ID Depth δ 13 C Carbo n Nitroge n δ 13 C Depth: (cm) (‰) (%) (%) (‰) (cm) Gr. 3- 5A 5 - 24.7 0 1.62% 0.17% -24.70 -5 Gr. 3- 15 15 - 24.1 4 1.02% 0.12% -24.14 -15 Gr. 3- 25 25 - 24.0 5 0.71% 0.09% -24.05 -25 Gr. 3- 45 45 - 23.7 1 0.38% 0.05% -23.71 -45 Gr. 3- 55 55 - 23.6 0 0.32% 0.05% -23.60 -55 Gr. 3- 61 61 - 23.4 7 0.37% 0.05% -23.47 -61 Gr. 3- 70 70 - 23.4 3 0.39% 0.06% -23.43 -70 Gr. 3- 85 85 - 24.2 8 0.34% 0.05% -24.28 -85 -25.0 -24.5 -24.0 -23.5 -23.0 -180 -160 -140 -120 -100 -80 -60 -40 -20 0 δ 13C (‰ vs.VPDB) Depth (cm) Cross Country Field – Core 3 Profile ? Class Data:

Upload: mauli

Post on 22-Feb-2016

52 views

Category:

Documents


0 download

DESCRIPTION

Class Data:. Cross Country Field – Core 3 Profile. ?. Inductively Coupled Plasma -  Optical Emission Spectrometer (ICP-OES). ICP-OES has been widely used since the 1970's. . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Cross Country Field – Core 3 Profile

ID Depth δ13C Carbon Nitrogen δ13C Depth:(cm) (‰) (%) (%) (‰) (cm)

Gr. 3-5A 5 -24.70 1.62% 0.17% -24.70 -5Gr. 3-15 15 -24.14 1.02% 0.12% -24.14 -15Gr. 3-25 25 -24.05 0.71% 0.09% -24.05 -25Gr. 3-45 45 -23.71 0.38% 0.05% -23.71 -45Gr. 3-55 55 -23.60 0.32% 0.05% -23.60 -55Gr. 3-61 61 -23.47 0.37% 0.05% -23.47 -61Gr. 3-70 70 -23.43 0.39% 0.06% -23.43 -70Gr. 3-85 85 -24.28 0.34% 0.05% -24.28 -85Gr. 3-92 92 -23.98 0.22% 0.03% -23.98 -92Gr. 3-100 100 -24.30 0.23% 0.04% -24.30 -100Gr. 3-110 110 -24.31 0.14% 0.03% -24.31 -110Gr. 3-120 120 -24.79 0.10% 0.03% -24.79 -120Gr. 3-135 135 -24.54 0.11% 0.03% -24.54 -135Gr. 3-145 145 -24.53 0.11% 0.03% -24.53 -145Gr. 3-159 159 -24.85 0.11% 0.03% -24.85 -159

mean -24.18st dev 0.47

-25.0 -24.5 -24.0 -23.5 -23.0

-180

-160

-140

-120

-100

-80

-60

-40

-20

0

δ 13C (‰ vs.VPDB)

Dept

h (c

m)

Cross Country Field – Core 3 Profile

?

Class Data:

Page 2: Cross Country Field – Core 3 Profile

Inductively Coupled Plasma - Optical Emission Spectrometer (ICP-OES)

Page 3: Cross Country Field – Core 3 Profile

ICP-OES has been widely used since the 1970's.

Page 4: Cross Country Field – Core 3 Profile

Inductive Coupled Plasma consist of three concentric quartz tubes in which streams of argon flow. Ionization of the argon is initiated by a spark from a Tesla coil. The geometries of CP source, in radial geometry or axial geometry

Plasma is the phase of matter with its electrons stripped. In argon plasma, argon ions and electrons act as the conducting species. Three power sources are dc-electric, radio and microwave frequency generators. The most advantageous is the radio or inductively coupled plasma (ICP) because of sensitivity and minimal interference. DC plasma source (DCP) are also advantageous and is also simple and less expensive.

Instrument Description and TheoryICP technology was built upon the same principles used in atomic emission spectrometry. Samples are decomposed to neutral elements in a high temperature argon plasma and analyzed based on their mass to charge ratios. An ICP-MS can be thought of as four main processes, including sample introduction and aerosol generation, ionization by an argon plasma source, mass discrimination, and the detection system. The schematic below illustrates this sequence of processes.

Page 5: Cross Country Field – Core 3 Profile

Figure 2. The interface region of an ICP-MS.(Figure reproduced with permission from PerkinElmer, Inc.)

Figure 3. Schematic of quadrupole mass filter.(Figure reproduced with permission from PerkinElmer, Inc.)

              Figure 1. The ICP Torch showing the fate of the sample.(Figure reproduced with permission from PerkinElmer, Inc.)

Inductively coupled plasma mass spectroscopy (ICP-MS) was developed in the late 1980's to combine the easy sample introduction and quick analysis of ICP technology with the accurate and low detection limits of a mass spectrometer.

The resulting instrument is capable of trace multielement analysis,often at the part per trillion level. ICP-MS has been used widely over the years, finding applications in a number of different fields including drinking water, wastewater, natural water systems/hydrogeology, geology and soil science,mining/metallurgy, food sciences, and medicine.

sample introduction

analysis

Page 6: Cross Country Field – Core 3 Profile

              Figure 1. The ICP Torch showing the fate of the sample.(Figure reproduced with permission from PerkinElmer, Inc.)

An ICP-MS combines a high-temperature ICP (Inductively Coupled Plasma) source with a mass spectrometer.

The most important things to remember about the argon ICP plasma are:•The argon discharge, with a temperature of around 6000-10000°K, is an excellent ion source.

•The ions formed by the ICP discharge are typically positive ions, M+ or M+², therefore, elements that prefer to form negative ions, such as Cl, I, F, etc., are very difficult to determine via ICP-MS.

•The detection capabilities of the technique can vary with the sample introduction technique used, as different techniques will allow differing amounts of sample to reach the ICP plasma. •Detection capabilities will vary with the sample matrix, which may affect the degree of ionization that will occur in the plasma or allow the formation of species that may interfere with the analyte determination.

Page 7: Cross Country Field – Core 3 Profile

•Water samples are typically analyzed without sample preparation if they have been filtered and acidified during collection.

•Sediment, soil and rock samples for total elemental analysis are digested using a 4-acid digestion procedure in order to dissolve most silicate minerals. This digestion is carried out in open vessels on a hot-plate, so if volatile elements are of interest, another digestion procedure such as microwave digestion should be used.

•Geological samples for rare-earth-element (REE) analysis are typically prepared using a sodium peroxide sinter method. In this method the ground sample is mixed with sodium peroxide in a carbon crucible and placed in a muffle furnace. The resulting sinter is leached with water and acidified with nitric acid before analysis.

•Biological and organic samples are generally digested using a closed-vessel microwave digestion procedure that is appropriate to the matrix of the sample. This is also the best method for digesting organic samples, including crude oils.

•Speciation Analysis is performed on a variety of sample types using High Performance Liquid Chromatography (HPLC) to separate different chemical forms of an element followed by ICP-MS detection. Sample collection, storage, and pretreatment steps are highly specialized.

What can be analyzed?

Page 8: Cross Country Field – Core 3 Profile

http://www.seaes.manchester.ac.uk/research/facilities/agu/equipment/ICP_MS/moreinfo/

Photographs of argon plasma in operation & ICP torch body.

Cyclonic nebulizer in front of torch body.

Schematic of ICP-MS main processes.

nebulizer

torch

detector

Page 9: Cross Country Field – Core 3 Profile

ElementWavelength

(nm)

EstimatedDetection

Limit (µg/L)Aluminum 308.215 45Antimony 206.833 32

Arsenic 193.696 53Barium 455.403 2

Beryllium 313.042 0.3Boron 249.773 5

Cadmium 226.502 4Calcium 317.933 10

Chromium 267.716 7Cobalt 228.616 7Copper 324.754 6

Iron 259.940 7Lead 220.353 42

Magnesium 279.079 30Manganese 257.610 2

Molybdenum 202.030 8Nickel 231.604 15

Potassium 766.491 variableSelenium 196.026 75

Silicon 288.158 58Silver 328.068 7

Sodium 588.995 29Thallium 190.864 40

Vanadium 292.402 8Zinc 213.856 2

Table 1. Recommended wavelengths and estimated instrumental

detection limits

• The wavelengths listed are recommended because of their sensitivity and overall acceptance.

• Other wavelengths may be substituted if they can provide the needed sensitivity and are treated with the same corrective techniques for spectral interference.

Page 10: Cross Country Field – Core 3 Profile

Strengths• Up to 70 elements can be determined simultaneously in a single analysis.• The useful working range is over several orders of magnitude.• Instrumentation is suitable to automation.

Limitations• The emission spectra are complex and inter-element interferences are

possible if the wavelength of the element of interest is very close to that of another element.

• During Mass Spectrometry, the common matrix elements and other molecular species can interfere with the measurement of some elements. Doubly charged or molecular ionic species can create difficulties in quantifications.

• The sample to be analyzed must be digested prior to analysis in order to dissolve the element(s) of interest.

Inductively Coupled Plasma - (ICP)

Page 11: Cross Country Field – Core 3 Profile

GraphiteFurnace

2400 oC

Graphite Furnace Atomic Absorption Spec.

(GFAA)