NVLAP Lab Code 500089-0 Test Report Number: PL05798-001A RESTL-R010 Rev E Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Page 1 of 13 Report Number: PL05798-001A Model: PWY-EDG-5M-xx-02-E-UL-350-40K / BXBPx518E-UH7 Date: 04/06/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann Cree, Inc 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, Test Engineer Robert Higley, LC, Photometric Test Engineer

Upload: others

Post on 31-Jan-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 1 of 13

    Report Number: PL05798-001A

    Model: PWY-EDG-5M-xx-02-E-UL-350-40K /

    BXBPx518E-UH7

    Date: 04/06/2015

    Cree Racine Engineering Services Testing Laboratory

    (RESTL) Photometric Testing and Evaluation

    Report

    Prepared For:

    Tammy Lehrmann

    Cree, Inc

    9201 Washington Avenue

    Racine, WI 53406

    Prepared By: Approved By:

    Linjie Li, Test Engineer Robert Higley, LC, Photometric Test Engineer

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 2 of 13

    Product Information

    Manufacturer CREE

    Model Number (SKU) PWY-EDG-5M-xx-02-E-UL-350-40K / BXBPx518E-UH7

    Serial Number PL05798-001A

    LED Type XP-G2

    Product Description

    Fabricated gray painted metal top trim/heatsink, eighteen LEDs mounted around perimeter of a cast gray painted metal plate, cast gray painted metal circuit board retaining ring, one clear non-integral plastic lens below each LED. Cast gray painted metal lower housing cap with three vertical supports.

    Driver Information (Where Applicable)

    Cree LED25W-36-C0700

    Length Width Height

    11.00” 9.00” 7.00”

    Sample

    The following sample was submitted for evaluation

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 3 of 13

    Key Photometric Data Sphere Output Goniophotometer

    Luminous Flux 1777.6 1779.5 lm

    Efficacy 83.03 83.51 lm/W

    Correlated Color Temperature (CCT) 3932 K

    Color Rendering Index (CRI) 73

    R9 -18

    Duv 0.00519233

    S/P Ratio* 1.48

    Sphere Goniophotometer

    Electrical Measurements 120V 277V 120V 277V

    Input Wattage 21.41 22.02 21.31 22.01 W

    Input Current 0.18 0.09 0.18 0.09 A

    Input Voltage 120.09 276.99 120.05 277.06 V

    Power Factor 0.986 0.841 0.987 0.845

    Off-State Power 0 0 0 0 W

    Total Harmonic Distortion (Voltage) 0.04 0.04 0.10 0.05 %

    Total Harmonic Distortion (Amperage) 13.37 12.55 13.25 12.50 %

    Note: All photometric measurements taken at 120VAC.

    Luminous Intensity Distribution Goniophotometer

    Max Candela 655.5 Cd

    Angle of Max Candela (Horizontal) 60 ˚

    Angle of Max Candela (Vertical) 60 ˚

    Key Test Parameters Sphere Output Goniophotometer

    Stabilization Time 38 48 min

    Total Operating Time (Stabilization + Test) 43 70 min

    Ambient Temperature 24.6 24.8 ˚C

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 4 of 13

    Chromaticity Coordinates

    x y u v u’ v’ Duv

    0.3874 0.3924 0.2235 0.3396 0.2235 0.5093 0.00519233

    Color Rendering Index Details

    Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

    73 71 77 83 74 70 69 82 58 -18 47 71 42 71 90

    Chromaticity Diagram

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 5 of 13

    Spectral Distribution

    λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

    360 0.000083 530 0.024063 700 0.003891

    370 0.000082 540 0.025941 710 0.002926

    380 0.000036 550 0.027108 720 0.002193

    390 0.000011 560 0.028207 730 0.001631

    400 0.000010 570 0.029337 740 0.001191

    410 0.000333 580 0.030149 750 0.000878

    420 0.002415 590 0.030286 760 0.000650

    430 0.009658 600 0.029279 770 0.000493

    440 0.026017 610 0.027360 780 0.000358

    450 0.027292 620 0.024557 790 0.000265

    460 0.009891 630 0.021313 800 0.000190

    470 0.004800 640 0.017800 810 0.000143

    480 0.003590 650 0.014467 820 0.000095

    490 0.004689 660 0.011527 830 0.000065

    500 0.009123 670 0.008921

    510 0.015269 680 0.006821

    520 0.020627 690 0.005181

    Dominant Wavelength 576 nm

    Peak Wavelength 445 nm

    Spectral Power Distribution (W/nm)

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 6 of 13

    Zonal Lumen Summary

    Zone Lumens % of Total Zone Lumens % of Total

    0-5 3.3 0.2% 90-95 6.8 0.4%

    5-10 9.8 0.6% 95-100 5.8 0.3%

    10-15 15.2 0.9% 100-105 5.0 0.3%

    15-20 22.5 1.3% 105-110 4.3 0.2%

    20-25 32.9 1.9% 110-115 3.7 0.2%

    25-30 44.4 2.5% 115-120 3.1 0.2%

    30-35 55.8 3.1% 120-125 2.6 0.1%

    35-40 66.4 3.7% 125-130 2.1 0.1%

    40-45 84.1 4.7% 130-135 1.5 0.1%

    45-50 128.3 7.2% 135-140 0.8 0.0%

    50-55 183.7 10.3% 140-145 0.3 0.0%

    55-60 217.4 12.2% 145-150 0.0 0.0%

    60-65 250.6 14.1% 150-155 0.0 0.0%

    65-70 260.0 14.6% 155-160 0.0 0.0%

    70-75 210.8 11.8% 160-165 0.0 0.0%

    75-80 116.3 6.5% 165-170 0.0 0.0%

    80-85 33.2 1.9% 170-175 0.0 0.0%

    85-90 8.7 0.5% 175-180 0.0 0.0%

    Total 1779.5 lm 100%

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 7 of 13

    Candela Plot Illuminance Plot

    Roadway Utilization Roadway Summary Lumens % Lamp

    Cutoff Classification CUTOFF

    Distribution TYPE IV, SHORT

    Downward Street Side 939.1 52.8%

    Downward House Side 804.2 45.2%

    Downward Total 1,743.3 98%

    Upward Street Side 16.9 1%

    Upward House Side 19.1 1.1%

    Upward Total 36.1 2%

    Total Lumens 1,779.4 100%

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 8 of 13

    Luminaire Classification System

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 9 of 13

    Candela Tabulations

    0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

    0 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140 140

    2.5 140 140 140 140 140 140 140 139 140 140 140 140 140 139 139 139 139 139 140 140 140 139 139 139 139 139 139 139 139 140

    5 141 141 140 140 140 140 140 140 140 141 141 140 140 140 140 139 139 139 140 140 139 139 139 139 139 138 138 138 138 139

    7.5 144 144 143 142 143 141 138 141 141 141 141 141 140 140 140 140 139 139 138 136 138 139 138 137 138 137 137 138 138 138

    10 143 140 138 135 136 144 136 137 139 142 141 141 140 140 137 135 134 134 132 130 135 133 128 126 126 128 120 124 131 122

    12.5 125 126 131 131 133 130 128 125 126 127 129 131 130 130 130 130 130 130 133 136 134 128 129 126 126 121 119 115 113 117

    15 135 141 132 137 134 128 128 126 126 126 128 131 130 128 128 128 131 133 137 140 138 133 131 124 125 121 116 110 109 117

    17.5 156 153 147 146 146 138 142 137 136 136 136 136 137 138 138 138 138 137 138 138 141 140 138 132 128 123 120 116 115 118

    20 171 172 156 164 164 155 152 149 150 150 150 149 148 147 147 148 149 150 149 148 145 144 145 144 132 131 131 122 119 117

    22.5 171 187 181 183 181 172 160 159 159 160 161 163 162 162 161 160 162 165 163 162 154 150 154 153 144 141 137 128 122 124

    25 198 195 192 194 194 178 175 174 173 173 172 171 170 169 172 174 175 175 176 177 168 161 156 156 149 148 142 131 130 131

    27.5 207 207 198 203 196 191 187 186 186 185 184 184 182 180 179 178 181 185 187 189 176 175 164 166 157 157 144 140 139 140

    30 206 218 214 213 198 200 197 197 196 196 195 194 192 191 189 188 186 185 189 192 185 185 174 176 167 162 149 149 148 150

    32.5 208 228 221 208 205 208 205 204 204 203 202 201 200 198 197 195 194 192 192 191 188 192 179 181 174 164 157 158 157 158

    35 214 234 221 208 204 213 211 210 210 210 209 208 206 205 203 201 200 199 197 195 190 194 188 185 179 164 164 164 164 165

    37.5 218 234 230 215 212 218 215 215 215 214 213 212 210 209 207 206 204 202 201 199 188 198 192 187 180 168 168 170 170 171

    40 226 235 231 222 218 224 224 246 234 221 220 218 217 216 221 226 217 209 207 205 193 197 192 193 182 174 174 176 176 200

    42.5 241 242 235 242 248 256 267 266 262 258 248 239 246 253 251 248 242 236 229 223 212 201 195 189 181 189 196 203 210 216

    45 259 250 261 284 295 304 313 304 304 304 304 304 297 290 287 284 279 274 268 263 247 220 216 204 201 222 229 237 246 248

    47.5 338 317 319 340 381 383 374 386 375 365 372 380 372 364 354 344 348 351 334 316 299 272 262 258 245 266 299 302 296 318

    50 389 388 374 400 450 453 438 454 442 431 444 456 446 437 419 401 409 417 398 379 353 315 321 317 286 314 356 364 350 374

    52.5 404 444 410 448 502 518 494 512 503 494 504 514 505 496 476 455 463 470 452 435 401 355 370 366 323 357 405 422 406 431

    55 419 463 443 485 530 545 522 543 535 527 536 545 535 525 507 488 492 496 479 463 446 391 406 390 358 391 438 447 441 467

    57.5 436 467 466 507 542 554 531 558 547 536 545 554 542 530 517 503 499 495 478 460 471 406 406 388 371 410 445 452 447 481

    60 515 476 487 552 567 574 557 590 571 553 563 574 559 544 531 518 512 507 490 473 491 420 398 395 380 441 452 455 451 490

    62.5 566 492 524 577 584 597 592 633 609 584 603 622 601 580 571 562 558 554 534 514 531 465 423 412 417 473 489 485 483 532

    65 563 461 514 578 588 608 610 656 639 623 636 648 624 600 596 592 588 584 562 540 564 487 425 418 456 513 550 537 548 597

    67.5 522 422 487 534 553 567 585 625 616 606 613 620 596 573 577 580 572 563 540 516 526 462 394 402 469 509 562 540 564 601

    70 443 388 423 456 492 503 530 572 559 547 554 561 535 508 523 538 523 507 495 482 459 410 371 379 430 468 521 511 534 566

    72.5 350 352 367 394 420 424 454 489 477 464 471 478 454 431 451 472 457 441 443 445 386 340 330 352 368 396 447 450 468 496

    75 268 288 279 292 344 334 360 382 375 369 371 373 358 343 358 373 362 352 354 357 306 280 279 287 296 311 350 358 374 389

    77.5 168 188 195 189 225 224 240 248 246 244 239 235 236 237 243 248 241 233 234 235 197 190 182 185 203 205 228 245 254 254

    80 80 100 101 102 124 121 131 131 132 132 129 125 127 128 130 132 132 131 124 118 102 103 97 96 108 112 127 136 139 134

    82.5 41 48 50 56 56 58 60 61 61 61 60 59 59 59 60 60 60 59 55 52 51 49 45 44 50 58 59 63 63 62

    85 19 19 20 19 20 21 21 22 22 22 22 22 22 21 21 21 20 19 18 16 18 19 18 18 19 19 20 21 21 20

    87.5 15 15 15 14 14 15 16 16 16 16 16 15 15 15 15 15 14 13 12 12 14 15 15 15 16 15 15 16 17 16

    90 14 14 14 13 12 13 14 14 14 14 14 14 13 13 13 13 12 11 11 10 13 14 14 14 15 14 13 15 15 15

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 10 of 13

    Candela Tabulations (Continued)

    0 5 15 25 35 45 55 60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 95 105 115 125 135 145 155 165 175 180

    92.5 13 13 13 12 11 12 12 12 12 12 12 12 12 12 12 12 11 10 10 10 12 13 13 13 14 13 12 14 14 13

    95 12 12 12 12 10 10 11 11 11 11 11 11 11 11 11 11 10 9 9 9 12 12 13 13 13 13 10 12 12 12

    97.5 12 12 12 11 9 9 10 10 10 10 10 10 10 10 10 9 9 8 9 9 11 12 12 12 12 12 9 11 11 11

    100 11 11 11 10 8 8 9 9 9 9 9 9 9 9 9 8 8 8 8 9 10 11 12 12 12 11 8 10 10 10

    102.5 11 11 11 10 7 8 8 8 8 8 8 8 8 8 8 8 7 7 8 8 10 11 11 11 11 10 8 9 9 9

    105 10 10 10 9 7 7 8 8 8 8 8 8 8 7 7 7 7 7 7 8 9 10 11 11 10 10 7 8 8 8

    107.5 10 10 10 9 7 7 7 7 7 7 7 7 7 7 7 6 6 6 7 8 8 10 10 10 10 9 7 8 7 7

    110 9 9 9 8 6 6 6 6 6 6 6 6 6 6 6 6 6 6 7 7 8 9 10 10 9 9 7 7 7 7

    112.5 9 9 8 8 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 7 8 9 9 9 9 8 6 6 6 6

    115 8 8 8 7 6 5 5 5 5 5 6 6 6 5 5 5 6 6 6 6 7 8 9 9 8 8 6 6 6 6

    117.5 8 8 8 7 6 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 7 8 8 8 8 7 6 5 5 5

    120 8 7 7 6 5 5 5 5 5 5 5 5 5 5 5 5 5 5 6 6 6 7 8 8 7 7 6 5 5 5

    122.5 7 7 7 6 5 4 4 4 5 5 5 5 5 4 4 5 5 5 5 6 6 7 7 7 7 6 5 5 5 5

    125 6 6 6 6 5 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 6 6 7 7 6 6 5 5 5 5

    127.5 6 6 6 5 5 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 6 6 6 6 5 5 4 4 4

    130 5 5 5 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 4 4 4 4

    132.5 4 4 4 4 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 3 4 4

    135 3 3 3 3 3 3 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

    137.5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

    140 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 1

    142.5 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

    145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

    180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 11 of 13

    Integrating Sphere Equipment List

    Description Manufacturer Model Serial Number

    2M Sphere Everfine 2M 1004156T

    CCD Array Spectrometer Otsuka MC-9801 98010360

    Programmable AC Source Adaptive FC200 2280220

    Power Analyzer Chroma 66202 66202 0005018

    Goniophotometer Equipment List

    Description Manufacturer Model Serial Number

    AC Power Source Elgar CW1251P 1248A02602

    Type C Goniophotometer LSI / UL 6440T 6440PN2028

    Spectroradiometer Gooch & Housego 770VIS/NIR 12415189

    Power Meter Yokogawa WT210 91M945458

    Test Methods Used:

    Title Description

    ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

    CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

    CIE Pub. 15:2004 Colorimetry

    IES LM-58:1994 Spectroradiometric Measurements

    IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

    IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

    Reference Standard Used:

    Equipment Description

    2m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119

    Type C Goniophotometer and Spectrometer

    Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 12 of 13

    Disclaimers:

    This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

    The results contained in this report pertain only to the tested sample.

    This report shall not be reproduced, except in full, without written approval of the CESTL.

    *Items marked with a single asterisk are not covered by the NVLAP accreditation.

    In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

    ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as

    “Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the

    first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are

    performed using a Type C goniophotometer.

    The integrating sphere information in the equipment list, report items marked with **, or results specifically

    identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the

    subcontracted laboratory when subcontracting is indicated on the cover page.

    Additional Comments:

    The photos below are intended to show the orientation and fixturing/set-up of the units under test. These

    are critical to understanding the results of the test given the sensitivity of many products and

    measurement systems to orientation and set-up considerations, and also for reproducing the conditions of

    the test.

    Goniophotometer Integrating Sphere

  • NVLAP Lab Code 500089-0

    Test Report Number: PL05798-001A RESTL-R010 Rev E

    C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

    Page 13 of 13

    Document Revision History:

    Each subsequent revision of this report replaces the preceding report.

    Date Rev DCN # Change at the time of this test By Approval

    4/06/15 A DMS Origination L. Li R. Higley