corrosion lecture
TRANSCRIPT
SSCC : SULPHIDE STRESS CORROSION
CRACKING
IGC : INTERGRANULAR CORROSION
TWO IMPORTANT CORROSIONS TYPES
ENCOUNTERED BY US ARE COVERED:
BROADLY CLASSIFIED AS :
LOW TEMPERATURE CORROSION
---- CORROSION AT ROOM
TEMPERATURE AND BELOW
HIGH TEMPERATURE CORROSION
---- ELEVATED TEMPERATURE
CORROSION INCLUDING
THAT BY MOLTEN METALS
MEDIA
ONE OF THE MOST IMPORTANT
FACTORS.
PROCESS FLUIDS
CONTAMINANTS
SOLVENTS
CATALYSTS ETC.
HIC --
HYDROGEN INDUCED CRACKING
SSCC ---
A CRACKING PROCESS THAT
REQUIRES SIMULTANEOUS ACTION
OF A CORRODENT AND SUSTAINED
TENSILE STRESS.
WATER :
FUNCTIONS AS ELECTROLYTE
HYDROLYSES INORGANIC SALTS
COMBINATION OF AIR & WATER
IS DANGEROUS ---
AIR SUPPLIES O2
WATER ACTS AS ELECTROLYTE
SOURCES :
ALMOST EVERY PART OF PROCESS
MEDIA :
EXCLUDED :
FAILURES DUE TO REDUCED SECTION AS A
RESULT OF CORROSION
FAILURES DUE TO INTER - CRYSTALLINE OR
TRANS - CRYSTALLINE CORROSION
H2S SOUR WATER
COMMON SOURCES :
CRUDE OIL
DECOMPOSITION OF ORGANIC
COMPOUNDS OF SULPHUR
PROCESS WATER CARRYING H2S
WITH NH3 HCN ETC.
H2S REACTS WITH STEEL TO GIVE
A BLACK SULPHIDE FILM
C.S. HAS GOOD RESISTANCE TO
AQUEOUS SULPHIDE CORROSION
SOUR WATER
COMMON SOURCES
PROCESS WATER CARRYING H2S
WITH NH3 HCN ETC
AQUEOUS H2S
C.S. AND LAS ARE USED
AQUEOUS H2S + NH3 ETC
CONDITION MORE SEVERE
C.S. & LAS NOT USED
DEPENDING ON SEVERITY
S.S OR TITANIUM USED
HIC NACE STANDARD TM - 02 84
SSCC NACE STANDARD TM - 01 77
HIC TESTING :
SPECIMEN SIZE :
20 X 20 X 100 mm
SOLUTION :
A -- SODIUM CHLORIDE +
ACETIC ACID ( pH 2.7 )
SATURATED WITH H2S
B -- SYNTHETIC SEA WATER
( AS PER ASTM D 1141 )
pH 8.1 - 83
SATURATED WITH H2S
TEST DURATION :
96 HOURS ( 4 DAYS )
FINAL pH
SOLUTION A -- 4.0
SOLUTION B -- 4.8 - 5.4
TEST RESULT :
THREE SECTIONS OBSERVED
BLISTERS SHALL BE NIL
CSR , CLR AND CTR SHALL
BE WITHIN SPECIFIED
LIMITS
CSR =100 [ (a x b) / ( W x T) ]
CLR =100 [ a / ( W x T) ]
CTR =100 [ b / ( W x T) ]
a = CRACK LENGTH
b = CRACK AREA THICKNESS
W = SECTION WIDTH
T = TEST SPECIMEN THICKNESS
SSCC TESTING :
SPECIMEN SIZE :
ROUND BAR TENSILE SPECIMEN
GAUGE DIA. 6.35 mm
GAUGE LENGTH 25.4 mm
( OVERALL LENGTH 200 mm)
SOLUTION :
A -- SODIUM CHLORIDE +
ACETIC ACID ( pH 2.6 - 2.8 )
SATURATED WITH H2S
B -- SODIUM CHLORIDE +
SODIUM ACETATE +
ACETIC ACID ( pH 3.4 - 3.6 )
SATURATED WITH H2S
TEST DURATION :
720 HOURS ( 30 DAYS )
FINAL pH
SOLUTION A -- 4.0
SOLUTION B -- 4.0
TEST LOAD :
GENERALLY LOADED TO
72% OF STANDARD METAL
YIELD STRENGTH.
THIS MAY BE CHANGED BY
CUSTOMER
TEST IS DEEMED PASSED IF
SPECIMEN DOES NOT BREAK
EXAMINATION AT 10 X DOES
NOT REVEAL CRACKS
SUSCEPTIBLE MATERIALS :
STAINLESS STEELS
PROCESS :
CORROSION RESISTANCE OF
STAINLESS STEELS IS DERIVED
FROM
Cr + O2 --------> Cr2O3
FROM
METAL
FROM
ATMOSPHERE
Cr2O3 FORMS A TENACIOUS FILM
ON THE SURFACE.
MINIMUM 12 % Cr IS NEEDED
TO MAKE STEEL STAINLESS
WHEN S.S. PASSES THROUGH THE
TEMPERATURE RANGE OF 425O C
TO 850O C WE HAVE :
C + Cr -----> Cr23C6
THE REACTION OCCURS AT
GRAIN BOUNDARIES
THUS THERE IS A BAND AT THE
GRAIN BOUNDARIES WHERE
Cr IS LESS THAN 12%
THIS AREA IS NO MORE
STAINLESS
THE PROCESS FLUIDS AND
CONTAMINANTS CAN ATTACK
IN THIS AREA.
THERE ARE A LOT OF PROCESSES
OF MANUFACTURING THAT TAKE
SS IN THIS RANGE
EG. WELDING ; CUTTING ; HOT/WARM
FORMING
SERVICE TEMPERATURE CAN ALSO
BE IN THIS RANGE
THUS THERE IS A NEED TO TEST
THE SUSCEPTABILITY TO IGC
THIS NEED IS GOVERNED BY
SERVICE CONDITIONS
APPLICABLE STD. ASTM A262
THERE ARE 5 PRACTICES
PRACTICE SOLUTION APPLICATION
A OXALIC ACID RAPID
ETCH TEST IDENTIFICATION
OF MATERIALS
WHICH WILL FAIL
B FERRIC SULPHATE DETECTS IGC BUT
+ SULPHURIC ACID NOT SIGMA PHASE
SUSCEPTABILITY
C 65 % NITRIC ACID DETECTS IGC BUT
AND SIGMA PHASE
SUSCEPTABILITY
E Cu +CuSO4 + DETECTS IGC BUT
16 % H2SO4 NOT SIGMA PHASE
SUSCEPTABILITY
F Cu +CuSO4 + DETECTS IGC BUT
50 % H2SO4 NOT SIGMA PHASE
SUSCEPTABILITY
PRACTICE TEST CONDITIONS
A ETCHING AND EXAMIN AT
250 x AND 500 x
B BOILING SOLUTION
120 HOURS
C BOILING SOLUTION
240 HOURS
E BOILING SOLUTION
24 HOURS
F BOILING SOLUTION
120 HOUR
NORMALLY PRACTICE B ; C AND E
ARE USED
IN PRACTICE B AND C WEIGHT
LOSS IS MEASURED.
THE CORROSION RATE IS GIVEN
BY THE WEIGHT LOSS
THIS IS NOT THE CORROSION
RATE IN ACTUAL SERVICE.
THE RESULT IS A RELATIVE
MEASURE
IN PRACTICE E SPECIMEN IS
BENT THROUGH 180O OVER A
FORMER OF 1T RADIUS.
THE BENT SURFACE IS EXAMINED
AT 100 x AND 250 x
TEST IS PASSED IF THERE ARE NO
CRACKS. CRACKS FROM EDGE ,
WRINKLES AND ORANGE PEEL
EFFECT ARE DISREGARDED.
PRACTICE B EVALUATION
Millimeter Per Month = 7290 x W
A x d x t
W = Weight Loss in gms.
A = Total Area of the Sample in cm2
t = Time of Exposure in hours
d = Density of sample in gms / cc
Millimeter Per Month x 0.04 = Inches Per Month
Millimeter Per Month x 0.47 = Inches Per Year
Millimeter Per Month x 12 = Millimeter Per Year
Millimeter Per Month x 472 = mpy
Millimeter Per Month x Density / 3 =
Milligram Per Square Decimeter Per Day
PRACTICE C EVALUATION
3440880 (W)
( A ) ( d ) ( t )MPY =
A= Total Specimen area (cm2 )W= Weight loss ( gms)
d= Density of sample ( gms / cm3 )t = Time of exposure ( hrs)
PRACTICE E
EVALUATION
FAILED MARGINAL
( DOUBTFUL )
PASSED
STEP DUAL
DITCH
As Received
After exposure
After bending
PARENT METAL
100 x
100 x
100 x
HAZ
Before exposure
After exposure
WELD
Before exposure
After exposure
PASSED
FAILED