county of prince williameservice.pwcgov.org/planning/documents/sup2018-00026.pdfattachment b - staff...
TRANSCRIPT
COUNTY OF PRINCE WILLIAM 5 County Complex Court, Prince William, Virginia 22192-9201 PLANNING
(703) 792-7615 FAX (703) 792-4401 OFFICE
Internet www.pwcgov.org
Rebecca Horner, AICP, CZA Director of Planning June 8, 2018
TO: Planning Commission
FROM: Ana Rivera
Planning Office
RE: Special Use Permit SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Gainesville Magisterial District
I. Background is as follows:
A. Request – This is a request to amend a special use permit (SUP) to allow an
approximate 487-square-foot addition to an existing Chick-fil-A restaurant, dual
drive-through lanes with two ordering locations and associated canopy, and signage.
Uses/Features Existing Proposed
Use(s) Restaurant with drive-through Restaurant with dual
drive-through
Gross Floor Area
(GFA)
4,509 sq. ft. restaurant building 4,869 sq. ft. restaurant building
with storage area (includes a
487 sq. ft. building addition and
the removal of 127 sq. ft.)
Drive-through One drive-through lane Dual drive-through lanes with
two ordering points
Uses/Features Required Provided
Open Space 15% ±15%
Parking Spaces 49 49
ADA Spaces 2 2
B. Site Location – The site is located at 10677 Sudley Manor Drive, approximately 700
feet south of the intersection of Sudley Manor Drive and Sudley Road. The SUP site
is identified on County maps as GPIN 7697-30-3786.
C. Comprehensive Plan – The site is designated GC, General Commercial, on the Long
Range Land Use Map.
D. Zoning – The ±1.21 acre site is zoned B-1, General Business, with conditions per
SUP#PLN2007-0046 and SUP#PLN2008-00230.
E. Surrounding Land Use – The site is located within a commercial and office area. To
the north of the site is the Bull Road Commercial Center across Sudley Manor Drive
and a pharmacy across an access road. To the south is a fast food restaurant; and to
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
June 8, 2018
Page 2
the east is an office building, an indoor recreation building, and an access road. The
Bull Road Commercial Center across Sudley Manor Drive is located to the west.
F. Background and Context: - This site was subject of two previous SUPs, which are
summarized as follows:
On December 4, 2007, the Board of County Supervisors (BOCS) approved
SUP#PLN2007-0046, which allowed a fast food restaurant with a drive-through
window on the subject site. The BOCS approved the SUP, subject to the
conditions dated November 8, 2007.
On April 1, 2008, the BOCS approved SUP#PLN2008-00230, which allowed a
façade sign modification for the existing restaurant with a previous SUP for a
drive-through. The BOCS approved the SUP, subject to the conditions dated
February 8, 2008.
If the SUP amendment is approved, it will supersede both previous SUPs.
II. Current Situation is as follows:
A. Planning Office Recommendation - The Planning Office recommends approval of
Special Use Permit SUP2018-00026, Chick-fil-A at Sudley Manor Drive, subject to
conditions dated April 19, 2018, found in Attachment C. Staff recommends approval
for the following reasons:
As conditioned through the SUP, the building elevations, signage details,
enhanced landscaping, and specific use and operational parameters are being
proposed to mitigate the impacts.
The subject site is designated GC, General Commercial, on the Long Range Land
Use Map and is zoned B-1, Business. The proposed facility is planned within an
area that is designated for commercial uses.
B. Planning Commission Public Hearing - A public hearing before the Planning
Commission has been advertised for June 6, 2018.
II. Issues in order of importance are as follows:
A. Comprehensive Plan
1. Long-Range Land Use - Is the proposed use consistent with those uses
intended by the GC, General Commercial, Long Range Land Use designation?
2. Level of Service (LOS) - How does the proposal address the mitigation of
impacts to existing levels of service?
B. Community Input - Have members of the community raised any issues?
C. Other Jurisdictional Comments - Have other jurisdictions raised any issues?
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
June 8, 2018
Page 3
D. Legal Uses of the Property - What uses are allowed on the property? How are legal
issues resulting from the Planning Commission action addressed?
E. Timing - When must the Planning Commission take action on this application?
IV. Alternatives beginning with the staff recommendation are as follows:
A. Recommend approval of Special Use Permit SUP2018-00026, Chick-fil-A at Sudley
Manor Drive, subject to conditions dated April 19, 2018, found in Attachment C.
1. Comprehensive Plan Consistency Analysis:
a) Long-Range Land Use - The site is designated GC, General
Commercial, on the Long Range Land Use Map. The existing zoning
B-1 implements the GC planning designation.
b) Level of Service (LOS) - The LOS for the ±487-square-foot building
expansion will be mitigated as follows:
Fire & Rescue $0.61 per SF 487 sq. ft. $297.07
TOTAL $297.07
2. Community Input - Notice of the application has been transmitted to adjacent
property owners within 500 feet. As of the date of this report, the Planning
Office has not received any input from the community.
3. Other Jurisdictional Comments - The project is outside the required
notification area of nearby jurisdictions.
4. Legal Uses of the Property - If the SUP is approved, ±487-square-foot
addition to an existing Chick-fil-A restaurant, dual drive-through lanes with
two ordering locations and associated canopy, and signage, could be
constructed on the site subject to the proposed conditions. Legal issues
resulting from Planning Commission’s action are appropriately addressed by
the County Attorney’s Office.
5. Timing - The Planning Commission has until September 18, 2018, 90 days
from the first public hearing date, to take action on this proposal. Approval of
the special use permit would meet the 90-day requirement.
B. Recommend denial of Special Use Permit SUP2018-00026, Chick-fil-A at Sudley
Manor Drive.
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
June 8, 2018
Page 4
1. Comprehensive Plan
a) Long-Range Land Use - If the application is denied, the land use
designation of the site would remain GC, General Commercial, on the
Long Range Land Use Map, and the zoning classification would
remain B-1, General Business.
b) Level of Service - Denial would not have any impact on the existing
level of service.
2. Community Input - Notice of the application has been transmitted to adjacent
property owners within 500 feet. As of the date of this report, the Planning
Office has not received any input from the community.
3. Other Jurisdictional Comments - The project is outside the required
notification area of nearby jurisdictions.
4. Legal Uses of the Property - If the SUP application is denied, a second drive-
through lane could not be constructed on the site. Legal issues resulting from
Planning Commission’s action are appropriately addressed by the County
Attorney’s Office.
5. Timing - The Planning Commission has until September 18, 2018, 90 days
from the first public hearing date, to take action on this proposal. Approval of
the special use permit would meet the 90-day requirement.
V. Recommendation is that the Planning Commission accept Alternative A and recommend
approval of Special Use Permit SUP2018-00026, Chick-fil-A at Sudley Manor Drive, subject
to conditions dated April 19, 2018.
Staff: Ana Rivera, x 7128
Attachments
A. Area Maps
B. Staff Analysis
C. Proposed Conditions
D. Special Use Permit Plan
E. Canopy Details
F. Signage
G. Historical Commission Resolution
Attachment A – Maps
VICINITY MAP
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page A-1
Attachment A – Maps
AERIAL MAP
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page A-2
Attachment A – Maps
EXISTING ZONING MAP
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page A-3
Attachment A – Maps
LONG-RANGE LAND USE MAP
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page A-4
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-1
Part I. Summary of Comprehensive Plan Consistency
Staff Recommendation: Approval
This analysis is based on the relevant Comprehensive Plan action strategies, goals, and policies. A
complete analysis is provided in Part II of this report.
Comprehensive Plan Sections Plan Consistency
Long-Range Land Use Yes
Community Design Yes
Cultural Resources Yes
Economic Development Yes
Environment Yes
Fire and Rescue Yes
Police Yes
Potable Water Yes
Sanitary Sewer Yes
Transportation Yes
Part II. Comprehensive Plan Consistency Analysis
The following table summarizes the area characteristics (see maps in Attachment A):
Direction Land Use Long Range Future Land
Use Map Designation Zoning
North
Bull Road Commercial Center
across Sudley Manor Drive and
pharmacy across access road.
REC, GC B-1
South Fast food restaurant. GC B-1
East Office building and indoor
recreation and access road. GC O(H)
West Bull Road Commercial Center
across Sudley Manor Drive. REC, GC B-1
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-2
Long-Range Land Use Plan Analysis
Through wise land use planning, the County ensures that landowners are provided a reasonable use
of their land while the County is able to judiciously use its resources to provide the services for
residents and employers’ needs. The Long Range Land Use Plan sets out policies and action
strategies that further the County’s goal of concentrating population, jobs, and infrastructure within
vibrant, walkable, mixed-use centers serviced by transit. In addition to delineating land uses on the
Long Range Land Use Map, the plan includes smart growth principles that promote a countywide
pattern of land use that encourages fiscally sound development and achieves a high-quality living
environment; promotes distinct centers of commerce and centers of community; complements and
respects our cultural and natural resources, and preserves historic landscapes and site-specific
cultural resources; provides adequate recreational, park, open space and trail amenities that
contribute to a high quality of life for County residents; and revitalizes, protects, and preserves
existing neighborhoods.
This site is located within the Development Area of the County, and is classified GC, General
Commercial, on the Long Range Land Use Map within the Comprehensive Plan. The following
table summarizes the uses and densities intended within the GC designation:
Long Range Land
Use Map Designation Intended Uses and Densities
General Commercial
(GC)
The purpose of the General Commercial classification is to recognize
areas of existing commercial activity along major County roadways
that serve a local market rather than a regional market. Access to GC
uses shall be limited to abutting arterial or collector roadways, rather
than from lesser abutting roadways, except where interparcel
connections are provided between abutting GC sites. Pedestrian access
to adjacent and nearby residential areas where appropriate shall be
encouraged. Primary uses in the GC are retail, retail service, and
lodging uses. Office use shall be considered a secondary use and shall
represent no greater than 25 percent of the total GC gross floor area of
the project. Infill and redevelopment of areas identified as GC are
encouraged, particularly with new or relocated commercial uses that
are of a scale similar to surrounding uses. Designation of new GC areas
is discouraged. Office development in GC areas is encouraged to be in
accordance with the Illustrative Guidelines for Office Development,
provided as a supplement to the Community Design Plan chapter of
the Comprehensive Plan and available from the Planning Office.
Office buildings in GC areas are preferred at a height of at least 2-3
stories.
This is a request to allow a ±487-square-foot addition to an existing Chick-fil-A restaurant, dual
drive-through lanes with two ordering locations, a canopy, and sign modifications. Technically,
this is an amendment of SUP#PLN2007-00461 and SUP #PLN2008-00230. If approved, the SUP
amendment will supersede the previously approved SUPs.
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-3
Proposal’s Strengths
Land Use Consistency – The proposed use will be consistent with the surrounding retail uses.
The existing restaurant is the type of service retail that is compatible with the GC, General
Commercial, designation which recommends retail and retail service uses. This use is permitted
by-right in the B-1, General Business and drive-through facilities are allowed with a SUP in this
zoning district. This SUP is proposed to allow a second drive-through lane, whereas one lane
has been previously approved.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the Long-
Range Land Use Plan.
Community Design Plan Analysis
An attractive, well-designed County will attract quality development, instill civic pride, improve the
visual character of the community and create a strong, positive image of Prince William County.
The Community Design Plan sets out policies and action strategies that further the County’s goals
of providing quality development and a quality living environment for residents, businesses and
visitors, and creating livable and attractive communities. The plan includes recommendations
relating to building design, site layout, circulation, signage, access to transit, landscaping and
streetscaping, community open spaces, natural and cultural amenities, stormwater management, and
the preservation of environmental features.
Proposal’s Strengths
Building Orientation - The building front is oriented towards Sudley Manor Drive and the drive-
through will be along of the side and rear where it will be less visible from the roadway.
Interparcel Access - There is interparcel access to the site through the adjoining Walgreens and
Starbucks sites.
Architecture - The proposed building addition will remain in substantial conformance with the
previously approved elevations. The design incorporates consistent materials such as brick and
stone compatible with the existing building.
Retaining wall – Minor changes in the parking area will require the construction of a 4’ tall
retaining wall. The design, materials and colors for the retaining wall will be compatible with
those used in the existing restaurant building.
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-4
Canopy Elevations - The Applicant has provided detailed canopy elevations. The design of the
canopy and supports will be compatible with the building architecture.
Pedestrian Connections - A pedestrian access to the restaurant exists along Sudley Manor Drive
on the north side of the site. The existing access will not be impacted by the additional drive-
through lane. Pedestrian connectivity is encouraged by the Comprehensive Plan.
Location of Loading Space and Refuse Storage Area - The refuse storage area and loading area
are located to the back side of the site, where it will be less visible. The plan shows landscaping
and dumpster enclosure for screening.
Signage - The signage for the proposed use will be in compliance with the Zoning Ordinance
and DCSM as conditioned. No freestanding signage will be located within the SUP area.
Landscaping - The Applicant has provided a landscape plan, dated April 24, 2018, which
illustrates how the loss of landscaping due to parking space relocation will be supplemented on
site.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the
Community Design Plan.
Cultural Resources Plan Analysis
Prince William County promotes the identification, evaluation, and protection of cultural resource
sites throughout the County, as well as the tourism opportunities these sites present. The Cultural
Resources Plan recommends identifying, preserving, and protecting Prince William County’s
significant historical, archaeological, architectural, and other cultural resources—including those
significant to the County’s minority communities—for the benefit of all of the County’s citizens
and visitors. To facilitate the identification and protection of known significant properties that have
cultural resource values worthy of preservation, the land use classification County Registered
Historic Site (CRHS) is used in the Comprehensive Plan. The plan includes areas of potentially
significant known but ill-defined or suspected pre-historic sites, Civil War sites, historic viewsheds,
landscapes or areas of potential impact to important historic sites, and encourages the identification,
preservation, protection, and maintenance of all cemeteries and/or gravesites located within the
County.
The property does not appear on the Historic Sensitivity Area or other cultural resource inventories.
The subject site has been previously disturbed and is developed with an existing commercial
building and paved surfaces within a shopping center area. The site has no potential for
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-5
archaeological resources and no additional review is necessary. This proposal went before the
Historical Commission on March 13, 2018, and no further work was recommended.
Proposal’s Strengths
Cultural Resources - There are no known cultural resources located on the subject site. The
proposed use will have no impact on cultural resources.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the Cultural
Resources Plan.
Economic Development
An enhanced, diverse nonresidential tax base creates quality jobs, allowing people to live, work and
recreate in Prince William County. The Economic Development Plan sets out policies and action
strategies that further the County’s goal of attracting and fostering the growth of environmentally
sound industries to create quality jobs and diversify the nonresidential tax base, creating a climate
where citizens can live and work in Prince William County. The plan includes recommendations
relating to business attraction, retention and expansion, the provision of adequate infrastructure,
redevelopment of less competitive areas, telecommuting and other information-age opportunities,
and recognition of tourism as an industry.
Proposal’s Strengths
Non-Residential Development - Commercial space on the subject site enhances the County’s
nonresidential tax base. This is consistent with the Prince William County Strategic Plan 2017-
2020.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the
Economic Development Plan.
Environment Plan Analysis
Prince William County has a diverse natural environment, extending from sea level to mountain
crest. Sound environmental protection strategies will allow the natural environment to co-exist with
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-6
a vibrant, growing economy. The Environment Plan sets out policies and action strategies that
further the County’s goal of preserving, protecting and enhancing significant environmental
resources and features. The plan includes recommendations relating to the incorporation of
environmentally sensitive development techniques, improvement of air quality, identification of
problematic soil issues, preservation of native vegetation, enhancement of surface and groundwater
quality, limitations on impervious surfaces, and the protection of significant viewsheds.
An Environmental Constraints Analysis (ECA) was not required with this SUP application because
the site has already been impacted with the existing restaurant. Only a small portion of the site is
located within a Resource Protection Area (RPA) and there are no mapped streams on the subject
site.
The site is located in Subwatershed #166, which drains into Lake Linden and into the Bull Run
watershed. The subject site is fully developed and no new land disturbance is being proposed.
Proposal’s Strengths
Landscaping - The site will be landscaped with a mix of drought-resistant, indigenous
evergreen, deciduous and ornamental trees and shrubs in the quantities and locations shown on
the landscape plan, and as conditioned.
Stormwater Management Facilities - The Applicant intends to use an off-site regional
stormwater facility to the north of the site across Sudley Manor Drive adjacent to the Festival at
Bull Run shopping center. If off-site facilities do not meet stormwater management
requirements, the Applicant is conditioned to provide on-site underground facilities.
Proposal’s Weaknesses
Impervious Surfaces - The development proposes an increase in paving areas to accommodate
the second drive-through lane.
On balance, this application is found to be consistent with the relevant components of the
Environment Plan.
Fire and Rescue Plan Analysis
Quality fire and rescue services provide a measure of security and safety that both residents and
businesses have come to expect from the County. The Fire and Rescue Plan sets out policies and
action strategies that further the County’s goal of protecting lives, property, and the environment
through timely, professional, humanitarian services essential to the health, safety, and well-being of
the community. The plan includes recommendations relating to siting criteria, appropriate levels of
service, and land use compatibility for fire and rescue facilities. The plan also includes
recommendations to supplement response time and reduce risk of injury or death to County
residents, establishment of educational programs, such as cardio-pulmonary resuscitation (CPR)
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-7
training, automatic external defibrillators (AED), and encourage installation of additional fire
protection systems—such as sprinklers, smoke detectors, and other architectural modifications.
The site is closest to the Stonewall Jackson Fire and Rescue Station 11. It is estimated that the
travel time would be within the recommended four minute travel time; however, the number of
emergency incidents assigned to the station exceeds their workload capacity.
The development, as proposed, will generate a need for a capital expenditure of $0.61 per square
foot of the new building area. As a result of applying the established LOS standards for fire and
rescue to the subject application, a development condition has been drafted to address this issue.
Proposal’s Strengths
Monetary Contribution - The conditions require a monetary contribution of $0.61 per square
foot of building addition to mitigate impacts on Fire and Rescue services.
4.0 Minute Response Time - The site is within the recommended 4.0-minute travel time for fire
suppression and basic life support.
8.0 Minute Response Time - The site is within the recommended 8.0-minute travel time for
advanced life support.
Proposal’s Weaknesses
Capacity - The nearest station, Stonewall Jackson, is operating over the recommended capacity
of 2,200 incidents for FY 2017.
On balance, this application is found to be consistent with the relevant components of the Fire and
Rescue Plan.
Police Plan Analysis
Residents and businesses expect a high level of police service for their community. This service
increases the sense of safety and protects community investments. The Police Plan is designed to
promote Prince William County’s public safety strategic goal to continue to be a safe community,
reduce criminal activity, and prevent personal injury and loss of life and property, as well as to
ensure effective and timely responses throughout the County. This plan encourages funding and
locating future police facilities to maximize public accessibility and police visibility as well as to
permit effective, timely response to citizen needs and concerns. The plan recommends educational
initiatives, such as Neighborhood and Business Watch, and Crime Prevention through
Environmental Design (CPTED), which encourages new development to be designed in a way that
enhances crime prevention. The plan also encourages effective and reliable public safety
communications linking emergency responders in the field with the Public Safety Communications
Center.
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-8
Proposal’s Strengths
No Significant Impacts - At this time, the Police Department does not believe this application
will create a significant impact on Police calls for service.
Graffiti - The Applicant will notify the Police Department if their property is marked with
graffiti and will remove it promptly thereafter, as conditioned.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the Police
Plan.
Potable Water Plan Analysis
A safe, dependable drinking water source is a reasonable expectation of County residents and
businesses. The Potable Water Plan sets out policies and action strategies that further the County’s
goal of providing an economically and environmentally sound drinking water system. The plan
includes recommendations relating to system expansion, required connections to public water in the
development area, and the use of private wells or public water in the rural area.
The subject property is within the Development Area of the County and is within the Prince
William County Service Authority service area. The existing restaurant is served by public water.
Proposal’s Strengths
Water Connection - Public water service is available on site from an 8-inch water main.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the Potable
Water Plan.
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-9
Sanitary Sewer Plan Analysis
Appropriate wastewater and sanitary facilities provide needed public health and environmental
protections. The Sewer Plan sets out policies and action strategies that further the County’s goal of
providing an economically and environmentally sound sanitary and stormwater sewer system. The
plan includes recommendations relating to system expansion, required connections to public sewer
in the development area, and the use of either private or public sewer systems in locations classified
as Suburban Residential Rural (SRR), as well as the rural area.
The site is located in the Development Area within the Prince William County Service Authority
area. The existing restaurant is served by public sewer.
Proposal’s Strengths
Sewer Connection - The public sewer connection is available on-site from an existing 16-inch
gravity sewer main.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the Sanitary
Sewer Plan.
Transportation Plan Analysis
By providing a multi-modal approach to traffic circulation Prince William County promotes the
safe and efficient movement of goods and people throughout the County and surrounding
jurisdictions. The Transportation Plan sets out policies and action strategies that further the
County’s goal of creating and sustaining an environmentally friendly, multi-modal transportation
system that meets the demands for intra- and inter-county trips, is integrated with existing and
planned development, and provides a network of safe, efficient, and accessible modes of travel.
The plan includes recommendations addressing safety, minimizing conflicts with environmental
and cultural resources, maximizing cost effectiveness, increasing accessibility of all travel modes,
minimizing projected trip demand, and providing sufficient network capacity. Projects should
include strategies that result in a level of service (LOS) of “D” or better on all roadway corridors
and intersections, reduce traffic demand through transportation demand management strategies,
dedicate planned rights-of-way, provide and/or fund transit infrastructure, pedestrian and bicycle
pathways, and improved and coordinated access to transit facilities.
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-10
A traffic impact analysis (TIA) was not required for this application. There is no estimated net
traffic increase for the proposed use. The site has frontage on Sudley Manor Drive and gains shared
vehicular access through the adjoining Walgreens and the Starbucks sites.
Proposal’s Strengths
Level of Service - The proposal will not affect the existing level of service, or adversely affect
visibility along any of the adjoining thoroughfares.
Drive-Through Stacking Spaces - As shown on the SUP plan, the stacking spaces for the drive-
through meet the DCSM requirements.
Drive-through Circulation - The drive-through circulation is one-way in a counter-clockwise
direction.
Sidewalks and Internal Pedestrian Connections - There is an existing sidewalk along Sudley
Manor Drive, and sidewalks around the periphery of the south and west sides of the building
and a crosswalk/sidewalk connecting the two. Pedestrian connectivity is encouraged by the
Comprehensive Plan.
Proposal’s Weaknesses
None identified.
On balance, this application is found to be consistent with the relevant components of the
Transportation Plan.
Strategic Plan
This section of the report is intended to address the project’s alignment with the outcomes provided
within the County’s Strategic Plan. The Strategic Plan posits that individuals, families and
businesses prefer communities with a robust economy; easy access to jobs, services and activities;
that support even the most vulnerable in the community; are safe and secure; and provide a quality
education that assures lifelong learning and steady employment. From this analysis, the Strategic
Plan Team developed five strategic goal areas to guide Board actions: “Robust Economy,”
“Mobility,” “Wellbeing,” “Safe and Secure Community,” and “Quality Education and Workforce
Development.” It is important to note that no single area is viewed as more critical than another.
Rather, each are interrelated and have direct impact on each other. Collectively, these goal areas
impact the quality of life in all facets of the community issues raised during the review of the
proposal, which are not directly related to the policies, goals, or action strategies of the
Comprehensive Plan, but which are materially relevant to the County’s responsibilities in
considering land use issues. The aspects of the proposal relative to the Strategic Plan are as
follows:
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-11
Increase commercial tax base
Increase commercial tax base as a percentage of overall tax revenue to 35%.
Increase at-place employment
Increase growth in at-place employment by more than 3,300 jobs per year.
Materially Relevant Issues
This section of the report is intended to identify issues raised during the review of the proposal,
which are not directly related to the policies, goals, or action strategies of the Comprehensive Plan,
but which are materially relevant to the County’s responsibilities in considering land use issues.
The materially relevant issues in this case are as follows:
None identified.
Minimum Design Criteria
Staff and other agencies that have reviewed the proposal noted the following minimum design
criteria. The development proposal will be reviewed for compliance with all minimum standards at
the time that the Applicant submits detailed site development information prior to the issuance of
permits. The listing of these issues is provided to ensure that these concerns are a part of the
development record. Such issues are more appropriately addressed during the site plan review.
None identified.
Agency Comments
The following agencies have reviewed the proposal and their comments have been summarized in
relevant Comprehensive Plan chapters of this report. Individual comments are in the case file in the
Planning Office:
Building Official
County Archaeologist
Crime Prevention Police
Fire Marshal’s Office
Historical Commission
Land Development Case Manager
Long Range Planning
Planning Case Planner
Planning GIS Specialist
Attachment B - Staff Analysis
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page B-12
Service Authority
Transportation Department
VDOT Fairfax
Watershed Management
Attachment C
Proposed Conditions dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page C-1
Owner: Manassas Crossroads Retail, L.L.C.
Applicant: Chick-fil-A, Inc.
Special Use Permit: SUP #2018-00026, Chick-fil-A at Sudley Manor Drive
Prince William County GPIN 7697-30-3786
Special Use Permit Area: +/-1.21 acres
Magisterial District: Gainesville
Date: April 19, 2018
The following conditions supersede the conditions associated with SUP #PLN2007-00461 and
SUP #PLN2008-00230 and are intended to offset the impacts of the proposal and to render the
application consistent with the applicable chapters of the Comprehensive Plan and the
surrounding areas. If the conditions of this Special Use Permit (SUP) or the Special Use Permit
Plan are in conflict with the Zoning Ordinance, and/or the Design and Construction Standards
Manual (DCSM), the more restrictive standards shall apply, except as specifically allowed by
this special use permit.
The Applicant shall file a site plan within one (1) year of approval of this special use permit by
the Board of County Supervisors and shall have up to five (5) years from the date of final site
plan approval to commence the proposed use. The restaurant with drive through facilities use has
commenced on the Property. Accordingly the one and five year requirements have been
satisfied. Issuance of an occupancy permit constitutes commencement of the use.
1. Site Development - The Applicant shall develop the site in substantial conformance with
these conditions and the special use permit plan entitled “Chick-fil-A Sudley Manor SUP
Plan,” prepared by Bohler Engineering, dated January 30, 2018, last revised April 19,
2018 (sheet 2) (hereinafter, the “SUP Plan”). Minor modifications to the SUP Plan may
be allowed in order to meet applicable regulations and standards necessary to gain final
site plan approval for this development or to coordinate with adjoining developments.
2. Use Parameters
a. Use Limitations - The use shall be limited to a restaurant with a maximum of two
drive-through service lanes as shown on the SUP Plan.
b. Hours of Operation - Hours of operation may be 24-hours per day, seven days per
week.
c. Outdoor Speaker System - This system shall be limited to two speakers to be used
for ordering, and shall not be audible outside of the SUP area.
Attachment C
Proposed Conditions dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page C-2
3. Community Design
a. Architecture - The design of the building including materials and colors shall
remain in substantial conformance with the elevations that appear on the Exterior
Elevations Plans entitled “Chick-Fil-A at Manassas Crossroads” dated April 5,
2007 (hereinafter, the “Illustrative Building Elevations”), and shall be the same or
similar lighter colored brick on the top of the exterior façade walls and darker
colored brick on the bottom of the exterior façade walls to remain consistent with
the other buildings in Manassas Crossroads. The portion of the building labeled
“Proposed Addition” on the SUP Plan shall be compatible with the Illustrative
Building Elevations (i.e., the existing building). Minor modifications from these
elevations may be allowed in order to meet applicable regulations and standards
necessary to coordinate with adjoining developments in terms of colors, materials
and finishes. The Applicant shall submit the architectural construction plan
drawings, two weeks prior to the request for the building permit release letter, for
review and approval of compatibility with the Illustrative Building Elevations by
the Planning Office.
b. Refuse Storage Area - The refuse storage areas shall not be located within any
setback area and shall be screened with a solid masonry enclosure (brick), which
is compatible with the building, and gates that prohibit viewing this area from
adjoining properties and public rights-of-way. The gates shall remain closed
when not in use and the trash containers shall be emptied as necessary to prevent
odors or infestation by vermin.
c. Landscaping - Landscaping, as evidenced on the final site plan, shall be provided
by the Applicant substantially as shown on the landscape plan entitled “Chick-fil-
A Sudley Manor – Landscape Plan,” prepared by Bohler Engineering, dated
January 30, 2018, last revised April 19, 2018 (hereinafter, the “Landscape Plan”),
and shall meet the minimum requirements of the DCSM and the following
standards at the time of planting:
i. Sudley Manor Drive Frontage - The landscaping along Sudley Manor
Drive shall contain the following: a 10-foot wide landscaping strip
containing a minimum of 80 plant units per 100 linear feet of frontage.
The planting strip and planting areas shall not be located in existing or
proposed right-of-way or parallel utility easements unless permitted by the
easement holder.
ii. Deciduous Trees - Deciduous trees shall have a minimum caliper of 2.5
inches as measured 4 feet above grade level. No less than one-third of all
the required tree canopy shall be large and medium deciduous trees.
iii. Evergreen Trees - Plant material shall be a minimum of seven feet in
height.
Attachment C
Proposed Conditions dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page C-3
iv. Evergreen Shrubs - The height of shrubs shall be a minimum of three feet.
v. Drought-Resistant and Indigenous Plantings - All plantings shall be
drought-resistant and indigenous or other species approved at final site
plan.
vi. Utilities - Proposed utility easements shall be located within the parking
lots and travelways to avoid landscape areas with minimal perpendicular
(or near perpendicular-varying up to 10° from 90°) landscape area
crossings, subject to approval at final site plan. Any existing on-site utility
poles shall be removed and all existing and/or proposed utilities such as
power, cable, and telephone shall be placed underground.
d. Signs
i. Sign Package - In accordance with Zoning Ordinance Section 32-250.24,
signage shall be implemented in substantial conformance with the sign
package entitled Illustrative Sign Package #SUP2018-00026, dated April
19, 2018, and the sign location plan entitled “Store Series 06-C Manassas
Crossroads” Sheet 1 by Bohler Engineering dated January 22, 2008,
revised through February 5, 2008 and the conditions herein.
ii. Freestanding Signage - There shall be no freestanding signage (other than
preview/ordering boards and directional signage) on the property.
iii. Maintenance - All façade signs shall be well-maintained at all times. Any
burned out lighting shall be replaced within 48 hours.
iv. Substantive Changes to Signage - Any increase in size and/or quantity of
façade signage at the subject site that is not consistent with the SUP Plan,
sign package and conditions of this special use permit shall require a new
special use permit application.
v. Sign Permits - Sign permits are required for all façade signs. Color, scaled
renderings of all signage shall be submitted in conformance with the
conditions herein as part of the sign permit approval process.
vi. Traffic Signs - Appropriate signs such as “Stop”, “One-Way”, “Do Not
Enter”, and “Yield to Pedestrians” shall be provided for safe vehicular
circulation and pedestrian crossing from the parking lot to the building.
e. Lighting - Freestanding lighting fixtures shall be compatible in terms of the design
and height with the lighting used in the rest of the Manassas Crossroads
development i.e. adjoining sites to the north and south used for Walgreens and
Starbucks. Compliance shall be demonstrated on the approved final site plan. No
neon or spot lighting shall be permitted.
Attachment C
Proposed Conditions dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page C-4
f. Pedestrian Access - A sidewalk and crosswalk as shown on the SUP Plan shall be
provided on the final site plan between the building and the existing sidewalk
along Sudley Manor Drive. If the existing sidewalk along Sudley Manor Drive is
removed due to the addition of (a) turn lane(s), the Applicant shall replace it with
a 5-foot wide sidewalk within the right-of-way.
g. Maintenance of Property
i. Site Maintenance - The Owner/Applicant shall maintain the site and shall
pick up trash, litter, and debris on a daily basis or more frequently as
needed.
ii. Graffiti Removal - Graffiti on the site shall be removed immediately by the
applicant. Graffiti shall be deemed any inscription or marking on walls,
buildings or structures not permitted by sign regulations in Sec. 32-250.21
et seq. of the Zoning Ordinance. Any graffiti is to be reported to the
Prince William County Police Department before removal.
4. Environment
a. Grease Trap - An appropriately sized and designed grease trap shall be provided
on site and shown on the final site plan. The grease trap shall be properly
maintained to prevent grease build-up in the force main or gravity sewer.
b. Stormwater Management - Unless provided off-site, the applicant shall construct
on-site underground stormwater management facilities as determined at final site
plan.
5. Fire and Rescue
a. Monetary Contribution - The Owner/Applicant shall make a $0.61 per square foot
of proposed additional building area (+/- 487 SF) monetary contribution for fire
and rescue services to the Board of County Supervisors prior to, and as a
condition of issuance of the final site plan approval.
6. Transportation
a. Access Points - There shall be no direct vehicular access point from the subject
SUP area to Sudley Manor Drive. Access shall remain as depicted on the SUP
Plan.
b. Loading/Unloading - Deliveries by large tractor trailers shall be prohibited
between the hours of 7:00 a.m. to 9 a.m. and 5:00 p.m. to 7:00 p.m., Monday
through Friday.
Attachment C
Proposed Conditions dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page C-5
7. Connection to Public Water & Sewer - The site shall be connected to public water and
sewer with the applicant bearing all costs associated with providing all on- and off site
facilities necessary to meet the demand generated by the proposed special use.
8. Handicapped Parking and Signage - Parking and signage for handicapped customers shall
be provided by the applicant in accordance with the Design and Construction Standards
Manual and other current standards.
9. Escalator - In the event the monetary contributions set forth in the development
conditions are paid to the Prince William County Board of County Supervisors within
eighteen (18) months of the approval of this special use permit, as applied for by the
Applicant, said contributions shall be in the amounts stated herein. Any monetary
contributions set forth in the development conditions which are paid after eighteen (18)
months following the approval of this special use permit shall be adjusted in accordance
with the Urban Consumer Price Index (CPI-U), published by the United States
Department of Labor, such that at the time contributions are paid they shall be adjusted by
the percentage change in the CPI-U from that date eighteen (18) months after final
approval of this special use permit to the most recently available CPI-U to the date the
contributions are paid, subject to a cap of six (6%) percent per year, noncompounded.
P0806462
Attachment D – Special Use Permit Plan
Dated January 30, 2018 and revised on April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page D-1
Attachment D – Special Use Permit Plan
Dated January 30, 2018 and revised on April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page D-2
Attachment D – Special Use Permit Plan
Dated January 30, 2018 and revised on April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page D-3
Attachment E – Canopy Details
Dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page E-1
Attachment F – Signage
Dated April 19, 2018
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page F-1
Attachment G – Historical Commission Resolution
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page G-1
Attachment G – Historical Commission Resolution
#SUP2018-00026, Chick-fil-A at Sudley Manor Drive
Page G-2