this product. We do really enjoy using these appliances, and they have not only held-up well, they really work.”

– Dr. Anthony Harwell and Dr. Tony Harwell

To Order: 866.346.5665 or www.dynaflex.com

Page 6: CS-2000 Technical Brochure - 0714

“The CS-2000® is by far the most efficient and

patient-friendly appliance on the market for dental

correction of Class III malocclusions.

For my nonsurgical adolescent and

adult class III patients, you could

say “it’s the only

game in town.”

Dr. Andy Hayes, DDS, MSD

St. Louis Orthodontic Group

P.O. Box 99 St. Ann, MO 63074866-346-5665

031114 © 2014 DynaFlex® , St. Louis, MO 63074. Printed in U.S.A. All rights reserved. It is a violation of copyright law to reproduce all or part of this material, including photography, without the permission of DynaFlex®. CS-2000® patent pending. Spring Patent 6719557

“The introduction of the CS-2000® springs has been an extraordinary addition to our practice. Patient compliance

with elastics is no longer an issue!”

Dr. Mel Collazo DDS, MS, PA Collazo Orthodontics • Little Rock, Arkansas

Quickly Becoming The MOST ADVANCED & EASIEST TO USE

Class II & Class III Corrector Available Today!

Case photos compliments of Dr. Andy Hayes of St. Louis, MO

BEFORE PROGRESS AFTER

PROVEN RESULTS!