corrosion of steel reinforcement in concrete. overview introduction mechanisms of steel corrosion...

56
Corrosion of Steel Corrosion of Steel Reinforcement in Concrete Reinforcement in Concrete

Upload: kaelyn-regester

Post on 29-Mar-2015

276 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Corrosion of Steel Reinforcement in Corrosion of Steel Reinforcement in Concrete Concrete

Page 2: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

OverviewOverview

• Introduction

• Mechanisms of Steel Corrosion

• Control of Corrosion

Page 3: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

IntroductionIntroduction

• One of the principal causes of concrete deterioration in KSA.

• The damage is especially large in the structures exposed to marine environment , contaminated ground water, or deicing chemicals.

• 1991 report FHWA in U. S. reported that 134,00 (23% of the total) bridges required immediate repair and 226,000 (39% of the total) were also deficient. The total repair cost was estimated at $ 90 billion dollars.

Page 4: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

CRACKING OF CONCRETECRACKING OF CONCRETE

• Heat of hydration

• Alkali-aggregate reactivity

• Carbonation

• Sulfate attack

• Acid and chemicals

• Reinforcement corrosion

Page 5: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

REINFORCEMENT CORROSIONREINFORCEMENT CORROSION

• Passivity– High pH leading to formation of passive layer– Chemical binding of chlorides– Dense and impermeable structure of concrete

• Depassivation– Chloride ingress– Carbonation

Page 6: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

MECHANISMS OF MECHANISMS OF REINFORCEMENT CORROSIONREINFORCEMENT CORROSION

Page 7: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 8: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 9: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

FACTORS AFFECTING FACTORS AFFECTING REINFORCEMENT CORROSIONREINFORCEMENT CORROSION

• Depassivation of steel

• Potential variation

• Availability of the reaction products, namely oxygen and moisture

• Electrical resistivity of concrete– Moisture– Chloride and sulfate contamination

Page 10: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

FACTORS INFLUENCING FACTORS INFLUENCING REINFORCEMENT REINFORCEMENT

CORROSIONCORROSION• Carbonation• Chlorides• Moisture• Oxygen diffusion• Concrete mix variables• Construction variables• Temperature• Humidity

Page 11: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Chloride-induced Chloride-induced Reinforcement CorrosionReinforcement Corrosion

• Due to the external chlorides in substructures

• Due to chloride contamination from the mix constituents in the superstructures

Page 12: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Chloride LimitsChloride Limits

• ACI 318 (0.1 – 0.15%; water soluble)

• ACI 224 (0.2%; acid soluble)

• BS 8110 (0.4%; total)

Page 13: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Damage to ConcreteDamage to Concrete

Page 14: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Mechanisms of Steel CorrosionMechanisms of Steel Corrosion

• Corrosion of steel in concrete is an electrochemical process.

• The electrochemical potentials to form the corrosion cells may be generated in two ways:1. Two dissimilar metals are embedded in concrete,

such as steel rebars and aluminum conduit pipes, or when significant variations exist in surface characteristics of the steel.

2. In the vicinity of reinforcing steel concentration cells may be formed due to differences in the concentration of dissolved ions, such as alkalies and chlorides.

Page 15: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Mechanisms of Steel CorrosionMechanisms of Steel Corrosion

• As a result, one of the two metals (or some parts of the metal when only one type of metal is present) becomes anodic and the other cathodic.

• The fundamental chemical changes occurring at the anodic and cathodic areas are as follows:

Page 16: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Electrochemical Process of Steel Electrochemical Process of Steel CorrosionCorrosion

Page 17: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Anodic and Cathodic ReactionsAnodic and Cathodic Reactions

Anode: Fe 2e- + Fe2+

(metallic iron)

FeO (H2O)x

rust

Cathode: (½) O2 + H2O + 2e- 2(OH)-

air water

Page 18: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Oxidation State vs. Increase of Oxidation State vs. Increase of VolumeVolume

Page 19: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Corrosion ProcessCorrosion Process

Page 20: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Corrosion CellsCorrosion Cells

• Anodic reaction (involving ionization of metallic iron) will not progress far unless the electron flow to the cathode is maintained by the consumption of electrons.

• For the cathode process, therefore the presence of both air and water at the surface of the cathode is absolutely necessary.

Page 21: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Steel PassivitySteel Passivity

• Ordinary iron and steel products are normally covered by a thin iron oxide film that becomes impermeable and strongly adherent to the steel surface in an alkaline environment, thus making the steel passive to corrosion.

• This means that metallic iron is not available for the anodic reaction until the passivity of steel has been destroyed.

Page 22: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Destroying Passive LayerDestroying Passive LayerIn absence of chloride ions in the solutionIn absence of chloride ions in the solution

• Protective film on steel is stable as long as the pH of the solution stays above 11.5.

• When concrete has high permeability and when alkalies and most of the calcium hydroxide have either been carbonated or leached away), the pH of concrete in the vicinity of steel may have been reduced to less than 11.5.

• This would destroy the passivity of steel.

Page 23: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Destroying Passive LayerDestroying Passive LayerIn presence of chloride ionsIn presence of chloride ions

• Depending on the Cl- /OH- ratio, the protective film is destroyed even at pH values considerably above 11.5.

• When Cl- /OH- molar ratio is higher than 0.6, steel is no longer protected, probably because the iron-oxide film becomes either permeable or unstable under these conditions.

Page 24: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Destroying Passive LayerDestroying Passive LayerIn presence of chloride ionsIn presence of chloride ions

• The threshold chloride content to initiate corrosion is reported to be in the range 0.6 to 0.9 kg Cl- per cubic meter of concrete.

• When large amounts of chloride are present, concrete tends to hold more moisture, which also increases the risk of steel corrosion by lowering the electrical resistivity of concrete.

Page 25: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

After the Destroy of PassivityAfter the Destroy of Passivity

Rate of corrosion will be controlled by:

• The electrical resistivity. [significant corrosion is not observed as long as the electrical resistivity of concrete is above 50 to 3 70 10 Ω.cm].

• The availability of oxygen.

Page 26: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 27: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 28: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 29: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 30: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 31: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 32: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 33: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 34: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Sources of Chloride in ConcreteSources of Chloride in Concrete

• admixtures,

• salt-contaminated aggregate,

• Penetration of seawater, groundwater, or

deicing salt solutions.

Page 35: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Corrosion of the Steel Reinforced Corrosion of the Steel Reinforced Concrete StructuresConcrete Structures

MARINE STRUCTURES BURIED UTILITIES

FOUNDATIONS BRIDGES & CULVERTS

Page 36: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Corrosion of the Reinforcing Steel in a Corrosion of the Reinforcing Steel in a Spandrel BeamsSpandrel Beams (17 years of service) (17 years of service)

Page 37: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

CARBONATIONCARBONATION

• Ca(OH)2 + CO2 CaCO3 + H2O

• Reduction in pH (up to 8.5)

Page 38: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Carbonation in uncontaminated cement Carbonation in uncontaminated cement mortarmortar

Page 39: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Carbonation in OPC mortar specimens Carbonation in OPC mortar specimens

contaminated with chloride plus sulfatecontaminated with chloride plus sulfate

Page 40: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Carbonation in fly ash cement mortar Carbonation in fly ash cement mortar contaminated with chloride plus sulfatecontaminated with chloride plus sulfate

Page 41: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 42: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 43: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 44: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 45: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 46: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 47: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 48: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion
Page 49: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• Permeability of concrete is the key to control the various processes involved in the phenomena.– Concrete mixture parameters to ensure low

permeability, e.g., low water-cement ratio, adequate cement content, control of aggregate size and grading, and use of mineral admixtures.

Page 50: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• Maximum permissible chloride content of concrete mixtures is also specified by ACI Building Code 318.

• Maximum water-soluble Cl- ion concentration in hardened concrete, at an age of 28 days, from all ingredients (including aggregates, cementitious materials, and admixtures) should not exceed – 0.06 % by weight of cement for prestressed concrete,– 0.15 % by weight of cement for reinforced concrete exposed to

chloride in service,,– and 0.30 % by mass of cement for other reinforced concretes,

respectively.

Page 51: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

– ACI Building Code 318 specifies minimum concrete cover of 50 mm for walls and slabs, and 63 mm for other members is recommended. Current practice for coastal structures in the North Sea requires a minimum 50 mm of cover on conventional reinforcement, and 70 mm on prestressing steel.

– RCJY and other agencies requires 75 mm minimum concrete cover.

Page 52: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• ACI 224R specifies 0.15 mm as the maximum permissible crack width at the tensile face of reinforced concrete structures subject to wetting-drying or seawater spray.

• The CEB Model Code recommends limiting the crack widths to 0.1mm at the steel surface for concrete members exposed to frequent flexural loads, and 0.2 mm to others.

• By increasing the permeability of concrete and exposing it to numerous physical-chemical processes of deterioration, the presence of a network of interconnected cracks and microcracks would have a deleterious effect.

Page 53: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• Waterproof membranes: are used when they are protected from physical damage by asphaltic concrete wearing surfaces; therefore, their surface life is limited to the life of the asphaltic concrete, which is about 15 years.

• Overlay of watertight concrete: 37.5 to 63 mm thick, provides a more durable protection to the penetration of aggressive fluids into reinforced or prestressed concrete members.

Page 54: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• Protective coatings for reinforcing steel are of two types: – anodic coatings (e.g., zinc-coated steel) very

limited use due to concern regarding the long-term durability.

– and barrier coatings (e.g., epoxy-coated steel), long-time performance of epoxy-coated rebars is still under investigation in many countries.

Page 55: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Epoxy-coated SteelEpoxy-coated Steel

Page 56: Corrosion of Steel Reinforcement in Concrete. Overview Introduction Mechanisms of Steel Corrosion Control of Corrosion

Control of CorrosionControl of Corrosion

• Cathodic protection techniques involve suppression of current flow in the corrosion cell, either by:– Supplying externally a current flow in the

opposite direction – or by using sacrificial anodes.

• Due to its complex and high cost the system is finding limited applications.