cryo - panasonic cryopreservation brochure supplied by ri uk and ireland

20
l Total Cryopreservation solutions l Best uniform storage temperatures l Dry storage systems Extreme temperatures require the most reliable equipment Securing samples, changing lives

Upload: ri-uk-ireland

Post on 25-May-2015

330 views

Category:

Technology


5 download

DESCRIPTION

Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

TRANSCRIPT

Page 1: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

l Total Cryopreservation solutions

l Best uniform storage temperatures

l Dry storage systems

Extreme temperatures require the most reliable equipment

Securing samples,changing lives

Page 2: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Cryopreservation refers to the storage of a living organism

at ultra-low-temperature such that it can be revived and

restored to the same living state as before it was stored.

Indefinitely long storage times require that the organism be

maintained below the glass transition temperature of

aqueous solutions, approximately -130ºC, the temperature

at which frozen water no longer sublimes and

recrystallizes. Therefore -150°C freezers or liquid nitrogen

are required for longer storage times.

In order to make liquid out of gasses, scientists in the 19th

century discovered insulated bottles for storage and

transport. This type of vessel is still being used today.

For years cryopreservation in liquid nitrogen at -196°C

has been the standard for long term preservation.

During the years it became clear that cross contamination

became a real risk for this kind of preservation. Not only

through existing ice, but from sample to sample as well.

Scientific evidence has been delivered in the past about

examples of Hepatitis cross contamination.

That was the reason why storage in vapor phase became

more popular. Valuable samples were not stored in the

liquid nitrogen anymore, which eliminated the risks of cross

contamination.

The world of Cryopreservation

Panasonic Biomedical Sales Europe B.V. has established a worldwide reputation as a

manufacturer of high quality medical equipment over the past forty years. In this period we

became the leader in the European Ultra Low Temperature market. In this field Panasonic has

set the standard in many aspects. VIP panels, Cool Safe compressors and the world’s first -

152°C ULT freezer. Where Panasonic took the initiative, the others followed. Together with the

high standard of service we deliver it makes us a major player in the biomedical market.

Panasonic is your ideal ‘extreme low temperature’ partner. By working in Europe with

one of the leading brands Custom Biogenic Systems, we are able to offer complete solutions

for -86°C and cryopreservation storage.

2

Page 3: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

There are disadvantages of storage in vapor phase though:

1. loss of storage capacity; 1/3 of the vessel can not be

used any more

2. the vapor phase temperature is very much depending on

the level of liquid nitrogen

3. large vertical temperature gradients, can put valuable

samples at greater risk during long term storage.

To protect long term sample storage from cross

contamination and the risk of vertical gradients, dry storage

systems like -150°C ultra low temperature freezers and the

patented Isothermal Storage have been developed.

Hexagonal crystal

Cubic crystal

Amorphousice crystal

-80ºC

-130ºCRecrystallization

Point

-152ºC

Recrystallization mechanism 19th century insulated bottles for storage and transport.

liquid nitrogen

Cross contamination became a real danger for this kind of preservation.

Not only through existing ice, but fromsample to sample as well.

Storage in vapor phase became more popular.

Loss of storage capacity.The vapor phase temperature is verymuch depending on the level of liquidnitrogen. Large vertical temperature

gradients.

Dry storage system

No cross contamination risk through LN2. No large vertical

temperature gradients.

Isothermals orUltra-low -150ºC

Freezer

solution

Liquid Nitrogen storage or Dry storage?

3

Page 4: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

4

Isothermal LN2 Freezers

V-1500AB

V-3000AB

V-5000AB V-5000ABEH

liquid nitrogen jacket and provides the user with an easy

to read overview of the freezer temperature and status.

Sample SecurityA comprehensive alarm system with remote alarm contact

constantly monitors all aspects of the freezer’s operation.

Samples are also protected by lid and control panel locks.

The freezer can be monitored by a central BMS or

monitoring system.

Sample StorageA wide selection of inventory systems for vials and bags

are available to complete the system and optimize sample

storage.

The Isothermal ConceptThe sample storage area is cooled by a liquid nitrogen

jacket surrounding the stainless steel interior, and by

nitrogen vapour entering the freezer from the jacket via

directional vents. This patented technology provides

exceptional temperature uniformity in the -190°C range,

allowing the full freezer capacity to be used with

confidence. The circulation of vapour within the freezer

also results in less cold air loss during lid opening and

improved visibility. This allows full-width lids to be used

providing quick, unrestricted access to sample racks.

No Liquid Nitrogen ContactWith no liquid nitrogen in the storage area, samples can

be stored safely in the -190°C range without the risk of

cross-contamination through liquid nitrogen. The

Isothermal design also provides added user safety with no

splashing or contact of liquid nitrogen when removing

racks and samples from the freezer.

Automatic OperationIsothermal Freezers feature the Series 2301 Auto-fill and

Monitor System, which controls the automatic filling of the

Innovative CryopreservationNo Liquid Nitrogen Contact

VacuumInsulation

TemperatureControlledStorage Area

LiquidNitrogenEnvelope

Page 5: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Most important features of the 2301 controller -195˚C

-190˚C

Rotating carousels provide access to lower storage levels and maximisestorage space.

Use the retrieval tool to place and retrievecanisters quickly and easily.

The upper level provides a convenient work-space where canisters can be parked (shownin green) and samples inspected at -190°C.

Straw Storage Inventory SystemDesigned for the CBS V-1500AB and V-3000AB Isothermal Freezers, this patent-pending Inventory System provides an efficient solution for storingand working with straws, free from liquidnitrogen contact.

5

Featuresl Compatible with all on site automated LN2 supply systemsl Availble on all standard and Isothermal LN2 freezersl Programming of LN2 auto-fill levels and cyclesl Sequential filling capabilities, one-fill-all-filll Warm gas by-passl Output data to PC / Printer (USB Port and printer port)l RS-485 communication portl Cryomonitor software for freezer function and alarm downloadl System validation with print outl Key pad lockl Lid lock��

Front Panel Displayl System status displayl Liquid level inches / centimetersl Two level temperature display; at lid and inside storage spacel System status start / stop fill

Alarmsl Visual, audible and remotel High and low LN2 levels in jacketl Temperature deviationl Sensor and valve abnormalityl LN2 source / supplyl Remote alarm contactl Overflow sensor/alarm (optional)

V

All Isothermal models are certified to Medical Device Directive93/42/ECC: 1993 Class IIA

Page 6: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Ultra-low -150ºC freezer with third generation VIPinsulation.The freezer is equipped with Panasonic developed third

generation Vacuum Insulation Panels. This improved VIP

insulation is extremely efficient and results in a

-150ºC freezer with a capacity of 150 world standard

2” boxes, the largest capacity -150ºC freezer in the world!

New control panel with graphic LCD displayAll the alarm functions, self-diagnostic notifications and a

digital graph of the temperature are available in the new,

specially designed LCD display. The blue display provides

a clear image of the temperature and gives a notification

in the case of abnormalities in temperature, ambient

temperature, power supply etc.

New Cool Safe compressorsThe MDF-C2156VAN is equipped with Panasonic’s new

Cool Safe compressors. These compressors achieve a

10% higher energy conservation and the aerodynamically

designed and placed components in the refrigeration

compartment provide superior airflow, making it possible

to significantly reduce the stress to the freezer and

contributing to excellent durability.

Environmentally friendlyThe MDF-C2156VAN utilises binary mixed non-HCFC

refrigerants. The new Vacuum Insulation Panels and

double door gaskets reduce the power consumption.

6

Options

Temperature chart recorder (-170ºC to +30ºC) MTR-155H Chart paper RP-155 Ink pen DF-38FPMounting kit MDF-S30150Storage case MDF-49SCInventory racks see page 15

Ultra-low -150ºC Freezers MDF-C2156VAN

++++

+++++++++++ T T

VACUUM INSULATION

VIPPlus VIPPlus+

The worlds largestcapacity -150°C freezer.

(231 litres)

Page 7: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Specially designed compressor and cascaderefrigeration system for an ultra-low temperature of -152ºCHighly efficient compressors have been specially

developed and incorporated in the freezing unit. A

refrigeration circuit with the Cool Safe compressor

cascade refrigeration system enhances reliability of long-

term preservation. With a powerful low noise design

afforded by traditional ultra-low temperature technology,

this freezer delivers durable, stable cooling.

Microprocessor temperature control with LED digitaldisplay allows accurate temperature controlAccurate temperature setting, confirmation and operation

are all possible through microprocessor temperature

control with a LED digital display and flat key data entry.

The world’s first electronically controlled freezer, this model

maintains inner cabinet temperature at an ultra-low -152ºC

(ambient temperature of 30ºC), far lower than the

recrystallization point for pure water (-130ºC). This low

temperature provides the ideal preservation environment

for long-term storage.

ultra-low temperature environmentsCompressors continuously repeat highly compressed

operations, so lubricant oil is essential to prevent abrasion

and seizure. But when lubricant oil circulates in the

refrigeration circuit, piping becomes clogged and results in

compressor damage. Incorporating a high-efficiency oil

separator, the MDF-1156 effectively separates lubricant oil

from refrigerant, offering a stable ultra-low temperature

environment.

Various alarm and safety devices for protectingvaluable samplesMicroprocessor-controlled filter-clogged check function

protects the refrigeration circuit.

High temperature warning equipment automatically

indicates when the temperature deviates 15ºC from the

set temperature. The power failure alarm lamp and buzzer

are activated in case of power failure or irregular

temperature change. A remote alarm contact is fitted.

ATN models are also equipped with an auxiliary back-up

system for liquid nitrogen.

7

Small footprintLow operational costs

(128 litres)

MDF-1156 / MDF-1156ATN

Options

LCO2 backup system CVK-A (MDF-1156) LN2 backup system with recorder CVK-ATN2 (MDF-1156)

Temperature chart recorder (-170ºC to +30ºC ) MTR-155H Chart paper RP-155 Ink pen DF-38FPStorage case MDF-49SCInventory racks see page 15

Page 8: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

The Isothermal Carousel Liquid Nitrogen Vapor Storage

System combines the innovative -190°C Isothermal

design with a small opening and an interior rotating

carousel. The small opening provides low liquid nitrogen

consumption, a lightweight, user-friendly lid and a

consistently low temperature in the freezer. The interior

carousel is rotated by a unique ratcheting handle on top

of the freezer that will position samples to the front of the

freezer, even with the lid on.

Each Isothermal Carousel system includes the advanced

2301 auto- fill/monitoring controller to provide security

and ease of operation.

There are several Isothermal Carousel models available

and an extensive selection of inventory racks to store any

size tube, vial, box, microplate, etc. to complete the

system. Custom congurations can also be designed to

meet any requirement.

l No need to remove one rack to retrieve another rack.l No unnecessary exposure to room temperatures.l Carousel is rotated from the outside of the freezer

eliminating the risk of injury or temperature fluctuations.l Exceptional temperature uniformity.l Easy access to samples from the front of the freezer.l Removable console allows for complete access to the

sample storage space if necessary.l CBS Isothermal Carousel freezers are cooled by a

PATENTED liquid nitrogen jacket, with no liquid in thesample storage space.

l The only true DRY STORAGE FREEZER available.l No risk of cross-contamination through liquid nitrogen

contact or the need for special packaging.l The isothermal design also provides added user-safety

eliminating contact or splashing of liquid nitrogen.l Manufactured to ISO 13485 Standards.

8

Easy access to samplesfrom the front of the

freezer

Isothermal Carousel

Page 9: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Five liquid Nitrogen freezers are available ranging in sizes

from 90 litres to 720 litres, with sample storage capacities

up to 40,000 2 ml vials or over 3,500 blood bags. Each

unit includes a liquid level auto-fill and alarm system to

provide security, ease of operation, plus flexibility to

operate vapor storage, immersion storage or a

combination of both to store any type or size of sample.

An extensive selection of standard inventory racks or

canisters and frames are available to complete the

system. Custom configurations can also be designed to fit

any requirements.

l Standard LN2 Freezers include the 2301 controller

Standard liquid Nitrogen freezers are designed

to meet temperature, storage and security

specifications required by laboratories storing

frozen samples at cryogenic temperatures.

9

Standard Square rackconfiguration 1500AB

Standard LN2 Freezers

Page 10: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Standard system Includes:l Laptop computer with 2100

software

l Freezing chamber

l Choice of sample rack

l 1.2 m LN2 transfer hose

Options:l Choice of sample racks for

vials, tubes, straws, bags &

canes

l Temperature probes for

different sample types

l Roller Cart

The 2101 controlled rate freezer comes equipped with a dedicated laptop and

2100 programming software as standard to provide the highest levels of

flexibility and user convenience. Benefits include:

l Unlimited programming capability

l Multi-colour graph for sample, chamber and program temperature

l Sample or chamber temperature set-point control

l Continuous control status indication

l Programs and freeze data saved to hard drive or disc

l Password protected software

l Selectable password levels

l Searchable database for freeze run history

l Freeze run graphs and data available via any standard computer printer

l 30 data field available for each freeze run

l Continuous digital and graphical display of time and temperature during operation

l Audible and visual indicators for:

l End of each freeze run l Temperature probes l Freeze run tracking

l On screen help

The 2101 controlled rate freezer meets the highest standards for the programmed freezing of

biological samples. Computer controlled temperatures ensure your samples are frozen at

precisely the same rate during each run. Freeze protocols are controlled by either the chamber

or the sample temperature. The freezing rate can be programmed at the optimum rate for each

individual sample.

10

Controlled Rate Freezer

Page 11: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

11

Page 12: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

l ‘XC’, ‘Classic’ and ‘Value Added’ Series fulfil a wide

range of storage requirements

l Capacities from 210 to 6,000 2ml vials

l Advanced vacuum and insulation for maximum

thermal performance

l Durable, lightweight aluminium construction and roller

bases for easy mobility

l Storage solutions for vials and straws

l Easy access to store and retrieve samples

l Sample security with low-level alarm and lockable lids

(padlock not supplied)

‘XC’ Series – Compact Cryosystems for vial or straw

storage. With roller base and handle mounted low level

alarm.

‘Classic’ Series – Medium capacity storage for vials in

standard cryogenic boxes. With roller base and handle

mounted low level alarm.

‘Value Added’ Series – Same as ‘Classic’ Series but

with the low level alarm built into a lid

console.

Fabricated from durable, lightweight aluminum, the

shippers contain a hydro-phobic absorbent which holds

the liquid Nitrogen. The absorbent also repels moisture

and humidity, assuring the maximum holding time. A

protective shipping carton is available for all models which

protects the container from being placed on its side and

helps in withstanding the rigors of transportation. These

containers can be used to ship your samples with a "non-

hazardous" classification throughout the world.

The Vapor Shippers are designed for the safetransportation of biological samples atcryogenic temperatures.

Vapor Shippers

Cryosystems – Liquid Nitrogen Storage

12

Manual-fill Cryosystems provide versatile, low cost sample storage at cryogenictemperatures with maximum capacity and low liquid Nitrogen consumption.

Page 13: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Lab Tanks

The LAB Series dewars use high efficiency super-insulation

and aluminum construction to make them lightweight and

the most efficient containers available. Their shape and

handles make them easy to lift and pour. The LAB Series

dewars can also be fitted with pouring spouts, withdrawal

devices, or dippers to aid in liquid Nitrogen transfer.

13

The CF-9511 Transport container is also a high-

quality unit, primarily for use in moving samples

over shorter distances, such as from one lab to

another.

Lab-Tanks

Page 14: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Rack configurations

14

3101A-100S Vertical rack configuration 5000AB

Racks for all liquidnitrogen freezerapplications in

lightweight aluminum

Standard Square rackconfiguration 3000AB

Page 15: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Standard Square racks

V-1500AB 2001A-100S Aluminium Rack System with Cardboard Boxes + Dividers

S-1500AB 2001S-C81 "Comprises 7 Racks x 13 Boxes high. Max. Cap. 9.100 2ml Vials"

V-3000AB V-3000AB 3101A-100S Aluminium Rack System with Cardboard Boxes + Dividers

S-3000AB 3101A-100S "Comprises 17 Racks x 13 Boxes high. Cap. 22.100 2ml Vials"

V-5000AB 3301A-100S Aluminium Rack System with Cardboard Boxes + Dividers

S-5000AB 3301A-100S "Comprises 28 Racks x 13 Boxes high. Cap. 36.400 2ml Vials"

V-5000ABEH 3325A-100S Aluminium Rack System with Cardboard Boxes + Dividers

S-5000ABEH 3325A-100S "Comprises 28 Racks x 15 Boxes high. Cap. 42.000 2ml Vials"

Vertical racks

V-1500AB RC-V1500-1209-VLR Stainless Steel Rack System with Cardboard Boxes + Dividers

S-1500AB RC-S1500-1209-VLR "Comprises 20 Racks x 5 Boxes high. Cap. 10.000 2ml Vials"

V-3000AB V-3000AB RC-V3000-1209-VLR Stainless Steel Rack System with Cardboard Boxes + Dividers

S-3000AB RC-S3000-1209-VLR "Comprises 48 Racks x 5 Boxes high. Cap. 24.000 2ml Vials"

V-5000AB RC-V5000-1209-VLR Stainless Steel Rack System with Cardboard Boxes + Dividers

S-5000AB RC-S5000-1209-VLR "Comprises 80 Racks x 5 Boxes high. Cap. 40.000 2ml Vials"

V-5000ABEH RC-V5000EH-1208-VLR Stainless Steel Rack System with Cardboard Boxes + Dividers

S-5000ABEH RC-S5000EH-1208-VLR "Comprises 80 Racks x 6 Boxes high. Cap. 48.000 2ml Vials"

Boxes and dividersl Standard 2” and 3” boxes are available, in

sturdy moisture resistant cardboard.

l For the XC series cryosystems we have the

smaller 2” minibox including a 25 cell divider

(B2CM + D25M).

l Sturdy cardboard cell dividers come in a wide

selection of sizes to accommodate the

storage of a variety of tubes and vials.

Vertical racks for ULT -150 Freezers

MDF-1156 NIR209C Aluminium Rack System (Cardboard Boxes and Dividers are optional) compromises 9 racks x 9 boxes high. Cap. 8.100 2ml. Vials

MDF-C2156VAN NIR210C Aluminium Rack System (Cardboard Boxes and Dividers are optional) compromises 15 racks x 10 boxes high. Cap. 15.000 2ml. Vials

For other sizes racks and boxes, Canisters and Inventory Systems visit our website

15

Capacity is subject to rack type

Page 16: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Accessoires

16

CRYO-GLOVESMade from state-of-the art fabrics,Tempshield Cryo-Gloves® use a flexible,multi-layered insulated construction thatprovides maximum thermal protection, yetoffers comfort, flexibility, and dexterity so youcan perform tasks effectively and safely. Anadditional stay-dry lining keeps you warmand comfortable. Cryogenic Gloves protectyour hands and arms when working inhazardous, ultra-cold environments. Theinnovative design offers superior thermalprotection, while allowing for a maximumlevel of flexibility and dexterity—an essentialfeature when function is important and safetyis critical. Styles Include: Shoulder, Elbow,Mid-Arm, and Wrist US sizes: Small,Medium, Large, Extra-Large EN Sizes: 8, 9,10, 11.

LN2 PHASE SEPARATORDesigned to minimize hazardous splashingand vaporization, phase separators areavailable to use when transferring liquids intovarious open containers.

“Y” VALVEl 2 Male 1/2” NPT Brass Fittingsl 1 Female 1/2” NPT Stainless Steel

Flared Fittingl Overall Length Approximately 6”

“T” VALVEl Solid Brass Cryogenic shut-Off

Valve (Rated for temperatures from -196°C to 74° C)

l 2 Male 1/2” NPT Brass Fittingsl 1 Female 1/2” NPT Stainless Steel

Flared Fittingl Overall Length Approximately 11”

LN2 LEVEL STICKl 1/2 Centimeter and 1/4 Inch

Incrementsl Can withstand Temperatures up to

-190°Cl Measures up to 36”(92cm)

LN2 TRANSFER HOSEl Flexible Stainless Steel

constructionl 1/2” NPT Flared fitting on both

ends (3/8” I.D.)l 4’, 6’ lengths are available (custom

lengths are available upon request)

HOSE COVERS

CARDBOARD SLEEVESl 5 and 6 place sleeves for standard

2ml canel Cardboard construction

ROLLER BASECryosystem roller bases. Reinforcedfiberglass construction with casters.5 configurations available: 15” (magenta), 18”(blue), 18” (white, heavy duty), 20” (magenta),22” (blue), 26” (blue)

CANESl 2ml Canel 5 and 6 place vial canesl Lightweight aluminum constructionl Overall Length Approximately

11.5” (6 place cane)

Page 17: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

notes:1) Air temperature measured at freezer centre, ambient temperature +30°C, no load2) Requires Recorder MTR-155H3) Requires Sensor Cover MTR-C84) Requires Mounting Plate MDF-UBK5) CVK-A may also be used6) Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external projections 7) Nominal Value

MODELDimensionsExternal dimensions (W x D x H)6)

Internal dimensions (W x D x H)VolumeNet weight (approx)PerformanceCooling performance 1)

Temperature setting rangeTemperature control range 1)

ControlController

DisplayTemperature sensorRefrigerationRefrigeration system

High-stage compressorHigh-stage refrigerantLow-stage compressorLow-stage refrigerantInsulation materialInsulation thicknessAlarmsPower failureHigh temperatureLow temperatureFilterLid / door openConstructionExterior materialInterior materialInner door/lidOuter door/lid lockShelvesMax. load - per shelfMax. load - totalAccess port- position- diameterCastersElectrical and Noise LevelPower supplyNoise level 7)

OptionsSee page 161 for Inventory RacksDrawersSmall inner door kitTemperature recorders- Circular type- Continuous strip type- Recorder housing (if required)RS485 interface moduleLiquid CO2Back-upLiquid N2 Back-up

mm

mm

litres

kg

°C

°C

°C

W

W

mm

qty

qty

kg

kg

qty

Ø mm

qty

dB

qtySet of 2

-150°C/-152°C Freezers

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

Characteristics

MDF-1156-PE

1400 x 800 x 945

500 x 450 x 572

128

265

-152

-125 ~ -155

-130 ~ -152

LED

Pt-100

Cascade

1100

HFC

1100

HFC Mixed

PUF

175

V-B-R

V-B-R

-

V-B

-

Painted steel

Aluminium

1

Y

-

-

300

1

left

40

6 (2 leveling feet)

61

-

-

MTR-155H

-

-

CVK-AT2 2,5)

CVK-ATN2 2)

MDF-1156ATN-PE

1400 x 800 x 945

500 x 450 x 572

128

272

-152

-125 ~ -155

-130 ~ -152

LED

Pt-100

Cascade

1100

HFC

1100

HFC Mixed

PUF

175

V-B-R

V-B-R

-

V-B

-

Painted steel

Aluminium

1

Y

-

-

300

1

left

40

6 (2 leveling feet)

61

-

-

Supplied as standard

-

-

-

Supplied as standard

MDF-C2156VAN-PE

1730 x 765 x 1010

760 x 495 x 615

231

318

-150

-125~-152

-125 ~ -150

LCD

Pt-1000

Cascade with

auto-cascade

low-stage

1100

HFC

1100

HFC Mixed

PUF / VIP Plus

135

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Aluminium

2

Y

-

-

207

1

right

40

6 (3 leveling feet)

51

-

-

MTR-155H

MDF-S30150

MTR-480

Supplied as standard

l Long-term storage below recrystallisation pointl Safe storage without risk of cross contaminationl Reliable Panasonic Cool Safe compressorsl Low operational costs

230V 50Hz Single

Microprocessor Non-volatile memory

Specifications

17

600

1400

94

557

2

66

7

450

400

800

Dimensions MDF-1156

1010

1730

1125

760

615

11.5

53

495

465

802

105

924

765 46864

Dimensions MDF-2156VAN

Page 18: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Specifications

Isothermal CarouselGROUP

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding TimeDimensionsExternal dimensions (WxDxH)Usable interior height Usable interior diameter Weight emptyWeight fullMaximum CapacityMax. vial capacity (2ml)**Max. blood bag capacity (50ml)**

ltrltr/daysdays

mmmmmmkgkg

V-1500AB3056

660 x 939 x 1143736534148174

9100434

V-3000AB7098

939 x 1219 x 1206736787272327

221001120

V-5000AB93 118

1219 x 1371x 13207361016425500

403001936

V-5000ABEH1401112

1219 x 1371 x 14738641016453566

465002208

V3000-AB/C70

8

940 x 1219 x 1130686737272327

18000852

V3000EH-AB/C89

9

940 x 1219 x 1384889737288361

225001136

Isothermal -190˚C Dry Storage Freezers

** Cap

acity is sub

ject to rack typ

e

l Outstanding temperature uniformityl No LN2 in sample storage area

l No cross contaminationl Certified MDD 93/42/EEC:1993 Class IIA

Characteristics

Standard LN2 FreezersGROUP

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding TimeDimensionsExternal dimensions (WxDxH)Usable interior height Usable interior diameter Weight emptyWeight fullMaximum CapacityMax. vial capacity (2ml)**Max. blood bag capacity (50ml)**

ltrltr/daysdays

mmmmmmkgkg

S90-AB902.7533

457x 457x 96571140636109

5832266

S-1500AB145441

558x 787x 104173650870188

9100434

S-3000AB345749

863x 1092x 1066736787159438

221001120

S-5000AB615961

1117x 1320x12197361016227724

403001936

S-5000ABEH720980

1117x 1320x13978631016245827

465002208**

Cap

acity is sub

ject to rack typ

e

l Outstanding temperature uniformityl Liquid level auto-fill

l Alarm system to provide securityl Custom configurations possible

Characteristics

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding Time Working Volume Weight emptyWeight fullDimensionsNeck opening (mm) Overall height (mm) Outside diameter (mm) Canister DimensionsCanister height (mm) Canister diameter (mm) Maximum CapacityMaximum number of racksMaximum vial capacityMaximum number of canistersMaximum boxes per rackMaximum number of 1/2cc straws (10/cane) Maximum number of 1/2cc straws (1 level bulk)Maximum number of 1.2 & 2.0 mlvials (5/cane)AlarmLow-level alarm

ltrltr/daysdaysltrkgkg

mmmmmm

mmmm

qty

qty

Classic 2002610.85385126.382.5

216723559

--

42000-5-

-

-

standard

Classic 40021210.997011136.7136

2161003559

--

44000-10-

-

-

standard

Classic 60021750.9910416546.7193

2161003665

--

66000-10-

-

-

standard

Value added2001610.85386126.382.5

216723559

--

42000-5-

-

-

standard

Value added40011210.997011136.7136

2161003559

--

44000-10-

-

-

standard

Value added60011750.9910416546.7193

2161003665

--

66000-10-

-

-

standard

20/2020.50.09140

11.828.3

55.4652368

27941.9

--6-

780

1122

210

standard

34/1834.80.18123

15.443.5

89675464

27971

--6-

2100

3000

630

standard

47/1147.40.3976

16.454.6

127673508

279102

67506-

4500

6216

1320

standard

Classic Value added XC seriesGROUP

l Storage solutions foe vials and strawsl Easy access to store and retrieve samples

l Durable lightweight aluminium constructionl Capacities from 210 to 6.000 2ml vials

Characteristics

18

Page 19: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

MODELLN2 CapacityStatic Evaporation RateStatic Holding TimeWeight EmptyWeight FullNumber of CanistersMax Vial Capacity (2ml)Unit DimensionsOverall HeightOutside DiameterNeck OpeningUsable interior DimensionsInterior HeightInterior DiameterCanister HeightCanister Diameter

SC 2/1 V1.50.1982.7419

34318435

--

12731

SC 4/2 V3.60.261311171

106

46822270

--

27867

SC 4/3 V4.30.20211320148

49222251

--

27846

DS-3100.7143047-

500

584381216

317.5216--

CF-951110.53.331332--

431.8254228.6

228.6228.6--

ltrltr/daydayskgkg

mmmmmm

mmmmmmmm

GROUP

Characteristics l For shipment of “non-hazardous” samplesl Protecting shipping carton available

l Made of lightweight durable aluminum

Vapor Shippers Shipper

*Appearance and specification are subject to change without notice.

Controlled Rate FreezerGROUP

ModelDimensionsExterior (W x D x H)Interior (W x D x H)Effective capacityWeightPowerVoltageFrequencyCurrentMaximum Capacity2ml vials4ml / 5 ml vialsBag CanistersCanes

mmmmlitreskg

Characteristics

2101

485 x 648 x 743243 x 349 x 356

2834.7

220 - 240V50 Hz10A

65039020130

MODELLiquid Nitrogen CapacityStatic Evaporation Rate Static Holding Time Weight EmptyWeight FullMax. vial capacity (2ml)Exterior DimensionsNeck Opening Overall HeightOutside Diameter Overall opening Outside openingInterior DimensionsInterior DiameterUsable Height

Lab440.2182.76-

35.5426185

139198

Lab55

0.1533.348-

56463222

165266

Lab10100.1855.6614-

26546260

210343

Lab20210.18116.7926-

51627368

289348

Lab30320.251281238-

64611432

356378

Lab50500.451111556-

64779432

356559

ltrltr/daysdayskgkg

mmmmmmmmmm

mmmm

Lab tanksGROUP

Characteristics l For LN2 transportl High efficiency super insulation

l Easy to liftl Withdrawel device available

19

Page 20: Cryo - Panasonic cryopreservation brochure supplied by RI UK and Ireland

Extreme temperatures require the most reliable equipmen t

S-Series S-Series Cryo- V-Series ULT Freezersliquid vapor systems -190ºC -150ºC / -152ºC

Storage in ULT-Freezer xStorage in Dry Vapor of LN 2 xStorage in LN 2 x xStorage in vapor of LN 2 xCross contamination risk through LN 2 x xNo cross contamination risk through LN 2 x x xLarge temperature gradient risk xSmall temperature gradient risk x1 x1 x xCritical temperature of material to be stored -130°C x1 x1 x xAuto�ll and monitoring required x x x not applicable

No auto�ll and monitoring required x xStorage of more than 6000 2ml vials x x x xStorage of less than 6000 2ml vials xStorage e�ciency x x x xEase of handling racks x xUsage of ln2 low moderate low moderate none

No special requirements needed in storage room xx1 this is only o�ered when the ln2 level in the tank is kept high at all times

Select your Cryopreservation solution

You make lifeWe make life easier

Research Instruments Ltd, Bickland Industrial Park, Falmouth, Cornwall, UK, TR11 4TATel: 01326 372 753 Fax: 01326 378 783email: [email protected] or [email protected]: www.riuk.co.uk