The information contained within this information package remains the sole intellectual property of Grant Lamont T/AS Another Room. All uses of this information other than in connection with Another Room products is expressly PROHIBITED with out consent of Another Room. Copying of information for consent authority purposes or in connection of sales of Another Room products is permitted. All products interlectual property referenced in these documents remain the sole property of their individual owners / companies and Grant Lamont T/AS Another Room does not take responsibility for any error or in accuracy in technical details provided from said companies.
Lamont family Trust T/as Mob 0428 632247
Email: [email protected] Ph/fax 02 44 740393
WEB: www.anotherroom.com.au ABN. 45103119631
BUILDING SPECIFICATIONS SKID
BUILDING SKID CONSISTS OF TWO HIGH QUALITY GALVANIZED CHANNELS WITH GALVANIZED BOX SECTION FLOORING JOISTS INSTALLED TO AUSTRALIAN BUILDING STANDARD SPACINGS, FULLY WELDED AND CORROSION PROTECTED BRACED FOR STRUCTURAL INTEGRITY, DESIGN FOR STRENGTH, LONG LIFE AND NUMEROUS RELOCATION'S.
FLOOR
FLOOR CONSISTS OF 19 MM THICK GREEN TONGUE PARTICLE FLOOR SHEETS TERMITE TREATED AS USED IN GENERAL HOUSE CONSTRUCTION ( NOT 12 MM PLY AS GENERALLY USED) SCREWED TO FLOOR JOISTS INSTALLED UP INSIDE OF BUILDING PANELS TO GUARANTEE WEATHER PROOFING.
WALLS & CEILING
BUILDING WALLS & CEILING ARE CONSTRUCTED FROM HIGH QUALITY COOL ROOM INSULATION ( EPS) PANELS (UTILIZING BLUE SCOPE 0.6 MM CRP PANEL SKINS) MAXIMIZING THE USE OF THEIR EXCELLENT THERMAL AND NOISE INSULATION PROPERTIES TO CREATE A CONTROLLED ENVIRONMENT. THE EPS PANELS ARE AN AUSTRALIAN MADE PRODUCT MANUFACTURED IN SYDNEY UTILIZING THE BEST TECHNOLOGIES, AUSTRALIAN EXPANDED CFC FREE POLYSTYRENE AND HIGH QUALITY AUSTRALIAN ANTICORROSIVE BLUE SCOPE STEEL COLOR BOND SHEETING DEVELOPED FOR ARDUOUS INDUSTRY CONDITIONS. EPS PANELS ARE FLAME RETARDENT, SELF EXTINGUISHING AND HAVE BEEN TESTED BY CSIRO TO BE LESS TOXIC THAN NORMAL CONSTRUCTION METHODS DURING COMBUSTION. THEY HAVE NO NUTRIENT VALUE AND DO NOT SUPPORT BACTERIAL GROWTH, ATTRACT ANTS, TERMITES OR RODENTS
COLORS
PANELS ARE AVAILABLE IN 3 STANDARD COLORS, 4 NON STANDARD COLORS
STANDARD SURFMIST (OFF WHITE), PALE EUCALYPT (MIST GREEN) & PAPERBARK
(MERINO)
NON STANDARD CLASSIC CREAM, SHALE GREY, DUNE & FASCADE, CITI METALLIC
ROOF
BUILDINGS ARE OVER ROOFED WITH BLUE SCOPE COLOR BOND CORRUGATED ROOFING , FITTED WITH GUTTERS AND DRAINPIPES IN YOUR CHOICE OF COLORS FROM THE AVAILABLE BLUE SCOPE COLOR MATRIX FOR COLOR BOND WITH A 5 DEGREE CONCAVE PITCH.
DOORS & WINDOWS
BUILDINGS FITTED WITH HIGH QUALITY SLIDING WINDOWS AND DOORS INCLUDING SCREENS AVAILABLE IN YOUR CHOICE OF COLOR AS PER COLOR BOND COLORS (OPTIONAL PANEL DOORS AVAILABLE).
FLOORING
AVAILABLE WITH CHOICE OF LINO, CARPET OR CARPET WITH LINO INSERT ALONG WITH OPTION OF INDUSTRIAL LINO.
KITCHENS AVAILABLE WITH CUSTOM MADE KITCHENS AS REQUIRED USING QUALITY FLAT PACK KITS AND CUSTOM MADE BENCH TOPS.
ELECTRIC'S
BUILDING IS ENTIRELY PRE WIRED REQUIRING ONLY SITE CONNECTION BY QUALIFIED ELECTRICIAN INCLUDING SAFETY SWITCHES, 4 DOUBLE POWER POINTS, LIGHTS ETC., PRE WIRED FOR AIR CONDITIONING UNITS AND THEY CAN BE FITTED DURING CONSTRUCTION.
FOOTINGS & WIND RATINGS
ENGINEERED WIND CATEGORY RATING OF CATEGORY 2 (180 KM/HR PLUS (MUST BE INSTALLED AS PER RECOMMENDED FOOTING SPECIFICATIONS)). FOOTING DRAWINGS AND LOCATIONS SUPPLIED
BUILDING BENEFITS MINIMAL INTERRUPTION TO HOME LIFE DURING INSTALLATION EASILY INSTALLED BY ANY COMPETENT PERSON WINDOWS AND DOOR LAYOUT MAY BE LOCATED TO SUIT ALL REQUIREMENTS DUE TO TYPE OF PANEL CONSTRUCTION EASILY REMOVABLE AND RE SALE ABLE SIMPLE ANCHORING DESIGN WEATHER PROOF & ENERGY EFFICIENT EXCELLENT THERMAL AND NOISE PROPERTIES COST EFFECTIVE (PARTICULARLY WITH RESALE VALUE) AESTHETICALLY PLEASING EASILY ADAPTED OR DECORATED TO SUIT ALL TASTES/NEEDS FULLY WIRED REQUIRING A SIMPLE ELECTRICAL CONNECTION EASE OF DELIVERY AND INSTALLATION AS DESIGNED TO TRANSPORT ON TILT TRAYS OR TRUCK AND CRANE AS NECESSARY EXTREMELY LITE CONSIDERING STRENGTH AND SIZE MANUFACTURED USING THE BEST QUALITY PRODUCTS FULL INFORMATION PACKAGE TO ASSIST WITH COUNCIL REQUIREMENTS
POLYSTYRENE CORE BUTT JOINTSThe butt joints between the ends of the polystyrene core material have been made by way of finger jointing pro-viding a mechanical bond across the end faces of the core material.SURFACE PROFILES• The PPI Slip-joint® forms the edges of both skins with a male and female joint to either edge. Panels can be fin-ished flat or with a low profile of 0.75mm depth to either surface: • 100mm profile or • Silkline profile.
PRODUCT DESCRIPTIONPoly Panel Industries’ panels are 1200mm width stressed skin panels manufactured on an insulated panel produc-tion line. • Panel cores are self-extinguishing grade expanded polystyrene Class SL, as supplied by Poly Panel Indus-tries and bonded under pressure to BlueScope Steel Colorbond® pre-painted Galvabond or Zincalume base steel facings (using a two-part polyurethane adhesive). Thickness ranges with the EPS core material from 50 to 300mm in multiples of 25mm to suit thermal or structural requirements (conditions apply). • Panels are available in continuous lengths up to 18 metres (subject to transport facilities), manufactured to order and cut to the specified length.• Steel facings can range in thickness from 0.40mm to 0.60mm for either surface skin.• Standard finish is an oven-cured 25% Gloss level Per-magard™ White in Microban® for antibacterial protec-tion. There are other colours in the Colorbond® range subject to availability.THERMAL PERFORMANCE
SL Grade EPS
Panel Thickness (mm)
R value(m2K/W)
U factor(W/m2K)
50 1.32 0.76
75 1.97 0.51
100 2.63 0.38
150 3.95 0.25
200 5.26 0.19
250 6.58 0.15
300 7.90 0.13
SECTION PROPERTIESSection properties and mass for unit (1000mm) width of panel, together with the recommended maximum design skin stresses have been determined for panels of vary-ing panel thickness and these are shown below.
0.40mm Steel Skin
Thickness (mm)
Section Modulus(mm2)
Maximum Design Skin Stress (MPa)
Weight (kg/m2)
50 21230 65 7.7
75 32020 60 8.1
100 42800 50 8.4
150 64370 42 9.0
0.60mm Steel Skin
Thickness(mm)
SectionModulus(mm2)
MaximumDesign SkinStress (MPa)
Weight(kg/m2)
50 31590 48 10.9
75 47770 48 11.2
100 63940 48 11.6
150 96300 48 12.2
200 128660 48 12.9
250 161020 48 13.6
300 193380 48 14.4
POLY PANELEPS Core Insulated Panel
SPECIFICATIONS AT A GLANCECorePanel cores are fi re-resistant XFlam™ based on syntactic technol-ogy. XFlam™ comprises a composite blend of specifi c phenolic resins and various fi lling materials, manufactured to Australian standards. Steel skins are bonded to the core under pressure using a two-part thermosetting polyurethane adhesive.SkinsSheet thickness can range from 0.40mm to 0.60mm for either surface skin. Panel skins are available with a choice of steel:• Colorbond® Permagard™ steel, incorporating Microban® antibacterial technology in its coating to provide durable, food-safe performance that will not wash off . This steel is available in Permagard™ White only.• Colorbond® standard grade steel comes in a wide range of designer colours.• There are other skin materials available on request, including Stainless Steel, Aluminium and Printech™ printed steel.ColourThe many colours available in Colorbond® range from traditional to modern. For Prestige Applications there is Colorbond® Metalic steel.Generally, the lighter colours are preferred for EPS panel used externally, because they refl ect solar radiation. The various surfaces and colour choice can infl uence the price per square metre - our sales staff will gladly assist you in your selection.Dimensions• Width: 1200mm as a modular standard.• Thickness: 50 to 250mm in multiples of 25mm.• Length: Cut to order, a minimum length 1000mm to a maximum of 22000mm.Profi lesAvailable with a fl at surface fi nish or low profi le of 0.75mm depth to either surface: 100mm Rib profi le, 50mm Mesa Rib and Silkline.The Austral Slip-joint® is incorporated into the edges of both surface skins for easy installation.
THERMAL PERFORMANCE (XFlam™ core )
Panel Thickness (mm)
R value(m2K/W)
Weight(kg/m2)
50 1.61 12.7
75 2.42 13.7
100 3.23 14.6
150 4.84 16.5
200 6.45 18.4
250 8.06 20.3
Austral Insulation panel on display:Some of the various applications
for Austral Insulation laminated insulated panel are illustrated above:Residential dwellings, Public buildings and Refrigerated storage facilities.
Orders for panelAll panels are manufactured to order. Wall panel can be supplied with rebate ends for support to the ceiling or mitre edge for corner joints. Ceiling panel is square cut. Orders should state your requirements, including preferred colours and profi le.
63489 PPI EPS Core Tech.indd 1 18/05/09 3:47 PM
EXPANDED POLYSTYRENE PANELSDENSITY - NOMINAL 13.5kg/m3
(0.40mm Steel Skin - 100mm Rib Profile)
MAXIMUM DESIGN UNIFORM LOADS FOR SINGLE SPAN PANELS
NOMINAL
PANEL
THICKNESS
50
75
100
150
SAFE UNIFORM LOADS kN/m2 (Self Load has been deducted)
Single Span - Length in metres
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 9.0
1.38 1.10 0.92 0.79 0.69 0.55 0.44 0.36 0.31 0.26 0.23 0.20 - -
1.92 1.54 1.28 1.10 0.96 0.76 0.61 0.51 0.43 0.36 0.31 0.27 0.24 -
2.14 1.71 1.43 1.22 1.07 0.85 0.68 0.57 0.48 0.41 0.35 0.30 0.27 0.21
2.70 2.16 1.80 1.54 1.35 1.07 0.87 0.71 0.60 0.51 0.44 0.38 0.34 0.27
EXPANDED POLYSTYRENE PANELSDENSITY - NOMINAL 13.5kg/m3
(0.60mm Steel Skin - 100mm Rib Profile)
MAXIMUM DESIGN UNIFORM LOADS FOR SINGLE SPAN PANELS
NOMINAL
PANEL
THICKNESS
50
75
100
150
200
250
300
SAFE UNIFORM LOADS kN/m2 (Self Load has been deducted)
Single Span - Length in metres
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 9.0
1.71 1.36 1.14 0.97 0.76 0.60 0.49 0.40 0.34 0.29 0.25 0.22 0.19 0.15
2.58 2.06 1.72 1.47 1.15 0.91 0.73 0.61 0.51 0.43 0.37 0.33 0.29 0.23
3.45 2.76 2.30 1.97 1.53 1.21 0.98 0.81 0.68 0.58 0.50 0.44 0.38 0.30
5.20 4.16 3.47 2.97 2.31 1.83 1.48 1.22 1.03 0.88 0.75 0.66 0.58 0.46
6.95 5.56 4.63 3.97 3.09 2.44 1.98 1.63 1.37 1.17 1.01 0.88 0.77 0.61
8.70 6.96 5.80 4.97 3.86 3.05 2.47 2.04 1.72 1.46 1.26 1.10 0.97 0.76
10.44 8.35 6.96 5.97 4.64 3.67 2.97 2.45 2.06 1.76 1.52 1.32 1.16 0.92
Notes 1) The tabulated safe loads are recommended unfactored maximum nett loads. (In the assessment of the design loads, the designer should take into account the self weight of the panel). 2) Compliance with these recommendations will ensure that deflections do not exceed span/90. Where more severe deflection restrictions are required, specific testing of deflection characteristics is recom mended for the various span/thickness combinations. 3) A minimum design load of 0.5kN/m2 is recommended for general applications. Circumstances may require different design loading. 4) Where panels are continuous across a support, it is recommended that stress cuts be made across the inside (or cold side) steel skin adjacent to the supports to prevent buckling of the outer (warm side) skin at the support. Fixings should be provided on both sides of the stress cut. 5) The finger joints at the butt joints of the polystyrene core material occur every 5 metres. These provide a mechanical bond between the polystyrene core sheets. Adhesive bonding is not required.
Produced May 2009
POLY PANELEPS Core Insulated Panel
63489 PPI EPS Core Tech.indd 2 18/05/09 3:47 PM
1 of 2
GENERAL DESCRIPTION
COLORBOND® Insulation Panel steel, designedby BlueScope Steel Limited, specifically for themanufacture of sandwich panels for coolrooms.The product offers excellent formability coupledwith good durability.
TYPICAL USESCoolroom panels.
AUSTRALIAN STANDARDSubstrate – AS 1397Paint Coating – AS/NZS 2728:1997 Type 3
PREFERRED SUBSTRATES ZINCFORM® G300 Z275 BFC steel
Please refer to current price list or BlueScope Steel Limited State Sales Office for availability of colours and dimensions.
Only light colours are available. Colour in the ‘L’ scale is greater than 50. The product is supplied with a nominal 25%(60º) gloss.
Protective film (CORSTRIP®) should be removed from the painted steel strip immediately on installation. Sunlight canincrease the adhesion of the protective film to the painted surface if left uncovered outside. Refer to brochure ‘The smartway to design, install and maintain COLORBOND® steel’.
LINE TESTED PROPERTIESProperty Measured By Test Method Results
Hardness Pencil AS/NZS 1580 405.1 HB or harderNCCA Tech. Bull. 4.2.5
Adhesion Reverse Impact AS/NZS 2728 (App. E) ≥10 joulesNCCA Tech. Bull. 4.2.6
T - bend AS/NZS 2728 (App. F) Maximum 6TNCCA Tech. Bull. 4.2.8
Specular gloss 60º meter AS/NZS 1580 602.2 15 - 35%ASTM D523
EXPECTED PRODUCT SERVICE PERFORMANCEProperty Measured After Test Method Results
Resistance to colour change QUV (2000 hours) ASTM G53 ∆ E Hunterlab:Light colour: ≤6 units
Natural well washed ASTM D2244 ∆ E Hunterlab:exposure (10 years) Light colour: ≤6 units
Resistance to chalking QUV (1000 hours) ASTM G53 Rating: ≤4AS/NZS 1580 481.1.11(Method B)
Natural well washed AS/NZS 1580 481.1.11 Chalk rating: ≤4exposure (10 years) (Method B)
Resistance to corrosion Salt spray (500 hours) ASTM B117 Blister density: ≤2AS 2331.3.1 Blister size: ≤S2NCCA Tech. Bull. 5.4.6 Undercut from a score: ≤2mmAS/NZ 2728 (App. H3) No loss of adhesion
Kesternich (SO2) DIN 50018 Edge creep: <4mm(50 cycles) Blisters: nil
Resistance to humidity Cleveland (1000 hours) NCCA Tech. Bull. 5.4.5 Blister density: ≤2Blister size: ≤S2No loss of adhesion
Resistance to acids Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Protective Film may be available on requestFinish Coat (Nominal 20µm)Universal Corrosion Inhibitive Primer (Nominal 5µm)Conversion Coating
Galvanized Steel Substrate
Conversion CoatingUniversal Corrosion Inhibitive Primer (Nominal 5µm)Backing Coat (Custom Formulated Foam Grey, Nominal 5µm)
COLORBOND® InsulationPanel steel
Designed for: Coolroom Panels
Revision 6, November 2003This literature supersedes all previous issues
2 of 2
EXPECTED PRODUCT SERVICE PERFORMANCE (Cont.)Property Measured After Test Method Results
Resistance to solvents Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Adhesion Natural well washed – No flaking or peelingexposure (10 years)
Resistance to fire Exposure AS/NZS 1530.3 Ignitability index:0 rating in scale of 0 -20Spread of flame index:0 rating in scale of 0 -10Heat evolved index:0 rating in scale of 0 -10Smoke evolved index:0 -1 rating in scale of 0 -10
Flexibility T - bend AS 2935 (App. E) Maximum 8T (no cracking)NCCA Tech. Bull. 4.2.8
Resistance to abrasion Taber Abraser – 1000g AS/NZS 1580 403.2 ≤20mg per 100 cyclesCS 10 wheels NCCA Tech. Bull. 4.2.5
Scratch AS/NZS 1580 Typically 2000g
NOTE
➀ Values quoted are for standard colours of COLORBOND® Insulation Panel steel under normal well washed conditions of exposure.
➁ Product may not be suitable if it is intended to use COLORBOND® Insulation Panel steel in an exterior application within1km of salt marine locations, severe industrial or abnormally corrosive environments, areas not washed by rain, or inapplications where it will be wholly or partly buried in the ground. Before purchase, you should check on suitabilitythrough contacting your nearest BlueScope Steel Limited Sales office for advice.
➂ COLORBOND® Insulation Panel steel has good resistance to accidental spillage of solvents such as methylated spirits,white spirit, mineral turpentine, toluene, trichloroethylene and dilute mineral acids and alkalis. However, all spillagesshould be immediately removed by water washing and drying.
➃ For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss ofductility compared with unpainted product. However, minimum strength levels designated by relevant standards will stillbe applicable.
➄ Improper storage or the use of non-approved roll-forming lubricants may adversely affect colour. Material which becomeswet while in stacks or bundles must be separated and dried (refer AS/NZS 2728 Appendix K).
➅ Customers should use product promptly (within 6 months) to avoid the possibility of storage related corrosion and aphenomena of galvanized coatings termed intergranular corrosion.
COLORBOND®, ZINCALUME® and CORSTRIP® are registered trade marks of BlueScope Steel Limited.
BlueScope is a trade mark of BlueScope Steel Limted.
Please ensure you have the current data sheet for this product as displayed at www.bluescopesteel.com.au
BlueScope Steel LimitedBlueScope Steel Limited ABN 16 000 011 058 Copyright © 2003 BlueScope Steel LimitedBlueScope Steel (AIS) Pty Ltd ABN 19 000 019 625
SYDNEY: (02) 9795 6700 MELBOURNE: (03) 9586 2222 BRISBANE: (07) 3845 9300 ADELAIDE: (08) 8243 7333 PERTH: (09) 9330 0666
Produced by Artimprint (02) 9984 8586
COLORBOND® InsulationPanel steel
Designed for: Coolroom Panels
ContinuedRevision 6, November 2003This literature supersedes all previous issues
1 of 2
PREFERRED SUBSTRATES ZINCALUME® G550S AZ150 steelZINCALUME® G300S AZ150 steel
Please refer to current price list or BlueScope Steel Limited State Sales Office for availability of colours and dimensions.
The finish coat can, if required, be applied to both sides to provide a ‘double sided’ product. The product is supplied witha nominal 25% (60º) gloss.
The protective film (CORSTRIP®) should be removed from the painted steel strip immediately on installation. Sunlight canincrease adhesion of the protective film to the painted surface if left uncovered outside. Refer to brochure ‘ The smartway to design, install and maintain COLORBOND® steel .’
LINE TESTED PROPERTIESProperty Measured By Test Method Results
Hardness Pencil AS/NZS 1580 405.1 HB or harderNCCA Tech. Bull. 4.2.5
Adhesion Reverse Impact AS/NZS 2728 (App. E) ≥10 joulesNCCA Tech. Bull. 4.2.6
T - bend AS/NZS 2728 (App. F) Maximum 5TNCCA Tech. Bull. 4.2.8
Specular gloss 60º meter AS/NZS 1580 602.2 15 - 35%ASTM D523
EXPECTED PRODUCT SERVICE PERFORMANCEProperty Measured After Test Method Results
Resistance to colour change QUV (2000 hours) ASTM G53 ∆ E Hunterlab:Intermediate colour:≤5 unit, eg Wheat
Natural well washed ASTM D2244 ∆ E Hunterlab:exposure (15 years) Light colour: ≤6 units
Int. colour: ≤9 unitsDark colour: ≤15 units
Resistance to chalking QUV (2000 hours) ASTM G53 Rating: ≤4AS/NZS 1580 481.1.11(Method B)
Natural well washed AS/NZS 1580 481.1.11 Chalk rating: ≤4exposure (10 years) (Method B)
Resistance to corrosion Salt spray (1000 hours) ASTM B117 Blister density: ≤2AS 2331.3.1 Blister size: ≤S2NCCA Tech. Bull. 5.4.6 Undercut from a score: ≤2mm
No loss of adhesion
Kesternich (SO2) DIN 50018 Edge creep: <4mm(50 cycles)
Resistance to humidity Cleveland (1000 hours) NCCA Tech. Bull. 5.4.5 Blister density: ≤2Blister size: ≤S2No loss of adhesion
Resistance to acids Exposure ASTM D1308 No discolouration(3.1.1) No blistering
GENERAL DESCRIPTION
COLORBOND® prepainted steel, specifically designed by BlueScope SteelLimited to provide a high durability,premier cladding and roofing materialfor general use.
GENERAL DESCRIPTION
Roofing and accessories, wall cladding, rain water goods.
AUSTRALIAN STANDARDSubstrate – AS 1397Paint Coating – AS/NZS 2728:1997 Type 3-4
Protective Film may be available on requestFinish Coat (Nominal 20µm)Universal Corrosion Inhibitive Primer (Nominal 5µm)Conversion Coating
Conversion CoatingUniversal Corrosion Inhibitive Primer (Nominal 5µm)Backing Coat (Shadow Grey, Nominal 5µm)
ZINCALUME® - Zinc/Aluminium Alloy Coated Steel Substrate
COLORBOND® steelDesigned for: Exterior Roofing
and Walling
Revision 7, November 2003This literature supersedes all previous issues
2 of 2
Property Measured After Test Method Results
Resistance to alkalis Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Resistance to solvents Exposure ASTM D1308 No discolouration(3.1.1) No blistering
Adhesion Natural well washed – No flaking or peelingexposure (15 years)
Resistance to heat Exposure ASTM D2244 Colour change 100ºC continuous ∆ E Hunterlab: ≤3 units
Resistance to fire Exposure AS/NZS 1530.3 Ignitability index:0 rating in scale of 0 - 20Spread of flame index:0 rating in scale of 0 - 10Heat evolved index:0 rating in scale of 0 - 10Smoke evolved index:0 - 1 rating in scale of 0 - 10
Flexibility T - bend AS 2935 (App. E) Maximum 7T (no cracking)NCCA Tech. Bull. 4.2.8
Resistance to abrasion Taber Abraser - 1000g AS/NZS 1580 403.2 ≤20mg per 100 cyclesCS 10 wheels NCCA Tech. Bull. 4.2.5
Scratch AS/NZS 1580 403.1 Typically 2000g
NOTE
➀ For selection of the most appropriate COLORBOND® steel product refer to ‘Steel Roofing Products – Selection Guide TechnicalBulletin TB - 1a’, and ‘Steel Walling Products – Selection Guide Technical Bulletin TB - 1b’.
➁ Values quoted are for standard colours of COLORBOND® steel under normal well washed conditions of exposure. Product may notbe suitable if it is intended to use COLORBOND® steel in an exterior application within 1km of salt marine locations, severe industrialor abnormally corrosive environments, or in applications where it will be wholly or partly buried in the ground. Before purchase,you should check on suitability through contacting your nearest BlueScope Steel Limited Sales office for advice.
➂ COLORBOND® steel has good resistance to accidental spillage of solvents such as methylated spirits, white spirit, mineralturpentine, toluene, trichloroethylene and dilute mineral acids and alkalis. However, all spillages should be immediately removed bywater washing and drying.
➃ For most products, the metallurgical ageing process which is inherent in the paint stoving cycle will result in some loss of ductilitycompared with unpainted product. However, minimum strength levels designated by relevant standards will still be applicable.
➄ Improper storage or the use of non-approved roll-forming lubricants may adversely affect colour. Material which becomes wet whilein stacks or bundles must be separated and dried (refer AS/NZS 2728 Appendix K).
➅ The Backing coat is not recommended for exposure to direct sunlight. Where the reverse side will be exposed to direct sunlight, the“double sided” product is recommended.
➆ Definitions• Finish coat - the coating applied to the exposed surface of the prepainted coil or sheet which is expected
to meet the Performance Requirements.• Backing coat - a thin (pigmented or clear) coating applied to the reverse or unexposed surface of the
prepainted coil or sheet for the purpose of protection against damage to the topcoat duringshipment and storage. It also gives additional durability to the reverse or unexposed surfaceduring the service life of the product. Performance Requirements are not generally applicable toBacking coats. Where specific Performance Requirements are deemed necessary for the reversesurface coating “double sided” product should be specified, in which case a topcoat of fullnominal thickness will be applied.
EXPECTED PRODUCT SERVICE PERFORMANCE (cont.)
COLORBOND®, ZINCALUME® and CORSTRIP® are registered trade marks of BlueScope Steel Limited.
BlueScope is a trade mark of BlueScope Steel Limted.
Please ensure you have the current data sheet for this product as displayed at www.bluescopesteel.com.au
BlueScope Steel LimitedBlueScope Steel Limited ABN 16 000 011 058 Copyright © 2003 BlueScope Steel LimitedBlueScope Steel (AIS) Pty Ltd ABN 19 000 019 625
SYDNEY: (02) 9795 6700 MELBOURNE: (03) 9586 2222 BRISBANE: (07) 3845 9300 ADELAIDE: (08) 8243 7333 PERTH: (09) 9330 0666
Produced by Artimprint (02) 9984 8586
COLORBOND® steelDesigned for: Exterior Roofing
and Walling
ContinuedRevision 7, November 2003This literature supersedes all previous issues
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
70 * 40 mm angle
frame 40 * 40 * 2.5 mm RHS
SPREADER 40 * 40 *2.5 RHS
DOOR OPENING
CUT AS REQUIRED
FRAME
WELDED TO FRAME
COLORBOND CORRUGATED
SEE TYPICAL SKID DWG FOR DETAILS OF SKID
PITCH APPROX 5 DEGREES
PORTABLE PANEL BUILDINGS
TYPICAL ASSEMBLY DWG
QUAD GUTTER FULL LENGTH EACH SIDE
DOWN PIPES AT END OPP DOOR
40 * 40 ANGLE OR R50 MM COVING
POP RIVETED TO RAIL
5/32 * 3/8 RIVETSUNDER FLOOR INSULATION AS REQUIRED
EPS WALL PANEL 75 MM r1.9
BATTERNS AS REQUIRED DEPENDANT ON BUILDING WIDTH
75 mm wall
panels secured 300 mm spacings inside & out 5/32 rivets
40 * 40 * 1.6 mm Angle
F3
MAX SPAN BETWEEN PIERS 2.7 MTRS
0.42 BMT @ 900 C/C MAX
site buildings up to 3 mtrs 50 mm eps wall and 75 mm eps roof
site building 3.6 mtr 50 mm eps wall and 100 mm eps roof
alpine buildings up to 3.6 mtrs wide 75 mm eps wall and 100 mm eps roof
alpine buildings up to 4.5 mtrs wide 75 mm eps wall and 150 mm eps roof
Max altitude = 930 mtrs snow load 1.5 kpa ult.
75
mm
ep
s m
ax h
eig
ht
3.0
mtr
50
mm
ep
s m
ax h
eig
ht
to c
eili
ng
2.5
mtr
s
all specs are minimum sizes
6060t5
0100
150 * 50 * 3 RHS GAL
22MM GREEN TOUNGUE FLOOR OFFICES / COMMERCIAL
75 * 75 * 4 GAL ANGLE
Structural design for category 2 to AS 1170.2, 50 m/sec ultimate.
N3 wind rating to AS 4055
19 MM GREEN TOUNGUE SCREWED FLOOR DOMESTIC
REV 1
sheltered location to AS 1170.3
COMMERCIAL / OFFICES FLOOR JOISTS 50 * 50 * 3MM RHS.
DOMESTIC FRAME FLOOR JOISTS 40 * 40 * 2.5 RHS @ 450 C/C
6060T5
ALL CONSTRUCTION TO BUILDING CODES OF AUSTRALIA.
12/5/11
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
FRAME
WELDED TO FRAME
PORTABLE PANEL BUILDINGS
TYPICAL ASSEMBLY DWG
40 * 40 ANGLE
POP RIVETED TO RAIL
5/32 * 3/8 RIVETS
UNDER FLOOR INSULATION AS REQUIRED
EPS WALL PANEL 75 MM r1.9
12/4/101
70 * 40 * 1.6 ALL ANGLE
5/32 RIVETS
SILICON SEAL
50 / 75 MM EPS
50 MM ALL COVE
RIVETS EVERY 600 MM
300 MM SPACINGS
WALL
5 DEGREE PITCH CORRI ROOF
TYPICAL FLOOR JOINT
TYPICAL WALL JOINT 1
5/32 RIVETS
50 / 75 MM EPS
RIVETS EVERY 600 MM
300 MM SPACINGS
5 DEGREE PITCH CORRI ROOF
300 MM EVE
40 * 40 * 1.6 ANGLE
75 * 30 * 2.5 CAPPING
5/32 RIVETS
200 MM SPACINGS
TYPICAL WALL JOINT 2 WITH EVES
50 MM ALUMINUM COVING
75 * 75 * 4 GAL ANGLE
POPRIVETS AT 300 MM SPACINGS AROUND BASE UNIT
H/D ALLUMINIMUM
BASE CHANNEL
AROUND ALL EXPOSED EDGES
19 MM GREEN TOUNGUE TERMI FLOOR SCREWED DOMESTIC LOADING
22MM GREEN TOUNGUE TERMI FLOOR SCREWED OFFICE / COMMERCIAL
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GLAS BUILT
CLIENT:MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
TYPICAL SPILT UNIT CONFIGURATION
EPS Skinned Foam Panel EPS Skinned Foam Panel
6 mm hex head bolts and nuts
CEILING TYPICAL LAYOUT CONNECTION
ROOF SHEET
RIDGE CAP
10.8 MTR
4 MTRS
6 & 7.2 MTR
8.4, 9.6 MTR
12 MTR
SPAN
C15015
PURLIN PFC BRIDGED
X
X
X
X
180
C20024
C30024
C35030 250
250 X
2 ROWS
BRIDGING
150
150
ROOF SUPPORT BEAM SPAN TABLE
*NOTE* CONFIGURATION TO ACHIEVE NECESSARY LOADINGS
16/6/11
0135
SPAN TABLE REQUIRES THE USE OF 2 BEAMS IN BACK 2 BACK
SPAN RATINGS AS SUPPLIED J.SKURR ENGINEERING. WIND LOAD CAT 2 TO AS1170, N3 TO AS1684
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GLAS BUILT
CLIENT:MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
besa block footingsbesa block footings besa block footings besa block footings
base skid details refer typical drawingsbase skid details refer typical drawings
75 mm hanger
75 mm crp ceiling & R2.5 insul blanket300 mm evesPurlin supporting beams as required
details to be provided BY John skurr engineering Canberra
colorbond roof. 5 degree corri or 3 degree 760 profile as required
40 * 40 * 2.5 RHS Galvanised
75 * 75 rhs supporting columns or similar
details as specified j. skurr engineering.
19mm H2 termi floor & R1.5 insul blanket
2400 mm
100 mm walls eps R2.4
BUILDING WIDTH PLUS EVES BUILDING WIDTH PLUS EVES
150 * 50 * 3 RHS GAL
DISTANCE AS REQUIRED
TYPICAL SPLIT UNIT ASSEMBLY
0136
16/6/11
FOOTING DETAILS AS PER STANDARD FOOTOING DWGS * 2 SET TO SUIT BUILD WIDTH
ROOF SUPPORT BEAM SPAN TABLE
SPAN PURLIN BRIDGED2 ROWS
BRIDGINGPFC
4 MTRS
6 & 7.2
8.4, 9.6
12 MTR
C15015
C20024
C30024
10.8 MTR C35030
250
250
180
150
150 X
X
X
X
X
*NOTE*SPAN TABLE REQUIRES THE USE OF 2 BEAMS IN BACK 2 BACK
CONFIGURATION TO ACHIEVE NECCESARY LOADINGS
commercial 22 mm floor, 50 mm rhs floor joist
SPAN RATINGS AS SUPPLIED, WIND CAT 2 AS1170, N3 AS1684
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
SIGNATURE DATE
SALES SIGNATURE
CLIENT NAME:
BUILDING SIZE
SCOLORBOND CORRI ROOF 5 DEGREE CONCAVE PITCH
DOWN PIPE
GUTTER
2900 mm
from bottom of skid
internal height 2420 mm
1000 h * 1500 wide window
1000
12 mtrs
450 mm to sub floor
900 mm
ac outdoor unit
Tony & Sheila
12 * 4.2 mtr unit
nth side elevation
27/3/10
exhaust fan
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
SIGNATURE DATE
SALES SIGNATURE
CLIENT NAME:
BUILDING SIZE
SCOLORBOND CORRI ROOF 5 DEGREE CONCAVE PITCH
DOWN PIPE
GUTTER
internal height 2420 mm
1000 h * 1500 wide window
1000
12 mtrs
450 mm to sub floor
900 mm
Tony & Sheila
12 * 4.2 mtr unit
27/3/10
2100h * 1800 wide slding glass door
sth side elevation
3200 mm aprox
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
SIGNATURE DATE
SALES SIGNATURE
CLIENT NAME:
BUILDING SIZE
GUTTER
450 mm to sub floor
900 mm
Tony & Sheila
12 * 4.2 mtr unit
27/3/10
2100h * 1800 wide slding glass door
colourbond corrigated concave roof 5 degree pitch
internal 75 mm insulation blanket R2.5
GUTTER
125 mm125 mm
d/pipes 100/50
ac out door unit
ac indoor head unit
west ( house ) side elevation
4.2 mtrs wide ( overall to gutter 4.5 mtrs)
WALLS 75 MM EPS R1.9 CEILING 100 MM EPS R2.63
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
PO BOX 647 MORUYA, NSW 2537
AS BUILT
CLIENT:
ANOTHER ROOM P/L
PH/FAX 02 44 740393 MOBILE 0428 632 247
SIGNATURE DATE
SALES SIGNATURE
CLIENT NAME:
BUILDING SIZE
GUTTER
900 mm
Tony & Sheila
12 * 4.2 mtr unit
27/3/10
colourbond corrigated concave roof 5 degree pitch
internal 75 mm insulation blanket R2.5
GUTTER
125 mm125 mm
d/pipes 100/50
ac out door unit
4.2 mtrs wide ( overall to gutter 4.5 mtrs)
800 mm pa door
600 * 600 frosted window
2040 high
300 mm
east side elevation.
WALL 75 MM EPS R1.9 CEILING 100 MM EPS R 2.63
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GLAS BUILT
CLIENT:
40 * 40 MM SPREADER 3 OFF
40 MM SPREADER
40 MM CENTRE UPRIGHT FLOOR SUPPORT
40 MM SPREADER40 MM SPREADER
MATERIALS
SKID RAILS
SPREADER RAILS BOTTOM SKID
SKID DETAIL ENDS
MAY VARY NUMBER OF SPREADERS DEPENDENT BUILD SIZE
ALL CONTACT POINTS
ANCHOR POINTANCHOR POINT
ANCHOR POINT ANCHOR POINT
40 * 40 * 2.5 MM GAL RHS
PORTABLE PANEL BUILDINGS
TYPICAL SKID DWG.ANOTHER ROOM
P.O BOX 647 MORUYA NSW 2537
PH/FAX 02 44 740393 MOBILE 0428 632247
AROUND BUILDING PERIMETER WTITH 40 MM RETAING ALLUMINUM ANGLE
40 * 40 * 1.6
FLOOR JOIST SPACING 450 MM CENTRES
50
50
32 MM DIA HOLE
75 * 75 MM * 3 RHS LIFTING POINTS
1800 M
M
75 * 75 * 4 GAL ANGLE WELDED TO 40 MM FLOOR JOISTS AROUND FULL EDGE BUILDING
75 * 75 * 4 GAL ANGLE WELDED TO 40 MM FLOOR JOISTS AROUND FULL EDGE BUILDING
40 * 40 * 2.5 RHS
EVERY 2ND FLOOR JOISTWHEN BUILD EXCEEDS 3 MTRS
50 * 50 * 3 GAL ANGLE WELDED TO 40 MM FLOOR JOISTS FOR SITE SHEDS
150 * 50 * 3 RHS GAL RAILS CANTILEVER BRACKETS
FLOOR JOISTS
40 * 40 * 2.5 GAL SHS DOMESTIC
150 * 50 * 3 GAL RHS RAILS
FLOOR JOISTS LENGTH 2.4 MTR BUILD
(2240mm, o/hang 220 mm from rails)
FLOOR JOISTS LENGTH 3 MTR BUILD(2840 mm, o/hang 520 mm from rails)
FLOOR JOISTS LENGTH 3.6 MTR BUILD(3440 mm, o/hang 820 mm, cantaliver brackets)
(every second joist as required)
WIDE
FLOORING 19 MM GREEN TOUNGUE TERMI FLOOR PARTICLE BOARD DOMESTIC LOADING
22MM GREEN TOUNGUE TERMI FLOOR PARTICLE BOARD OFFICE LOADING
4/5/11
0102
REV 2
50 * 50 * 3 Gal OFFICES / COMMERCIAL
ALL CONSTRUCTION TO BUILDING CODES OF AUSTRALIA
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GLAS BUILT
CLIENT:
MATERIALS
SKID RAILS
SPREADER RAILS BOTTOM SKID
SKID DETAIL ENDS
MAY VARY NUMBER OF SPREADERS DEPENDENT BUILD SIZE
ALL CONTACT POINTS
40 * 40 * 2.5 MM GAL RHS
PORTABLE PANEL BUILDINGS
TYPICAL SKID DWG.ANOTHER ROOM
P.O BOX 647 MORUYA NSW 2537
PH/FAX 02 44 740393 MOBILE 0428 632247
AROUND BUILDING PERIMETER WTITH 40 MM RETAING ALLUMINUM ANGLE
40 * 40 * 1.6
FLOOR JOIST SPACING 450 MM CENTRES
50
50
32 MM DIA HOLE
75 * 75 MM * 3 RHS LIFTING POINTS
SPREADER1800
75 * 75 * 3 BRACES AND LIFT POINTS
200
200
75 * 75 * 4 GAL ANGLE WELDED TO 40 MM FLOOR JOISTS
75 * 75 * 4 GAL ANGLE WELDED TO 40 MM FLOOR JOISTS
(350)
(350)
4.2 / 4.5 SKID
HANGER 75 * 75 * 4 GAL ANGLE
FLOOR JOISTS LENGTH 4.2 MTR BUILD
FLOOR JOISTS LENGTH 4.5 MTR BUILD
( 4000 MM LONG, 200 MM OVER HANG)
(4300 MM LONG WITH 350 MM O/HANG)
75 * 75 * 3 BRACES AND LIFT POINTS
75 * 75 * 3 RHS GAL SPREADERS
MAXIUMUM DISTANCE APART 3 MTRS C/C
75 * 75 * 3 RHS GAL SPREADERS
75 * 75 * 3 RHS GAL SPREADERS
LIFT POINTS SEAM WELDED AND BRACED
TO FLOOR JOISTS, WELD TO ANGLE
75 * 75 * 3 LIFT POINTS
00039
150 * 50 * 3 RHS GAL
DOMESTIC
50 * 50 * 3 RHS GAL OFFICE /COMMERCIAL
150 * 50 * 3 SHS GAL RAILS
1800
FLOOR JOIST
FLOORING 19 MM GREEN TOUNGUE TERMI FLOOR PARTICLE BOARD DOMESTIC LOADING
22 MM GREEN TOUNGUE TERMI FLOOR PARTICLE BOARD OFFICE LOADING
4/5/11
REV 1
ALL CONSTRUCTION TO BUILDING CODES OF AUSTTRALIA
SCALE DRAWN BY SHEET OF
DATE CHCKD JOB No
DWG No
TITLE
PROJECT
N.T.S G.L
GL
MANUFACTURER
AS BUILT
CLIENT:
600
PP
PP
PP
PP
LS
J BOX POWER ENTRY
20 MM CONDUIT
HALF SADDLE MOUNT TO SKID
LIGHT CIRCUIT RUN UP CORNER
ACCROSS WALL CRACK
DOWN TO SWITCHES, OUT TO BULK HEAD UP TO LIGHTS
BULK HEAD LIGHT
270 MM IN FROM DOOR CUT
340 MM TO CENTRE FROM ROOF
HOLE DRILL 280 FROM ROOF, 330 FROM DOOR CUT
130 H TO BOTTOM
180 IN FROM EDGE TO SIDE
SWITCHBOARD 60 MM IN FROM CORNER
1650 HIGH TO CENTRE
ALL CABLES UP CORNER
***NOTES***
25 MM HOLES IN GAL HANGER WITH BUSHES AT ALL PPOINTS AND IN MAIN CORNER
SWITCHBOARD AND ALL PPOINTS 50 MM HOLE & BUSH 225 TO CENTRE ( 5 BUSHES REQUIRED)
AIRCON CIRCUIT RUN TO POWER POINT POS 2
1
2AC1 3
4
EARTH 6 MM SKID TO J BOX AND BOARD
CONDUIT THROUGH ROOF AT LIGHT FITTINGS ( OR BUSHS)
MATERIALS
3 MTRS 6MM 2 C & E
35 NTRS 2.5 MM 2C & E
12 MTRS 1.5 MM 2C & E
2 OFF BATTER HOLDERS
1 OFF 3 GANG PLATE & 2 MECHS
1 OFF DIMMER
5 OFF SLIM LINE MOUNT BLOCKS 14MM
5 OFF 50 MM BUSHES
12 OFF 25 MM BUSHES
1 OFF 100 * 100 J BOX
8 MTRS CONDUIT20 MM
25 CONDUIT HALF SADDLES
12 POLE BOARD
1 32 AMP RCD/MCB
1 16 AMP CB
1 10 AMP CB
4 DOUBLE GPO,S
1 BULK HEAD LIGHT FIT.
3 MTRS 6 MM EARTH
FLOORING 20 MM GREEN TONGUE
START FROM DOOR END & SIDE
P.O BOX 647 MORUYA NSW 2537
PH/FAX 02 44 740393 MOBILE 0428 632247
ANOTHER ROOM
LIGHT SWITCH 1300 MM ABOVE FLLOR POSISTIONED NEST TO OPENING SIDE DOOR FRAME
PORTABLE PANEL BUILDINGS