Crystal Structure Determination and Refinement Using the Bruker AXS SMART APEX II System. Charles Campana Bruker AXS Inc. Flowchart for Method. Adapted from William Clegg “Crystal Structure Determination” Oxford 1998. Crystal Growing Techniques. Slow evaporation Slow cooling - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Crystal Structure Determination Crystal Structure Determination and Refinement Using the and Refinement Using the Bruker AXS SMART APEX II Bruker AXS SMART APEX II

SystemSystem

Charles CampanaBruker AXS Inc.

Page 2: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Flowchart for MethodFlowchart for Method

Interpret the results

Complete and refine the structure

Solve the structure

Data reduction

Measure intensity data

Evaluate crystal quality; obtain unit cell geometryand preliminary symmetry information

Select, mount, and optically align a suitable crystal

Adapted from William Clegg

“Crystal Structure Determination”

Oxford 1998.

Page 3: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Crystal Growing TechniquesCrystal Growing Techniques

Slow evaporation

Slow cooling

Vapor diffusion

Solvent diffusion

Sublimation

http://laue.chem.ncsu.edu/web/GrowXtal.html

http://www.as.ysu.edu/~adhunter/YSUSC/Manual/ChapterXIV.pdf

Page 4: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Examples of CrystalsExamples of Crystals

Page 5: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Growing CrystalsGrowing Crystals

Kirsten Böttcher and Thomas Pape

Page 6: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Select and Mount the CrystalSelect and Mount the Crystal

Use microscope

Size: ~0.4 (±0.2) mm

Transparent, faces, looks single

Epoxy, caulk, oil, grease to affix

Glass fiber, nylon loop, capillary

Page 7: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

What are crystals ?What are crystals ?

Page 8: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Crystallographic Unit CellCrystallographic Unit Cell

Unit Cell Packing Diagram - YLID

Page 9: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

7 Crystal Systems - Metric 7 Crystal Systems - Metric ConstraintsConstraints

Triclinic - none Monoclinic - = = 90, 90 Orthorhombic - = = = 90 Tetragonal - = = = 90, a = b Cubic - = = = 90, a = b = c Trigonal - = = 90, = 120, a = b

(hexagonal setting) or = = , a = b = c (rhombohedral setting)

Hexagonal - = = 90, = 120, a = b

Page 10: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

X-Ray Diffraction Pattern X-Ray Diffraction Pattern from Single Crystalfrom Single Crystal

Rotation Photograph

Page 11: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

X-Ray DiffractionX-Ray Diffraction

X-ray beam

1Å(0.1 nm)

~ (0.2mm)3 crystal~1013 unit cells, each ~ (100Å)3

Diffraction pattern onCCD or image plate

Page 12: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Bragg’s lawBragg’s law

We can think of diffraction as reflection at sets of planes running through the crystal. Only at certain angles 2 are the waves diffracted from different planes a whole number of wavelengths apart, i.e. in phase. At other angles the waves reflected from different planes are out of phase and cancel one another out.

n = 2d sin()

d

Page 13: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Reflection IndicesReflection Indices

These planes must intersect the cell edges rationally, otherwise the diffraction from the different unit cells would interfere destructively.

We can index them by the number of times h, k and l that they cut each edge.

The same h, k and l values are used to index the X-ray reflections from the planes.

z

y

x

Planes 3 -1 2 (or -3 1 -2)

Page 14: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Diffraction PatternsDiffraction Patterns

Two successive CCD detector images with a crystal rotation of one degree per image

For each X-ray reflection (black dot) indices h,k,l can be assigned and an intensity I = F 2 measured

Page 15: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Reciprocal spaceReciprocal space

The immediate result of the X-ray diffraction experiment is a list of X-ray reflections hkl and their intensities I.

We can arrange the reflections on a 3D-grid based on their h, k and l values. The smallest repeat unit of this reciprocal lattice is known as the reciprocal unit cell; the lengths of the edges of this cell are inversely related to the dimensions of the real-space unit cell.

This concept is known as reciprocal space; it emphasizes the inverse relationship between the diffracted intensities and real space.

Page 16: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

The structure factor The structure factor FF and and electron density electron density

Fhkl = V xyz exp[+2i(hx+ky+lz)] dV

xyz = (1/V) hkl Fhkl exp[-2i(hx+ky+lz)]

F and are inversely related by these Fourier transformations. Note that is real and positive but F is a complex number: in order to calculate the electron density from the diffracted intensities I = F2 we need the PHASE ( ) of F. Unfortunately it is almost impossible to measure directly!

Page 17: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

The Crystallographic Phase The Crystallographic Phase ProblemProblem

Page 18: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

The Crystallographic Phase The Crystallographic Phase ProblemProblem

In order to calculate an electron density map, we require both the intensities I = F 2 and the phases of the reflections hkl.

The information content of the phases is appreciably greater than that of the intensities.

Unfortunately, it is almost impossible to measure the phases experimentally !

This is known as the crystallographic phase problem and would appear to be insoluble

Page 19: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Real Space and Reciprocal Real Space and Reciprocal SpaceSpace

Real Space Unit Cell (a, b, c, ,

, ) Electron Density,

(x, y, z) Atomic Coordinates –

x, y, z Thermal Parameters

– Bij

Bond Lengths (A) Bond Angles (º) Crystal Faces

Reciprocal Space Diffraction Pattern Reflections Integrated

Intensities – I(h,k,l) Structure Factors –

F(h,k,l) Phase – (h,k,l)

Page 20: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

Goniometer HeadGoniometer Head

Page 21: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

3-Axis Rotation (SMART)3-Axis Rotation (SMART)

Page 22: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

3-Axis Goniometer3-Axis Goniometer

Page 23: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

SMART APEX II SystemSMART APEX II System

Page 24: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

SMART APEX SystemSMART APEX System

Page 25: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

SMART APEX II SystemSMART APEX II System

Page 26: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

APEX II detectorAPEX II detector

Page 27: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

CCD Chip SizesCCD Chip Sizes

Kodak 1K CCD 25x25 mm SMART 1000, 1500

& MSC Mercury

SITe 2K CCD 49x49 mmSMART 2000

4K CCD 62x62 mm

X8 APEX, SMART APEX, 6000, 6500

Page 28: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

APEX II detectorAPEX II detector transmission of fiber-optic

taper depends on 1/M2

APEX with direct 1:1 imaging 1:1 is 6x more efficient than

2.5:1 improved optical transmission

by almost an order of magnitude

allowing data on yet smaller micro-crystals or very weak diffractors.

original SMART 17 e/Mo photon APEX 170 e/Mo ph.

Page 29: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

project database

default settings

detector calibration

SMART

setup

sample screening

data collection

ASTRO

data collection strategy

SAINTPLUS

new project

change parameters

SAINT: integrate

SADABS: scale & empirical absorption correction

SHELXTL

new project

XPREP: space group determination

XS: structure solution

XL: least squares refinement

XCIF: tables, reports

Page 30: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

                         

                          

George M. Sheldrick Professor, Director of Institute and part-time programming technician

1960-1966: student at Jesus College and Cambridge University, PhD (1966)    with Prof. E.A.V. Ebsworth entitled "NMR Studies of Inorganic Hydrides"1966-1978: University Demonstrator and then Lecturer at Cambridge University; Fellow of Jesus College, CambridgeMeldola Medal (1970),  Corday-Morgan Medal (1978)1978-now: Professor of Structural Chemistry at the University of GoettingenRoyal Society of Chemistry Award for Structural Chemistry (1981)Leibniz Prize of the Deutsche Forschungsgemeinschaft  (1989)Member of the Akademie der Wissenschaften zu Goettingen (1989)Patterson Prize of the American Crystallographic Association (1993) Author of more than 700 scientific papers and of a program called SHELX Interested in methods of solving and refining crystal structures (both small molecules and proteins) and in structural chemistry

email:  [email protected]:  +49-551-392582

Page 31: Crystal Structure Determination and Refinement Using the  Bruker AXS SMART APEX  II System

SHELXTL vs. SHELX*SHELXTL vs. SHELX*http://shelx.uni-ac.gwdg.de/SHELX/index.htmlhttp://shelx.uni-ac.gwdg.de/SHELX/index.html

SHELXTL (Bruker Nonius) XPREP XS XM XE XL XPRO XWAT XP XSHELL XCIF

SHELX (Public Domain)* None SHELXS SHELXD SHELXE SHELXL SHELXPRO SHELXWAT None None CIFTAB